Carbohydrate Polymers Sep 2024In this work, we propose the formation of stretchable hydrogels at neutral pH from the physical crosslinking of chitosan (CS) and hyaluronic acid (HA) by polyelectrolyte...
In this work, we propose the formation of stretchable hydrogels at neutral pH from the physical crosslinking of chitosan (CS) and hyaluronic acid (HA) by polyelectrolyte complexation. A mixture of CS (M ≈ 600 kg/mol, degree of acetylation ≈ 50 %) solution and HA (M ≈ 77 kg/mol) solution was prepared with an excess of salts screening the electrostatic interactions CS/HA. In a controlled manner, the polyelectrolyte complexation was induced through the progressive dialysis of the salted polymer mixture against a sodium acetate solution (AcONa, 0.01 M) for 7 days. Depending on [HA], various materials were obtained: viscous solutions at [HA] = 0.75 % (w/v); hydrogels at [HA] = 1.50-2.24 % (w/v) with Young modulus of 14 kPa and stretchable to 200 %. The small angle X-ray scattering characterization of the hydrogels revealed a multiscale organization related to the conformation of the polymers induced by the physical interactions. The dialysis process with AcONa was optimized by adding a dialysis step against a zinc acetate solution containing Zn. The combination of polyelectrolyte complexation between CS/HA and metal complexation between Zn and the polymers led to an enhancement of the hydrogel stretchability up to 400 %.
PubMed: 38823929
DOI: 10.1016/j.carbpol.2024.122265 -
Artificial Organs Jun 2024Oxidative stress (OxSt) and inflammation are common in CKD and are known CV and mortality risk factors. In peritoneal dialysis (PD) OxSt and Inflammation even increase...
BACKGROUND
Oxidative stress (OxSt) and inflammation are common in CKD and are known CV and mortality risk factors. In peritoneal dialysis (PD) OxSt and Inflammation even increase due to the use of glucose-based solutions.
PATIENTS AND METHODS
This study analyzed in 15 PD patients the effect of 3 and 6 months of treatment with icodextrin-based glucose-free solutions on OxSt and inflammation, evaluating p22 protein expression (Western blot), NADPH oxidase subunit, essential for OxSt activation, MYPT-1 phosphorylation state, marker of RhoA/Rho kinase pathway (ROCK) activity, involved in the induction of OxSt (Western blot) and Malondialdehyde (MDA) production (fluorimetric assay). Interleukin (IL)-6 blood level (chemiluminescence assay) has been measured and used as a marker of inflammation.
RESULTS
p22 protein expression, MYPT 1 phosphorylation, and MDA were reduced after 3 months from the start of icodextrin (1.28 ± 0.18 d.u. vs. 1.50 ± 0.19, p = 0.049; 0.89 ± 0.03 vs. 0.98 ± 0.03, p = 0.004; 4.20 ± 0.18 nmol/mL vs. 4.84 ± 0.32 nmol/mL, p = 0.045, respectively). In a subgroup of 9 patients who continued the treatment up to 6 months, MYPT-1 phosphorylation was further reduced at 6 months compared to baseline (0.84 ± 0.06 vs. 0.99 ± 0.04, p = 0.043), while p22 protein expression was reduced only at 6 months versus baseline (1.03 ± 0.05 vs. 1.68 ± 0.22, p = 0.021). In this subgroup, MDA was reduced at 6 months versus baseline (4.03 ± 0.24 nmol/mL vs. 4.68 ± 0,32, p = 0.024) and also versus 3 months (4.03 ± 0.24 vs. 4.35 ± 0.21, p = 0.008). IL-6 level although reduced both at 3 and 6 months, did not reach statistical significance.
CONCLUSIONS
The reduction of OxSt with icodextrin-based PD solutions, although obtained in a small patients cohort and in a limited time duration study, strongly supports the rationale of using osmo-metabolic agents-based fluids replacing glucose-based fluids. Ongoing studies with these agents will provide information regarding preservation of peritoneal membrane integrity, residual renal function, and reduction of CVD risk factors such as OxSt and inflammation.
PubMed: 38822597
DOI: 10.1111/aor.14801 -
Journal of Applied Biomaterials &... 2024Adhesions are fibrous tissue connections which are a common complication of surgical procedures and may be prevented by protecting tissue surfaces and reducing...
Adhesions are fibrous tissue connections which are a common complication of surgical procedures and may be prevented by protecting tissue surfaces and reducing inflammation. The combination of biodegradable polymers and nanocrystalline silver can be used to create an anti-inflammatory gel to be applied during surgery. In this study, sodium hyaluronate and sodium carboxymethyl cellulose were added in concentrations from 0.25% to 1% w/v to aqueous nanocrystalline silver solutions to create viscous gels. Gels were loaded into dialysis cassettes and placed in PBS for 3 days. pH was adjusted using potassium phosphate monobasic and sodium hydroxide. Release of silver into the PBS was measured at several time points. Polymer degradation was compared by measuring the viscosity of the gels before and after the experiment. Gels lost up to 84% of initial viscosity over 3 days and released between 24% and 41% of the added silver. Gels with higher initial viscosity did not have a greater degree of degradation, as measured by percent viscosity reduction, but still resulted in a higher final viscosity. Silver release was not significantly impacted by pH or composition, but still varied between experimental groups.
Topics: Hyaluronic Acid; Carboxymethylcellulose Sodium; Hydrogen-Ion Concentration; Silver; Viscosity; Gels; Metal Nanoparticles
PubMed: 38819121
DOI: 10.1177/22808000241257124 -
Turkish Journal of Medical Sciences 2023There are over 60,000 hemodialysis (HD) patients in Türkiye, and the number of patients is increasing yearly. Dialysate flow rate (Qd) is a factor in HD adequacy....
BACKGROUND AND AIM
There are over 60,000 hemodialysis (HD) patients in Türkiye, and the number of patients is increasing yearly. Dialysate flow rate (Qd) is a factor in HD adequacy. Approximately 150 L of water are consumed per session to prepare the dialysate. We aimed to investigate whether HD effectiveness can be achieved at a low Qd in different patient groups for the purpose of saving water.
MATERIALS AND METHODS
This prospective study included 81 HD patients from 2 centers. The patients underwent an aggregate total of 486 HD sessions, including 3 sessions at a Qd of 500 mL/min and 3 sessions at a Qd of 300 mL/min for each patient. We used online Kt/V readings recorded at the end of each dialysis session to compare the effectiveness of these 2 types of HD session performed at a different Qd.
RESULTS
The online Kt/V readings were similar between the standard (500) and low (300) Qd HD (1.51 ± 0.41 and 1.49 ± 0.44, respectively, p = 0.069). In the subgroup analyses, men had higher online Kt/V values at the standard Qd compared to the low Qd (1.35 ± 0.30 and 1.30 ± 0.32, respectively, p = 0.019), but the Kt/V values were not different for women. While the low Qd did not reduce online Kt/V in patients using small surface area dialysis membranes (1.75 ± 0.35 for 300 Qd and 1.75 ± 0.32 for 500 Qd, p = 0.931), it was associated with reduced online Kt/V in patients using large surface area dialysis membranes (1.12 ± 0.25 for 300 Qd and 1.17 ± 0.24 for 500 Qd, p = 0.006). The low Qd did not result in differences in online Kt/V among low-weight patients. However, online Kt/V values were better with the standard Qd in patients weighing 65 kg and above.
CONCLUSION
In our study, dialysis adequacy at a reduced dialysate flow was not inferior for women, patients with low body weight, or patients using small surface area membranes. Individualized HD at a reduced Qd of 300 mL/min in eligible patients can save 48 L of water per HD session and an average of 7500 L of water per year.
Topics: Humans; Renal Dialysis; Female; Male; Prospective Studies; Middle Aged; Aged; Water; Adult; Dialysis Solutions; Kidney Failure, Chronic
PubMed: 38813487
DOI: 10.55730/1300-0144.5756 -
Hemodynamic effects of low versus high dialysate bicarbonate concentration in hemodialysis patients.Hemodialysis International.... May 2024Hemodialysis treatment using standard dialysate bicarbonate concentrations cause transient metabolic alkalosis possibly associated with hemodynamic instability. The aim...
INTRODUCTION
Hemodialysis treatment using standard dialysate bicarbonate concentrations cause transient metabolic alkalosis possibly associated with hemodynamic instability. The aim of this study was to perform a detailed comparison of high and low dialysate bicarbonate in terms of blood pressure, intradialytic hemodynamic parameters, orthostatic blood pressure, and electrolytes.
METHODS
Fifteen hemodialysis patients were examined in a single-blind, randomized, controlled, crossover study. Participants underwent a 4-h hemodialysis session with dialysate bicarbonate concentration of 30 or 38 mmol/L with 1 week between interventions. Blood pressure was monitored throughout hemodialysis, while cardiac output, total peripheral resistance, stroke volume, and central blood volume were assessed with ultrasound dilution technique (Transonic). Orthostatic blood pressure was measured pre- and post-hemodialysis.
FINDINGS
With similar ultrafiltration (UF) volume (2.6 L), systolic blood pressure (SBP) tended to decrease more during high dialysate bicarbonate compared to low dialysate bicarbonate; the mean (95% confidence interval) between treatment differences in SBP were: 8 (-4; 20) mmHg (end of hemodialysis) and 7 (0; 15) mmHg (post-hemodialysis). Stroke volume decreased whereas total peripheral resistance increased significantly more during high dialysate bicarbonate compared to low dialysate bicarbonate with mean between treatment differences: Stroke volume: 12 (1; 23) mL; Total peripheral resistance: -2.9 (-5.3; -0.5) mmHg/(L/min). Cardiac output tended to decrease more with high dialysate bicarbonate compared to low dialysate bicarbonate with mean between treatment difference 0.7 (0.0; 1.4) L/min. High dialysate bicarbonate caused alkalosis, hypocalcemia, and lower plasma potassium, whereas patients remained normocalcemic with normal pH during low dialysate bicarbonate. Orthostatic blood pressure response after dialysis did not differ significantly.
DISCUSSION
The use of high dialysate bicarbonate compared to low dialysate bicarbonate was associated with hypocalcemia, alkalosis, and a more pronounced hypokalemia. During hemodialysis with UF, a better preservation of blood pressure, stroke volume, and cardiac output may be achieved with low dialysate bicarbonate compared to high dialysate bicarbonate.
PubMed: 38803230
DOI: 10.1111/hdi.13162 -
Toxins Apr 2024Chronic kidney disease poses a growing global health concern, as an increasing number of patients progress to end-stage kidney disease requiring kidney replacement... (Review)
Review
Chronic kidney disease poses a growing global health concern, as an increasing number of patients progress to end-stage kidney disease requiring kidney replacement therapy, presenting various challenges including shortage of care givers and cost-related issues. In this narrative essay, we explore innovative strategies based on in-depth literature analysis that may help healthcare systems face these challenges, with a focus on digital health technologies (DHTs), to enhance removal and ensure better control of broader spectrum of uremic toxins, to optimize resources, improve care and outcomes, and empower patients. Therefore, alternative strategies, such as self-care dialysis, home-based dialysis with the support of teledialysis, need to be developed. Managing ESKD requires an improvement in patient management, emphasizing patient education, caregiver knowledge, and robust digital support systems. The solution involves leveraging DHTs to automate HD, implement automated algorithm-driven controlled HD, remotely monitor patients, provide health education, and enable caregivers with data-driven decision-making. These technologies, including artificial intelligence, aim to enhance care quality, reduce practice variations, and improve treatment outcomes whilst supporting personalized kidney replacement therapy. This narrative essay offers an update on currently available digital health technologies used in the management of HD patients and envisions future technologies that, through digital solutions, potentially empower patients and will more effectively support their HD treatments.
Topics: Humans; Renal Dialysis; Telemedicine; Kidney Failure, Chronic; Patient Care; Patient Participation; Self Care; Digital Health
PubMed: 38787063
DOI: 10.3390/toxins16050211 -
Hemodialysis International.... May 2024Progressive clogging of the dialyzer membrane during hemodialysis can compromise solute removal efficiency. Existing solutions fall short in addressing intradialytic...
INTRODUCTION
Progressive clogging of the dialyzer membrane during hemodialysis can compromise solute removal efficiency. Existing solutions fall short in addressing intradialytic reduction of dialyzer clearance. This pilot study aims to assess the impact and safety of applying therapeutic ultrasonic waves to dialyzers for mitigating intradialytic clogging.
METHODS
In this pilot study, 15 stable maintenance hemodialysis patients (12 males and 3 females) were enrolled. Each patient served as their own control. They underwent one session of hemodialysis with the application of therapeutic ultrasonic waves (Ultrasonic session) and were crossed-over to a second session without the use of ultrasonic waves (Control session). All the study sessions operated at a fixed dialysate flow rate of 500 mL/min and a blood flow rate of 250 or 300 mL/min. The adequacy of dialysis achieved during each session was monitored using Online Clearance Monitoring of the dialysis machines, and clearance K values, varying between 135 and 209 mL/min, were recorded, and plotted. A direct comparison between Control and Ultrasonic sessions was performed to assess the impact and safety of using ultrasonic waves during hemodialysis.
FINDINGS
The mean percentage decline in dialyzer clearance values was 4.41% for Ultrasonic sessions (SD: 5.3) and 12.69% for Control sessions (SD: 6.35) (p-value <0.001). This indicates that the application of ultrasonic waves reduced the decline in clearance values. The mean differences of the blood component parameters were comparable between both Ultrasonic sessions and Control sessions, suggesting the safety of utilizing ultrasonic waves during dialysis. Microscopic membrane analysis corroborated the safety.
DISCUSSION
Intradialytic clogging of dialyzer membranes is a significant problem that can cause dialysis inadequacy. Our study tackles this issue by introducing therapeutic ultrasonic waves to improve dialyzer clearance during hemodialysis sessions in patients.
PubMed: 38783838
DOI: 10.1111/hdi.13161 -
GMS Hygiene and Infection Control 2024In Germany, hospitals, rehabilitation facilities and outpatient surgery facilities are required by law to perform antibiotic-consumption surveillance. Established IT...
INTRODUCTION
In Germany, hospitals, rehabilitation facilities and outpatient surgery facilities are required by law to perform antibiotic-consumption surveillance. Established IT programs are available for recording the defined daily doses. These do not exist for long-term care facilities (LTCFs). Antibiotic stewardship is also recommended for LTCFs. In view of the lack of IT solutions for consumption surveillance, this study investigated whether point prevalence studies could be a suitable basis for a data-based antibiotic stewardship program in LTCFs.
METHOD
In May 2023, 18 elderly-care facilities in Berlin, Germany, participated in a point prevalence survey on antibiotic consumption according to the established HALT (healthcare-associated infections in long-term care facilities) method. The number of residents present and their risk factors (including the use of catheters and antibiotic therapy) were recorded. The results were compared with comparable data from previous surveys in LTCFs in Berlin, Germany as well as with the HALT data for Europe as a whole and for Germany.
RESULTS
On the day of the survey, 2040 residents were present, 7.7% of whom bore a urinary catheter and 0.5% a vascular catheter. 0.2% of the residents had a port access, 0.4% a dialysis catheter and one resident (0.05%) a tracheostoma. Twenty-seven (1.3%) residents were receiving an antibiotic on the day of the survey. Of these, 29.6% had a urinary tract catheter. 63.0% of the antibiotics were given for a urinary tract infection, 14.8% for a respiratory tract infection and 11.1% for a wound/soft tissue infection. The overall prevalence of antibiotics was in the range of previous surveys from Germany (1.2-2.4%) and significantly lower than in the Europe-wide HALT survey overall (4.3-4.5%).
DISCUSSION
The survey showed low use of antibiotics in the LTCFs in comparison with Europe-wide surveys. The time required was less than 2 hours for a 100-bed facility. Until appropriate IT programs to determine the defined daily doses are also available for LTCFs, such easy-to-perform and standardized point-prevalence surveys - if repeated several times a year - can be a suitable method for recording the use of antibiotics in nursing homes for the elderly.
PubMed: 38766635
DOI: 10.3205/dgkh000472 -
JMIR Human Factors May 2024Chronic kidney disease affects 10% of the population worldwide, and the number of patients receiving treatment for end-stage kidney disease is forecasted to increase....
Designing for Improved Patient Experiences in Home Dialysis: Usability and User Experience Findings From User-Based Evaluation Study With Patients With Chronic Conditions.
BACKGROUND
Chronic kidney disease affects 10% of the population worldwide, and the number of patients receiving treatment for end-stage kidney disease is forecasted to increase. Therefore, there is a pressing need for innovative digital solutions that increase the efficiency of care and improve patients' quality of life. The aim of the eHealth in Home Dialysis project is to create a novel eHealth solution, called eC4Me, to facilitate predialysis and home dialysis care for patients with chronic kidney disease.
OBJECTIVE
Our study aimed to evaluate the usability, user experience (UX), and patient experience (PX) of the first version of the eC4Me solution.
METHODS
We used a user-based evaluation approach involving usability testing, questionnaire, and interview methods. The test sessions were conducted remotely with 10 patients with chronic kidney disease, 5 of whom had used the solution in their home environment before the tests, while the rest were using it for the first time. Thematic analysis was used to analyze user test and questionnaire data, and descriptive statistics were calculated for the UMUX (Usability Metric for User Experience) scores.
RESULTS
Most usability problems were related to navigation, the use of terminology, and the presentation of health-related data. Despite usability challenges, UMUX ratings of the solution were positive overall. The results showed noteworthy variation in the expected benefits and perceived effort of using the solution. From a PX perspective, it is important that the solution supports patients' own health-related goals and fits with the needs of their everyday lives with the disease.
CONCLUSIONS
A user-based evaluation is a useful and necessary part of the eHealth solution development process. Our study findings can be used to improve the usability and UX of the evaluated eC4Me solution. Patients should be actively involved in the solution development process when specifying what information is relevant for them. Traditional usability tests complemented with questionnaire and interview methods can serve as a meaningful methodological approach for gaining insight not only into usability but also into UX- and PX-related aspects of digital health solutions.
Topics: Humans; Male; Female; Middle Aged; Surveys and Questionnaires; Hemodialysis, Home; Aged; Telemedicine; Patient Satisfaction; Renal Insufficiency, Chronic; User-Computer Interface; Quality of Life; Adult
PubMed: 38743476
DOI: 10.2196/53691 -
International Urology and Nephrology May 2024Incremental peritoneal dialysis (IPD) could decrease unfavorable glucose exposure results and preserve (RKF). However, there is no standardization of dialysis...
PURPOSE
Incremental peritoneal dialysis (IPD) could decrease unfavorable glucose exposure results and preserve (RKF). However, there is no standardization of dialysis prescriptions for patients undergoing IPD. We designed a prospective observational multi-center study with a standardized IPD prescription to evaluate the effect of IPD on RKF, metabolic alterations, blood pressure control, and adverse outcomes.
METHODS
All patients used low GDP product (GDP) neutral pH solutions in both the incremental continuous ambulatory peritoneal dialysis (ICAPD) group and the retrospective standard PD (sPD) group. IPD patients started treatment with three daily exchanges five days a week. Control-group patients performed four changes per day, seven days a week.
RESULTS
A total of 94 patients (47 IPD and 47 sPD) were included in this study. The small-solute clearance and mean blood pressures were similar between both groups during follow-up. The weekly mean glucose exposure was significantly higher in sPD group than IPD during the follow-up (p < 0.001). The patients with sPD required more phosphate-binding medications compared to the IPD group (p = 0.05). The rates of peritonitis, tunnel infection, and hospitalization frequencies were similar between groups. Patients in the sPD group experienced more episodes of hypervolemia compared to the IPD group (p = 0.007). The slope in RKF in the 6th month was significantly higher in the sPD group compared to the IPD group (65% vs. 95%, p = 0.001).
CONCLUSION
IPD could be a rational dialysis method and provide non-inferior dialysis adequacy compared to full-dose PD. This regimen may contribute to preserving RKF for a longer period.
PubMed: 38740705
DOI: 10.1007/s11255-024-04077-7