Cureus May 2024Background The knee is the joint most commonly affected by osteoarthritis, more than any other. Osteoarthritis is a progressive, long-term condition that leads to the...
Background The knee is the joint most commonly affected by osteoarthritis, more than any other. Osteoarthritis is a progressive, long-term condition that leads to the deterioration of joint tissue and cartilage, resulting in pain and impairment. Total knee arthroplasty (TKA) is a successful intervention that improves functional capability, decreases pain, and enhances quality of life. We conducted this study to evaluate whether radiological parameters following TKA influence the clinical outcomes of patients with knee osteoarthritis. Methods The study was conducted on patients treated for knee osteoarthritis at the Department of Orthopedics, Rajindra Hospital and Government Medical College, Patiala, Punjab, in collaboration with the Department of Radiology over a period of 1.5 years. A total of 152 patients diagnosed with knee osteoarthritis were included in the study; all underwent TKA. Patients underwent clinical evaluation and were graded using the Knee Society Score (KSS) during follow-up examinations. Pain was evaluated using the Visual Analog Scale (VAS). Postoperative X-rays were obtained, and various angles, including the distal femoral angle (DFA), the proximal tibial angle (PTA), and the posterior slope angle (PSA), were measured. Patient follow-up was conducted at three days, three months, and six months. Subsequently, a comparison of the clinical and radiological outcomes of TKA was performed. Results In this study, a total of 152 patients participated, with the majority falling into the 61-70 age group. Of these patients, 40.13% were female and 59.87% were male. The average medial DFA was 94.05°, the average medial PTA was 89.31°, and the PSA was 6.6°. Patients with a medial DFA of 94.05° (±3), a medial PTA of 89.31° (±3), and a PSA of 6.6° (±3) were categorized into the normal group. Conclusion Patients with DFA, PTA, and PSA in the normal range demonstrate improved KSS and clinical outcomes.
PubMed: 38910616
DOI: 10.7759/cureus.60933 -
Bone & Joint Open Jun 2024In metal-on-metal (MoM) hip arthroplasties and resurfacings, mechanically induced corrosion can lead to elevated serum metal ions, a local inflammatory response, and...
AIMS
In metal-on-metal (MoM) hip arthroplasties and resurfacings, mechanically induced corrosion can lead to elevated serum metal ions, a local inflammatory response, and formation of pseudotumours, ultimately requiring revision. The size and diametral clearance of anatomical (ADM) and modular (MDM) dual-mobility polyethylene bearings match those of Birmingham hip MoM components. If the acetabular component is satisfactorily positioned, well integrated into the bone, and has no surface damage, this presents the opportunity for revision with exchange of the metal head for ADM/MDM polyethylene bearings without removal of the acetabular component.
METHODS
Between 2012 and 2020, across two centres, 94 patients underwent revision of Birmingham MoM hip arthroplasties or resurfacings. Mean age was 65.5 years (33 to 87). In 53 patients (56.4%), the acetabular component was retained and dual-mobility bearings were used (DM); in 41 (43.6%) the acetabulum was revised (AR). Patients underwent follow-up of minimum two-years (mean 4.6 (2.1 to 8.5) years).
RESULTS
In the DM group, two (3.8%) patients underwent further surgery: one (1.9%) for dislocation and one (1.9%) for infection. In the AR group, four (9.8%) underwent further procedures: two (4.9%) for loosening of the acetabular component and two (4.9%) following dislocations. There were no other dislocations in either group. In the DM group, operating time (68.4 vs 101.5 mins, p < 0.001), postoperative drop in haemoglobin (16.6 vs 27.8 g/L, p < 0.001), and length of stay (1.8 vs 2.4 days, p < 0.001) were significantly lower. There was a significant reduction in serum metal ions postoperatively in both groups (p < 0.001), although there was no difference between groups for this reduction (p = 0.674 (cobalt); p = 0.186 (chromium)).
CONCLUSION
In selected patients with Birmingham MoM hips, where the acetabular component is well-fixed and in a satisfactory position with no surface damage, the metal head can be exchanged for polyethylene ADM/MDM bearings with retention of the acetabular prosthesis. This presents significant benefits, with a shorter procedure and a lower risk of complications.
PubMed: 38910515
DOI: 10.1302/2633-1462.56.BJO-2023-0165.R1 -
The Journal of Foot and Ankle Surgery :... Jun 2024Different aspects of the learning curve in Total Ankle Replacement (TAR) have been studied in the short to mid-term, with 30 cases often considered critical. However,...
Different aspects of the learning curve in Total Ankle Replacement (TAR) have been studied in the short to mid-term, with 30 cases often considered critical. However, its impact on long-term (10 and 15-year) survival remains unclear. Therefore, we retrospectively analyzed 77 consecutive TARs performed by one orthopedic surgeon. The main outcome was long-term survival between cases 1-30 and 31-77 using the Kaplan-Meier with Competing Risk Analyses. Secondarily, we used Moving Average Method with LOESS regression to confirm the learning curve based on the perioperative complications. Thirdly, associations between perioperative complications and operation time on long-term survival were assessed using Cox proportional hazard models. The 10-year survival of cases 1-30 was 89.9% (95% CI 70.4-96.5), and of 31-77, 92.4% (95% CI 7745- 97.5) (p = 0.58). The 15-year survival was 81.8% (95% CI 59.5-91.8) and 74.8% (95% CI 52.4-86.6), respectively (p = 0.97). The long-term survival rate for the TAR that endured perioperative complication was 96.70% (95% CI 90.28-103.12), and for the uncomplicated TAR 87.50% (95% CI 77.12-97.88%) (p=0.24). Operating time nor occurrence of perioperative fractures were significantly associated with long-term survival (p= 0.11 and 0.26, respectively). However, moving average method revealed a significant decreasing trend with a cut-off value of 33 procedures regarding the marginal probability of perioperative osseous complications (p<0.01). In conclusion, surgeons should note a learning curve when adapting arthroplasty procedures. After the prosthesis design switch, the learning curve regarding perioperative osseous complications was confirmed at 33 TAR. The switch did not affect long-term survival.
PubMed: 38909964
DOI: 10.1053/j.jfas.2024.06.002 -
The Journal of Arthroplasty Jun 2024This study reports the minimum 10 year results of total hip arthroplasty (THA) performed using a monoblock acetabular component with a large-diameter head (LDH)...
AIMS
This study reports the minimum 10 year results of total hip arthroplasty (THA) performed using a monoblock acetabular component with a large-diameter head (LDH) ceramic-on-ceramic (CoC) bearing.
METHODS
Of the 276 THAs included in this study, 237 (85%) were available for review at a mean of 10.5 years (range, 10 to 12) postoperatively. There were eleven deaths that occurred during the follow-up. Reoperations, implant revisions, adverse events, clinical outcomes, radiographic evaluation, and whole blood metal ion levels were assessed at the last follow-up.
RESULTS
After a minimum of 10 years, implant survivorship was 98.7%. There were three revisions (1.3%): one for insufficient acetabular cup primary fixation, one traumatic periprosthetic acetabular fracture, and one probable deep chronic infection. No dislocation or ceramic implant fracture was observed. The mean University of California at Los Angeles (UCLA) activity score, Western Ontario and McMaster Universities Osteoarthritis Index score, and Forgotten Joint Score were 5.6 (2 to 10), 90.1 (9 to 100), and 79.2 (4 to 100), respectively. In the 10 years following implantation, at least 43% of patients reported hearing a squeaking noise from the prosthesis. All patients who had squeaking hips were satisfied with the surgery. The mean titanium level was 2.2 μg/L (1.1 to 5.6). No progressive radiolucent lines, osteolysis, or implant loosening signs were observed at the last radiographic evaluation.
CONCLUSION
A LDH CoC THA provides outstanding long-term (minimum 10 year) implant survivorship with unrestricted activity while avoiding implant impingement, liner fracture, and hip instability. Functional outcomes, satisfaction, and joint perception were excellent. Although the incidence of squeaking was high, it did not affect patient satisfaction or function. The systemic titanium levels were low, related to unavoidable passive corrosion of implant surfaces, and did not reveal any indirect signs of trunnionosis.
PubMed: 38909852
DOI: 10.1016/j.arth.2024.06.045 -
Perioperative Medicine (London, England) Jun 2024Preoperative anaemia including iron deficiency anaemia (IDA) is a well-established perioperative risk factor. However, most studies on iron therapy to treat IDA have... (Review)
Review
BACKGROUND AND PURPOSE
Preoperative anaemia including iron deficiency anaemia (IDA) is a well-established perioperative risk factor. However, most studies on iron therapy to treat IDA have been negative and few have been conducted within an enhanced recovery after surgery (ERAS) protocol. Furthermore, patients with IDA often have comorbidities not necessarily influenced by iron, but potentially influencing traditional study endpoints such as length of stay (LOS), morbidity, etc. The aim of this paper is to discuss patient-related challenges when planning outcome studies on the potential benefits of iron therapy in patients with IDA, based upon a large detailed prospective database in ERAS total hip (THA) and knee arthroplasty (TKA).
METHODS
A prospective observational cohort study in ERAS THA and TKA from 2022 to 2023. Detailed complete follow-up through questionnaires and electronic medical records.
RESULTS
Of 3655 included patients, 276 (7.6%) had IDA defined as a haemoglobin (Hb) of < 13.0 g/dL and transferrin saturation of 0.20, while 3379 had a Hb of ≥ 13.0. Patients with IDA were a median 5 years older than non-anaemics, with an increased fraction living alone (38.4% vs. 28.8%), using walking aids (54.3% vs 26.4%) and receiving home care (16.2% vs 4.7%). Fewer IDA patients were working (12.7% vs. 29.6%) and a median number of prescribed drugs was higher (10 vs. 6). Median LOS was 1 day in both IDA and non-anaemic patients, but a LOS of > 2 days occurred in 11.6% of patients with IDA vs. 4.3% in non-anaemics. The proportion with 30- or 90-day readmissions was 6.5% vs. 4.1% and. 13.4% vs6.0%, in patients with IDA and non-anaemics, respectively. However, potentially anaemia or iron deficiency-related causes of LOS > 2 days or 90-day readmissions were only 5.4% and 2.2% in patients with IDA and 1.9% and 1.0% in non-anaemics.
CONCLUSION
Conventional randomised trials with single or composite "hard" endpoints are at risk of being inconclusive or underpowered due to a considerable burden of other patient-related risk factors and with postoperative complications which may not be modifiable by correction of IDA per se. We will propose to gain further insights from detailed observational and mechanistic studies prior to initiating extensive randomised studies.
PubMed: 38907322
DOI: 10.1186/s13741-024-00426-3 -
Arthroplasty (London, England) Jun 2024The use of long stems for severe femoral bone defects is suggested by many scholars, but it is associated with further bone loss, intraoperative fracture, increased...
BACKGROUND
The use of long stems for severe femoral bone defects is suggested by many scholars, but it is associated with further bone loss, intraoperative fracture, increased surgical trauma, and complications. With better bone retention, simple and quick surgical procedures, and minimal complications, the short cementless stems with a tapered rectangular shape may be an alternative for femoral revision. This study aimed to evaluate the results of this type of stem in treating selected Paprosky II-IV bone defects.
METHODS
This retrospective study included 73 patients (76 hips involved) who underwent conservative femoral revision using the short cementless stems with a tapered rectangular shape between January 2012 and December 2020. The preoperative femoral bone defects were identified as follows: 54 cases of type II, 11 cases of type IIIA, 7 cases of type IIIB, and 4 cases of type IV. Indications for revision included aseptic loosening (76.3%) and prosthetic joint infection (23.7%). Six cementless stems with a tapered rectangular shape from three companies were used in all patients. Among them, SLR-Plus, SL-Plus MIA, and Corail stems were employed in most patients (40.8%, 23.7%, and 17.1%, respectively). The average length of these stems measured 171.7 mm (SD 27 mm; 122-215 mm). Radiographic results, Harris hip scores (HHS), complications, and survivorship were analyzed. The follow-up lasted for 7 years on average (range 3-11 years).
RESULTS
The subsidence was observed in three hips (3.9%), and all stems achieved stable bone ingrowth. Proximal femoral bone restoration in the residual osteolytic area was found in 67 hips (88.2%), constant defects in nine hips (11.8%), and increasing defects in 0 cases. There was no evidence of stem fractures and stem loosening in this series. The mean HHS significantly improved from 32 (range 15-50) preoperatively to 82 (range 68-94) at the last follow-up (t = - 36.297, P < 0.001). Five hips developed prosthesis-related complications, including three infection and two dislocation cases. The mean 5- and 10-year revision-free survivorships for any revision or removal of an implant and reoperation for any reason were 94.6% and 93.3%, respectively. Both mean 5- and 10-year revision-free survivorships for aseptic femoral loosening were 100%.
CONCLUSION
Conservative femoral revision using short cementless stems with a tapered rectangular shape can provide favorable radiographic outcomes, joint function, and mid-term survivorship with minimal complications. Of note, a sclerotic proximal femoral bone shell with continued and intact structure and enough support strength is the indication for using these stems.
PubMed: 38907318
DOI: 10.1186/s42836-024-00251-5 -
International Journal of Surgery... Jun 2024The advent of personalized bone prosthesis materials and their integration into orthopedic surgery has made a profound impact, primarily as a result of the incorporation...
The advent of personalized bone prosthesis materials and their integration into orthopedic surgery has made a profound impact, primarily as a result of the incorporation of three-dimensional (3D) printing technology. By leveraging digital models and additive manufacturing techniques, 3D printing enables the creation of customized, high-precision bone implants tailored to address complex anatomical variabilities and challenging bone defects. In this review, we highlight the significant progress in utilizing 3D printed prostheses across a wide range of orthopedic procedures, including pelvis, hip, knee, foot, ankle, spine surgeries, and bone tumor resections. The integration of 3D printing in preoperative planning, surgical navigation, and postoperative rehabilitation not only enhances treatment outcomes but also reduces surgical risks, accelerates recovery, and optimizes cost-effectiveness. Emphasizing the potential for personalized care and improved patient outcomes, this review underscores the pivotal role of 3D printed bone prosthesis materials in advancing orthopedic practice towards precision, efficiency, and patient-centric solutions. The evolving landscape of 3D printing in orthopedic surgery holds promise for revolutionizing treatment approaches, enhancing surgical outcomes, and ultimately improving the quality of care for orthopedic patients.
PubMed: 38905508
DOI: 10.1097/JS9.0000000000001842 -
Medicine Jun 2024This study aims to visualize publications related to venous thromboembolism (VTE) and lower limb joint arthroplasty to identify research frontiers and hotspots,...
This study aims to visualize publications related to venous thromboembolism (VTE) and lower limb joint arthroplasty to identify research frontiers and hotspots, providing references and guidance for further research. We retrieved original articles published from 1985 to 2022 and their recorded information from the Web of Science Core Collection. The search strategy used terms related to knee or hip arthroplasty and thromboembolic events. Microsoft Excel was used to analyze the annual publications and citations of the included literature. The rest of the data were analyzed using the VOSviewer, citespace and R and produced visualizations of these collaborative networks. We retrieved 3543 original articles and the results showed an overall upward trend in annual publications. The United States of America had the most significant number of publications (Np) and collaborative links with other countries. McMaster University had the greatest Np. Papers published by Geerts WH in 2008 had the highest total link strength. Journal of Arthroplasty published the most articles on the research of VTE associated with lower limb joint arthroplasty. The latest research trend mainly involved "general anesthesia" "revision" and "tranexamic acid." This bibliometric study revealed that the research on VTE after lower limb joint arthroplasty is developing rapidly. The United States of America leads in terms of both quantity and quality of publications, while European and Canadian institutions and authors also make significant contributions. Recent research focused on the use of tranexamic acid, anesthesia selection, and the VTE risk in revision surgeries.
Topics: Humans; Bibliometrics; Venous Thromboembolism; Arthroplasty, Replacement, Knee; Arthroplasty, Replacement, Hip; Biomedical Research; Postoperative Complications; Lower Extremity
PubMed: 38905398
DOI: 10.1097/MD.0000000000038661 -
Ugeskrift For Laeger Jun 2024Total knee arthroplasty is a frequently performed orthopaedic surgery and the trend indicates an increase in annual procedures. Many patients experience severe... (Review)
Review
Total knee arthroplasty is a frequently performed orthopaedic surgery and the trend indicates an increase in annual procedures. Many patients experience severe postoperative pain. In this review article, a review of the literature reveals evidence supporting a multimodal approach to pain management, which involves basic analgesic treatment in combination with glucocorticoids and local infiltration analgesia. Effective pain control can reduce postoperative pain, lower opioid consumption, and its associated adverse effects, and enhance postoperative rehabilitation and patient satisfaction.
Topics: Humans; Arthroplasty, Replacement, Knee; Pain, Postoperative; Analgesics; Pain Management; Glucocorticoids; Analgesics, Opioid; Anesthetics, Local
PubMed: 38904286
DOI: 10.61409/V10230664 -
Scientific Reports Jun 2024To understand the status of sedentary behaviour in elderly patients after total knee arthroplasty and analyse its influencing factors so as to provide a reference for...
To understand the status of sedentary behaviour in elderly patients after total knee arthroplasty and analyse its influencing factors so as to provide a reference for developing targeted interventions. Conveniently selected elderly patients undergoing total knee arthroplasty (> 6 months) in a tertiary hospital in Jiangsu Province were investigated using a general information questionnaire, the Charlson Comorbidity Index, patients' self-reported sedentary behaviour information, the WOMAC Score, The Groningen Orthopaedic Social Support Scale, and Lee's Fatigue. The median daily sedentary time was 5.5 h (4.5 h, 6.625 h) in 166 elderly patients after total knee arthroplasty, of whom 82 (49.40%) showed sedentary behaviour (≥ 6 h per day). Logistic regression analysis showed that being retired/unemployed (OR = 8.550, 95% CI 1.732-42.207, P = 0.0084), having a CCI score ≥ 3 (OR = 9.018, 95% CI 1.288-63.119, P < 0.0001), having high WOMAC scores (OR = 1.783, 95% CI 1.419-2.238, P < 0.0001), having a high social support score (OR = 1.155, 95% CI 1.031-1.294, P = 0.0130), and having a fatigue score ≥ 5 (OR = 4.848, 95% CI 1.084-21.682, P = 0.0389) made patients more likely to be sedentary. The sedentary time of elderly patients after total knee arthroplasty is long, and sedentary behaviour is common among them. Healthcare professionals should develop targeted sedentary behaviour interventions based on the influencing factors of sedentary behaviour in order to reduce the occurrence of sedentary behaviour in elderly patients after total knee arthroplasty.
Topics: Humans; Arthroplasty, Replacement, Knee; Sedentary Behavior; Male; Female; Aged; Surveys and Questionnaires; Aged, 80 and over; Middle Aged; Risk Factors; Social Support
PubMed: 38902382
DOI: 10.1038/s41598-024-64836-5