World Journal of Critical Care Medicine Jun 2024Discerning the etiology of acute kidney injury (AKI) in cirrhotic patients remains a formidable challenge due to diverse and overlapping causes. The conventional... (Review)
Review
Discerning the etiology of acute kidney injury (AKI) in cirrhotic patients remains a formidable challenge due to diverse and overlapping causes. The conventional approach of empiric albumin administration for suspected volume depletion may inadvertently lead to fluid overload. In the recent past, point-of-care ultrasonography (POCUS) has emerged as a valuable adjunct to clinical assessment, offering advantages in terms of diagnostic accuracy, rapidity, cost-effectiveness, and patient satisfaction. This review provides insights into the strategic use of POCUS in evaluating cirrhotic patients with AKI. The review distinguishes basic and advanced POCUS, emphasizing a 5-point basic POCUS protocol for efficient assessment. This protocol includes evaluations of the kidneys and urinary bladder for obstructive nephropathy, lung ultrasound for detecting extravascular lung water, inferior vena cava (IVC) ultrasound for estimating right atrial pressure, internal jugular vein ultrasound as an alternative to IVC assessment, and focused cardiac ultrasound for assessing left ventricular (LV) systolic function and identifying potential causes of a plethoric IVC. Advanced POCUS delves into additional Doppler parameters, including stroke volume and cardiac output, LV filling pressures and venous congestion assessment to diagnose or prevent iatrogenic fluid overload. POCUS, when employed judiciously, enhances the diagnostic precision in evaluating AKI in cirrhotic patients, guiding appropriate therapeutic interventions, and minimizing the risk of fluid-related complications.
PubMed: 38855271
DOI: 10.5492/wjccm.v13.i2.93812 -
Anales de Pediatria Jun 2024
Topics: Humans; Jugular Veins; Dilatation, Pathologic; Male; Female; Child
PubMed: 38853060
DOI: 10.1016/j.anpede.2024.05.010 -
Surgical and Radiologic Anatomy : SRA Jul 2024This study aims to assess the anatomical possibilities of the jugular bulb (JB).
PURPOSE
This study aims to assess the anatomical possibilities of the jugular bulb (JB).
METHODS
Fifty archived CBCT scans were analyzed.
RESULTS
The average distance between the internal acoustic canal (IAC) and the JB was 7.97 mm on both sides (Right: SD = 2.56 mm, range 3.16-13.3 mm; Left: SD = 2.5 mm, range 2.9-13.6 mm). JB walls' pneumatization was classified into eight patterns. Deep petrosal cells (DPCs) prevailed in the lateral wall of the JB. The absence of pneumatization (NP) was commonly found on the left side. The presence of infralabyrinthine and hypotympanic cells varied. Less common types included accessory occipital cells (AOCs), posteromedial tracts (PMTs), and basi-occipital cells (BOCs), which determined a consistent variation of the lateral wall pneumatization patterns. Pneumatization of the medial wall was not observed in 50 right sides and 49 left sides. The inferior wall analysis revealed symmetry in AOC distribution and a predominant occurrence of NP. Cases with hypotympanum (HT) in the lateral wall showed a statistically significant IAC-JB distance increase by an average of 4.67 mm compared to NPs. Specific pneumatizations, particularly HT on the lateral side, have a significant effect on the IAC-JB distance, showing a clear pattern of increasing distance from DPC to NP and then to HT. A significant distance increase in HT pneumatization was noted. There were also recorded instances of JB hypoplasia and hyperplasia, JB diverticula, dehiscent JBs, and high JBs.
CONCLUSION
This study establishes a novel classification of JB pneumatizations to aid in the understanding of the temporal bone anatomy.
Topics: Humans; Anatomic Variation; Cone-Beam Computed Tomography; Female; Male; Adult; Middle Aged; Aged; Jugular Veins; Adolescent; Young Adult; Jugular Foramina; Aged, 80 and over; Retrospective Studies
PubMed: 38847825
DOI: 10.1007/s00276-024-03401-1 -
Cureus May 2024Percutaneous central venous catheterization, despite ultrasound guidance, is known to carry significant risks. While central venous catheters are widely used in clinical...
Percutaneous central venous catheterization, despite ultrasound guidance, is known to carry significant risks. While central venous catheters are widely used in clinical practice, they are also associated with various complications, including incorrect positioning during insertion. Arterial puncture is a well-recognized complication, and although unintended subclavian or carotid artery cannulation is rare, it can lead to serious consequences. We present two cases, in which a dual-lumen, non-tunneled temporary hemodialysis catheter was inadvertently inserted into the left common carotid artery and in the left innominate vein.
PubMed: 38846204
DOI: 10.7759/cureus.59814 -
Indian Journal of Dermatology 2024
PubMed: 38841239
DOI: 10.4103/ijd.ijd_1101_23 -
The Journal of the Canadian... Apr 2024Axillary-subclavian venous thrombosis (ASVT) is a type of upper extremity deep vein thrombosis (UEDVT). UEDVTs are classified as either primary or secondary depending on...
BACKGROUND
Axillary-subclavian venous thrombosis (ASVT) is a type of upper extremity deep vein thrombosis (UEDVT). UEDVTs are classified as either primary or secondary depending on their etiology. Although uncommon, clinicians should be aware of the clinical presentation of UEDVT as timely diagnosis and early treatment is critical in preventing possible post-thrombotic complications.
CASE PRESENTATION
We report a rare case of axillary-subclavian and internal jugular vein thrombosis in the absence of clear risk factors in a 78-year-old male weightlifter who presented to the office with two-week duration of left upper extremity pain and swelling following strenuous exercise at the gym.
SUMMARY
The combination of unusual thrombi location, in addition to the unusual absence of existing thoracic-outlet compression or indwelling medical hardware, makes our case of UEDVT especially uncommon. Clinicians should be aware of this rare disease due to the debilitating effects both in the short and long term.
PubMed: 38840961
DOI: No ID Found -
The Journal of Vascular Access Jun 2024To investigate the technical advantages of a modified no-touch technique (MNTT) in constructing arteriovenous fistulas (AVF) compared to the conventional technique (CT)...
BACKGROUND
To investigate the technical advantages of a modified no-touch technique (MNTT) in constructing arteriovenous fistulas (AVF) compared to the conventional technique (CT) and assess its potential to reduce neointimal hyperplasia in the outflow vein.
METHODS
Forty-seven New Zealand rabbits were randomly divided into three groups: control, CT, and MNTT. Rabbits in control group were observed using ultrasound and then euthanized to obtain external jugular vein (EJV) for Hematoxylin-eosin (H-E). We established common carotid artery (CCA)-EJV AVF using MNTT in the MNTT group and the CT in the CT group. AVF patency and complications were compared between the CT and MNTT groups. Rabbits with patent AVF in both groups were observed using ultrasound 2 weeks after surgery to evaluate changes in the vessel diameter and blood flow spectrum of the AVFs. H-E staining measured the intima thickness of EJV adjacent to the anastomosis and histologic characteristics of the AVF at 2 and 4 weeks after surgery.
RESULTS
Five rabbits died after surgery with common symptoms of sneezing, coughing, runny nose, anorexia, and diarrhea; two in the MNTT group and three in the CT group. There were significant differences in the diameter ( = 0.010) and peak systolic velocities (PSV) ( = 0.001) of EJV between the CT and MNTT groups 2 weeks after surgery. Spiral laminar flow (SLF) was observed in CCA and EJV adjacent to anastomosis in the MNTT group. Additionally, histological observations showed less venous neointimal hyperplasia in the MNTT group than in the CT group 4 weeks after surgery.
CONCLUSION
The rabbit model of CCA-EJV AVF established using MNTT demonstrated fewer comlications, larger vein diameters, and reduced venous neointimal hyperplasia, indicating that this maybe an ideal animal model to further investigate the application of MNTT in AVF surgery.
PubMed: 38836593
DOI: 10.1177/11297298241256172 -
The American Journal of Forensic... May 2024A common treatment for venous thromboembolic disease in patients with contraindications to anticoagulation includes placement of an inferior vena cava (IVC) filter....
A common treatment for venous thromboembolic disease in patients with contraindications to anticoagulation includes placement of an inferior vena cava (IVC) filter. Temporary filters are available to avoid the risk of long-term permanent placement. A woman in her 60s with a history of uterine serous carcinoma presented to the emergency department with cardiac arrest following elective attempted IVC filter removal. Three months prior, a temporary filter was placed because anticoagulation medication was stopped in preparation for a hysterectomy. During the IVC retrieval procedure, which was performed using an intravascular approach from the right jugular vein, the filter was tilted, requiring the use of a different retrieval sheath. During catheter reentry, the patient complained of discomfort in the chest and neck, after which she became hypotensive, lost consciousness, and died. Autopsy revealed 2 cardiac perforations, one in each ventricle. Approximately 600 mL of liquid and clotted blood was within the tense pericardial sac. An IVC filter was found in place, with no adjacent hemorrhage.To our knowledge, this is the first reported fatality due to cardiac perforation by an access sheath during intravascular removal of an IVC filter. This instance also documents the time course of the cardiac perforations to the resultant loss of consciousness.
PubMed: 38833346
DOI: 10.1097/PAF.0000000000000947 -
SAGE Open Medicine 2024We explored the differences in deep venous catheterization-associated complications between patients with hematological malignancies after peripherally inserted central...
A retrospective cohort study of implantable venous access port-related and peripherally inserted central catheter-related complications in patients with hematological malignancies in China.
OBJECTIVE
We explored the differences in deep venous catheterization-associated complications between patients with hematological malignancies after peripherally inserted central catheter placement and such patients after implantable venous access port catheterization.
INTRODUCTION
peripherally inserted central catheters and implantable venous access ports are the most popular devices used for chemotherapy. However, no study has revealed differences between peripherally inserted central catheters and implantable venous access ports in Chinese patients with hematological malignancies.
METHODS
The clinical data of 322 patients with hematological malignancies who were treated from January 1, 2020 to December 30, 2021 were included in a retrospective cohort study. Postoperative color Doppler ultrasonography and follow-up results were used to compare the incidence rates of deep venous catheterization -associated complications after peripherally inserted central catheters and implantable venous access ports catheterization.
RESULTS
The relative risk of catheter-related complications considering the type of device was 8.3 (95% CI = 3.0-22.8). In addition, chi-square segmentation analysis revealed a significant difference in the complication rate between the internal jugular vein and the basilic vein (χ = 22.002, < 0.0001) and between the subclavian vein and the basilic vein (χ = 28.940, < 0.0001).
CONCLUSION
Implantable venous access ports are safer than peripherally inserted central catheters for Chinese patients with hematological malignancies. The implantation of implantable venous access ports could be firstly considered for systematic anti-cancer treatment.
PubMed: 38826826
DOI: 10.1177/20503121241257190 -
Cureus Apr 2024The prolonged use of hemodialysis catheters is associated with several complications with infection being the most common. The increased susceptibility to infections in...
The prolonged use of hemodialysis catheters is associated with several complications with infection being the most common. The increased susceptibility to infections in patients on hemodialysis can be attributed to decreased immunity, though age, other comorbidities, and properties of the catheter act as modifiers. Hematogenous spread of the infection can lead to sepsis and seeding into other organs. In this article, we report an unusual case of septic emboli to the brain in a 30-year-old male on prolonged use of a right internal jugular vein (IJV) catheter for hemodialysis. An interesting finding in the case was the presence of a patent foramen ovale (PFO), a persisting embryonic structure that allows right-to-left shunting. It is suspected that this PFO led to the passage of septic emboli from the right IJV site to the brain. Before our case, septic emboli to the brain have been reported to occur from valvular vegetation in case of infective endocarditis. The mainstay of managing patients with septic emboli is the use of antibiotics; additional interventions may be needed on a case-to-case basis.
PubMed: 38826600
DOI: 10.7759/cureus.59419