-
Biomaterials Advances Feb 2023Despite advances in bone tissue engineering, fabricating a scaffold which can be used as an implant for large bone defects remains challenge. One of the great importance...
Despite advances in bone tissue engineering, fabricating a scaffold which can be used as an implant for large bone defects remains challenge. One of the great importance in fabricating a biomimetic bone implant is considering the possibility of the integration of the structure and function of implants with hierarchical structure of bone. Herein, we propose a method to mimic the structural unit of compact bone, osteon, with spatial pattern of human umbilical vein endothelial cells (HUVECs) and human mesenchymal stem cells (hMSCs) in the adjacent layers that mimic Haversian canal and lamella, respectively. To this end, coaxial extrusion-based bioprinting technique via a customized quadruple-layer core-shell nozzle was employed. 3D implant scaffold-cell construct was fabricated by using polyethylene glycol as a hollowing agent in the first layer, gelatin methacryloyl (GelMA) and alginate blended hydrogel encapsulating HUVEC cells with vascular endothelial growth factor nanoparticles in the second layer (vasculogenic layer) to mimic vascular vessel, and GelMA and alginate blended hydrogel containing hMSCs cells in the outer osteogenic layer to imitate lamella. Two types of bone minerals, whitlockite and hydroxyapatite, were incorporated in osteogenic layer to induce osteoblastic differentiation and enhance mechanical properties (the young's modules of nanocomposite increased from 35 kPa to 80 kPa). In-vitro evaluations demonstrated high cell viability (94 % within 10 days) and proliferation. Furthermore, ALP enzyme activity increased considerably within 2 weeks and mineralized extra cellular matrix considerably produced within 3 weeks. Also, a significant increase in osteogenic markers was observed indicating the presence of differentiated osteoblast cells. Therefore, the work indicates the potential of single step 3D bioprinting process to fabricate biomimetic osteons to use as bone grafts for regeneration.
Topics: Humans; Alginates; Bioprinting; Haversian System; Human Umbilical Vein Endothelial Cells; Hydrogels; Nanogels; Tissue Scaffolds; Vascular Endothelial Growth Factor A; Printing, Three-Dimensional
PubMed: 36584583
DOI: 10.1016/j.bioadv.2022.213254 -
ACS Applied Materials & Interfaces Dec 2022Surface modification is an effective method to resolve the biocompatibility, mechanical, and functional issues of various titanium implant materials. Therefore, many...
Surface modification is an effective method to resolve the biocompatibility, mechanical, and functional issues of various titanium implant materials. Therefore, many researchers have modified the implant surface to promote the osseointegration of the implant and improve the implant survival rate. In this study, we used photolithography to construct concentric microgrooves with widths of 10 μm and depths of 10 μm, to produce an osteon-mimetic concentric microgrooved titanium surface that was further modified with graphene oxide by silanization (GO-CMS). The modified surface had great biocompatibility and promoted the proliferation of bone marrow-derived mesenchymal stem cells (BMSCs) and RAW264.7 macrophages. The concentric microgrooves on the titanium surface guided cell migration, altered actin cytoskeleton, and caused the cells to arrange in concentric circles. The titanium surface of the GO-modified osteon-mimetic concentric microgrooves promoted the osteogenic differentiation of BMSCs and inhibited the osteoclastogenic differentiation of RAW264.7 cells. Subsequently, we constructed an indirect coculture system and found that RAW264.7 cells cultured on a GO-CMS material surface in a BMSC-conditioned medium (BCM) decreased receptor activator of nuclear factor-κB ligand (RANKL) secretion and increased OPG secretion and also that the BCM inhibited osteoclastogenic differentiation. Additionally, the secretion of OSM increased in BMSCs cultured in RAW264.7-conditioned medium (RCM) in the GO-CMS group, which in turn promoted the osteogenic differentiation of BMSCs. In conclusion, the titanium surface of GO-modified osteon-mimetic concentric microgrooves had dual effects of osteogenesis and antiosteoclastogenesis under single and coculture conditions, which is beneficial for implant osseointegration and is a promising method for the future direction of surface modifications of implants.
Topics: Osteogenesis; Titanium; Culture Media, Conditioned; Surface Properties; Osseointegration; Cell Differentiation
PubMed: 36454650
DOI: 10.1021/acsami.2c14271 -
Applied Bionics and Biomechanics 2022Cortical bone is a transversely isotropic material, and the mechanical properties may be related to the loading direction on the osteon. Therefore, analyzing the...
Cortical bone is a transversely isotropic material, and the mechanical properties may be related to the loading direction on the osteon. Therefore, analyzing the differences in the failure processes of cortical bone under different loading conditions is necessary to explore the measures for reducing the incidence of fracture. In this study, to investigate the effects of different loading directions on the fracture performance in the cortical bone, a numerical method that could simultaneously simulate the failure processes in the cortical bone structure under compression and bending loads was established based on continuum damage mechanics theory. The prediction accuracy and feasibility of the numerical method were first verified by comparing with the corresponding experimental results. Then, the differences in the failure process and fracture performance of the same cortical bone structure under compression and bending loads were investigated. The simulation results indicated that for the same structure, the slip-open failure mode appeared under compression load, and the crack propagated along a certain angle to the loading direction; the tension-open failure mode appeared under bending load, and the crack propagated along the direction perpendicular to the loading direction. Meanwhile, the fracture load was greater and the fracture time was later in the compression than in the bending condition. These phenomena stated that discrepant failure processes and fracture patterns occurred in the same cortical bone structure under different loading conditions. The main reason may be related to the tension-compression asymmetry and transversely isotropic characteristics in the cortical bone material. The fracture simulations in the cortical bone under different loading conditions could improve the prediction accuracy in bone biomechanics and provide the prevention method for cortical bone damage and fracture.
PubMed: 36439555
DOI: 10.1155/2022/3406984 -
Journal of the Mechanical Behavior of... Feb 2023Three-dimensional multi-scale finite element models were designed to examine the effects of geometrical structure variations on the damage onset in cortical bone at...
Three-dimensional multi-scale finite element models were designed to examine the effects of geometrical structure variations on the damage onset in cortical bone at multiple structural scales. A cohesive zone finite element approach, together with anisotropic damage initiation criteria, is used to predict the onset of damage. The finite element models are developed to account for the onset of microdamage from the microscopic length scales consisting of collagen fibres, to the macroscopic level consisting of osteons and the Haversian canals. Numerical results indicated that the yield strain at the initiation of microcracks is independent of variations in the local mineral volume fraction at each structural scale. Further, the yield strain and strength properties of cortical bone are dependent on its structural anisotropy and hierarchical structure. A positive correlation is observed between bone strength and mineral content at each length scale.
Topics: Finite Element Analysis; Bone and Bones; Cortical Bone; Haversian System; Minerals; Stress, Mechanical
PubMed: 36427415
DOI: 10.1016/j.jmbbm.2022.105578 -
Biology Nov 2022Histomorphometry constitutes a valuable tool for age estimation. Histological interpopulation variability has been shown to affect the accuracy of age estimation...
Histomorphometry constitutes a valuable tool for age estimation. Histological interpopulation variability has been shown to affect the accuracy of age estimation techniques and therefore validation studies are required to test the accuracy of the pre-existing methodologies. The present research constitutes a validation study of widely known histological methods on the sixth rib and the femoral midshaft of a 19th century British population originating from Blackburn, England. An evaluation of the histomorphometric features of eleven ribs and five femora was performed and used to test the accuracy of selected methods. Results indicated that osteon area and circularity were the only histomorphometric variables that presented significant interpopulation variability. Cho et al.'s method for the ribs and the average value produced using Kerley and Ubelaker's method for intact osteon and percentage of lamellar bone equations for femur were considered the only reliable markers for estimating the age on the Blackburn sample. In the case of old individuals, Goliath et al.'s method provided more satisfactory results. Overall, the present study provides evidence on the applicability of the aging histomorphometric methods on a British sample and highlights the limitations of applying histomorphometric methods developed on different reference populations than the one under investigation.
PubMed: 36358316
DOI: 10.3390/biology11111615 -
Biology Oct 2022Whole-body donations (n = 6) were placed in various experimental fire-death scenarios to understand the histological effects of thermal alteration on bones and teeth....
Whole-body donations (n = 6) were placed in various experimental fire-death scenarios to understand the histological effects of thermal alteration on bones and teeth. Midshaft samples of the femur, 6th rib, and metatarsal were removed from each donor pre- and post-burning to examine histomorphometric differences and test established age-at-death estimation methods. Dental samples were taken post-burning to test the applicability of dental cementum analysis for age-at-death estimation. Significant differences in osteon area or Haversian canal area between some pre- and post-burn samples were found although no patterns related to temperature or element were observable. The femoral age estimates across pre- and post-burn samples were 91% accurate across all donors. The point age estimates from the ribs compared to known age were significantly different (t(10) = 6.88, p < 0.001) with an average difference of −18.53 years. Dental age estimates of post-burn samples were not significantly different from the known donor age (t(3) = −0.74, p = 0.512) with an average difference of −3.96 years. Overall, the results of this study show that thermally altered remains can be used for histologic age-at-death analysis of cortical bone and dental cementum, within certain burning parameters.
PubMed: 36358272
DOI: 10.3390/biology11111569 -
Journal of Bone and Mineral Metabolism Nov 2022The bone lacunar-canalicular system (LCS) is an important microstructural basis for signaling and material transport in bone tissue, guaranteeing normal physiological...
INTRODUCTION
The bone lacunar-canalicular system (LCS) is an important microstructural basis for signaling and material transport in bone tissue, guaranteeing normal physiological processes in tissues. Spaceflight astronauts and elderly osteoporosis are related to its function, so it is necessary to reveal the mass transfer laws in bone microstructure under different gravity fields to provide insight for effective clinical treatment.
MATERIALS AND METHODS
Using the natural LCS structure of bovine tibial cortical bone as the object, the mass transfer experiments on cortical bone were conducted by using sodium fluorescein tracer through different frequency pulsating pressure provided by dynamic perfusion loading device and different high G environments provided by high-speed centrifuge to analyze the mass transfer laws under different gravity fields and different pulsating pressures.
RESULTS
The fluorescence intensity of lacunae within the osteon was lower the farther away from the Haversian canal. As the gravity field magnitude increased, the fluorescence intensity within each lacuna enhanced, and the more distant the lacunae from the Haversian canal, the greater the fluorescence intensity enhancement. High-frequency pulsating pressure simulated high-intensity exercise in humans can improve mass transfer efficiency in the LCS.
CONCLUSION
High-intensity exercise may greatly increase solute molecules, nutrients, and signaling molecules in osteocytes and improve the activity of osteocytes. Hypergravity can enhance the transport of solute molecules, nutrients, and signaling molecules in the LCS, especially promoting mass transfer to deep layer lacunae. Conversely, mass transfer to deep layer lacunae may be inhibited under microgravity, causing bone loss and ultimately leading to osteoporosis.
Topics: Humans; Animals; Cattle; Aged; Haversian System; Osteocytes; Tibia; Cortical Bone; Osteoporosis
PubMed: 36350408
DOI: 10.1007/s00774-022-01373-z -
Scientific Reports Nov 2022Remodelling is a fundamental biological process involved in the maintenance of bone physiology and function. We know that a range of health and lifestyle factors can...
Remodelling is a fundamental biological process involved in the maintenance of bone physiology and function. We know that a range of health and lifestyle factors can impact this process in living and past societies, but there is a notable gap in bone remodelling data for populations from the Pacific Islands. We conducted the first examination of femoral cortical histology in 69 individuals from ca. 440-150 BP Taumako in Solomon Islands, a remote 'Polynesian Outlier' island in Melanesia. We tested whether bone remodelling indicators differed between age groups, and biological sex validated using ancient DNA. Bone vascular canal and osteon size, vascular porosity, and localised osteon densities, corrected by femoral robusticity indices were examined. Females had statistically significantly higher vascular porosities when compared to males, but osteon densities and ratios of canal-osteon (~ 8%) did not differ between the sexes. Our results indicate that, compared to males, localised femoral bone tissue of the Taumako females did not drastically decline with age, contrary to what is often observed in modern populations. However, our results match findings in other archaeological samples-a testament to past female bone physiology resilience, also now observed in the Pacific region.
Topics: Male; Humans; Female; Haversian System; Femur; Bone and Bones; Bone Remodeling; Melanesia
PubMed: 36344562
DOI: 10.1038/s41598-022-23171-3 -
Journal of the Mechanical Behavior of... Jan 2023Bone encompasses a complex arrangement of materials at different length scales, which endows it with a range of mechanical, chemical, and biological capabilities....
Bone encompasses a complex arrangement of materials at different length scales, which endows it with a range of mechanical, chemical, and biological capabilities. Changes in the microstructure and characteristics of the material, as well as the accumulation of microcracks, affect the bone fracture properties. In this study, two-dimensional finite element models of the microstructure of cortical bone were considered. The eXtended Finite Element Method (XFEM) developed by Abaqus software was used for the analysis of the microcrack propagation in the model as well as for local sensitivity analysis. The stress-strain behavior obtained for the different introduced models was substantially different, confirming the importance of bone tissue microstructure for its failure behavior. Considering the role of interfaces, the results highlighted the effect of cement lines on the crack deflection path and global fracture behavior of the bone microstructure. Furthermore, bone micromorphology and areal fraction of cortical bone tissue components such as osteons, cement lines, and pores affected the bone fracture behavior; specifically, pores altered the crack propagation path since increasing porosity reduced the maximum stress needed to start crack propagation. Therefore, cement line structure, mineralization, and areal fraction are important parameters in bone fracture. The parameter-wise sensitivity analysis demonstrated that areal fraction and strain energy release rate had the greatest and the lowest effect on ultimate strength, respectively. Furthermore, the component-wise sensitivity analysis revealed that for the areal fraction parameter, pores had the greatest effect on ultimate strength, whereas for the other parameters such as elastic modulus and strain energy release rate, cement lines had the most important effect on the ultimate strength. In conclusion, the finding of the current study can help to predict the fracture mechanisms in bone by taking the morphological and material properties of its microstructure into account.
Topics: Humans; Finite Element Analysis; Models, Biological; Cortical Bone; Fractures, Bone; Bone and Bones; Stress, Mechanical
PubMed: 36334581
DOI: 10.1016/j.jmbbm.2022.105530 -
Bioresources and Bioprocessing Nov 2022It is found that the osteon is composed of thin and thick lamellae which are periodic and approximately concentric, every 5 lamellae is a cycle, the periodic helix angle...
It is found that the osteon is composed of thin and thick lamellae which are periodic and approximately concentric, every 5 lamellae is a cycle, the periodic helix angle of mineralized collagen fibers in two adjacent sub-lamellae is 30°. Four bionic composite models with different fiber helix angles were established and fabricated according to the microstructure of mineralized collagen fibers in osteon. Based on the impact analysis of four kinds of bionic composite models, the effects of the fiber periodic spiral structure on the impact resistance and energy dissipation of multi-layer bionic composite were investigated. The analysis results show that the fiber helix angle affects the impact damage resistance and energy dissipation of multi-layer fiber reinforced composites. Among the 4 kinds of multi-layer composite models, the composite model with helix angle of 30° has better comprehensive ability to resist impact damage. The test results show that the impact damage area of the specimen with 30° helix angle is smallest among the 4 types of bionic specimens, which is consistent with the results of finite-element impact analysis. Furthermore, in the case of without impact damage, the smaller the fiber helix angle is, the more uniform the stress distribution is and more energy is dissipated in the impact process. The periodic spiral structure of mineralized collagen fibers in osteon are the result of natural selection of biological evolution. This structure can effectively improve the ability of cortical bone to resist external impact. The research results can provide useful guidance for the design and manufacture of high-performance and strong impact resistant bionic composites.
PubMed: 38647855
DOI: 10.1186/s40643-022-00600-9