-
The International Journal of... Mar 2024This assessment evaluated the clinical feasibility of using narrow-diameter implants to support a mandibular overdenture. Twelve patients presenting with an edentulous...
This assessment evaluated the clinical feasibility of using narrow-diameter implants to support a mandibular overdenture. Twelve patients presenting with an edentulous mandible were recruited from nine dental offices. Each patient received two to four implants in the mandible. The implants were placed without additional bone augmentation, and a total of 36 implants were placed. All sites achieved satisfactory crestal bone stability and soft tissue maintenance 1 year after the final prosthetic restoration. This investigation was supported by the Osseointegration Foundation, working in conjunction with the Zest Anchors implant company. There are three basic valuable activities that emerge from a professional foundation, which were reflected in this case study. They include disseminating information to practitioners, persuading young clinicians to become research investigators, and reaching out to patients in need of treatment who cannot afford it without a charitable opportunity.
Topics: Humans; Dental Implants; Osseointegration; Denture, Overlay; Charities; Prospective Studies; Dental Prosthesis Design; Mandible; Dental Prosthesis, Implant-Supported; Jaw, Edentulous; Follow-Up Studies; Treatment Outcome
PubMed: 37878819
DOI: 10.11607/prd.6622 -
The International Journal of Oral &... Oct 2023Τo evaluate and compare the marginal bone loss (MBL), survival rates, and periodontal parameters of immediately loaded implants with either Dolder bar or Locator... (Randomized Controlled Trial)
Randomized Controlled Trial
Comparative Evaluation of Survival Rates and Marginal Bone Levels of Nonsplinted Immediately Loaded Interforaminal Mandibular Implant-Retained Overdentures: A Randomized Controlled Clinical Trial with 5-Year Results.
PURPOSE
Τo evaluate and compare the marginal bone loss (MBL), survival rates, and periodontal parameters of immediately loaded implants with either Dolder bar or Locator attachments placed in the interforaminal region of edentulous mandibles.
MATERIALS AND METHODS
A total of included 19 patients with edentulous mandibles each received two implants in the interforaminal area of the symphysis. Randomly allocated Dolder bar or Locator attachments were then attached immediately, and both clips and a framework were fastened to the denture by the dental laboratory within 24 hours.
RESULTS
A total of 28 subjects with 56 implants were treated in accordance with the immediate-loading study protocol. Of these, 9 patients were lost to follow-up; 1 patient reported a serious illness and 8 patients moved and couldn't be reached. The 19 subjects not lost to follow-up (11 women and 8 men; average age: 68 years) were included. Every patient received either two Locator abutments and were assigned to group A (7 patients; 36.8%) or two multiunit abutments and were assigned to group B (12 patients; 63.2%). No implant failure was detected for either group, and therefore the survival rate for both groups was 100% after 5 years. After 5 years without any symptoms, 2 implants from group A and 7 implants from group B showed > 2 mm of MBL, which makes the group A success rate 85.7% and the group B success rate 70.8%. Modified sulcular bleeding index (mSBI) did not differ significantly at any of the measurement intervals. However, the modified plaque index (mPI) of group B was significantly higher than group A at the 60-month follow-up.
CONCLUSION
It can be concluded that either splinting or not splinting the immediately loaded interforaminal implants to retain mandibular overdentures (OVDs) does not affect marginal bone levels after 5 years and immediate loading of nonsplinted implants with Locator attachments can be safely preferred to retain mandibular OVDs.
Topics: Male; Humans; Female; Aged; Dental Implants; Survival Rate; Immediate Dental Implant Loading; Denture, Overlay; Jaw, Edentulous; Dental Prosthesis, Implant-Supported; Mandible; Treatment Outcome; Denture Retention; Alveolar Bone Loss
PubMed: 37847837
DOI: 10.11607/jomi.10129 -
Clinical Oral Implants Research Sep 2023To analyze the effect of implant treatment in edentulous patients rehabilitated with implant-supported fixed complete dentures (IFCDs) or implant overdentures (IODs) on... (Meta-Analysis)
Meta-Analysis Review
OBJECTIVES
To analyze the effect of implant treatment in edentulous patients rehabilitated with implant-supported fixed complete dentures (IFCDs) or implant overdentures (IODs) on dental patient-reported outcomes (dPROs).
MATERIALS AND METHODS
In January 2022, Medline, Embase, CINAHL, Cochrane Library, PubMed Central, Web of Science, and ClinicalTrials.gov were screened for prospective clinical studies on completely edentulous patients treated with IFCDs and/or IODs, reporting pre-treatment and follow-up dPROs. Hedges' g effect sizes (ES) with corresponding 95% confidence intervals (CI) were calculated. Afterward, meta-analyses were conducted using random effect models.
RESULTS
A total number of 1608 records was initially identified. Of those, 28 studies reporting dPROs from 1457 patients were finally included. The applied dental patient-reported outcome measures (dPROMs) included several versions of the Oral Health Impact Profile (OHIP) or specific items assessing satisfaction with Visual Analogue Scales (VAS). The overall ES was large for rehabilitation with IFCDs (1.68 [CI: 1.15, 2.20]) and IODs (1.26 [CI: 0.99, 1.52]) with no significant difference (p = .165) between the two. Denture stability was the only factor rated significantly higher for IFCDs (ES difference: 2.37 [CI: 0.21, 4.54]; p = .032). Subgroup analyses revealed moderately higher ES for IODs on two implants relative to one implant (ES difference: 0.73 [CI: 0.34, 1.12]; p < .001).
CONCLUSIONS
There is a strong positive effect of implant treatment in edentulous patients, independent of the type of prosthetic rehabilitation. In patients seeking high stability, IFCDs may be preferable. In mandibular IODs on a single implant, there was a significantly positive effect of an additional implant on dPROs.
Topics: Humans; Denture, Overlay; Prospective Studies; Dental Implants; Denture, Complete; Mouth, Edentulous; Patient Reported Outcome Measures
PubMed: 37750530
DOI: 10.1111/clr.14065 -
Clinical Oral Implants Research Sep 2023The aim of Working Group 4 was to address patient benefits associated with implant dentistry. Focused questions on (a) dental patient-reported outcomes (dPROs), (b)...
OBJECTIVES
The aim of Working Group 4 was to address patient benefits associated with implant dentistry. Focused questions on (a) dental patient-reported outcomes (dPROs), (b) improvement in orofacial function, and (c) preservation of orofacial tissues in partially and fully edentulous patients following provision of implant-retained/supported dental prostheses were addressed.
MATERIALS AND METHODS
Three systematic reviews formed the basis for discussion. Participants developed statements and recommendations determined by group consensus based on the findings of the systematic reviews. These were then presented and accepted following further discussion and modifications as required by the plenary of the 7th ITI Consensus Conference, taking place in 2023 in Lisbon, Portugal.
RESULTS
Edentulous patients wearing complete dentures (CD) experience substantial improvements in overall dPROs and orofacial function following treatment with either complete implant-supported fixed dental prostheses (CIFDP) or implant overdentures (IODs). With respect to dPROs, mandibular IODs retained by two implants are superior to IODs retained by one implant. However, increasing the number of implants beyond two, does not further improve dPROs. In fully edentulous patients, rehabilitation with CIFDP or IOD is recommended to benefit the preservation of alveolar bone and masseter muscle thickness.
CONCLUSIONS
Completely edentulous patients benefit substantially when at least the mandible is restored using an CIFDP or an IOD compared to CD. In fully edentulous patients, implant prostheses are the best option for tooth replacement. The availability of this treatment modality should be actively promoted in all edentulous communities, including those with limited access and means.
Topics: Humans; Dental Implants; Mouth, Edentulous; Denture, Complete; Consensus; Denture, Overlay
PubMed: 37750516
DOI: 10.1111/clr.14145 -
Clinical Oral Implants Research Dec 2023The aim of the current study is to investigate the influence of mechanical stress as well as cleaning agents on the performance of various polyether ether ketone (PEEK)...
OBJECTIVES
The aim of the current study is to investigate the influence of mechanical stress as well as cleaning agents on the performance of various polyether ether ketone (PEEK) inserts for implant-retained overdentures (IOD).
MATERIALS AND METHODS
Three different standard PEEK inserts were subjected to rapid artificial aging through storage in chemical denture cleaning agents (acetic acid, sodium hypochlorite, or sparkling denture cleaner) as well as demineralized water. The pre-aged PEEK inserts were then placed in unilateral IOD and subjected to 200,000 chewing loads (5 kg ~ 50 N), with 5000 thermal cycles (5/55°C), and 1100 removal/insertion cycles (vertical movement 2 mm).
RESULTS
For all the PEEK inserts, the retention forces decreased significantly with an increasing number of mechanical load cycles and after exposure to all the cleaning agents. PEEK inserts aged by exposure to chemical cleaning agents showed a significantly higher decline in retention force than the inserts stored in water. Confocal laser scanning microscopy indicated that the decline in retention force might be caused by wear on the internal insert surface in contact with the patrix.
CONCLUSIONS
Within the limitations of this study, it can be concluded that the application of chemical cleaning agents accelerates the decline in the retention forces of PEEK retentive inserts in IODs.
Topics: Denture Retention; Denture, Overlay; Dental Prosthesis, Implant-Supported; Dental Stress Analysis; Benzophenones; Polyethylene Glycols; Water
PubMed: 37694944
DOI: 10.1111/clr.14180 -
The Journal of Evidence-based Dental... Sep 2023Aim was to assess whether immediate loading (IL) is more effective than delayed loading (DL) for 2-implant bar-retained mandibular overdentures in terms of oral...
OBJECTIVES
Aim was to assess whether immediate loading (IL) is more effective than delayed loading (DL) for 2-implant bar-retained mandibular overdentures in terms of oral health-related quality of life (OHRQoL) improvement over a period of 24-month.
METHODS
In this randomized controlled trial, 32 edentulous patients (mean age: 65.7 ± 10.6 years, 50.0% female) were included. Potential participants had to be unsatisfied with the retention of their current mandibular complete denture and demanded implant treatment for inclusion in the study. OHRQoL was assessed with the 49-item Oral Health Impact Profile (OHIP) at baseline before treatment and 1, 3, 6, 12, and 24 months after implant loading and insertion of implant-retained bars for overdenture support. A mixed-effects model with patients as random effect and an unstructured covariance matrix was developed to address repeated outcome measurement.
RESULTS
Patients' OHRQoL impairment at baseline was substantial indicated by mean OHIP summary score of 45.1 points. OHIP summary scores decreased substantially from baseline to 1-month follow-up to a mean of 33.5 points (P = .020). OHRQoL further improved during study period indicated by OHIP summary score of 25.7 points at 24-month follow-up. Raw treatment effects (IL vs. DL) ranged from -1.2 OHIP points for 12-month follow-up to 5.8 OHIP points for 24-month follow-up. Assuming constant treatment and time effects, treatment effect was small and not statistically significant (-0.7 OHIP points; P= .918).
CONCLUSION
A 2-implant bar-retained mandibular overdentures substantially improves OHRQoL over a period of at least 24 months. There seems to be no significant effect of implant loading protocol.
Topics: Humans; Female; Middle Aged; Aged; Male; Denture, Overlay; Quality of Life; Mandible; Randomized Controlled Trials as Topic
PubMed: 37689447
DOI: 10.1016/j.jebdp.2023.101891 -
Oral and Maxillofacial Surgery Jun 2024Critically evaluate the existing literature and answer the question, "Does the dental implant/mini-implant design influence the stress distribution in prosthetic... (Review)
Review
PURPOSE
Critically evaluate the existing literature and answer the question, "Does the dental implant/mini-implant design influence the stress distribution in prosthetic overdentures according to finite element analysis?".
METHODS
This systematic review was registered in the Open Science Framework (osf.io/2bquj) and followed the PRISMA protocols. The custom search strategy was applied to 4 databases. In vitro experimental studies that evaluated the influence of dental implant/mini-implant design on stress distribution in overdentures by FEM, without time and language restrictions, were included. The selection process was carried out in two stages by two reviewers independently. Risk of bias analysis was performed by a checklist of important parameters.
RESULTS
Sixty articles were evaluated by their title and abstract, four were selected for full reading, three were relevant, and nine were included by additional search. The 12 studies have a low risk of bias. The meta-analysis could not be performed due to the heterogeneity of the data (implant type, design variation, load intensity, and direction).
CONCLUSION
It can be inferred from the evaluated literature that design modifications influence the stress distribution, but as the FEM presents limitations inherent to the in vitro study, clinical trials are necessary to infer the effectiveness of the modifications. It should be noted that there is no consensus on which is the best thread design and that implants with a very narrow diameter are subject to the highest stress concentration.
Topics: Denture, Overlay; Humans; Dental Implants; Finite Element Analysis; Dental Prosthesis, Implant-Supported; Dental Stress Analysis; Dental Prosthesis Design; Stress, Mechanical
PubMed: 37665393
DOI: 10.1007/s10006-023-01177-z -
Journal of Applied Oral Science :... 2023Currently, there is no consensus on the indications and clinical performance of implant-supported overdentures (IODs) involving computer-aided design and manufacturing... (Meta-Analysis)
Meta-Analysis
UNLABELLED
Currently, there is no consensus on the indications and clinical performance of implant-supported overdentures (IODs) involving computer-aided design and manufacturing (CAD-CAM) bars.
OBJECTIVE
To evaluate the performance of IODs involving CAD-CAM bars.
METHODOLOGY
A comprehensive search of studies published until May 2023 was conducted in many databases, including PubMed/MEDLINE, Web of Science, Cochrane Library, and SciELO, following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA). The population, intervention, comparison, outcome (PICO) question was: "How do IODs retained by bars fabricated by CAD-CAM technology perform in daily clinical practice?" The meta-analysis included clinical studies based on effect size and a two-tailed null test with a 95% confidence interval (CI).
RESULTS
Ten studies were included in the meta-analysis. Among them, nine reported a 100% implant survival rate for all CAD-CAM milled bars. Complications were reported in two studies with CAD/CAM-milled titanium bars, and one study reported more fractures in soldered gold bars used in maxillary rehabilitation. However, no fractures were observed in IODs retained by PEEK and zirconia bars. According to six studies, biological complications, including peri-implantitis, were minimal in the BioHPP and PEEK bar groups, while no cases were reported in the titanium or zirconia bar groups. CAD-CAM-milled zirconia bars had higher plaque and bleeding indices compared with titanium bars, as evidenced by findings from five studies. All four studies that evaluated Oral Health Impact Profile (OHIP) scores showed a positive effect of IODs retained by CAD-CAM milled titanium bars on quality of life. Patient satisfaction and acceptance by prosthodontists were significantly high, according to the results of five studies.
CONCLUSION
Overdentures retained with CAD-CAM milled titanium bars show great potential for use in daily clinical practice. Moreover, patient and practitioner satisfaction was very high when this method was used.
Topics: Humans; Denture, Overlay; Quality of Life; Titanium; Computer-Aided Design
PubMed: 37646715
DOI: 10.1590/1678-7757-2023-0054 -
Clinical Implant Dentistry and Related... Dec 2023Hypohidrotic ectodermal dysplasia (HED) patients suffering of oligo-anodontia require early dental treatment to improve oral functions and reduce social impairment. The...
INTRODUCTION
Hypohidrotic ectodermal dysplasia (HED) patients suffering of oligo-anodontia require early dental treatment to improve oral functions and reduce social impairment. The aim of this study was to evaluate the skeletal growth, implant and prosthetic survival rate, success, and complications after the rehabilitation with a maxillary denture and an implant-supported overdenture provided by a sliding bar in case of severe hypodontia/anodontia related to HED.
MATERIALS AND METHODS
This retrospective cohort study began in 2009. Nine patients over 7 years old with HED and associated oligo-anodontia who presented at the University of Bologna for dental treatment were included in the study. They were first treated with conventional dentures and then with a maxillary denture and an implant-supported overdenture with a sliding bar connected to two implants placed in the anterior mandible. The subjects treated were followed for 3-12 years. In each case, orthopanoramic and lateral cephalometric radiographic exam were taken before implant placement and annually after prosthetic load. Vertical and transverse dimensions of the mandible in the symphysis area at implant sites were taken on the lateral cephalometric radiography at the time of implant placement and after 5 years from the prosthetic loading to assess the presence or absence of an anterior mandibular growth. Biologic and mechanical complications were also recorded at every visit.
RESULTS
A mandibular vertical growth under the implant apex, at the implant neck, and a sagittal growth of the symphysis after 5 years from the prosthetic loading were observed and measured. Implant and prosthetic success and survival rates were 100% after 8.1 years (mean) follow-up period. No complications were reported except in one patient, where the repositioning of a retentive cap on the counter bar in the superstructure was necessary after 3 years from the prosthetic loading.
CONCLUSIONS
The present study suggests that the growth of the mandible near implant sites continues even after their positioning. Implants can be successfully placed and provide support for prosthetic rehabilitation in preteens patients with HED.
Topics: Humans; Child; Dental Implants; Cohort Studies; Denture, Overlay; Retrospective Studies; Anodontia; Ectodermal Dysplasia; Mandible; Dental Prosthesis, Implant-Supported; Treatment Outcome; Denture Retention
PubMed: 37608501
DOI: 10.1111/cid.13258 -
Journal of Oral Rehabilitation Dec 2023Adequate muscle activity is important for the success of oral rehabilitation: it maintains the integrity of the stomatognathic system and is responsible for chewing... (Review)
Review
BACKGROUND
Adequate muscle activity is important for the success of oral rehabilitation: it maintains the integrity of the stomatognathic system and is responsible for chewing movements needed to break, crush and grind food.
OBJECTIVE
To compare muscle activity using electromyography (EMG) while clenching or chewing soft and/or hard foods among individuals with natural dentition (ND) and edentulous patients rehabilitated with dental prostheses.
METHODS
This review was conducted until March, 2023, and the research question was "Is the muscle activity of edentulous patients rehabilitated with dental prostheses similar to that of dentate individuals?" A search strategy was conducted in PubMed/MEDLINE, The Cochrane Library, Web of Science, Lilacs, Embase and manual journal searches.
RESULTS
Ten studies were included in the analysis. Most of them reported that individuals with ND had significant higher muscle activity (clenching or chewing) than complete dentures (CD) users. However, no difference was observed between patients with full mouth implant-supported fixed dental prosthesis (ISFDP) and ND. Additionally, two studies compared patients with mandibular ISFDP with maxillary CD and individuals with ND and found no differences; however, one study concluded that patients with ISFDP with CD (maxillary or mandibular) had lower muscle activity than individuals with ND. Only one study reported a higher muscle activity in patients with full-mouth ISFDP than in individuals with ND.
CONCLUSIONS
Bimaxillary CD users had lower muscle activity than individuals with ND. During rehabilitation, the muscle activity of patients with full-mouth ISFDP and mandibular ISFDP with maxillary CD is similar to individuals with ND.
Topics: Humans; Dental Prosthesis, Implant-Supported; Mouth, Edentulous; Denture, Complete; Mastication; Muscles; Dental Implants; Denture, Overlay
PubMed: 37605296
DOI: 10.1111/joor.13564