The Lancet. Global Health Jun 2024Pulse oximeters are essential for assessing blood oxygen levels in emergency departments, operating theatres, and hospital wards. However, although the role of pulse... (Review)
Review
Pulse oximeters are essential for assessing blood oxygen levels in emergency departments, operating theatres, and hospital wards. However, although the role of pulse oximeters in detecting hypoxaemia and guiding oxygen therapy is widely recognised, their role in primary care settings is less clear. In this Viewpoint, we argue that pulse oximeters have a crucial role in risk-stratification in both hospital and primary care or outpatient settings. Our reanalysis of hospital and primary care data from diverse low-income and middle-income settings shows elevated risk of death for children with moderate hypoxaemia (ie, peripheral oxygen saturations [SpO] 90-93%) and severe hypoxaemia (ie, SpO <90%). We suggest that moderate hypoxaemia in the primary care setting should prompt careful clinical re-assessment, consideration of referral, and close follow-up. We provide practical guidance to better support front-line health-care workers to use pulse oximetry, including rethinking traditional binary SpO thresholds and promoting a more nuanced approach to identification and emergency treatment of the severely ill child.
PubMed: 38914087
DOI: 10.1016/S2214-109X(24)00209-2 -
JAMA Network Open Jun 2024Congenital heart disease (CHD) is the most common human organ malformation, affecting approximately 1 of 125 newborns globally.
IMPORTANCE
Congenital heart disease (CHD) is the most common human organ malformation, affecting approximately 1 of 125 newborns globally.
OBJECTIVES
Assessing the performance of 2 diagnostic tests using minimal amounts of dried blood spots (DBS) to identify high-risk CHD compared with controls in a Swedish cohort of neonates.
DESIGN, SETTING, AND PARTICIPANTS
This diagnostic study took place in Sweden between 2019 and 2023 and enrolled full-term babies born between 2005 and 2023. All cases were identified through centralized pediatric cardiothoracic surgical services in Lund and Gothenburg, Sweden. Controls were followed up for 1 year to ensure no late presentations of high-risk CHD occurred. Cases were verified through surgical records and echocardiography.
EXPOSURE
High-risk CHD, defined as cases requiring cardiac surgical management during infancy due to evolving signs of heart failure or types in which the postnatal circulation depends on patency of the arterial duct. Using 3-μL DBS samples, automated quantitative tests for NT-proBNP and interleukin 1 receptor-like 1 (IL-1 RL1; formerly known as soluble ST2) were compared against established CHD screening methods.
MAIN OUTCOMES AND MEASURES
Performance of DBS tests to detect high-risk CHD using receiver operating characteristic curves; Bland-Altman and Pearson correlation analyses to compare IL-1 RL1 DBS with plasma blood levels.
RESULTS
A total of 313 newborns were included (mean [SD] gestational age, 39.4 [1.3] weeks; 181 [57.8%] male). Mean (SD) birthweight was 3495 (483) grams. Analyzed DBS samples included 217 CHD cases and 96 controls. Among the CHD cases, 188 participants (89.3%) were high-risk types, of which 73 (38.8%) were suspected prenatally. Of the 188 high-risk cases, 94 (50.0%) passed pulse oximetry screening and 36 (19.1%) were initially discharged after birth without diagnoses. Combining NT-proBNP and IL-1 RL1 tests performed well in comparison with existing screening methods and enabled additional identification of asymptomatic babies with receiver operating characteristic area under the curve 0.95 (95% CI, 0.93-0.98).
CONCLUSIONS AND RELEVANCE
In this diagnostic study, NT-proBNP and IL-1 RL1 DBS assays identified high-risk CHD in a timely manner, including in asymptomatic newborns, and improved overall screening performance in this cohort from Sweden. Prospective evaluation of this novel approach is warranted.
Topics: Humans; Infant, Newborn; Heart Defects, Congenital; Neonatal Screening; Dried Blood Spot Testing; Biomarkers; Female; Male; Sweden; Natriuretic Peptide, Brain; Peptide Fragments; Case-Control Studies; Interleukin-1 Receptor-Like 1 Protein
PubMed: 38913376
DOI: 10.1001/jamanetworkopen.2024.18097 -
Resuscitation Plus Sep 2024To examine speed and accuracy of newborn heart rate measurement by various assessment methods employed at birth. (Review)
Review
AIM
To examine speed and accuracy of newborn heart rate measurement by various assessment methods employed at birth.
METHODS
A search of Medline, SCOPUS, CINAHL and Cochrane was conducted between January 1, 1946, to until August 16, 2023. (CRD 42021283364) Study selection was based on predetermined criteria. Reviewers independently extracted data, appraised risk of bias and assessed certainty of evidence.
RESULTS
Pulse oximetry is slower and less precise than ECG for heart rate assessment. Both auscultation and palpation are imprecise for heart rate assessment. Other devices such as digital stethoscope, Doppler ultrasound, an ECG device using dry electrodes incorporated in a belt, photoplethysmography and electromyography are studied in small numbers of newborns and data are not available for extremely preterm or bradycardic newborns receiving resuscitation. Digital stethoscope is fast and accurate. Doppler ultrasound and dry electrode ECG in a belt are fast, accurate and precise when compared to conventional ECG with gel adhesive electrodes.
LIMITATIONS
Certainty of evidence was low or very low for most comparisons.
CONCLUSION
If resources permit, ECG should be used for fast and accurate heart rate assessment at birth. Pulse oximetry and auscultation may be reasonable alternatives but have limitations. Digital stethoscope, doppler ultrasound and dry electrode ECG show promise but need further study.
PubMed: 38912532
DOI: 10.1016/j.resplu.2024.100668 -
Annals of Translational Medicine Jun 2024Advancements in medical technologies have led to the development of contact-free methods of haemodynamic monitoring such as remote photoplethysmography (rPPG). rPPG uses...
BACKGROUND
Advancements in medical technologies have led to the development of contact-free methods of haemodynamic monitoring such as remote photoplethysmography (rPPG). rPPG uses video cameras to interpret variations in skin colour related to blood flow, which are analysed to generate vital signs readings. rPPG potentially ameliorates problems like fretfulness and fragile skin contact associated with conventional probes in children. While rPPG has been validated in adults, no prior validation has been performed in children.
METHODS
A two-phased prospective cross-sectional single-centre study was conducted from January to April 2023 to evaluate the feasibility, acceptability, and accuracy of obtaining heart rate (HR), respiratory rate (RR) and oxygen saturation (SpO) using rPPG in children, compared to the current standard of care. In Phase 1, we recruited patients ≤16 years from the neonatal and paediatric wards. We excluded preterm neonates with gestational age <35 weeks and newborns <24 hours old. The rPPG webcam was positioned 30 cm from the face. After 1 minute of facial scanning, readings generated were compared with pulse oximetry for HR and SpO, and manual counting for RR. Correlation and Bland-Altman analyses were performed. In Phase 2, we focused on the population in whom there was potential correlation between rPPG and the actual vital signs.
RESULTS
Ten neonates and 28 children aged 5 to 16 years were recruited for Phase 1 (765 datapoints). All patients were haemodynamically stable and normothermic. Patients and caregivers showed high acceptability to rPPG. rPPG values were clinically discrepant for children <10 years. For those ≥10 years, moderate correlation was observed for HR, with Spearman's correlation coefficient (Rs) of 0.50 [95% confidence intervals (CI): 0.42, 0.57]. We performed Phase 2 on 23 patients aged 12 to 16 years (559 datapoints). Strong correlation was observed for HR with Rs=0.82 (95% CI: 0.78, 0.85). There was weak correlation for SpO and RR (Rs=-0.25 and -0.02, respectively).
CONCLUSIONS
Our study showed that rPPG is acceptable and feasible for neonates and children aged 5 to 16 years, and HR values in older children aged 12 to 16 years correlated well with the current standard. The rPPG algorithms need to be further refined for younger children, and for obtaining RR and SpO in all children. If successful, rPPG will provide a viable contact-free alternative for assessing paediatric vital signs, with potential use in remote monitoring and telemedicine.
PubMed: 38911566
DOI: 10.21037/atm-23-1896 -
BMJ Paediatrics Open Jun 2024Peripheral perfusion index (PPI) is useful in a variety of neonatal settings. Currently, available reference values are from small numbers and highly variable.
BACKGROUND
Peripheral perfusion index (PPI) is useful in a variety of neonatal settings. Currently, available reference values are from small numbers and highly variable.
METHODS
We sought to generate reference values of PPI by analysing previously collected data from newborns who underwent mandated universal pulse oximetry and PPI screening from 2018 to 2021 using uniform protocol and equipment. Q-Q plots and boxplots were used to visualise distributions. Kernel density estimation for heaped and rounded data was used to estimate percentiles of the distributions.
RESULTS
Data from 388 205 newborns who underwent universal pulse oximetry screening in the first week of life were used for this analysis. Pre and postductal values showed a non-normal distribution and skewed to the left, the former had a thicker tail with more extreme values. Minor, but statistically significant differences were seen in the PPI values from day 1 to 7. Median preductal PPI (2.77, IQR:1.83-3.93) was significantly higher than postductal (2.38 IQR: 1.41-3.55) (p<0.01). PPI values increased with weight and boys had higher PPI. Kernel estimates of the percentiles in the overall sample and subgroups for gender and weight have been provided for preductal and post-ductal values.
CONCLUSION
This study, based on the largest available dataset, provides reference values for PPI in newborns. A significant influence of gender and birth weight on PPI values in newborns has been identified. Future research on understanding the influence of age, sex, birth weight, gestational age, ambient temperature and genetic factors on PPI is recommended.
Topics: Humans; Infant, Newborn; Reference Values; Male; Female; Oximetry; Neonatal Screening; Perfusion Index
PubMed: 38906560
DOI: 10.1136/bmjpo-2024-002607 -
Journal of Developmental and Behavioral...DL is an 8-year-old Mexican boy with a posterior atrial septal defect and partial anomalous pulmonary venous return of the right lower pulmonary vein with resultant...
Complex ADHD Challenging Case: Managing Co-Occurring Attention-Deficit Hyperactivity Disorder and Congenital Heart Disease with a Limited Medication Formulary: A Case from Mexico.
DL is an 8-year-old Mexican boy with a posterior atrial septal defect and partial anomalous pulmonary venous return of the right lower pulmonary vein with resultant right heart dilation with normal right ventricular systolic and diastolic function and no arrhythmias. Surgical repair was deferred, and DL's condition was being medically managed with furosemide 0.5 mg/kg BID and spironolactone 0.5 mg/kg BID.DL presents for developmental assessment due to poor performance in school following a lifting of COVID-19 pandemic restrictions and return to in-person classes. He has been attending full-time classes for 3 months without improvements in math, reading, and writing skills. Current attentional concerns at school include an inability to complete tasks without getting distracted by minimal stimuli and highly impulsive behavior.At the first assessment, DL was performing below grade expectations (e.g., reading by syllable without text comprehension, demonstrating preoperational addition and subtraction skills, inability to take dictation)-all of which was viewed as negatively impacted by attentional deficits. DL met DSM-5 criteria for ADHD, predominantly inattentive type. He was started on 10-mg immediate-release methylphenidate PO at 8 am with breakfast and a second dose of 10-mg immediate-release methylphenidate PO 4 hours after the first dose.After a month, at the first follow-up consultation, improvement in attention span, impulsivity, and school performance were observed, including reading skills and math proficiency. However, DL's mother raised concerns about circumoral cyanosis and acrocyanosis in the fingers of both hands after playing outside. These signs were not previously observed. During physical examination at the same visit, heart rate, blood pressure, and oximetry were within baseline ranges and his cardiac examination was unchanged. DL's dosage of methylphenidate was lowered to 10-mg immediate-release methylphenidate PO QD in the mornings with breakfast (8 am).DL did not return to clinic for another 2 months, having discontinued the medication after 2 months of treatment given financial limitations. His mother reported that DL's exertional circumoral cyanosis and acrocyanosis resolved while he was off medication. However, she observed an increase in inattentive symptoms and impulsivity and decline in his academic skills. She asked if our team was able continue the treatment despite the drug side effects, since she believed the benefits outweighed the disadvantages.Given these concerns, the team requested an updated cardiology assessment. The Cardiologist recommended discontinuation of methylphenidate and recommended follow-up with cardiothoracic surgery for reassessment of the surgical timeline.Given the limited treatment options in Mexico, what would you do next as the treating developmental-behavioral clinician…?
Topics: Humans; Male; Attention Deficit Disorder with Hyperactivity; Child; Heart Defects, Congenital; Mexico; COVID-19; Central Nervous System Stimulants; Methylphenidate
PubMed: 38905008
DOI: 10.1097/DBP.0000000000001280 -
Sensors (Basel, Switzerland) May 2024Pulse oximeters are widely used in hospitals and homes for measurement of blood oxygen saturation level (SpO) and heart rate (HR). Concern has been raised regarding a...
Pulse oximeters are widely used in hospitals and homes for measurement of blood oxygen saturation level (SpO) and heart rate (HR). Concern has been raised regarding a possible bias in obtaining pulse oximeter measurements from different fingertips and the potential effect of skin pigmentation (white, brown, and dark). In this study, we obtained 600 SpO measurements from 20 volunteers using three UK NHS-approved commercial pulse oximeters alongside our custom-developed sensor, and used the Munsell colour system (5YR and 7.5YR cards) to classify the participants' skin pigmentation into three distinct categories (white, brown, and dark). The statistical analysis using ANOVA post hoc tests (Bonferroni correction), a Bland-Altman plot, and a correlation test were then carried out to determine if there was clinical significance in measuring the SpO from different fingertips and to highlight if skin pigmentation affects the accuracy of SpO measurement. The results indicate that although the three commercial pulse oximeters had different means and standard deviations, these differences had no clinical significance.
Topics: Humans; Oximetry; Skin Pigmentation; Fingers; Oxygen Saturation; Male; Adult; Female; Oxygen; Heart Rate; Young Adult
PubMed: 38894093
DOI: 10.3390/s24113301 -
Respiratory Care Jun 2024Sleep-disordered breathing (SDB) is frequent in patients with spinal-cord injury (SCI). However, SDB is frequently underdiagnosed due to limited access to diagnostic...
BACKGROUND
Sleep-disordered breathing (SDB) is frequent in patients with spinal-cord injury (SCI). However, SDB is frequently underdiagnosed due to limited access to diagnostic testing and knowledge about the condition. Moreover, SDB heterogeneity (sleep apnea, obstructive sleep apnea or central sleep apnea and nocturnal alveolar hypoventilation) implies complex evaluation of both nocturnal respiratory effort and hypercapnia. The aim of this study was to compare different screening strategies for an SDB diagnosis in patients with SCI.
METHODS
This was a retrospective analysis of data from subjects with SCI followed up in a tertiary-care rehabilitation center with a specialized sleep unit. Subjective (questionnaires) and objective data (polysomnography [PSG]), S extracted from the PSG, morning blood gases, and nocturnal transcutaneous CO (P ) were collected and analyzed. A retrospective comparison of different strategies for SDB screening was carried out. Each strategy was compared (alone and in combination) with the standard of care for sleep apnea (PSG) and nocturnal alveolar hypoventilation (P ) diagnosis. The performance of the usual cutoff and visual analysis was studied.
RESULTS
Among 190 subjects with SCI who underwent a full night's PSG, data were available for 104 questionnaires and 162 with oximetry. Nocturnal alveolar hypoventilation was screened by P and blood gases in 52 subjects with SCI. Questionnaires (the modified Screening for Obstructive Sleep Apnea in Tetraplegia and the Epworth Sleepiness Scale) had poor performance for identifying sleep apnea and did not identify nocturnal alveolar hypoventilation. S (oxygen desaturation index score ≥ 13) and visual analysis of S were good at identifying sleep apnea but insufficient to identify nocturnal alveolar hypoventilation. Diurnal blood gases were poor predictors of nocturnal alveolar hypoventilation.
CONCLUSIONS
Questionnaires were of limited use in subjects with SCI, but the oxygen desaturation index derived from oximetry performed well for sleep apnea screening. Both diurnal blood gases and oximetry visual analysis were insufficient for nocturnal alveolar hypoventilation screening. P monitoring should be mandatory and ideally combined with PSG given the heterogeneity of SDB phenotypes and associated sleep comorbidities of patients with SCI.
PubMed: 38889927
DOI: 10.4187/respcare.11726 -
Khirurgiia 2024To evaluate prognostic significance of tissue oximetry in healing of trophic defects in patients with diabetic foot syndrome (DFS) after endovascular revascularization.
OBJECTIVE
To evaluate prognostic significance of tissue oximetry in healing of trophic defects in patients with diabetic foot syndrome (DFS) after endovascular revascularization.
MATERIAL AND METHODS
In 42 patients with DFS, tissue oximetry was performed in angiosome projection with the FORE-SIGHT MC-2000 (CASMED) device before and the next day after revascularization of lower limb arteries. The 1st group included 30 patients with wound healing throughout 3 months, the 2nd group included 12 patients with amputation or no healing of trophic defects.
RESULTS
Direct revascularization was more common in the 1st group (=0.001). On the day after intervention, oxygen saturation (StO) increased in all angiosomes in both groups (<0.05). StO increment differed significantly between groups in all angiosomes except for point I (<0.05). According to ROC analysis, StO increment by 4.5% in absolute values and 7.9% in percentage leads to trophic defect healing within 3 months (sensitivity and specificity were 76.7% and 66.7% for absolute values, 80% and 58.3% for percentage, respectively).
CONCLUSION
Evaluation of StO in target angiosome may be valuable to predict trophic defect healing after endovascular surgery.
Topics: Humans; Diabetic Foot; Male; Female; Middle Aged; Oximetry; Wound Healing; Aged; Endovascular Procedures; Prognosis; Oxygen Saturation; Treatment Outcome; Spectroscopy, Near-Infrared; Lower Extremity
PubMed: 38888015
DOI: 10.17116/hirurgia202406120 -
European Journal of Anaesthesiology Jun 2024The association between the concentration of atmospheric particulate matter on the day of surgery and the occurrence of intra-operative hypoxaemia in children receiving...
BACKGROUND
The association between the concentration of atmospheric particulate matter on the day of surgery and the occurrence of intra-operative hypoxaemia in children receiving general anaesthesia is unclear.
OBJECTIVE
To investigate the association between the exposure to of particulate matter on the day of surgery and the occurrence of intra-operative hypoxaemia, defined as a pulse oximetry oxygen saturation of less than 90% for more than 1 min, in children.
DESIGN
Retrospective study.
SETTING
Single-centre.
PARTICIPANTS
Children aged 18 years or younger who received general anaesthesia between January 2019 and October 2020.
INTERVENTION
Information on daily levels of particulate matter with a diameter 10 μm or less and 2.5 μm or less measured within a neighbourhood corresponding to the area defined by the hospital's zip code was obtained from publicly available air-quality data.
MAIN OUTCOME MEASURES
The primary outcome was intra-operative hypoxaemia, defined as a pulse oximetry oxygen saturation of less than 90% lasting for more than 1 min, manually verified by anaesthesiologists using vital sign registry data extracted at 2 s intervals.
RESULTS
Of the patients finally analysed, 3.85% (489/13 175) experienced intra-operative hypoxaemia. Higher levels of particulate matter 10 μm or less in diameter (≥81 μg m-3, 472/12 900, 3.7%) were associated with an increased occurrence of intra-operative hypoxaemia compared with lower particulate matter concentrations [<81 μg m-3, 17/275, 6.2%; adjusted odds ratio, 1.71; 95% confidence interval (CI), 1.04 to 2.83; P = 0.035].
CONCLUSION
The level of particulate matter on the day of surgery pose a risk of intra-operative hypoxaemia in children receiving general anaesthesia. If the concentrations of particulate matter 10 μm or less in diameter on the day of surgery are high, children receiving general anaesthesia should be managed with increased caution.
PubMed: 38884417
DOI: 10.1097/EJA.0000000000002027