Journal of Visualized Experiments : JoVE May 2024The detection of levels of impairment in microvascular oxygen consumption and reactive hyperemia is vital in critical care. However, there are no practical means for a...
The detection of levels of impairment in microvascular oxygen consumption and reactive hyperemia is vital in critical care. However, there are no practical means for a robust and quantitative evaluation. This paper describes a protocol to evaluate these impairments using a hybrid near-infrared diffuse optical device. The device contains modules for near-infrared time-resolved and diffuse correlation spectroscopies and pulse-oximetry. These modules allow the non-invasive, continuous, and real-time measurement of the absolute, microvascular blood/tissue oxygen saturation (StO2) and the blood flow index (BFI) along with the peripheral arterial oxygen saturation (SpO2). This device uses an integrated, computer-controlled tourniquet system to execute a standardized protocol with optical data acquisition from the brachioradialis muscle. The standardized vascular occlusion test (VOT) takes care of the variations in the occlusion duration and pressure reported in the literature, while the automation minimizes inter-operator differences. The protocol we describe focuses on a 3-min occlusion period but the details described in this paper can readily be adapted to other durations and cuff pressures, as well as other muscles. The inclusion of an extended baseline and post-occlusion recovery period measurement allows the quantification of the baseline values for all the parameters and the blood/tissue deoxygenation rate that corresponds to the metabolic rate of oxygen consumption. Once the cuff is released, we characterize the tissue reoxygenation rate, magnitude, and duration of the hyperemic response in BFI and StO2. These latter parameters correspond to the quantification of the reactive hyperemia, which provides information about the endothelial function. Furthermore, the above-mentioned measurements of the absolute concentration of oxygenated and deoxygenated hemoglobin, BFI, the derived metabolic rate of oxygen consumption, StO2, and SpO2 provide a yet-to-be-explored rich data set that can exhibit disease severity, personalized therapeutics, and management interventions.
Topics: Spectroscopy, Near-Infrared; Hyperemia; Humans; Critical Care; Oxygen; Oxygen Consumption; Oximetry; Muscle, Skeletal; Microcirculation; Microvessels; Oxygen Saturation
PubMed: 38801263
DOI: 10.3791/66062 -
The Western Journal of Emergency... May 2024Patients with coronavirus 2019 (COVID-19) are at high risk for respiratory dysfunction. The pulse oximetry/fraction of inspired oxygen (SpO/FiO) ratio is a non-invasive...
BACKGROUND
Patients with coronavirus 2019 (COVID-19) are at high risk for respiratory dysfunction. The pulse oximetry/fraction of inspired oxygen (SpO/FiO) ratio is a non-invasive assessment of respiratory dysfunction substituted for the PaO:FiO ratio in Sequential Organ Failure Assessment scoring. We hypothesized that emergency department (ED) SpO/FiO ratios correlate with requirement for mechanical ventilation in COVID-19 patients. Our objective was to identify COVID-19 patients at greatest risk of requiring mechanical ventilation, using SpO/FiO ratios.
METHODS
We performed a retrospective review of patients admitted with COVID-19 at two hospitals. Highest and lowest SpO/FiO ratios (percent saturation/fraction of inspired O) were calculated on admission. We performed chi-square, univariate, and multiple regression analysis to evaluate the relationship of admission SpO/FiO ratios with requirement for mechanical ventilation and intensive care unit (ICU) care.
RESULTS
A total of 539 patients (46% female; 84% White), with a mean age 67.6 ± 18.6 years, met inclusion criteria. Patients who required mechanical ventilation during their hospital stay were statistically younger in age ( = 0.001), had a higher body mass index ( < .001), and there was a higher percentage of patients who were obese ( = 0.03) and morbidly obese ( < .001). Shortness of breath, cough, and fever were the most common presenting symptoms with a median temperature of 99°F. Average white blood count was higher in patients who required ventilation ( = <0.001). A highest obtained ED SpO/FiO ratio of ≤300 was associated with a requirement for mechanical ventilation. A lowest obtained ED SpO/FiO ratio of ≤300 was associated with a requirement for intensive care unit care. There was no statistically significant correlation between ED SpO/FiO ratios >300 and mechanical ventilation or intensive care unit (ICU) requirement.
CONCLUSION
The ED SpO/FiO ratios correlated with mechanical ventilation and ICU requirements during hospitalization for COVID-19. These results support ED SpO/FiO as a possible triage tool and predictor of hospital resource requirements for patients admitted with COVID-19. Further investigation is warranted.
Topics: Humans; COVID-19; Female; Retrospective Studies; Male; Respiration, Artificial; Emergency Service, Hospital; Aged; Oximetry; Intensive Care Units; SARS-CoV-2; Middle Aged; Oxygen Saturation; Oxygen; Aged, 80 and over
PubMed: 38801037
DOI: 10.5811/westjem.17975 -
Chemistry (Weinheim An Der Bergstrasse,... May 2024Cationic Mn(III)-meso-tetraarylporphyrin derivatives, substituted in para position with different size alkyl chains, were investigated to function as antioxidants in...
Cationic Mn(III)-meso-tetraarylporphyrin derivatives, substituted in para position with different size alkyl chains, were investigated to function as antioxidants in free-radical degradation of high-molar-mass hyaluronan by the methods of rotational viscometry and oximetry. The results of rotational viscometry showed that MnTM-4-PyP5+, MnTE-4-PyP5+, MnTPr-4-PyP5+, MnTPen-4-PyP5+ and MnTHep-4-PyP5+ showed high efficiency in decomposing H2O2, and reducing of peroxidized hyaluronan. When using oxygen electrode, MnTE-4-PyP5+, MnTPr-4-PyP5+, MnTPen-4-PyP5+, and MnTHep-4-PyP5+ applied to function as protective antioxidants in hyaluronan degradation, the uptake of dissolved oxygen from the reaction milieu was rapid, followed by continual increase in oxygen concentration up to the end of the measurement. However, when especially MnTE-4-PyP5+, MnTPr-4-PyP5+, and MnTPen-4-PyP5+ were examined as hyaluronan chain-breaking antioxidants, after short-term dissolved oxygen uptake, almost no increase in oxygen concentration was shown.
PubMed: 38797703
DOI: 10.1002/chem.202401028 -
BMC Anesthesiology May 2024Oxygen delivery (DO) and its monitoring are highlighted to aid postoperative goal directed therapy (GDT) to improve perioperative outcomes such as acute kidney injury...
PURPOSE
Oxygen delivery (DO) and its monitoring are highlighted to aid postoperative goal directed therapy (GDT) to improve perioperative outcomes such as acute kidney injury (AKI) after high-risk cardiac surgeries associated with multiple morbidities and mortality. However, DO monitoring is neither routine nor done postoperatively, and current methods are invasive and only produce intermittent DO trends. Hence, we proposed a novel algorithm that simultaneously integrates cardiac output (CO), hemoglobin (Hb) and oxygen saturation (SpO) from the Edwards Life Sciences ClearSight System® and Masimo SET Pulse CO-Oximetry® to produce a continuous, real-time DO trend.
METHODS
Our algorithm was built systematically with 4 components - machine interface to draw data with PuTTY, data extraction with parsing, data synchronization, and real-time DO presentation using a graphic-user interface. Hb readings were validated.
RESULTS
Our algorithm was implemented successfully in 93% (n = 57 out of 61) of our recruited cardiac surgical patients. DO trends and AKI were studied.
CONCLUSION
We demonstrated a novel proof-of-concept and feasibility of continuous, real-time, non-invasive DO monitoring, with each patient serving as their own control. Our study also lays the foundation for future investigations aimed at identifying personalized critical DO thresholds and optimizing DO as an integral part of GDT to enhance outcomes in perioperative cardiac surgery.
Topics: Humans; Cardiac Surgical Procedures; Feasibility Studies; Algorithms; Male; Female; Oxygen; Oximetry; Aged; Middle Aged; Proof of Concept Study; Acute Kidney Injury; Monitoring, Physiologic; Cardiac Output; Hemoglobins; Oxygen Saturation
PubMed: 38796436
DOI: 10.1186/s12871-024-02561-2 -
Vascular May 2024There is a risk of distal embolization lower extremity endovascular interventions. Possibly a drug-coating embolism caused by coating detachment from intravascular... (Review)
Review
INTRODUCTION
There is a risk of distal embolization lower extremity endovascular interventions. Possibly a drug-coating embolism caused by coating detachment from intravascular devices.
METHODS
This review focuses on providing updated information on distal embolism in endovascular revascularization of lower extremity arteries, including the use of drug-coated balloons.
RESULTS
Drug-coating embolism is a special case of distal embolization during recanalization of the arteries of the lower extremities. Preclinical studies have demonstrated embolization of drug-coated balloons during angioplasty of lower extremity arteries. However, the clinical role of drug-coating embolism is not completely clear. A 2020 meta-analysis found an increased risk of major lower extremity amputation after drug-coated balloon angioplasty in patients with critical limb ischemia. But long-term research is emerging to support the safety of using these devices. Perhaps a more thorough assessment of the quality of life and the degree of compensation of lower limb ischemia with an intraoperative assessment of the frequency of peripheral embolizations using ultrasound emboli detection, as well as microcirculation with transcutaneous oximetry and laser Doppler flowmetry of the operated lower limb will allow a more detailed study of the phenomenon of drug-coating embolism and its impact on long-term clinical outcomes.
CONCLUSION
According to the results of preclinical studies, the use of paclitaxel-coated balloons leads to an increase in the concentration of paclitaxel in distal skeletal muscles. However, paclitaxel concentration in skeletal muscle was significantly higher in first-generation DCBs. The non-target effects of drug-coating balloon are not fully understood and require further study. Understanding the phenomenon of drug-coating embolism can help physicians to better assess the patient risk and to minimize complications.
PubMed: 38790137
DOI: 10.1177/17085381241256534 -
Journal of Perinatology : Official... May 2024We prospectively compared cerebral oxygen saturation (CrSO2) and pain score changes during procedures in late preterm (LPT) versus term infants.
OBJECTIVES
We prospectively compared cerebral oxygen saturation (CrSO2) and pain score changes during procedures in late preterm (LPT) versus term infants.
METHODS
Near-infrared spectroscopy, pulse oximetry, Neonatal Infant Pain Scale (NIPS) and Premature Infant Pain Profile-Revised (PIPP-R) scores were assessed and CrSO2 data analyzed.
RESULTS
Thirty infants in each group were evaluated. LPT infants displayed a milder significant drop in Minimum post-procedural CrSO2 and smaller Maximum-Minimum post-procedural CrSO2 disparity. CrSO2 minute changes between the groups were non-significant. Moderate correlations were observed in both groups between NIPS and Minimum post-procedural CrSO2, and a moderate correlation was found in the Maximum-Minimum post-procedural CrSO2 difference in LPT infants. No correlation between PIPP-R and CrSO2 values was noted.
CONCLUSION
LPT and term infants demonstrated decreased CrSO2 in response to painful procedures. Correlations between CrSO2 and PIPP-R or NIPS scores were poor to moderate, reflecting the complex nature of these associations relative to gestational age.
PubMed: 38789794
DOI: 10.1038/s41372-024-01978-4 -
Scientific Data May 2024Pulse oximeters measure peripheral arterial oxygen saturation (SpO) noninvasively, while the gold standard (SaO) involves arterial blood gas measurement. There are known...
Pulse oximeters measure peripheral arterial oxygen saturation (SpO) noninvasively, while the gold standard (SaO) involves arterial blood gas measurement. There are known racial and ethnic disparities in their performance. BOLD is a dataset that aims to underscore the importance of addressing biases in pulse oximetry accuracy, which disproportionately affect darker-skinned patients. The dataset was created by harmonizing three Electronic Health Record databases (MIMIC-III, MIMIC-IV, eICU-CRD) comprising Intensive Care Unit stays of US patients. Paired SpO and SaO measurements were time-aligned and combined with various other sociodemographic and parameters to provide a detailed representation of each patient. BOLD includes 49,099 paired measurements, within a 5-minute window and with oxygen saturation levels between 70-100%. Minority racial and ethnic groups account for ~25% of the data - a proportion seldom achieved in previous studies. The codebase is publicly available. Given the prevalent use of pulse oximeters in the hospital and at home, we hope that BOLD will be leveraged to develop debiasing algorithms that can result in more equitable healthcare solutions.
Topics: Humans; Oximetry; Blood Gas Analysis; Oxygen Saturation; Intensive Care Units; Ethnicity; Oxygen
PubMed: 38789452
DOI: 10.1038/s41597-024-03225-z -
The Annals of Thoracic Surgery May 2024Our objective is to assess the feasibility, safety, and outcomes for patients discharged home with a chest tube connected to a digital drainage system after robotic...
BACKGROUND
Our objective is to assess the feasibility, safety, and outcomes for patients discharged home with a chest tube connected to a digital drainage system after robotic pulmonary resection.
METHODS
This was a retrospective analysis of a prospectively collected database as a quality improvement initiative. All patients had planned discharge on postoperative day one (POD1) after robotic pulmonary resection. Those with an air leak were discharge home with a chest tube connected to a digital drainage system with daily communication with the surgeon.
RESULTS
From January 2019 to February 2023 there were 580 consecutive robotic resections, of which 69 (12%) patients had an air leak on POD1; 38 of 276 (14%) after lobectomy, 24 of 226 (11%) after segmentectomy, and 7 of 78 (9%) after wedge resection. Of these 69 patients, 52 patients (75%) were discharged on POD1, 15 patients (22%) on POD2, and 2 patients (3%) on POD3. Chest tubes were removed a median outpatient chest tube duration was 4 days (interquartile range, 3-5 days). Of the 69 patients sent home with a digital drainage system, there was 1 complication requiring readmission for increasing subcutaneous emphysema. Five patients (7%) had system malfunctions that required return to our clinic for problem-solving. There were no 30- or 90-day mortalities.
CONCLUSIONS
Patients who undergo robotic pulmonary resection and have an air leak can be safely and effectively discharged on the first postoperative day and managed as an outpatient by using daily texts and or videos with pulse oximetry data on a digital drainage system with limited morbidity.
PubMed: 38789008
DOI: 10.1016/j.athoracsur.2024.05.004 -
The Journal of Thoracic and... May 2024There is a lack of knowledge regarding the use of prognostic features in stage I lung adenocarcinoma (LUAD). Thus, we investigated clinicopathologic features associated...
OBJECTIVE
There is a lack of knowledge regarding the use of prognostic features in stage I lung adenocarcinoma (LUAD). Thus, we investigated clinicopathologic features associated with recurrence after complete resection for stage I LUAD.
METHODS
We performed a retrospective analysis of patients with pathologic stage I LUAD who underwent R0 resection from 2010 to 2020. Exclusion criteria included history of lung cancer, induction or adjuvant therapy, noninvasive or mucinous LUAD, and death within 90 days of surgery. Fine and Gray competing-risk regression assessed associations between clinicopathologic features and disease recurrence.
RESULTS
In total, 1912 patients met inclusion criteria. Most patients (1565 [82%]) had stage IA LUAD, and 250 developed recurrence: 141 (56%) distant and 109 (44%) locoregional only. The 5-year cumulative incidence of recurrence was 12% (95% CI, 11%-14%). Higher maximum standardized uptake value of the primary tumor (hazard ratio [HR], 1.04), sublobar resection (HR, 2.04), higher International Association for the Study of Lung Cancer grade (HR, 5.32 [grade 2]; HR, 7.93 [grade 3]), lymphovascular invasion (HR, 1.70), visceral pleural invasion (HR, 1.54), and tumor size (HR, 1.30) were independently associated with a hazard of recurrence. Tumors with 3 to 4 high-risk features had a higher cumulative incidence of recurrence at 5 years than tumors without these features (30% vs 4%; P < .001).
CONCLUSIONS
Recurrence after resection for stage I LUAD remains an issue for select patients. Commonly reported clinicopathologic features can be used to define patients at high risk of recurrence and should be considered when assessing the prognosis of patients with stage I disease.
PubMed: 38788834
DOI: 10.1016/j.jtcvs.2024.05.009 -
Dimensions of Critical Care Nursing :...Continuous pulse oximetry (Spo2) is a commonly utilized tool to obtain an indirect, noninvasive measurement of hemoglobin oxygen saturation. Difficulty obtaining... (Comparative Study)
Comparative Study
BACKGROUND
Continuous pulse oximetry (Spo2) is a commonly utilized tool to obtain an indirect, noninvasive measurement of hemoglobin oxygen saturation. Difficulty obtaining measurement with Spo2 sensors can lead nurses to try off-label sites until they find placement that provides a signal. Currently, there is limited evidence to support this application.
PURPOSE
The purpose of this study was to evaluate the accuracy of off-label placement of pulse oximetry sensors in comparison to on-label placement in adult cardiac intensive care patients.
METHODS
Data were collected on 24 participants. At the time of a medically necessary arterial blood gas laboratory draws, 4 Spo2 measurements were gathered from an on-label finger sensor, an off-label finger sensor, an on-label ear sensor, and an off-label ear sensor. Results were analyzed using 4 Pearson correlation coefficients, Bland-Altman plots, and 2 linear mixed-effect models.
RESULTS
Our study found that while both our on-label finger and off-label finger pulse oximetry sensor overestimated when compared to the arterial hemoglobin saturation (gold standard), there was greater overestimation found with the off-label placement. Though there was not a significant difference observed between the ear probe on the nose and the gold standard, figures examining off-label ear probe and gold standard measures show that, in lower ranges of oxygen saturation, the off-site probe substantially overestimates true oxygen saturation, while in higher ranges of oxygen saturation, the off-site ear probe underestimates true oxygen saturation.
CONCLUSIONS
No changes should be made to the current practice of using pulse oximetry sensor placement.
Topics: Humans; Oximetry; Male; Female; Intensive Care Units; Middle Aged; Adult; Aged; Monitoring, Physiologic
PubMed: 38787772
DOI: 10.1097/DCC.0000000000000647