-
VASA. Zeitschrift Fur Gefasskrankheiten Jun 2024Heavily calcified peripheral artery lesions increase the risk of vascular complications, constituting a severe challenge for the operator during catheter-based...
Heavily calcified peripheral artery lesions increase the risk of vascular complications, constituting a severe challenge for the operator during catheter-based cardiovascular interventions. Intravascular Lithotripsy (IVL) technology disrupts subendothelial calcification by using localized pulsative sonic pressure waves and represents a promising technique for plaque modification in patients with severe calcification in peripheral arteries. Our aim was to systematically review and summarize available data regarding the safety and efficacy of IVL in preparing severely calcified peripheral arteries and its use in Transcatheter Aortic Valve Implantation (TAVI). This study was conducted according to the PRISMA guidelines. We systematically searched PubMed, SCOPUS, and Cochrane databases from their inception to February 23, 2023, for studies assessing the characteristics and outcomes of patients undergoing IVL in the peripheral vasculature. The diameter of the vessel lumen before and after IVL was estimated. The occurrence of peri-procedural complications was assessed using a random-effects model. 20 studies with a total of 1,223 patients with heavily calcified peripheral lesions were analysed. The mean age of the cohort was 70.6 ± 17.4 years. Successful IVL delivery achieved in 100% (95% CI: 100%-100%, I = 0%), with an increase in the luminal diameter (SMD: 4.66, 95% CI: 3.41-5.92, I = 90.8%) and reduction in diameter stenosis (SMD: -4.15, 95% CI: -4.75 to -3.55, I = 92.8%), and a concomitant low rate of complications. The procedure was free from dissection in 97% (95% CI: 91%-100%, I = 81.4%) while dissections of any type (A, B, C, or D) were observed in 6% (95% CI: 2%-10%, I = 85.3%) of the patients. Several rare cases of abrupt closure, no-reflow phenomenon, perforation, thrombus formation, and distal embolization were recorded. Finally, the subgroup analysis of patients who underwent a TAVI with IVL assistance presented successful implantation in 100% (95% CI: 100%-100%, I = 0%) of the cases, with only 4% (95% CI: 0%-12%, I = 68.96%) presenting dissections of any sort. IVL seems to be an effective and safe technique for modifying severely calcified lesions in peripheral arteries and it is a promising modality in TAVI settings. Future prospective studies are needed to validate our results.
PubMed: 38934125
DOI: 10.1024/0301-1526/a001133 -
World Journal of Nuclear Medicine Jun 2024Biliary atresia is one of the most challenging conditions in pediatric surgery even when it is the only finding. Here we present a rare case of biliary atresia...
Biliary atresia is one of the most challenging conditions in pediatric surgery even when it is the only finding. Here we present a rare case of biliary atresia complicated with biliary ascites due to ductal perforation identified on a hepatobiliary iminodiacetic acid (HIDA) scan.
PubMed: 38933070
DOI: 10.1055/s-0043-1764305 -
Clinical Endoscopy Jun 2024Although colonoscopy is a routinely performed procedure, it is not devoid of challenges, such as the potential for perforation and considerable patient discomfort,... (Review)
Review
Although colonoscopy is a routinely performed procedure, it is not devoid of challenges, such as the potential for perforation and considerable patient discomfort, leading to patients postponing the procedure with several healthcare risks. This review delves into preprocedural and procedural solutions, and emerging technologies aimed at addressing the drawbacks of colonoscopies. Insufflation and sedation techniques, together with various other methods, have been explored to increase patient satisfaction, and thereby, the quality of endoscopy. Recent advances in this field include the prevention of loop formation, encompassing the use of variable-stiffness endoscopes, computer-guided scopes, magnetic endoscopic imaging, robotics, and capsule endoscopy. An autonomous endoscope that relies on self-propulsion to completely avoid looping is a potentially groundbreaking technology for the next generation of endoscopes. Nevertheless, critical techniques need to be refined to ensure the development of effective and efficient endoscopes.
PubMed: 38932703
DOI: 10.5946/ce.2024.001 -
Catheterization and Cardiovascular... Jun 2024Intravascular lithotripsy (IVL) combined with rotational atherectomy (RA), known as Rotatripsy, is used to treat severe coronary artery calcification (CAC), though data...
BACKGROUND
Intravascular lithotripsy (IVL) combined with rotational atherectomy (RA), known as Rotatripsy, is used to treat severe coronary artery calcification (CAC), though data on efficacy, midterm safety and use sequence is limited. We aimed to identify indicators for Rotatripsy use and to assess its safety and success rates, both acutely and at 1-year follow-up.
METHODS
Patients undergoing Rotatripsy for severe CAC across six centers from May 2019 to December 2023 were included. Demographic, clinical, procedural and follow-up data were collected. Efficacy endpoints included device success (delivery of the RA-burr and IVL-balloon across the target lesion and administration of therapy without related complications), technical success (TIMI 3 flow and residual stenosis <30% by quantitative coronary analysis) and procedural success [composite of technical success with absence of in-hospital major adverse cardiovascular events (MACE: cardiac death, myocardial infarction or target vessel revascularization). Safety endpoints comprised Rotatripsy-related complications and MACE at 1-year follow-up.
RESULTS
A total of 114 patients (75 ± 9 years, 78% male) underwent Rotatripsy for 120 lesions. In the majority of procedures RA was followed by IVL, mostly electively (n = 68, 57%) but also for balloon underexpansion (n = 37, 31%) and stent crossing failure (n = 1, 1%). Diverse and complex target lesions were addressed with an average SYNTAX score of 24.6 ± 13.0. Device, technical and procedural success were 97%, 94% and 93%, respectively. Therapy-related complications included two (2%) coronary perforations, one (1%) coronary dissection and one (1%) burr entrapment. At 1-year follow-up(present in 77(67%) patients), MACE occurred in 7(9%) cases.
CONCLUSIONS
Over a 1-year follow-up period, Rotatripsy was safe and effective, predominantly using RA electively before IVL.
PubMed: 38932584
DOI: 10.1002/ccd.31140 -
Sensors (Basel, Switzerland) Jun 2024Implantable bioelectronics hold tremendous potential in the field of healthcare, yet the performance of these systems heavily relies on the interfaces between artificial... (Review)
Review
Implantable bioelectronics hold tremendous potential in the field of healthcare, yet the performance of these systems heavily relies on the interfaces between artificial machines and living tissues. In this paper, we discuss the recent developments of tethered interfaces, as well as those of non-tethered interfaces. Among them, systems that study neural activity receive significant attention due to their innovative developments and high relevance in contemporary research, but other functional types of interface systems are also explored to provide a comprehensive overview of the field. We also analyze the key considerations, including perforation site selection, fixing strategies, long-term retention, and wireless communication, highlighting the challenges and opportunities with stable, effective, and biocompatible interfaces. Furthermore, we propose a primitive model of biocompatible electrical and optical interfaces for implantable systems, which simultaneously possesses biocompatibility, stability, and convenience. Finally, we point out the future directions of interfacing strategies.
Topics: Biocompatible Materials; Humans; Prostheses and Implants; Biosensing Techniques; Wireless Technology; Animals
PubMed: 38931581
DOI: 10.3390/s24123799 -
Micromachines Jun 2024Partial-thickness corneal transplants using a deep anterior lamellar keratoplasty (DALK) approach has demonstrated better patient outcomes than a full-thickness cornea...
Partial-thickness corneal transplants using a deep anterior lamellar keratoplasty (DALK) approach has demonstrated better patient outcomes than a full-thickness cornea transplant. However, despite better clinical outcomes from the DALK procedure, adoption of the technique has been limited because the accurate insertion of the needle into the deep stroma remains technically challenging. In this work, we present a novel hands-free eye mountable robot for automatic needle placement in the cornea, AutoDALK, that has the potential to simplify this critical step in the DALK procedure. The system integrates dual light-weight linear piezo motors, an OCT A-scan distance sensor, and a vacuum trephine-inspired design to enable the safe, consistent, and controllable insertion of a needle into the cornea for the pneumodissection of the anterior cornea from the deep posterior cornea and Descemet's membrane. AutoDALK was designed with feedback from expert corneal surgeons and performance was evaluated by finite element analysis simulation, benchtop testing, and ex vivo experiments to demonstrate the feasibility of the system for clinical applications. The mean open-loop positional deviation was 9.39 µm, while the system repeatability and accuracy were 39.48 µm and 43.18 µm, respectively. The maximum combined thrust of the system was found to be 1.72 N, which exceeds the clinical penetration force of the cornea. In a head-to-head ex vivo comparison against an expert surgeon using a freehand approach, AutoDALK achieved more consistent needle depth, which resulted in fewer perforations of Descemet's membrane and significantly deeper pneumodissection of the stromal tissue. The results of this study indicate that robotic needle insertion has the potential to simplify the most challenging task of the DALK procedure, enable more consistent surgical outcomes for patients, and standardize partial-thickness corneal transplants as the gold standard of care if demonstrated to be more safe and more effective than penetrating keratoplasty.
PubMed: 38930758
DOI: 10.3390/mi15060788 -
Journal of Clinical Medicine Jun 2024Sarcoma resection often leaves patients with big defects only amenable through microsurgical reconstruction. In such cases, it is hard for the surgeon to uphold low...
Sarcoma resection often leaves patients with big defects only amenable through microsurgical reconstruction. In such cases, it is hard for the surgeon to uphold low donor-site morbidity with an aesthetic result. The purpose of this study was to investigate the clinical outcome and the patient's perception regarding the donor site in a cohort of patients undergoing microsurgical reconstruction with lateral thigh and lower abdominal perforator flaps. A retrospective evaluation of all patients who underwent sarcoma reconstruction with flaps harvested from the lower abdominal region (deep inferior epigastric artery perforator flap, superficial circumflex iliac artery perforator flap) or lateral thigh region (anterolateral thigh perforator flap and its variations) was performed. Only patients with defects greater than 100 cm were included. Patient demographics and operative variables were recorded, together with complications. Patient satisfaction and quality of life with the donor site were registered using the SCAR-Q questionnaire, which was administered at least six months post-operatively. Eighteen anterolateral thigh (ALT) perforator flaps and twenty-two deep inferior epigastric artery perforator (DIEP) and superficial circumflex iliac artery perforator (SCIP) flap procedures were performed. The two groups were homogeneous for major post-operative complications ( > 0.999). Patient satisfaction with the donor site measured using the SCAR-Q questionnaire showed significantly higher scores in the DIEP/SCIP group when compared with the thigh group ( < 0.001), indicating a superiority of the lower abdominal area as an aesthetic donor site. The DIEP and SCIP flaps are a versatile option for reconstructing large soft-tissue defects following sarcoma resection. Therefore, flaps harvested from the lower abdomen yield a higher patient satisfaction with the donor site, which is a feature worth considering when planning a reconstructive procedure.
PubMed: 38930149
DOI: 10.3390/jcm13123622 -
Journal of Clinical Medicine Jun 2024Photodynamic diagnosis (PDD) during transurethral resection of bladder tumor (TURBT) is guideline recommended, as it improves bladder cancer detection rates. However,...
Photodynamic diagnosis (PDD) during transurethral resection of bladder tumor (TURBT) is guideline recommended, as it improves bladder cancer detection rates. However, the extent to which PDD is implemented in everyday clinical practice has not been thoroughly assessed. We aimed to evaluate the current trends and major perioperative outcomes of TURBT with PDD. The present study evaluated the GeRmAn Nationwide inpatient Data (GRAND) from 2010 (the year when PDD started to be coded separately in Germany) to 2021, which were made available from the Research Data Center of the German Bureau of Statistics. We undertook numerous patient-level and multivariable logistic regression analyses. Overall, 972,208 TURBTs [228,207 (23%) with PDD and 744,001 (77%) with white light] were performed. Patients offered PDD during TURBT were younger ( < 0.001), presented fewer comorbidities ( < 0.001) and were discharged earlier from hospital ( < 0.001). PDD was associated with additional costs of about EUR 500 compared to white-light TURBT ( < 0.001). The yearly TURBT cases remained relatively stable from 2010 to 2021, whereas utilization of PDD underwent a 2-fold increase. After adjusting for major risk factors in the multivariate regression analysis, PDD was related to lower rates of transfusion (1.4% vs. 5.6%, OR: 0.29, 95% CI: 0.28 to 0.31, < 0.001), intensive care unit admission (0.7% vs. 1.4%, OR: 0.56, 95% CI: 0.53 to 0.59, < 0.001) and 30-day in-hospital mortality (0.1% vs. 0.7%, OR: 0.24, 95% CI: 0.22 to 0.27, < 0.001) compared to white-light TURBT. On the contrary, PDD was related to clinically insignificant higher rates of bladder perforation (0.6% versus 0.5%, OR: 1.3, 95% CI: 1.2 to 1.4, < 0.001), and reoperation (2.6% versus 2.3%, OR: 1.2, 95% CI: 1.1 to 1.2, < 0.001). The utilization of PDD with TURBT is steadily increasing. Nevertheless, the road toward the establishment of PDD as the standard of care for TURBT is still long, despite of the advantages of PDD.
PubMed: 38930060
DOI: 10.3390/jcm13123531 -
Journal of Clinical Medicine Jun 2024Ultrasound has revolutionized reconstructive microsurgery, offering real-time imaging and enhanced precision allowing for preoperative flap planning, recipient vessel... (Review)
Review
Ultrasound has revolutionized reconstructive microsurgery, offering real-time imaging and enhanced precision allowing for preoperative flap planning, recipient vessel identification and selection, postoperative flap monitoring, and lymphatic surgery. This narrative review of the literature provides an updated evidence-based overlook on the current applications and emerging frontiers of ultrasound in microsurgery, focusing on free tissue transfer and lymphatic surgery. Color duplex ultrasound (CDU) plays a pivotal role in preoperative flap planning and design, providing real-time imaging that enables detailed perforator mapping, perforator suitability assessment, blood flow velocity measurement, and, ultimately, flap design optimization. Ultrasound also aids in recipient vessel selection by providing assessment of caliber, patency, location, and flow velocity of recipient vessels. Postoperatively, ultrasound enables real-time monitoring of flap perfusion, providing early detection of potential flap compromise and improved flap survival rates. In lymphatic surgery, ultra-high frequency ultrasound (UHFUS) offers precise mapping and evaluation of lymphatic vessels, improving efficacy and efficiency by targeting larger dilated vessels. Integrating ultrasound into reconstructive microsurgery represents a significant advancement in the utilization of imaging in the field. With growing accessibility of devices, improved training, and technological advancements, using ultrasound as a key imaging tool offers substantial potential for the evolution of reconstructive microsurgery.
PubMed: 38929941
DOI: 10.3390/jcm13123412 -
Journal of Personalized Medicine Jun 2024Vulvar stenosis is a debilitating condition that compromises sexual function, urination, and the ability to undergo gynecological examinations. The purpose of this study...
BACKGROUND
Vulvar stenosis is a debilitating condition that compromises sexual function, urination, and the ability to undergo gynecological examinations. The purpose of this study is to describe the technique of capillary perforator perineal flaps (CPPF) for the correction of vulvar stenosis.
METHODS
We retrospectively examined patients with vulvar stenosis treated through surgical separation and reconstruction with CPPF. The procedure involved vulvar separation with the creation of a subsequent defect, repaired using a flap, harvested laterally to the labia majora including a capillary perforator and transferred through a subcutaneous tunnel to repair the vulvar defect. The functional outcome was evaluated with the Bradford scale, comparing the preoperative and postoperative scores using the Student's -test.
RESULTS
thirteen patients were included, three with stenosis following treatment for vulvar cancer and ten due to lichen sclerosus. In total, we analyzed 29 flaps, with an average size of 15.6 cm. We always included just one perforator in the flap and no postoperative complications. Stenosis was resolved in all patients, with no recurrences one year after the surgery. The preoperative average severity of the stenosis was 2.3 + 0.6, reducing to 0.3 + 0.4 post-intervention, indicating a significant improvement ( < 0.01).
CONCLUSIONS
CPPF has proven to be a quick and safe method for the reconstruction of vulvar stenosis.
PubMed: 38929838
DOI: 10.3390/jpm14060617