Journal of Cardiovascular... May 2021Cardiac implantable electronic device (CIED) pocket related problems such as infection, hematoma, and device erosion cause significant morbidity and the clinical...
INTRODUCTION
Cardiac implantable electronic device (CIED) pocket related problems such as infection, hematoma, and device erosion cause significant morbidity and the clinical consequences are substantial. Bioabsorbable materials have been developed to assist in the prevention of these complications but there has not been any direct comparison of these adjunctive devices to reduce these complications. We sought to directly compare the TYRX absorbable antibacterial and CanGaroo extracellular matrix (ECM) envelopes in an animal model susceptible to these specific CIED-related complications (i.e., skin erosion and infection).
METHODS AND RESULTS
Sixteen mice undergoing implantation with biopotential transmitters were divided into three groups (no envelope = 4, TYRX = 5, and CanGaroo = 7) and monitored for device-related complications. Following 12 weeks of implantation, gross and histological analysis of the remaining capsules was performed. Three animals in the CanGaroo group (43%) had device erosion compared to none in the TYRX group. The remaining capsules excised at 12 weeks were qualitatively thicker following CanGaroo compared to TYRX and no envelope and histological evaluation demonstrated increased connective tissue with CanGaroo.
CONCLUSION
CanGaroo ECM envelopes did not reduce the incidence of device erosion and were associated with qualitatively thicker capsules and connective tissue staining at 12 weeks compared to no envelope or TYRX. Further studies regarding the use of these envelopes to prevent device erosion and their subsequent impact on capsule formation are warranted.
Topics: Animals; Anti-Bacterial Agents; Defibrillators, Implantable; Electronics; Mice; Models, Animal; Prosthesis-Related Infections
PubMed: 33010088
DOI: 10.1111/jce.14766 -
Herz Feb 2021The growing problem of endocardial lead infections and lead malfunctions has increased interest in percutaneous lead-removal technology. Transvenous lead extraction...
BACKGROUND
The growing problem of endocardial lead infections and lead malfunctions has increased interest in percutaneous lead-removal technology. Transvenous lead extraction (TLE) via simple manual traction (SMT) is the first-line therapy. When SMT is not successful, TLE from the femoral vein using a gooseneck snare (GS) with a radiofrequency ablation catheter (RFAC) may be an alternative option. The aim of our study was to evaluate the success rate of transvenous extraction of chronically implanted leads via the femoral approach using a GS with RFCA in cases of failure with SMT.
METHODS
The study included 94 consecutive patients who were referred for lead extraction due to pocket erosion and infection (71 patients) and to lead malfunction (23 patients). Initially, SMT was attempted for all patients. If SMT was not successful, patients underwent TLE using a GS with RFAC.
RESULTS
Leads were extracted successfully with SMT in 34 patients (54 leads), while 60 patients (83 leads) underwent TLE using a GS with RFAC. The mean indwelling time of the leads was longer in the femoral approach with GS (87.5 ± 37.9 vs. 31.3 ± 25.8 months; p < 0.001). The procedural success rate was 96.7% in the femoral approach with GS. A preceding implantation lead duration of >51 months predicted an unsuccessful SMT necessitating alternative TLE using a GS with RFAC with 86% sensitivity and 78% specificity (p < 0.001).
CONCLUSION
Transvenous lead extraction via the femoral approach using GS with RFAC may be an alternative approach to SMT with a high success rate, especially when the indwelling time of the leads is long.
Topics: Defibrillators, Implantable; Device Removal; Femoral Artery; Humans; Pacemaker, Artificial; Retrospective Studies; Treatment Outcome
PubMed: 33009623
DOI: 10.1007/s00059-020-04987-z -
Journal of Cardiothoracic Surgery Sep 2020Pocket-related complications following the implantation of cardiovascular implantable electronic devices primarily include pocket hematoma, infection, skin erosion or...
BACKGROUND
Pocket-related complications following the implantation of cardiovascular implantable electronic devices primarily include pocket hematoma, infection, skin erosion or decubitus, device migration, and Twiddler's syndrome, with other pathologies such as nerve impairment or bone lesions being extremely rarely encountered. We report a case of a 20-year old asthenic, non-athlete female patient presenting with a device-generated fracture of the second rib several months after sub-muscular permanent pacemaker implantation due to repeated bilateral pre-pectoral pocket infections.
CASE PRESENTATION
A 20-year old female patient was readmitted to our institution 9 months following sub-pectoral implantation of a permanent pacemaker, complaining of severe pocket-related pain, which arose spontaneously in the absence of direct trauma, intense physical activity or vigorous coughing, and was associated with normal day-to-day activity. To rule out a pacemaker re-infection, a native computed tomography and a positron emission tomography-computed tomography of the thorax were performed. Both modalities excluded an infection but showed a healing fracture and a focus of enhanced metabolic activity in the anterolateral part of the right second rib, indicating a non-traumatic or stress fracture of the bone. Consequently, a complete extraction of the pulse generator and both leads was performed and the smallest available single-chamber pulse generator with a single atrial electrode was implanted in the sub-fascial, pre-muscular pocket in the now recovered and uninfected left subclavicular region, alleviating patient's severe pain symptoms and significantly enhancing her quality of life.
CONCLUSIONS
In the absence of direct trauma, intense physical activity or vigorous coughing, we assume that in this asthenic girl a normal day-to-day motion of the right shoulder has persistently forced the sub-muscularly placed pulse generator toward thoracic wall, putting increased repetitive pressure force on the underlying bones, finally causing a fatigue stress fracture of the second rib. In asthenic phenotype patients with small thorax and short subclavicular distance, a sub-muscular pacemaker implantation can potentially cause unique and unexpected pocket-related adverse events necessitating advanced diagnostics and timely treatment.
Topics: Diagnosis, Differential; Female; Fractures, Stress; Humans; Pacemaker, Artificial; Postoperative Complications; Quality of Life; Rib Fractures; Tomography, X-Ray Computed; Young Adult
PubMed: 32938486
DOI: 10.1186/s13019-020-01303-y -
BMJ Open Aug 2020The 2008 financial crisis had a particularly severe impact on Greece. To contain spending, the government capped public health expenditure and introduced increased...
OBJECTIVES AND SETTING
The 2008 financial crisis had a particularly severe impact on Greece. To contain spending, the government capped public health expenditure and introduced increased cost-sharing. The Greek case is important for studying the impact of recessions on health systems. This study analysed changes in household health expenditure in Greece over the economic crisis and explored whether the impact differed across socioeconomic groups.
PARTICIPANTS
We used data from the Greek Household Budget Survey for the years 2004 and 2008-2017. The dataset comprised 51 654 households, with a total of 128 111 members.
DESIGN
We compared pre-crisis and post-crisis trends in Greek household out-of-pocket payments for healthcare from 2004 to 2017 using an interrupted time series analysis. This study explored spending in euros and as a share of total household purchases.
RESULTS
Our results indicated that the population level trend in household health spending was reversed after the crisis began (pre-crisis trend: €0.040 decrease per quarter (95% CI: -0.785 to -0.022), post-crisis trend: €0.315 increase per quarter (95% CI: -0.004 to 0.635)). We also found that spending on inpatient services and pharmaceuticals has been increasing since the start of the crisis, whereas outpatient services expenditure has been decreasing. Across all households, out-of-pocket payments incurred a greater financial burden after the crisis relative to pre-existing trends, but the poorest households incurred a disproportionately higher burden.
CONCLUSIONS
This was the first study to use an interrupted time series analysis to assess the impact of the economic crisis on household health expenditure in Greece. Our findings suggest that there was an erosion of financial protection for Greek households as a consequence of the economic crisis. This effect was particularly pronounced among poorer households, which is indicative of a regressive financing system.
Topics: Economic Recession; Family Characteristics; Greece; Health Expenditures; Humans; Interrupted Time Series Analysis
PubMed: 32784261
DOI: 10.1136/bmjopen-2020-038158 -
BMC Ophthalmology Jul 2020This report serves to describe the use of a novel adjustable single 8-0 polypropylene suture for scleral fixation without conjunctival dissection, and to describe...
BACKGROUND
This report serves to describe the use of a novel adjustable single 8-0 polypropylene suture for scleral fixation without conjunctival dissection, and to describe related clinical outcomes associated with this approach.
METHODS
In this study, we retrospectively reviewed 28 eyes from 27 patients that underwent scleral fixation of the intraocular lens (IOL) without conjunctival dissection using an adjustable single 8-0 polypropylene suture at the Beijing Tongren Eye Center between April 2018 and April 2019. For this surgical approach, a 23-gauge infusion cannula was set, after which two Hoffmann scleral pockets were created. Next, 8-0 polypropylene sutures were inserted into the eye guided by 10-0 polypropylene sutures of a long straight needle. The 8-0 suture was then used to fix the haptic IOs. Finally, these 8-0 polypropylene sutures were removed from the scleral pockets, and knots were tightened with the adjustable single suture. Primary outcomes included visual acuity and postoperative complication incidence.
RESULTS
For this study, outcomes for 28 eyes from 27 patients (9 female, 18 male) were assessed. Patients had a mean age of 54 ± 15.11 years-old and were followed for an average of 10.18 ± 2.76 months postoperatively. Uncorrected visual acuity in these patients improved significantly from a preoperative value of 1.269 ± 0.464 logMAR to a 3-month postoperative value of 0.409 ± 0.413 logMAR (p = 0.000). The majority of postoperative complications in these patients were temporary and self-limiting, including corneal edema (35.71%), hypotony (14.29%), elevated intraocular pressure (28.58%), and mild hyphema (7.14%). No evidence of exposure or erosion of the trimmed suture end was detected in any patients. An ultrasound biomicroscope was able to readily detect the IOL and all sutures, and IOLs were found to be well-centered without any dislocation, tilting, or subluxation upon follow-up.
CONCLUSIONS
An adjustable single 8-0 polypropylene suture can reliably and effectively be used for scleral fixation without conjunctival dissection for the treatment of patients with aphakia or inadequate posterior capsule support. The novel procedure described herein may therefore be an effective means of minimizing the risk of suture-related complications in patients undergoing scleral-fixated IOL implantation.
TRIAL REGISTRATION
Retrospective case series study, not applicable. NCT04476264 .
Topics: Adult; Aged; Beijing; Dissection; Female; Humans; Lens Implantation, Intraocular; Lenses, Intraocular; Male; Middle Aged; Polypropylenes; Postoperative Complications; Retrospective Studies; Sclera; Suture Techniques; Sutures
PubMed: 32711502
DOI: 10.1186/s12886-020-01558-y -
Genetics, Selection, Evolution : GSE Jul 2020Assessment of genetic diversity and population structure provides important control metrics to avoid genetic erosion, inbreeding depression and crossbreeding between...
BACKGROUND
Assessment of genetic diversity and population structure provides important control metrics to avoid genetic erosion, inbreeding depression and crossbreeding between exotic and locally-adapted cattle breeds since these events can have deleterious consequences and eventually lead to extinction. Historically, the Alpine Arc represents an important pocket of cattle biodiversity with a large number of autochthonous breeds that provide a fundamental source of income for the entire regional economy. By using genotype data from medium-density single nucleotide polymorphism (SNP) arrays, we performed a genome-wide comparative study of 23 cattle populations from the Alpine Arc and three cosmopolitan breeds.
RESULTS
After filtering, we obtained a final genotyping dataset consisting of 30,176 SNPs for 711 individuals. The local breeds showed high or intermediate values of genetic diversity compared to the highly selected cosmopolitan breeds. Patterns of genetic differentiation, multidimensional scaling, admixture analysis and the constructed phylogenetic tree showed convergence, which indicates the presence of gene flow among the breeds according to both geographic origin and historical background. Among the most differentiated breeds, we identified the modern Brown cattle. In spite of admixture events, several local breeds have preserved distinctive characteristics, which is probably due to differences in genetic origin and geographic location.
CONCLUSIONS
This study represents one of the most comprehensive genome-wide analysis of the Alpine cattle breeds to date. Using such a large dataset that includes the majority of the local breeds found in this region, allowed us to expand knowledge on the evaluation and status of Alpine cattle biodiversity. Our results indicate that although many of the analyzed local breeds are listed as endangered, they still harbor a large amount of genetic diversity, even when compared to some cosmopolitan breeds. This finding, together with the reconstruction of the phylogeny and the relationships between these Alpine Arc cattle breeds, provide crucial insights not only into the improvement of genetic stocks but also into the implementation of future conservation strategies.
Topics: Animals; Cattle; Evolution, Molecular; Genotype; Phylogeny; Polymorphism, Single Nucleotide
PubMed: 32664855
DOI: 10.1186/s12711-020-00559-1 -
Retina (Philadelphia, Pa.) Jul 2023We will describe a minimally invasive technique for the repair of iridodialysis, without conjunctival dissections, using intrasceral fixation of a 6-0 polypropylene...
PURPOSE
We will describe a minimally invasive technique for the repair of iridodialysis, without conjunctival dissections, using intrasceral fixation of a 6-0 polypropylene suture with a flanged tip.
METHODS
A flange was created at the end of the suture with thermoplasticity. An ab interno passing of the needle attached to the suture was performed through the peripheral part of the iris and was further passed out from the eye 1.5 mm to 2 mm behind the limbus. Intrascleral fixation of the exterior suture was performed with the aid of the attached needle. After adjusting the tension of the iris relocation, the externalized end of the suture was cut flush to the sclera with scissors. For a wide dialysis, the same manipulations were repeated until the repair was completed.
RESULTS
The technique was used in three eyes of three patients. No visual impairments of monocular diplopia and glare were observed after surgery. Postoperatively, the irises remained well positioned, with no suture erosion, suture loosening, hypotony, scleral atrophy, or chronic inflammation being observed within the follow-up period. Mild postoperative hyphema was observed in one eye of blunt trauma.
CONCLUSION
The present technique provides minimal surgical invasion for the repair of iridodialysis without creations of scleral flap/groove/pocket and conjunctival dissection.
Topics: Humans; Polypropylenes; Iris; Lens Implantation, Intraocular; Sclera; Surgical Flaps; Sutures; Suture Techniques; Lenses, Intraocular
PubMed: 32649489
DOI: 10.1097/IAE.0000000000002904 -
BMC Public Health Jun 2020The dynamic intersection of a pluralistic health system, large informal sector, and poor regulatory environment have provided conditions favourable for 'corruption' in... (Review)
Review
The influence of corruption and governance in the delivery of frontline health care services in the public sector: a scoping review of current and future prospects in low and middle-income countries of south and south-east Asia.
BACKGROUND
The dynamic intersection of a pluralistic health system, large informal sector, and poor regulatory environment have provided conditions favourable for 'corruption' in the LMICs of south and south-east Asia region. 'Corruption' works to undermine the UHC goals of achieving equity, quality, and responsiveness including financial protection, especially while delivering frontline health care services. This scoping review examines current situation regarding health sector corruption at frontlines of service delivery in this region, related policy perspectives, and alternative strategies currently being tested to address this pervasive phenomenon.
METHODS
A scoping review following the Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA) was conducted, using three search engines i.e., PubMed, SCOPUS and Google Scholar. A total of 15 articles and documents on corruption and 18 on governance were selected for analysis. A PRISMA extension for Scoping Reviews (PRISMA-ScR) checklist was filled-in to complete this report. Data were extracted using a pre-designed template and analysed by 'mixed studies review' method.
RESULTS
Common types of corruption like informal payments, bribery and absenteeism identified in the review have largely financial factors as the underlying cause. Poor salary and benefits, poor incentives and motivation, and poor governance have a damaging impact on health outcomes and the quality of health care services. These result in high out-of-pocket expenditure, erosion of trust in the system, and reduced service utilization. Implementing regulations remain constrained not only due to lack of institutional capacity but also political commitment. Lack of good governance encourage frontline health care providers to bend the rules of law and make centrally designed anti-corruption measures largely in-effective. Alternatively, a few bottom-up community-engaged interventions have been tested showing promising results. The challenge is to scale up the successful ones for measurable impact.
CONCLUSIONS
Corruption and lack of good governance in these countries undermine the delivery of quality essential health care services in an equitable manner, make it costly for the poor and disadvantaged, and results in poor health outcomes. Traditional measures to combat corruption have largely been ineffective, necessitating the need for innovative thinking if UHC is to be achieved by 2030.
Topics: Asia; Developing Countries; Fraud; Government; Health Care Sector; Health Personnel; Health Policy; Humans; Income; Medical Assistance; Private Sector; Public Sector; Residence Characteristics
PubMed: 32513131
DOI: 10.1186/s12889-020-08975-0 -
BJU International Oct 2020To compare our extended experience with high submuscular (HSM) reservoir placement to traditional space of Retzius (SOR) placement and to present our current, refined...
OBJECTIVES
To compare our extended experience with high submuscular (HSM) reservoir placement to traditional space of Retzius (SOR) placement and to present our current, refined 'Five-Step' technique (FST) for HSM placement.
PATIENTS AND METHODS
Data were retrospectively collected on patients undergoing inflatable penile prosthesis (IPP) placement between January 2009 and June 2019. Re-operative cases were excluded. Reservoir-related complications and subsequent revisions were compared between SOR (2009-2012) and HSM reservoir groups (2012-2019). HSM patients were subdivided into two cohorts: 'Initial Technique' (2012-2014) and FST (2014-2019). The refined FST protocol was developed in 2014 to optimise outcomes and includes the following steps: (i) Position and Access; (ii) Develop Lower HSM Pocket; (iii) Develop Upper HSM Pocket; (iv) Reservoir Delivery (fill and fine-tune); (v) Confirm and Connect.
RESULTS
Between January 2009 and June 2019, 733 total IPP procedures (586 HSM, 147 SOR) were performed by a single surgeon at our institution, 561 of which were virgin cases (430 HSM, 131 SOR) and included in this analysis. Overall, surgical revision was required in 10/430 (2.3%) HSM cases (one delayed bowel obstruction, nine herniations) and six of 131 (4.6%) SOR cases (one bladder erosion, two vascular injuries, and three herniations, P = 0.22). When comparing the FST to the Initial Technique, we noted a significant decrease in complications requiring surgical revision (P = 0.01). Among 133 cases performed with the Initial Technique, seven (5.3%) required surgical revision (one bowel obstruction after placement into the peritoneal cavity, six herniations). Among 297 FST cases, three (1.0%) required revision, all due to herniation.
CONCLUSION
HSM placement of IPP reservoirs is a safe alternative to traditional SOR placement. Major deep pelvic reservoir complications were minimised using our current refined FST.
Topics: Adult; Aged; Aged, 80 and over; Erectile Dysfunction; Humans; Male; Middle Aged; Penile Implantation; Penile Prosthesis; Postoperative Complications; Prosthesis Design; Reoperation; Retrospective Studies; Young Adult
PubMed: 32400957
DOI: 10.1111/bju.15106 -
Indian Pacing and Electrophysiology... 2020Insertable cardiac monitors (ICMs) are often used for long-term monitoring of cardiac rhythm. The Medtronic's LINQ Reveal ™ is a new generation wireless, automated,...
BACKGROUND
Insertable cardiac monitors (ICMs) are often used for long-term monitoring of cardiac rhythm. The Medtronic's LINQ Reveal ™ is a new generation wireless, automated, and patient responsive subcutaneous ECG monitoring device. Despite several advantages to its small size we have noted an unusually high incidence of extrusion at our center.
METHODS
& Results: We conducted a retrospective case analysis to review Reveal LINQs implanted at our center. All devices were inserted using the provided insertion tools. Patients with extruded devices were identified and details regarding the site and technique of insertion, incision closure, use of peri-operative antibiotics, and follow-up details were collected. 81 patients underwent 85 Reveal LINQ implants at a tertiary care University Hospital referral center. The most common reason for implant was suspected arrhythmia with or without structural heart disease or unexplained syncope. There were 4 spontaneous extrusions occurring within 7-24 days after insertion with an incidence rate of 4.7%. One extruded device was anchored to subcutaneous tissue, and no pocket/device infections or hematomas were noted.
CONCLUSIONS
Device migration and erosion through skin are important potential adverse events for the Reveal LINQ implantable loop recorder. This study reports an unexpectedly high rate of extrusion without infection. The authors suggest that the depth of the incision is the main factor impacting extrusions. Larger studies are recommended, however, and a proposed measure to avoid spontaneous extrusion is the design of a longer manufacturer's blade in order to increase the depth of the incision and insertion.
PubMed: 32298763
DOI: 10.1016/j.ipej.2020.04.005