-
Neurologia I Neurochirurgia Polska Jun 2024Ventriculoatrial shunts are the alternative treatments when it is impossible to use ventriculoperitoneal shunts. Limited indication for ventriculoatrial shunt is due to...
Ventriculoatrial shunts are the alternative treatments when it is impossible to use ventriculoperitoneal shunts. Limited indication for ventriculoatrial shunt is due to the possibility of very serious complications inherent with this procedure. We present a case report of a young patient who suffered from disconnection of an atrial catheter from the valve after an accidental blow to his neck. The atrial catheter was dislocated to the heart and pulmonary artery and it was extracted through the femoral vein in the groin area using an endovascular technique. The procedure went without complications. A new atrial catheter was introduced under ultrasonic guidance during surgical revision.
PubMed: 38864765
DOI: 10.5603/pjnns.99224 -
World Journal For Pediatric &... Jun 2024We present a case of a rare example of a ventriculo-arterial septal defect found in a patient with a common arterial trunk, with balanced aortic and pulmonary...
We present a case of a rare example of a ventriculo-arterial septal defect found in a patient with a common arterial trunk, with balanced aortic and pulmonary components, but with separate valvar orifices within the common truncal valve. We managed the lesion using a two-patch approach. Performing a palliative procedure to relieve the elevated right ventricular pressure aided in the preservation of the pulmonary component of the common valve. We validated the success of the technique using postoperative computerized tomography and four-dimensional flow magnetic resonance imaging.
PubMed: 38860291
DOI: 10.1177/21501351241249491 -
Cardiovascular Ultrasound Jun 2024To evaluate the feasibility of a transthoracic echocardiogram using an apical-subcostal protocol in invasive mechanical ventilation (IMV) and prone position.
AIMS
To evaluate the feasibility of a transthoracic echocardiogram using an apical-subcostal protocol in invasive mechanical ventilation (IMV) and prone position.
METHODS
Prospective study of adults who required a prone position during IMV. A pillow was placed only under the left hemithorax in the prone position to elevate and ease the apical and subcostal windows. A critical care cardiologist (prone group) acquired and evaluated the images using the apical-subcostal protocol. Besides, we used ambulatory echocardiograms performed as a comparative group (supine group).
RESULTS
86 patients were included, 43 in the prone and 43 in the supine. In the prone group, the indication to perform an echocardiogram was hemodynamic monitoring. All patients were ventilated with protective parameters, and the mean end-expiratory pressure was 10.6 cmH2O. The protocol was performed entirely in 42 of 43 patients in the prone group because one patient did not have any acoustic window. In the 43 patients in the prone group analyzed and compared to the supine group, global biventricular function was assessed in 97.7% (p = 1.0), severe heart valve disease in 88.4% (p = 0.055), ruled out of the presence of pulmonary hypertension in 76.7% (p = 0.80), pericardial effusion in 93% (p = 0.12), and volume status by inferior vena cava in 93% (p = 0.48). Comparing prone versus supine position, a statistical difference was found when evaluating the left ventricle apical 2-chamber view (65.1 versus 100%, p < 0.01) and its segmental function (53.4 versus 100%, p < 0.01).
CONCLUSION
The echocardiogram using an apical-subcostal protocol is feasible in patients in the IMV and prone position.
Topics: Humans; Male; Prone Position; Female; Prospective Studies; Respiration, Artificial; Echocardiography; Feasibility Studies; Middle Aged; Intensive Care Units; Patient Positioning; Aged
PubMed: 38858752
DOI: 10.1186/s12947-024-00326-y -
International Journal of Cardiology.... Aug 2024To investigate the change in severity of mitral regurgitation (MR) after transcatheter aortic valve replacement (TAVR) and its effect on 5-year mortality.
OBJECTIVES
To investigate the change in severity of mitral regurgitation (MR) after transcatheter aortic valve replacement (TAVR) and its effect on 5-year mortality.
BACKGROUND
There is inconsistency in literature on pre-existing MR influencing long-term survival in patients who undergo TAVR.
METHODS
Patients who underwent TAVR at the University Hospital Schleswig-Holstein (USKH) Campus Kiel between March 2009 and February 2018 have been enrolled. Echocardiography determined the degree of MR before and within 7 days after TAVR. Patients were divided into two groups according to their MR at baseline: MR-grade ≤ 2 (non-relevant MR, nr-MR) and baseline MR-grade > 2 (relevant MR, r-MR). Primary endpoint was a composite of MR baseline influence on mortality and MR reduction and its' impact on mortality.
RESULTS
A total of 820 patients (642 nr-MR and 178 in r-MR) were included in this study. Of these, 167 patients showed an improvement in MR-grade. Thereof 106 (63.5 %) referred to r-MR with a significant decrease in mean MR-grade (p < 0.01). Systolic pulmonary artery pressure (sPAP) (p < 0.01) and NT-proBNP (p = 0.03) decreased in patients who had an improvement. There was no significant difference in 5-year mortality for MR at baseline (p = 0.35) or reduction in mortality for r-MR patients with an MR improvement compared to patients with worsening or equal MR status (p = 0.80).
CONCLUSION
In patients undergoing TAVR, 63.5 % of patients with MR-grade ≥ 2 at baseline showed an improvement of grade of MR after TAVR with reduction of their sPAP and NT-proBNP values but there was no significant difference in mortality.
PubMed: 38854408
DOI: 10.1016/j.ijcha.2024.101416 -
Pediatric Cardiology Jun 2024Atrial function provides insight into ventricular diastolic function. Invasive assessment of left ventricular (LV) diastolic function correlates with development of...
Atrial function provides insight into ventricular diastolic function. Invasive assessment of left ventricular (LV) diastolic function correlates with development of sustained ventricular tachyarrhythmias in patients with repaired tetralogy of Fallot (rTOF). Non-invasive assessment of atrial function may prove key towards assessment of diastolic function. We longitudinally evaluated the progression of biatrial function in patients with rTOF, regardless of pulmonary valve replacement (PVR). Patients with rTOF who had multiple CMR were identified. CMR examinations were retrospectively reviewed. Left (LA) and right (RA) atrial size and function were measured in the two and four-chamber views and assessed over time and after PVR. Left and right atrial reservoir, conduit, pump strain and strain rates were determined using tissue tracking. Thirty-six patients with rTOF were identified (64% male), ten (28%) had PVR during the study. Median age of PVR was 16.5 years. No improvement in RA or LA function was observed after PVR. A decline in RA reservoir strain rate (p < 0.05) and RA pump strain (p < 0.05) were observed despite improvements in right ventricular systolic function (p < 0.05). In patients who had multiple CMR without PVR, RA reservoir strain rate (p < 0.05) and pump strain rate (p < 0.05) worsened over time. LA pump strain decreased over time in all patients. There is progressive decline of several RA functional parameters over time. No significant improvement in LA or RA function after PVR was observed. Additional studies are needed to understand how these changes may relate to poor outcomes and potentially better guide timing of PVR.
PubMed: 38849600
DOI: 10.1007/s00246-024-03503-y -
European Journal of Case Reports in... 2024Alagille syndrome (ALGS) is a multisystem disorder involving at least three systems among the liver, heart, skeleton, face, and eyes. Common cardiac associations include...
BACKGROUND
Alagille syndrome (ALGS) is a multisystem disorder involving at least three systems among the liver, heart, skeleton, face, and eyes. Common cardiac associations include pulmonary artery stenosis/atresia, atrial septal defect (ASD), ventricular septal defect (VSD) and tetralogy of fallot (ToF). Coarctation of aorta (CoA), renal and intracranial arteries are commonly involved vessels in Alagille syndrome. We present two cases with rare cardiovascular manifestations of Alagille syndrome. .
CASE 1
A 25-year-old female with a history of Alagille syndrome presented to the cardiologist office for progressive exertional dyspnoea, orthopnoea, and palpitations. She was tachycardiac on examination and had an apical diastolic rumble. A transthoracic echocardiogram (TTE) showed a left ventricular ejection fraction (LVEF) of 60% and parachute mitral valve (PMV) with severe mitral stenosis. A transoesophageal echocardiogram (TOE) showed insertion of chordae into the anterolateral papillary muscle, severe mitral stenosis with a valve area of 0.7 cm. She was referred to a congenital heart disease specialist and underwent robotic mitral valve replacement with improvement in her symptoms.
CASE 2
A 27-year-old female with known Alagille syndrome and resistant hypertension presented to the cardiologist office due to progressive exertional dyspnoea for a year. She was hypertensive and had a new 2/6 systolic ejection murmur along the left upper sternal border. TTE revealed an LVEF of 60% and pulmonary artery pressure of 19 mmHg. A CoA was suspected distal to the left subclavian artery due to a peak gradient of 38 mmHg. Cardiac magnetic resonance (CMR) imaging ruled out CoA, and diffuse narrowing of the descending thoracic aorta measuring 13-14 mm in diameter was noted. The patient was referred to a congenital heart disease specialist for further management.
CONCLUSION
PMV presenting as mitral stenosis and mid-aortic syndrome are not commonly described anomalies in association with Alagille syndrome. TTE, TOE and CMR played a key role in diagnosis and management of these patients.
LEARNING POINTS
Alagille syndrome (ALGS) is a complex multisystem disorder involving the liver, heart, skeleton, face, and eyes. Cardiovascular involvement occurs in up to 95% of the patients.Common cardiac associations include pulmonary artery stenosis/atresia, atrial septal defect (ASD), ventricular septal defect (VSD) and tetralogy of fallot (ToF).A parachute mitral valve (PMV) presenting as mitral stenosis and mid-aortic syndrome is not commonly described anomalies in association with ALGS. Here, we present such rare cases.
PubMed: 38846669
DOI: 10.12890/2024_004545 -
European Journal of Case Reports in... 2024Atypical myxoma has been reported in various locations in the heart, however, myxoma involving the pulmonary valve is rare. Here we present a case of pulmonic valve...
BACKGROUND
Atypical myxoma has been reported in various locations in the heart, however, myxoma involving the pulmonary valve is rare. Here we present a case of pulmonic valve myxoma which was resected via a percutaneous approach.
CASE REPORT
A 66-year-old female with known metastatic adenocarcinoma of the lung, and chronic obstructive pulmonary disease presented with acute onset shortness of breath for two days. The patient experienced respiratory arrest en-route to the hospital and required intubation. Computed tomography angiography (CTA) of the chest revealed a new 1.4 × 1.6 cm intracardiac mass along the pulmonary valve. Further evaluation with cardiac magnetic resonance imaging revealed it to be a large vascular tumor on the ventricular side of the pulmonary valve, attached with a narrow stalk. Due to high surgical risk, the patient underwent transesophageal echocardiographic guided percutaneous removal of the mass. Pathology confirmed the mass to be a myxoma.
CONCLUSION
Atypical myxoma should be considered in the differential diagnosis of valvular masses. Percutaneous resection of valvular masses may be feasible in high-risk surgical patients.
LEARNING POINTS
Pulmonary valve myxoma is a rare condition and the literature on the characteristics and treatment options for pulmonary valve myxoma is limited.Our patient was treated with a minimally invasive treatment approach: removal of a tumor with intra operative transesophageal echocardiographic guidance using AngioVac and Flow Triever catheters.Percutaneous resection of valvular masses may be feasible in high surgical risk patients.
PubMed: 38846647
DOI: 10.12890/2024_004519 -
European Heart Journal. Case Reports Jun 2024Iatrogenic aortic valve injury during cardiovascular catheterization interventions is extremely rare. Severe aortic regurgitation that ensues can be catastrophic and the...
BACKGROUND
Iatrogenic aortic valve injury during cardiovascular catheterization interventions is extremely rare. Severe aortic regurgitation that ensues can be catastrophic and the management is typically with surgical valve replacement or repair. Percutaneous management of native pure aortic regurgitation is difficult due to anatomical challenges and the limitations of current transcatheter heart valve technology to anchor in the absence of leaflet or annular calcification.
CASE SUMMARY
An 82-year-old female underwent rotational atherectomy (RA) for a severely calcified stenosis of the left anterior descending artery. The patient was discharged well following placement of two drug eluting stents. She represented to hospital 7 days later with acute pulmonary oedema. Bedside transthoracic echocardiography demonstrated new, severe AR with preserved left ventricular size and function. Review of the prior percutaneous coronary intervention revealed significant trauma to the aortic valve during RA, with contrast seen refluxing into the LV during diastole, evolving throughout the procedure. Given the patient was not an operative candidate, an oversized transcatheter aortic valve was successfully implanted. In the post-operative setting, the patient suffered a stroke. Extensive hypoattenuated leaflet thickening (HALT) and thrombus was seen on dedicated 4D CT imaging. She made full neurological recovery and valve function returned to normal following a period of anticoagulation.
CONCLUSION
Although iatrogenic aortic valve laceration is rare, this case highlights several important learning points including the importance of good guide catheter support during RA; the feasibility of Transcatheter Aortic Valve Replacement for pure native AR; and the detection and management of HALT.
PubMed: 38845809
DOI: 10.1093/ehjcr/ytae226 -
The American Journal of Cardiology Jun 2024New-generation transcatheter heart valves have significantly improved technical success and procedural safety of transcatheter aortic valve implantation (TAVI)...
New-generation transcatheter heart valves have significantly improved technical success and procedural safety of transcatheter aortic valve implantation (TAVI) procedures; however, the incidence of permanent pacemaker implantation (PPI) remains a concern. This study aimed to assess the role of anatomic annulus features in determining periprocedural conduction disturbances leading to new PPI after TAVI using the last-generation Edwards SAPIEN balloon-expandable valves. In the context of a prospective single-center registry, we integrated the clinical and procedural predictors of PPI with anatomic data derived from multislice computed tomography. A total of 210 consecutive patients treated with balloon-expandable Edwards transcatheter heart valve were included in the study from 2015 to 2023. Technical success was achieved in 197 procedures (93.8%), and 26 patients (12.4%) required new PPI at the 30-day follow-up (median time to implantation 3 days). At the univariable logistic regression analysis, preprocedural right bundle branch block (odds ratio [OR] 2.24, 95% confidence interval [CI] 1.01 to 4.97, p = 0.047), annulus eccentricity ≥0.25 (OR 5.43, 95% CI 2.21 to 13.36, p <0.001), calcium volume at annulus of the right coronary cusp >48 mm (OR 2.60, 95% CI 1.13 to 5.96, p = 0.024), and prosthesis implantation depth greater than membranous septum length (OR 2.17, 95% CI 1.10 to 4.28, p = 0.026) were associated with new PPI risk. In the multivariable analysis, preprocedural right bundle branch block (OR 2.81, 95% CI 1.01 to 7.85, p = 0.049), annulus eccentricity ≥0.25 (OR 4.14, 95% CI 1.85 to 9.27, p <0.001), and annulus calcium >48 mm (OR 2.89, 95% CI 1.07 to 7.82, p = 0.037) were confirmed as independent predictors of new PPI. In conclusion, specific anatomic features of the aortic valve annulus might have an additive role in determining the occurrence of conduction disturbances in patients who underwent TAVI with balloon-expandable valves. This suggests the possibility to use multislice computed tomography to improve the prediction of post-TAVI new PPI risk.
PubMed: 38844197
DOI: 10.1016/j.amjcard.2024.05.034