-
Scientific Reports Jun 2024In electroretinographic (ERG) recordings of zebrafish, the light stimulus is usually delivered by a fiber optic cable. The purpose of this study was to determine whether...
In electroretinographic (ERG) recordings of zebrafish, the light stimulus is usually delivered by a fiber optic cable. The purpose of this study was to determine whether the angle of incidence of the stimulus light from the fiber optic cable will affect the amplitudes and implicit times of the ERGs of zebrafish larvae. The larvae were positioned on their side with the right eye pointed upward. The light stimuli were delivered by a fiber optic cable from three directions of the larvae: frontal 0° (F0°), dorsal 30°(D30°), and ventral 30°(V30°). Photopic ERGs were recorded from 16 larvae at age 5-6 days post-fertilization. Our results showed that the mean amplitude of the b-wave elicited at D30° and V30° stimulation was significantly smaller than that elicited at F0° stimulation (P = 0.014 and P = 0.019, respectively). In addition, the mean amplitude of the d-wave elicited at D30° and V30° stimulation was significantly smaller than that elicited at F0° stimulation (P < 0.0001 and P = 0.015, respectively). However, the difference between the b-wave amplitudes elicited at D30° and V30° stimuli were not significant (P = 0.98), and the d-wave amplitudes were also not significantly different (P = 0.20). The average b-wave amplitudes elicited at D30° stimulation was 84.6 ± 15.7% and V30° stimulation was 84.8 ± 17.4% relative to that of F0° stimulation. The average d-wave amplitudes elicited by D30° stimulation was 85.5 ± 15.2% and by V30° stimulation was 79.0 ± 11.0% relative to that of F0° stimulation. The differences in the implicit times of the b- and d-wave elicited by the different directions of stimulation were not significant (P = 0.52 and P = 0.14, respectively). We conclude that the amplitude of the photopic ERGs is affected by the angle of the incident light. Thus, it would be better to use ganzfeld stimuli to elicit maximum b- and d-wave amplitudes of the photopic ERGs of zebrafish larvae.
Topics: Animals; Zebrafish; Electroretinography; Larva; Photic Stimulation; Light; Retina
PubMed: 38926421
DOI: 10.1038/s41598-024-65017-0 -
International Ophthalmology Jun 2024The aim of this study was to evaluate the lamina cribrosa curvature index in different types of glaucoma in comparison with clinical findings and conventional...
OBJECTIVE
The aim of this study was to evaluate the lamina cribrosa curvature index in different types of glaucoma in comparison with clinical findings and conventional measurement methods.
MATERIAL AND METHOD
Patients older than 18 years who were followed up in Glaucoma Unit of Department of Ophthalmology at Fırat University Faculty of Medicine, whose disease had been under control at least for 1 year, who had at least three reliable visual fields, whose refractive error was between - 6 and + 5 diopter and who did not have any disease other than glaucoma that would affect the visual field, were included in the study. Clinical and demographic characteristics, visual field, optical coherence tomography and lamina cribrosa curvature index (LCCI) results were evaluated. The study patients were divided into six groups: early-stage primary open-angle glaucoma (POAG) as group 1 and intermediate-advanced stage POAG as group 2, pseudo-exfoliation glaucoma (PEXG) as group 3, normal tension glaucoma (NTG) as group 4, ocular hypertension patients whom subsequently developed POAG as group 5 and healthy control as group 6.
RESULTS
A total of 189 eyes of 101 patients were included in our study. Forty-seven patients were male (46.5%) and 54 were female (53.5%). The mean age was 62.43 ± 1.49 years. LCCI, mean deviation (MD), visual field index (VFI), pattern standard deviation (PSD) and retinal nerve fiber layer thickness (RNFL) values were analyzed in all groups and Pearson correlation analysis showed statistically significant correlation between PSD and RNFL measurements with LCCI values in all groups. MD value was correlated with LCCI in groups 2, 3 and 4, while VFI value was correlated with LCCI in all groups except group 5. When the groups were compared with each other according to the Post-Hoc Tamhane test, LCCI measurement showed statistically significant results in accordance with MD, VFI, PSD and RNFL values.
CONCLUSION
The LCCI assessment is mostly consistent with conventional tests. In this study, in which different types of glaucoma and healthy subjects were examined simultaneously, LCCI shows promise as a detailed and reliable assessment method.
Topics: Humans; Male; Female; Tomography, Optical Coherence; Middle Aged; Visual Fields; Optic Disk; Intraocular Pressure; Aged; Glaucoma, Open-Angle; Retinal Ganglion Cells; Nerve Fibers; Adult; Follow-Up Studies; Glaucoma
PubMed: 38926206
DOI: 10.1007/s10792-024-03190-x -
Ceska a Slovenska Oftalmologie :... 2024To summarize the history and current trends in the use of scleral grafts in ophthalmology. (Review)
Review
AIM
To summarize the history and current trends in the use of scleral grafts in ophthalmology.
MATERIALS AND METHODS
We conducted a review of the literature through the MEDLINE and Cochrane Library databases. The search terms were "sclera", "graft", and "surgery". The search resulted in 1596 articles, of which we evaluated 192 as relevant. The relevant articles were sorted chronologically and according to the method of using scleral grafts, which enabled the development of a review article.
RESULTS
The sclera has been routinely used in ophthalmology since the 1950s in many different indications. Some of these indications have become practically obsolete over time (for example, use in the surgical management of retinal detachment), but a large number still find application today (especially use in glaucoma or oculoplastic surgery, or as a patch for a defect in the sclera or cornea).
CONCLUSION
Even though allogeneic sclera is currently used less frequently in ophthalmology compared to other tissue banking products and the range of its indications has partially narrowed, it remains a useful material due to its availability and properties.
Topics: Sclera; Humans; Ophthalmologic Surgical Procedures; Eye Diseases
PubMed: 38925901
DOI: 10.31348/2024/11 -
Ceska a Slovenska Oftalmologie :... 2024The primary aim of this study is to evaluate the repeatability of noninvasive break-up time (NIBUT) measurement by keratograph when it is determined from one, two or...
AIM
The primary aim of this study is to evaluate the repeatability of noninvasive break-up time (NIBUT) measurement by keratograph when it is determined from one, two or three partial measurements, and to recommend a suitable methodology for practice. Another goal is to verify that repeated measurements do not affect the measured value.
MATERIAL AND METHODS
Thirty-eight healthy volunteers (30 women and 8 men) aged between 19 and 50 years old were included in the study, in which only one eye of each volunteer was measured. The study was designed as a prospective one. Each subject adapted to the local conditions of the laboratory for 15 minutes and subsequently underwent two series of NIBUT measurements (test, retest) on an OCULUS 3 Keratograph. The minimum time interval between the two series was 10 minutes, in which each series contained three partial measurements approximately 3 three measurements in the given series. Repeatability was assessed by a Bland-Altman analysis and expressed as a repeatability coefficient. In every case, only the time of the first break-up of the tear film was monitored.
RESULTS
The statistical analysis did not show statistically significant differences both between partial measurements of NIBUT in the individual series (p = 0.92, p = 0.81) and when comparing all six measurements (p = 0.95). The mean values of the partial measurements ranged from 13.6 s to 14.4 s. The repeatability coefficients were found to be 15.0 s, 12.1 s and 10.0 s for methodologies A, B and C, respectively. A supplementary analysis for 12 eyes with low NIBUT (< 10 s) showed statistically significantly better repeatability in this group, with coefficients of 7.0 s (methodology A), 6.0 s (B) and 4.6 s (C).
CONCLUSION
Determination of NIBUT from three consecutive measurements (with a sufficient interval of ideally a few minutes) significantly improves repeatability. Such repeated NIBUT measurements do not have a significant effect on the measured value. The mentioned methodology for measuring NIBUT on a keratograph can be recommended for use in practice.
Topics: Humans; Adult; Female; Male; Middle Aged; Reproducibility of Results; Young Adult; Tears; Diagnostic Techniques, Ophthalmological; Cornea; Prospective Studies
PubMed: 38925898
DOI: 10.31348/2024/26 -
Ceska a Slovenska Oftalmologie :... 2024To demonstrate a rare case of ciliary body leiomyoma in our patient Case report: A 72-year-old female reported to our clinic for a preventive examination, upon which we...
AIM
To demonstrate a rare case of ciliary body leiomyoma in our patient Case report: A 72-year-old female reported to our clinic for a preventive examination, upon which we found a dome-shaped grey-brownish mass on the retinal periphery. After completing gonioscopic and ultrasound examinations, we referred the patient to a specialist facility. Due to a finding of suspicious malignant melanoma, we completed the MRI scan and recommended enucleation of the eyeball. A histopathological examination showed a leiomyoma of the ciliary body.
CONCLUSION
The aim of this case report is to demonstrate the difficulty of intraocular leiomyoma diagnosis. Only immunohistochemical examination differentiated the tumor from malignant melanoma and determined the diagnosis of ciliary body leiomyoma. Perhaps because of the extreme rarity of this type of tumor, we often neglect to consider a diagnosis of leiomyoma.
Topics: Humans; Leiomyoma; Female; Ciliary Body; Aged; Uveal Neoplasms; Melanoma; Diagnosis, Differential
PubMed: 38925897
DOI: 10.31348/2024/30 -
Ceska a Slovenska Oftalmologie :... 2024This research was conducted to determine the normal values of choroidal thickness in healthy individuals and to evaluate the relationship between this thickness and age,...
AIM
This research was conducted to determine the normal values of choroidal thickness in healthy individuals and to evaluate the relationship between this thickness and age, gender, refraction, axial length and average macular thickness using OCT.
MATERIAL AND METHOD
In the study, the right eyes of 400 healthy individuals (234 women, 166 men) between the ages of 4 and 70 years, who applied to the Department of Ophthalmology outpatient clinic for examination, were evaluated.
RESULTS
Macular thickness, macular volume, and foveal thickness were found to be 249.12 ±21.32 µm, 9.98 ±0.5 µm3 and 280 ±13.45 µm, respectively. According to linear regression analysis, a negative correlation was detected between age and subfoveal choroidal thickness (p < 0.05). It was determined that foveal thickness, retinal volume and average retinal thickness were higher in men, and foveal thickness increased with age (p < 0.05).
CONCLUSION
As a result of the research, it was determined that age is an important factor affecting choroidal thickness. It is thought that, in future, improving in vivo imaging of the choroid and measuring choroidal thickness using OCT will facilitate understanding of the pathophysiological basis of many ophthalmological diseases.
Topics: Humans; Male; Choroid; Tomography, Optical Coherence; Female; Middle Aged; Adult; Aged; Macula Lutea; Young Adult; Adolescent; Child; Child, Preschool; Reference Values
PubMed: 38925894
DOI: 10.31348/2024/24 -
Ceska a Slovenska Oftalmologie :... 2024To investigate the concordance between the corneal power determined by various approaches with two tomographers (MS-39® and Galilei G6®) and the clinical history...
AIMS
To investigate the concordance between the corneal power determined by various approaches with two tomographers (MS-39® and Galilei G6®) and the clinical history method (CHM) in patients undergoing photorefractive surgery with excimer laser for myopic errors.
MATERIAL AND METHODS
Prospective cohort study. Patients undergoing keratorefractive surgery, and having pre- and postoperative keratometries, and tomographies, were included.
RESULTS
In 90 eyes, the differences in the power estimated by the CHM and the one determined by four approaches with the corneal tomographers, which included measurements of the posterior cornea, did not show statistically significant differences in their averages. However, the 95% limits of agreement were very wide. After obtaining regression formulas to adjust the values of these four variables, the results of the agreement analysis were similar.
CONCLUSION
Although certain values either directly determined or derived from measurements with the Galilei® and MS-39®corneal tomographers, approximated the estimated value of postoperative corneal power according to the CHM, due to the amplitude of their limits of agreement, these calculations must be taken with care, because they may not be accurate in a given eye.
Topics: Humans; Cornea; Myopia; Adult; Prospective Studies; Male; Female; Photorefractive Keratectomy; Young Adult; Corneal Topography; Lasers, Excimer; Refraction, Ocular
PubMed: 38925892
DOI: 10.31348/2024/23 -
Journal of Biomedical Materials... Jul 2024Sensorineural hearing loss (SNHL) is mainly caused by injury or loss of hair cells (HCs) and associated spiral ganglion neurons (SGNs) in the inner ear. At present,...
Sensorineural hearing loss (SNHL) is mainly caused by injury or loss of hair cells (HCs) and associated spiral ganglion neurons (SGNs) in the inner ear. At present, there is still no effective treatment for SNHL in clinic. Recently, advances in organoid bring a promising prospect for research and treatment of SNHL. Meanwhile, three-dimensional (3D) printing provides a tremendous opportunity to construct versatile organoids for tissue engineering and regenerative medicine. In this study, gelatin (Gel), sodium alginate (SA), and polyvinyl alcohol (PVA) were used to fabricate biomimetic scaffold through 3D printing. The organ of Corti derived from neonatal mice inner ear was seeded on the PVA/Gel/SA scaffold to construct organ of Corti organoid. Then, the organ of Corti organoid was used to study the potential protective effects of berberine sulfate on neomycin-juried auditory HCs and SGNs. The results showed that the PVA/Gel/SA biomimetic 3D scaffolds had good cytocompatibilities and mechanical properties. The constructed organoid could maintain organ of Corti activity well in vitro. In addition, the injury intervention results showed that berberine sulfate could significantly inhibit neomycin-induced HC and SGN damage. This study suggests that the fabricated organoid is highly biomimetic to the organ of Corti, which may provide an effective model for drug development, cell and gene therapy for SNHL.
Topics: Animals; Organ of Corti; Mice; Berberine; Tissue Scaffolds; Organoids; Printing, Three-Dimensional; Alginates; Gelatin; Hair Cells, Auditory; Tissue Engineering; Polyvinyl Alcohol; Hearing Loss, Sensorineural; Spiral Ganglion
PubMed: 38923766
DOI: 10.1002/jbm.b.35439 -
Translational Vision Science &... Jun 2024This study investigated the distribution of fundus tessellation density (FTD) in a Chinese pediatric population and its potential in reflecting early myopic maculopathy...
PURPOSE
This study investigated the distribution of fundus tessellation density (FTD) in a Chinese pediatric population and its potential in reflecting early myopic maculopathy (tessellated fundus).
METHODS
Participants were enrolled from kindergartens, primary schools, and middle schools, with cluster sampling in Shanghai, China. A series of ophthalmic examinations was conducted. Based on fundus photograph, FTD was quantitatively assessed using an artificial intelligence algorithm, and tessellated fundus was diagnosed by well-trained ophthalmologists.
RESULTS
A total of 14,234 participants aged four to 18 years were included, with 7421 boys (52.1%). Tessellated fundus was observed in 2200 (15.5%) participants. The median of FTD was 0.86% (range 0.0-42.1%). FTD increased with age and axial length. In the logistics regression, larger FTD was independently associated with tessellated fundus (P < 0.001). The area under curves of receiver operating characteristic curve for categorizing tessellated fundus using FTD was 0.774, and the cutoff point of FTD was 2.22%.
CONCLUSIONS
The density of fundus tessellation was consistent with the severity of myopia. FTD could help diagnose the early stage of myopic maculopathy, tessellated fundus, providing a new pattern for myopia screening and detection of early myopic fundus changes.
TRANSLATIONAL RELEVANCE
Quantification of fundus tessellation with artificial intelligence could help detect early myopic maculopathy.
Topics: Humans; Male; Adolescent; Child; Female; Fundus Oculi; Child, Preschool; China; ROC Curve; Myopia, Degenerative; Macular Degeneration; Artificial Intelligence; Photography
PubMed: 38922627
DOI: 10.1167/tvst.13.6.22 -
International Ophthalmology Jun 2024To examine the rate of ciliary body detachment in patients with choroidal detachment following glaucoma surgery and its effect on the clinical course, management, and... (Observational Study)
Observational Study
PURPOSE
To examine the rate of ciliary body detachment in patients with choroidal detachment following glaucoma surgery and its effect on the clinical course, management, and prognosis.
METHODS
A prospective observational case-series study. Patients with choroidal detachment following glaucoma surgery in 2018-2019 were included. All underwent complete ophthalmological examination and ultrasound biomicroscopy for evaluation of the presence and extent of ciliary body detachment. Follow-up examinations including ultrasound biomicroscopy scans were performed at 1 week, 1 month, 3 months, and 6 months.
RESULTS
Eight patients (8 eyes) were enrolled, 4 male and 4 female, of mean age 72 years (range 60-83). Five patients underwent trabeculectomy with mitomycin C (0.02%), which was combined with phacoemulsification cataract extraction in one; two underwent Ahmed glaucoma valve implantations, and one underwent ab-interno Xen45 gel stent implantation with mitomycin C (0.02%). The mean intraocular pressure was 26.0 ± 7.65 mmHg preoperatively, dropping to 6.9 ± 2.64 mmHg on first postoperative day one. Mean time from surgery to diagnosis of choroidal detachment was 11.6 ± 5.73 days. Ciliary body detachment was identified by ultrasound biomicroscopy in all patients, ranging between one and four quadrants. All patients were treated with topical steroids and cycloplegics; three (37.5%) received oral steroids. No surgical intervention for the choroidal or ciliary body detachments was indicated.
CONCLUSIONS
In this real-world prospective study, concurrent ciliary body detachment was identified in all patients who presented with choroidal detachment following glaucoma surgery. This observation may deepen our understanding of the mechanism underlying the hypotony that is often seen after glaucoma surgery.
Topics: Humans; Male; Female; Ciliary Body; Aged; Prospective Studies; Middle Aged; Aged, 80 and over; Intraocular Pressure; Choroidal Effusions; Glaucoma; Postoperative Complications; Microscopy, Acoustic; Follow-Up Studies; Trabeculectomy; Glaucoma Drainage Implants; Visual Acuity; Uveal Diseases; Tomography, Optical Coherence
PubMed: 38922523
DOI: 10.1007/s10792-024-03219-1