Frontiers in Surgery 2024Total knee arthroplasty (TKA) is a common and effective procedure. Optimizing pain control and reducing postoperative discomfort are essential for patient satisfaction....
BACKGROUND
Total knee arthroplasty (TKA) is a common and effective procedure. Optimizing pain control and reducing postoperative discomfort are essential for patient satisfaction. No studies have examined the safety and efficacy of intra-articular corticosteroid injections following TKA. This study aims to examine the safety and efficacy of corticosteroids in intra-articular multimodal analgesic injections.
MATERIALS AND METHODS
This was a historically controlled study conducted at a single academic institution. Before May 2019, patients received an intra-articular cocktail injection without corticosteroids during surgery, referred to as the non-corticosteroid (NC) group. After June 2019, intraoperatively, patients received an intra-articular cocktail injection containing corticosteroids, referred to as the corticosteroid (C) group. Finally, 738 patients were evaluated, 370 in the C cohort and 368 in the NC cohort. The mean follow-up duration was 30.4 months for the C group and 48.4 months for the NC group.
RESULTS
The mean VAS scores at rest on postoperative day (POD) 1 (2.35) and POD3 (3.88) were significantly lower in the C group than those in the NC group, which were 2.86 (POD1) and 5.26 (POD3) ( < 0.05). Walking pain in the C group (4.42) was also significantly lower than that (5.96) in the NC group on POD3 ( < 0.05). Patients in the C group had a significantly higher mean range of motion (ROM) (92.55) on POD3 than that (86.38) in the NC group. The mean time to straight leg raise for group C (2.77) was significantly shorter than that (3.61) for the NC group ( < 0.05). The C group also had significantly fewer rescue morphine (1.9) and metoclopramide (0.21) uses per patient than the NC group, which were 3.1 and 0.24, respectively. No significant differences in fever or vomiting rates between groups were found. Patients in neither group developed periprosthetic joint infections or skin necrosis. One patient in the C group suffered from wound dehiscence, and the wound healed well after debridement. No patient died or had a re-operation in either group.
CONCLUSIONS
This pilot trial found that intra-articular injection of multimodal analgesia (including corticosteroids) reduced initial postoperative pain, increased ROM in the early postoperative days (up to POD3), and did not increase wound complications or infection rates in approximately 30 months of follow-up.
PubMed: 38919978
DOI: 10.3389/fsurg.2024.1279462 -
The Iowa Orthopaedic Journal 2024Bernese periacetabular osteotomy (PAO) improves symptoms and delays degenerative changes in patients with acetabular dysplasia. Yet, eventual total hip arthroplasty...
BACKGROUND
Bernese periacetabular osteotomy (PAO) improves symptoms and delays degenerative changes in patients with acetabular dysplasia. Yet, eventual total hip arthroplasty (THA) is needed in many of these patients. The impact of PAO on subsequent THA outcomes is not well defined.
THE PURPOSE OF THIS STUDY IS TO DEFINE
1) clinical outcomes, 2) post-operative complications and 3) implant survivorship for patients undergoing THA after prior ipsilateral PAO.
METHODS
A retrospective review was conducted at three institutions to identify individuals undergoing THA after ipsilateral PAO surgery with minimum 1 year follow up. Patient reported outcome measures (PROMs) were collected preoperatively and at final follow-up. Surgical details, radiographic and clinical outcomes, and major complications according to the modified Dindo-Clavien classification system were identified through review of the medical record. Regression analysis and student's t-test were used to compare pre- and post-operative outcome scores. Kaplan-Meier analysis was performed to estimate reoperation-free survivorship.
RESULTS
A total of 113 THA in 112 patients were identified with initial review. 103 hips had a minimum of 1-year follow-up and an average follow of 5 ± 4 years (range, 1 to 20). 10 hips (9%) were lost to follow-up leaving 103 (91%) hips available for review with a minimum of 1-year follow-up (mean = 5 years). Mean interval from PAO to THA was 7.7 years (range, 2-15). The average post-operative mHHS improved 37 points (50 to 87, P < 0.001) when compared to pre-operative scores. Eight patients (7.1%) experienced a major grades III-V) surgical complication. These included 2 cases of instability, 2 cases of acetabular loosening, and one case each of periprosthetic fracture, wound dehiscence, periprosthetic infection, acetabular loosening and pneumonia. Failures occurred early at average 3.2 years and survivorship analysis for all-cause revision demonstrated 96% survivorship at both 5 and 10 years.
CONCLUSION
THA after PAO achieves significant clinical improvement and satisfactory survivorship (96%) at mid-term follow-up, with a major complication rate of 7.1%. .
Topics: Humans; Arthroplasty, Replacement, Hip; Osteotomy; Retrospective Studies; Female; Male; Adult; Reoperation; Acetabulum; Middle Aged; Follow-Up Studies; Treatment Outcome; Young Adult; Postoperative Complications; Hip Joint
PubMed: 38919338
DOI: No ID Found -
Journal of Stomatology, Oral and... Jun 2024Dermal substitutes are classically used in a 2-stage procedure followed by skin graft for wound healing. This study aims to evaluate the possibility to use an...
A comparative prospective study between the outcomes of one-stage Pelnac reconstruction and full thickness skin graft on donor site healing in the radial forearm and fibula flaps.
OBJECTIVES
Dermal substitutes are classically used in a 2-stage procedure followed by skin graft for wound healing. This study aims to evaluate the possibility to use an alternative technique for radial forearm and fibula donor sites coverage using one-stage Pelnac reconstruction.
MATERIALS AND METHODS
21 patients who underwent radial forearm and fibula flaps harvest for reconstruction of head and neck defects after oncological surgery were enrolled in the study. 13 patients were treated by one-stage Pelnac reconstruction of the donor site defect, 8 patients underwent full thickness skin graft. The Vancouver Scar Scale was used to evaluate the scar quality.
RESULTS
Most patients treated with one-stage Pelnac reconstruction showed good healing of the flap donor site, with minor complications, scar quality comparable to other treatment options and unimpaired function of the implicated limb. One patient had wound dehiscence at the radial forearm site, which was treated with secondary full thickness skin graft. In the group treated with FTSG we had three patients that developed complications, such as dehiscence of the graft and seroma. Overall, we reported comparable satisfaction with donor sites both for aesthetic and functional outcomes, in both groups of patients.
CONCLUSION
The use of Pelnac without a following skin graft provides a viable method for the reconstruction of radial forearm and fibula flaps donor site. A longer postoperative care is needed, but the long-term aesthetic and functional results are satisfactory in comparison with full thickness skin graft.
PubMed: 38914140
DOI: 10.1016/j.jormas.2024.101949 -
Journal of Indian Association of... 2024Closure of congenital body wall defects in children can be a challenging task for the pediatric Surgeon. Biological prosthesis has been increasingly used for high-risk...
AIMS
Closure of congenital body wall defects in children can be a challenging task for the pediatric Surgeon. Biological prosthesis has been increasingly used for high-risk wound closure in adult patients with excellent outcomes and use in the pediatric population has also been reported. Here, we aim to study the outcome of abdominal wound repair with a tissue-engineered acellular bovine pericardial patch.
METHODS
Over a period of 21 months, a total of 15 children had undergone abdominal wound repair with bioprostheses, i.e., bovine pericardial patch at our institute. Patient demographics, cause of defect, an indication of patch use, rate of infection, postoperative recovery, recurrence, and outcome were studied.
RESULTS
A total of 15 patients underwent abdominal wall closure with acellular bovine pericardial patch. Nine out of 15 patients were neonates, of whom five had gastroschisis, two had a congenital diaphragmatic hernia, and two had ruptured omphalocele major. Of the rest 6 patients, 2 were patients of bladder exstrophy, 2 were older children of congenital diaphragmatic hernia with incisional hernias, and 2 were older children with omphalocele major. Out of the five patients with gastroschisis, two died during the early postoperative period due to sepsis. The wound healed in the rest 13 patients with mild skin dehiscence in two patients. Only one child had a recurrence.
CONCLUSION
Reconstruction with acellular bovine pericardial patch is a viable option in children with high-risk abdominal wounds as it allows tensionless repair with excellent healing and minimal complications. Recurrence, if any, may disappear with time as remodeling of the prosthesis occurs along with the growth of the body wall of the child.
PubMed: 38912025
DOI: 10.4103/jiaps.jiaps_230_23 -
JPRAS Open Sep 2024Breast reconstruction following mastectomy is a critical component of breast cancer treatment, aimed at improving patient quality of life. However, the management is...
BACKGROUND
Breast reconstruction following mastectomy is a critical component of breast cancer treatment, aimed at improving patient quality of life. However, the management is fraught with potential complications, including skin necrosis and wound dehiscence, which can significantly impact clinical outcomes.
CASE PRESENTATION
We report a unique case of a patient, 5 years post-breast reconstruction following mastectomy and radiation therapy, who developed severe skin necrosis and wound dehiscence due to a brown recluse spider bite on the reconstructed breast. The complication necessitated the debridement of skin, removal of the implant, and further reconstruction with a latissimus flap.
DISCUSSION
The case underscores the unusual etiology of spider bite-induced necrosis in breast reconstruction and highlights the challenges and strategic considerations in managing such complications. Upon presentation, the patient's affected breast area showed signs of extensive necrosis and wound dehiscence, directly attributed to the cytotoxic effects of the brown recluse spider's venom. The venom's pathophysiology involves a complex cascade, leading to local and systemic effects. The local effects, marked by dermonecrosis, com- promised skin integrity in this instance. Systemic effects, not observed in this patient but potentially severe, can include hemolysis, coagulopathy, and acute renal failure, highlighting the seriousness of brown recluse spider bites.
CONCLUSION
In conclusion, this case illustrates the complexities of managing breast reconstruction post-mastectomy complications, particularly those caused by external factors such as brown recluse spider bites. It highlights the need for meticulous attention to unusual etiologies of necrosis and dehiscence, demonstrating the importance of adaptable surgical strategies and a thorough understanding of venom pathophysiology in ensuring successful patient outcomes.
PubMed: 38911670
DOI: 10.1016/j.jpra.2024.05.008 -
Journal of Maxillofacial and Oral... Jun 2024To assess the efficacy of Herbert cannulated bone screw versus Lag screw in fixation of oblique mandibular fractures.
PURPOSE
To assess the efficacy of Herbert cannulated bone screw versus Lag screw in fixation of oblique mandibular fractures.
MATERIALS AND METHOD
Study composed of two groups of 20 patients each and descriptive statistics were performed with value set at 0.05 with confidence interval of 95%. Group A was treated by Titanium Lag screws; while, Group B was treated by Titanium Herbert Cannulated Bone Screws for the management of oblique mandibular fractures. Postoperatively, all the patients were evaluated clinically and radiographically by recording the incidence of complications (if any) which included trismus, neurosensory deficit, swelling, infection. Parameters such as occlusal discrepancy, rigid fixation (interfragmentary gap) and duration of surgery were also recorded for all the patients.
RESULTS
All the patients were followed for a period of three months. Difference in mouth opening was found to be statistically significant during 1st month follow-up (-Value-0.002). Postoperatively, the mean interfragmentary gap in Group A was significantly more than Group B (-Value-0.000). Other parameters like neurosensory deficits, occlusal discrepancies, chewing efficiency, stability of fractured fragments and post-operative complications in terms of swelling, hardware exposure, radiolucency surrounding screw and wound dehiscence did not show any statistically significant difference.
CONCLUSION
The obtained results showed that both lag screws and Herbert cannulated bone screws fulfill the treatment goals of adequate reduction, fixation and stabilization of oblique mandibular fractures. Herbert screws have shown to have better results in terms of interfragmentary gap reduction as compared to lag screws.
PubMed: 38911422
DOI: 10.1007/s12663-023-02095-z -
Cureus May 2024Background Abdominal wound dehiscence, a serious postoperative issue, remains a significant concern for surgeons due to its potential to increase patient mortality and...
Background Abdominal wound dehiscence, a serious postoperative issue, remains a significant concern for surgeons due to its potential to increase patient mortality and morbidity. Disruption can occur at any point after surgery, sparking debate over the optimal closure method for midline vertical abdominal wounds. Therefore, it's crucial to determine the safest approach. Our randomized clinical trial is planned to compare the risk of a burst abdomen associated with the Hughes abdominal closure technique to that of continuous abdominal closure. Methods All patients >18 years scheduled for emergency midline laparotomy were randomly assigned into two groups using computer-generated random numbers: Group A underwent Hughes repair (12 patients) and Group B underwent continuous closure (17 patients). Preoperative data, including patient demographics, and postoperative outcomes, such as time for rectus closure, wound dehiscence, surgical site infection (SSI), and length of hospital stay, were documented for analysis. Results The study found that the average patient age was 37.89 years, with more males than females. Both groups had an equal distribution of co-morbidities (p = 0.468), but none of these factors were statistically significant. Burst abdomen occurred in 25% of group A and 41.1% of group B (p = 0.367, not significant). Incisional hernia was absent in both groups. Surgical site infection (p = 0.119) and respiratory complications (p = 0.16) were not statistically significant between groups. However, in group A, the regressive analysis showed significant associations between burst abdomen, surgical site infection (p = 0.018), and respiratory complications (p = 0.007), while in group B, these associations were not significant (p = 0.252 for SSI and p = 0.906 for respiratory complications). Conclusion The occurrence of burst abdomen and closure time differences between continuous and Hughes techniques were not significant. The Hughes technique was quicker to learn (32 vs. 22 minutes). Burst abdomen was more common in continuous closure (group A: 25% vs. group B: 41%), favoring the Hughes technique. Factors like age, gender, and others didn't significantly impact the burst abdomen in either group.
PubMed: 38910747
DOI: 10.7759/cureus.60816 -
Biomaterials Jun 2024Conventional wound approximation devices, including sutures, staples, and glues, are widely used but risk of wound dehiscence, local infection, and scarring can be...
Conventional wound approximation devices, including sutures, staples, and glues, are widely used but risk of wound dehiscence, local infection, and scarring can be exacerbated in these approaches, including in diabetic and obese individuals. This study reports the efficacy and quality of tissue repair upon photothermal sealing of full-thickness incisional skin wounds using silk fibroin-based laser-activated sealants (LASEs) containing copper chloride salt (Cu-LASE) or silver nanoprisms (AgNPr-LASE), which absorb and convert near-infrared (NIR) laser energy to heat. LASE application results in rapid and effective skin sealing in healthy, immunodeficient, as well as diabetic and obese mice. Although lower recovery of epidermal structure and function was seen with AgNPr-LASE sealing, likely because of the hyperthermia induced by laser and presence of this material in the wound space, this approach resulted in higher enhancement in recovery of skin biomechanical strength compared to sutures and Cu-LASEs in diabetic, obese mice. Histological and immunohistochemical analyses revealed that AgNPr-LASEs resulted in significantly lower neutrophil migration to the wound compared to Cu-LASEs and sutures, indicating a more muted inflammatory response. Cu-LASEs resulted in local tissue toxicity likely because of effects of copper ions as manifested in the form of a significant epidermal gap and a 'depletion zone', which was a region devoid of viable cells proximal to the wound. Compared to sutures, LASE-mediated sealing, in later stages of healing, resulted in increased angiogenesis and diminished myofibroblast activation, which can be indicative of lower scarring. AgNPr-LASE loaded with vancomycin, an antibiotic drug, significantly lowered methicillin-resistant Staphylococcus aureus (MRSA) load in a pathogen challenge model in diabetic and obese mice and also reduced post-infection inflammation of tissue compared to antibacterial sutures. Taken together, these attributes indicate that AgNPr-LASE demonstrated a more balanced quality of tissue sealing and repair in diabetic and obese mice and can be used for combating local infections, that can result in poor healing in these individuals.
PubMed: 38908232
DOI: 10.1016/j.biomaterials.2024.122668 -
Techniques in Coloproctology Jun 2024Four patients with rectal cancer required reconstruction of a defect of the posterior vaginal wall. All patients received neoadjuvant (chemo)radiotherapy, followed by an...
Four patients with rectal cancer required reconstruction of a defect of the posterior vaginal wall. All patients received neoadjuvant (chemo)radiotherapy, followed by an en bloc (abdomino)perineal resection of the rectum and posterior vaginal wall. The extent of the vaginal defect necessitated closure using a tissue flap with skin island. The gluteal turnover flap was used for this purpose as an alternative to conventional more invasive myocutaneous flaps (gracilis, gluteus, or rectus abdominis). The gluteal turnover flap was created through a curved incision at a maximum width of 2.5 cm from the edge of the perineal wound, thereby creating a half-moon shape skin island. The subcutaneous fat was dissected toward the gluteal muscle, and the gluteal fascia was incised. Thereafter, the flap was rotated into the defect and the skin island was sutured into the vaginal wall defect. The contralateral subcutaneous fat was mobilized for perineal closure in the midline, after which no donor site was visible.The duration of surgery varied from 77 to 392 min, and the hospital stay ranged between 3 and 16 days. A perineal wound dehiscence occurred in two patients, requiring an additional VY gluteal plasty in one patient. Complete vaginal and perineal wound healing was achieved in all patients. The gluteal turnover flap is a promising least invasive technique to reconstruct posterior vaginal wall defects after abdominoperineal resection for rectal cancer.
Topics: Humans; Female; Vagina; Buttocks; Rectal Neoplasms; Middle Aged; Plastic Surgery Procedures; Surgical Flaps; Aged; Perineum; Operative Time; Treatment Outcome
PubMed: 38907171
DOI: 10.1007/s10151-024-02941-3 -
International Ophthalmology Jun 2024To clarify the characteristics of intraocular lens (IOL) dislocation requiring IOL suture or intraocular scleral fixation.
PURPOSE
To clarify the characteristics of intraocular lens (IOL) dislocation requiring IOL suture or intraocular scleral fixation.
METHODS
This retrospective consecutive case series included 21 eyes (21 patients) who required sutured or sutureless intrascleral IOL fixation following IOL extraction owing to IOL dislocation at the outpatient clinic in the Department of Ophthalmology, Saitama Red Cross Hospital, Japan, between January and December 2019. Medical records were retrospectively reviewed for background diseases, location of the dislocated IOL (intracapsular/extracapsular), insertion of a capsular tension ring (CTR), and the period from IOL insertion to dislocation.
RESULTS
We included 21 eyes of 21 patients who required IOL suture or intrascleral fixation for IOL dislocation at our clinic from January to December 2019 were included. The most common background disease was pseudoexfoliation syndrome (four cases), followed by atopic dermatitis, dysplasia/dehiscence of the zonule, post-retinal detachment surgery, high myopia, and uveitis (three cases each). At the time of dislocation, the IOLs were either intracapsular (16 cases, including 3 cases with CTR insertion) or extracapsular (5 cases). The time from IOL insertion to IOL dislocation was 13.7 ± 8.1 years (maximum: 31.3 years, minimum: 1.7 years).
CONCLUSIONS
In this study, all 21 cases represented late IOL dislocations occurring after 3 months postoperatively. Among these late IOL dislocation cases, IOL dislocation occurred in a short-medium period of time, especially in those with CTR insertion and weakness/dehiscence of the zonule, with an average of 3 to 5 years postoperatively. We propose referring to these cases as intermediate-term IOL dislocation.
Topics: Humans; Retrospective Studies; Female; Male; Aged; Middle Aged; Artificial Lens Implant Migration; Lenses, Intraocular; Aged, 80 and over; Time Factors; Visual Acuity; Adult; Sclera; Suture Techniques; Follow-Up Studies; Lens Implantation, Intraocular; Postoperative Complications
PubMed: 38904711
DOI: 10.1007/s10792-024-03166-x