Frontiers in Cardiovascular Medicine 2022Multiparametric models have shown better risk stratification in Brugada syndrome. Recently, these models have been validated in different populations.
BACKGROUND
Multiparametric models have shown better risk stratification in Brugada syndrome. Recently, these models have been validated in different populations.
AIMS
To perform a systematic review and meta-analysis of the predictive performance of three validated multiparametric models (Delise model, Sieria model, and Shanghai score).
METHODS
We searched PubMed, Embase, MEDLINE, Web of Science, and Ovid for studies validating the risk multiparametric model. A Sieria score > 2 and Shanghai score ≥ 4 were considered to indicate higher risk. Performance estimates were summarized using a random-effects model.
RESULTS
Seven studies were included, with sample sizes of 111-1,613. The follow-up duration was 3.3-10.18 years. The Sieria model had a pooled area under the curve (AUC), sensitivity, and specificity of 0.71 [95% confidence interval (CI): 0.67-0.75], 57% (95% CI: 35-76), and 71% (95% CI: 62-79), respectively. The Shanghai score had an AUC of 0.63-0.71, 68.97-90.67% sensitivity, and 43.53-63.43% specificity. The AUC of the Delise model was 0.77-0.87; however, the optimal cut-off was not identified.
CONCLUSIONS
The three models exhibited moderate discriminatory ability for Brugada syndrome. The Sieria model has poor sensitivity and moderate specificity, whereas the Shanghai score has poor specificity and moderate sensitivity.
PubMed: 35497979
DOI: 10.3389/fcvm.2022.859771 -
Cardiology 2022Heart failure (HF) is a severe and terminal stage of various heart diseases. Left ventricular assist devices (LVADs) are relatively mature and have contributed to the...
INTRODUCTION
Heart failure (HF) is a severe and terminal stage of various heart diseases. Left ventricular assist devices (LVADs) are relatively mature and have contributed to the treatment of end-stage HF. Ventricular arrhythmia (VA) is a common complication after LVAD implantation, including ventricular tachycardia and ventricular fibrillation, both of which may cause abnormal circulation.
METHODS
A literature search was conducted in the PubMed database, "Ventricular Arrhythmia" OR "VA" OR "Arrhythmia" OR "Ventricular Tachycardia," OR "Ventricular Fibrillation" AND "LVAD" OR "Left Ventricular Assist Device" OR "Heart Assist Device" as either keywords or MeSH terms, the authors screened the titles and abstracts of the articles. Eventually, 12 original research articles were retrieved.
RESULTS
The 0.83 [95% CI: 0.77, 0.89] of patients were male. A whole of 53% [95% CI: 0.25, 0.81] of VA patients had a history of atrial fibrillation and 61% [95% CI: 0.52, 0.69] had a history of VA. 39% [95% CI: 0.29, 0.49] of the participants had no prior history of VA and experienced new VA following CF-LVAD implantation. Following CF-LVAD implantation, 59% [95% CI: 0.51, 0.67] of patients developed early VA (VA ≤30 days). The 30-day mortality rate of patients was 4% [95% CI: 0.01, 0.07]. And overall mortality was 28% [95% CI: 0.15, 0.41]. The reported incidence of VA after LVAD implantation is not identical in different medical centers and ranges from 20% to 60%. The mechanism of VA after LVAD implantation is summarized as primary cardiomyopathy-related, device mechanical stimulation, myocardial scarring, ventricular displacement, electrolyte regulation, and other processes.
CONCLUSIONS
A preoperative VA history is considered a predictor of VA following LVAD implantation in most studies. Multiple mechanisms and factors, such as prevention of "suction events," ablation, and implantable cardioverter defibrillator, should be considered for the prevention and treatment of postoperative VA in patients requiring long-term VAD treatment. This study provides a reference for the clinical application of LAVD and the prevention of postoperative VA after LVAD implantation. Future multicenter prospective studies with uniform patient follow-up are needed to screen for additional potential risk factors and predictors. These studies will help to define the incidence rate of VA after LAVD implantation. As a result, we provide guidance for the selection of preventive intervention.
Topics: Arrhythmias, Cardiac; Female; Heart Failure; Heart-Assist Devices; Humans; Male; Risk Factors; Tachycardia, Ventricular; Treatment Outcome; Ventricular Fibrillation
PubMed: 35483328
DOI: 10.1159/000524779 -
PloS One 2022The COVID-19 pandemic, ageing populations and the increasing shortage of skilled workers pose great challenges for the delivery of supplies for people with and without...
BACKGROUND
The COVID-19 pandemic, ageing populations and the increasing shortage of skilled workers pose great challenges for the delivery of supplies for people with and without care needs. The potential of drones, as unmanned air vehicles, in healthcare are huge and are discussed as an effective new way to delivery urgent medicines and medical devices, especially in rural areas. Although the advantages are obvious, perspectives of users are important particularly in the development process. Investigating human drone interaction could potentially increase usefulness and usability. The present study aims to perform a systematic scoping review on experimental studies examining the human drone interaction in deliveries of drugs and defibrillators.
METHODS
Two databases (MEDLINE and CINAHL) and references of identified publications were searched without narrowing the year of publication or language. Studies that investigated the human drone interaction or medical delivery with drones in an experimental manner were included (research articles). All studies that only simulated the delivery process were excluded.
RESULTS
The search revealed 83 publications with four studies being included. These studies investigated the user experience of drone delivered defibrillators, but no study was identified that investigated the human drone interaction in the delivery of drugs. Three categories of human drone interaction were identified: landing, handover, and communications. Regarding landing and handover, the most important issue was the direct physical contact with the drone while regarding communications users need clearer instructions about drone´s direction, sound and look like.
DISCUSSION
The identified studies used technology-driven approaches by investigating human drone interaction in already existing technologies. Users must become integral part of the whole development process of medical drone services to reduce concerns, and to improve security, usability and usefulness of the system. Human drone interaction should be developed according to the identified categories of human drone interaction by using demand- and technology-driven approaches.
Topics: COVID-19; Delivery of Health Care; Humans; Pandemics; Unmanned Aerial Devices
PubMed: 35482656
DOI: 10.1371/journal.pone.0267664 -
Biology Mar 2022Cardiolaminopathies are a heterogeneous group of disorders which are due to mutations in the genes encoding for nuclear lamins or their binding proteins. The whole... (Review)
Review
Cardiolaminopathies are a heterogeneous group of disorders which are due to mutations in the genes encoding for nuclear lamins or their binding proteins. The whole spectrum of cardiac manifestations encompasses atrial arrhythmias, conduction disturbances, progressive systolic dysfunction, and malignant ventricular arrhythmias. Despite the prognostic significance of cardiac involvement in this setting, the current recommendations lack strong evidence. The aim of our work was to systematically review the current data on the main cardiovascular outcomes in cardiolaminopathies. We searched PubMed/Embase for studies focusing on cardiovascular outcomes in mutation carriers (atrial arrhythmias, ventricular arrhythmias, sudden cardiac death, conduction disturbances, thromboembolic events, systolic dysfunction, heart transplantation, and all-cause and cardiovascular mortality). In total, 11 studies were included (1070 patients, mean age between 26-45 years, with follow-up periods ranging from 2.5 years up to 45 ± 12). When available, data on the -mutated population were separately reported (40 patients). The incidence rates (IR) were individually assessed for the outcomes of interest. The IR for atrial fibrillation/atrial flutter/atrial tachycardia ranged between 6.1 and 13.9 events/100 pts-year. The IR of atrial standstill ranged between 0 and 2 events/100 pts-year. The IR for malignant ventricular arrhythmias reached 10.2 events/100 pts-year and 15.6 events/100 pts-year for appropriate implantable cardioverter-defibrillator (ICD) interventions. The IR for advanced conduction disturbances ranged between 3.2 and 7.7 events/100 pts-year. The IR of thromboembolic events reached up to 8.9 events/100 pts-year. Our results strengthen the need for periodic cardiological evaluation focusing on the early recognition of atrial arrhythmias, and possibly for the choice of preventive strategies for thromboembolic events. The frequent need for cardiac pacing due to advanced conduction disturbances should be counterbalanced with the high risk of malignant ventricular arrhythmias that would justify ICD over pacemaker implantation.
PubMed: 35453731
DOI: 10.3390/biology11040530 -
Sensors (Basel, Switzerland) Apr 2022For cardiac defibrillator testing and design purposes, the range and limits of the human TTI is of high interest. Potential influencing factors regarding the electronic... (Review)
Review
For cardiac defibrillator testing and design purposes, the range and limits of the human TTI is of high interest. Potential influencing factors regarding the electronic configurations, the electrode/tissue interface and patient characteristics were identified and analyzed. A literature survey based on 71 selected articles was used to review and assess human TTI and the influencing factors found. The human TTI extended from 12 to 212 Ω in the literature selected. Excluding outliers and pediatric measurements, the mean TTI recordings ranged from 51 to 112 Ω with an average TTI of 76.7 Ω under normal distribution. The wide range of human impedance can be attributed to 12 different influencing factors, including shock waveforms and protocols, coupling devices, electrode size and pressure, electrode position, patient age, gender, body dimensions, respiration and lung volume, blood hemoglobin saturation and different pathologies. The coupling device, electrode size and electrode pressure have the greatest influence on TTI.
Topics: Cardiography, Impedance; Child; Electric Countershock; Electric Impedance; Electrodes; Heart; Humans
PubMed: 35408422
DOI: 10.3390/s22072808 -
Journal of Arrhythmia Apr 2022This meta-analysis aims to evaluate the performance of atrial sensing dipole in single lead implantable cardioverter defibrillator (VDD-ICD) recipients in particular... (Review)
Review
The utilization of atrial sensing dipole in single lead implantable cardioverter defibrillator for detection of new-onset atrial high-rate episodes or subclinical atrial fibrillation: A systematic review and meta-analysis.
This meta-analysis aims to evaluate the performance of atrial sensing dipole in single lead implantable cardioverter defibrillator (VDD-ICD) recipients in particular diagnosing new-onset atrial high-rate episodes (AHREs) defined as rate threshold of 200 beats per minute, or subclinical atrial fibrillation (SCAF) defined as device-detected AF without symptoms. We comprehensively searched PubMed, Embase, and ClinicalTrials.gov. Studies comparing contemporary single- and dual-chamber ICD (VVI-/DDD-ICD) versus VDD-ICD were included. Restricted maximum likelihood method for random effect model and Mantel-Haenszel method for fixed effect model were used to estimate the effect size of new-onset AHREs, or SCAF detection in each group. Three prospective studies were identified and total of 991 participants were included. There were 330 (33.3%) in VDD-ICD and 661 (66.7%) in VVI-/DDD-ICD. Most (78%) participants were men. Median follow-up was from 365 days to 847 days. VDD-ICD has a higher likelihood of detecting AHREs or SCAF as compared to VVI-/DDD-ICD [(OR random effect : 2.6; 95% CI: 1.2, 5.8; = .018); I-squared = 67.8%, = .019]. This difference was more apparently seen in the comparison between VDD-ICD and VVI-ICD [(OR random effect: 3.8; 95% CI: 2.1, 6.6, < .001), I-squared = 0.0%, = .518]. The result is same as fixed effect. Rate of AHREs detection observed in VDD-ICD was not statistically different when compared to the only group with DDD-ICD from SENSE trial. In conclusion, this meta-analysis reveals that the use of floating atrial sensing dipole in VDD-ICD increases the detection of new-onset AHREs or SCAF when compared to VVI-ICD, with similar atrial sensing performance to DDD-ICD.
PubMed: 35387136
DOI: 10.1002/joa3.12675 -
Cardiovascular Digital Health Journal Feb 2022Current implantable cardioverter-defibrillator (ICD) devices are equipped with a device-embedded accelerometer capable of capturing physical activity (PA). In contrast,... (Review)
Review
BACKGROUND
Current implantable cardioverter-defibrillator (ICD) devices are equipped with a device-embedded accelerometer capable of capturing physical activity (PA). In contrast, wearable accelerometer-based methods enable the measurement of physical behavior (PB) that encompasses not only PA but also sleep behavior, sedentary time, and rest-activity patterns.
OBJECTIVE
This systematic review evaluates accelerometer-based methods used in patients carrying an ICD or at high risk of sudden cardiac death.
METHODS
Papers were identified via the OVID MEDLINE and OVID EMBASE databases. PB could be assessed using a wearable accelerometer or an embedded accelerometer in the ICD.
RESULTS
A total of 52 papers were deemed appropriate for this review. Out of these studies, 30 examined device-embedded accelerometry (189,811 patients), 19 examined wearable accelerometry (1601 patients), and 3 validated wearable accelerometry against device-embedded accelerometry (106 patients). The main findings were that a low level of PA after implantation of the ICD and a decline in PA were both associated with an increased risk of mortality, heart failure hospitalization, and appropriate ICD shock. Second, PA was affected by cardiac factors (eg, onset of atrial fibrillation, ICD shocks) and noncardiac factors (eg, seasonal differences, societal factors).
CONCLUSION
This review demonstrated the potential of accelerometer-measured PA as a marker of clinical deterioration and ventricular arrhythmias. Notwithstanding that the evidence of PB assessed using wearable accelerometry was limited, there seems to be potential for accelerometers to improve early warning systems and facilitate preventative and proactive strategies.
PubMed: 35265934
DOI: 10.1016/j.cvdhj.2021.11.006 -
Resuscitation Apr 2022Sudden cardiac arrest survivors with a reversible cause are not eligible for implantable cardioverter defibrillator (ICD) implantation. This study aims to evaluate the... (Review)
Review
Recurrent ventricular arrhythmias and mortality in cardiac arrest survivors with a reversible cause with and without an implantable cardioverter defibrillator: A systematic review.
BACKGROUND
Sudden cardiac arrest survivors with a reversible cause are not eligible for implantable cardioverter defibrillator (ICD) implantation. This study aims to evaluate the risk of recurrent ventricular arrhythmia in sudden cardiac arrest survivors with a reversible cause and evaluate if ICD implantation increases survival.
METHODS
We conducted a systematic review to identify studies evaluating ICD implantation in sudden cardiac arrest survivors with a reversible cause. Outcomes were mortality and appropriate device therapy. Sudden cardiac arrest patients were divided into 4 subgroups: due to acute myocardial infarction; due to coronary artery spasm; due to takotsubo cardiomyopathy; and studies with various reversible causes of cardiac arrest.
RESULTS
27 studies were included, evaluating 11,402 patients. A total of 2570 patients received an ICD. Studies evaluating coronary artery spasm and with various reversible causes showed a relatively high rate of appropriate device therapy (17% and 20%) and described an increased survival in ICD patients. Takotsubo cardiomyopathy was associated with a low mortality and none of the ICD patients received appropriate device therapy. Studies evaluating acute myocardial infarction survivors reported inconsistent results, with high numbers of appropriate device therapy (12-66%), but the mortality-rate of patients with and without an ICD varied.
CONCLUSION
This study shows that the recurrence risk of ventricular arrhythmia varies between different reversible causes of sudden cardiac arrest and should not be evaluated as one entity. Cardiac arrest survivors with a reversible cause can be at risk of recurrent ventricular arrhythmia and selected patients may benefit from ICD implantation.
Topics: Arrhythmias, Cardiac; Death, Sudden, Cardiac; Defibrillators, Implantable; Heart Arrest; Humans; Risk Factors; Survivors; Time Factors; Treatment Outcome
PubMed: 35227821
DOI: 10.1016/j.resuscitation.2022.02.019 -
The International Journal of Angiology... Mar 2022This study aimed to figure out the incidence and predictors of pacemaker-induced cardiomyopathy (PICM) in patients with right ventricular (RV) pacing. We systematically... (Review)
Review
This study aimed to figure out the incidence and predictors of pacemaker-induced cardiomyopathy (PICM) in patients with right ventricular (RV) pacing. We systematically searched in PubMed on March 18, 2020, for English language abstract and full-article journals, using the following criteria: pacemaker induced cardiomyopathy AND right ventricular AND pacemaker AND patients AND human NOT implantable cardioverter defibrillator NOT ICD NOT animal. Four studies were included in this review after filtering 35 studies through year of publication and abstract selection. The average PICM incidence from 1,365 patients included from the four studies was 10.7 to 13.7%. One study stated that preimplantation left ventricular ejection fraction (LVEF) was the predictor for the development of PICM. Three studies mentioned that RV pacing burden was the predictor for the development of PICM. However, the percentage differ in three studies: ≥20, >40, and 60%. In addition, one of the studies also included interventricular dyssynchrony as another predictor. The incidence of PICM in patients with RV pacing ranged from 10.7 to 13.7%. Preimplantation LVEF, interventricular dyssynchrony, and burden of RV pacing are reported as the predictors for the development of PICM in patients with RV pacing.
PubMed: 35221847
DOI: 10.1055/s-0041-1735206 -
Frontiers in Cardiovascular Medicine 2022To evaluate the efficiency of amiodarone in preventing the occurrence of reperfusion ventricular fibrillation (RVF) after aortic cross-clamp (ACC) release in patients...
Effectiveness of Amiodarone in Preventing the Occurrence of Reperfusion Ventricular Fibrillation After the Release of Aortic Cross-Clamp in Open-Heart Surgery Patients: A Meta-Analysis.
OBJECTIVE
To evaluate the efficiency of amiodarone in preventing the occurrence of reperfusion ventricular fibrillation (RVF) after aortic cross-clamp (ACC) release in patients undergoing open-heart surgery.
METHODS
We searched the Web of Science, Cochrane Library, EMBASE, and PubMed databases through January 2021 for relevant studies addressing the efficacy of amiodarone in preventing RVF after ACC release in patients undergoing cardiac surgery. A complete statistical analysis was performed using RevMan 5.3. Risk ratios (RRs) and 95% confidence intervals (CIs) were calculated to express the results of dichotomous outcomes using random or fixed-effect models. The chi-square test and test were used to calculate heterogeneity.
RESULTS
Seven studies (856 enrolled patients; 311 in the amiodarone group, 268 in the lidocaine group, and 277 in the placebo group) were selected for the meta-analysis. The incidence of RVF was significantly decreased in the amiodarone group compared to the placebo group (RR = 0.69, 95%CI: 0.50-0.94, = 0.02). However, amiodarone and lidocaine did not confer any significant difference (RR = 0.98, 95%CI: 0.61-1.59, = 0.94). The percentage of patients requiring electric defibrillation counter shocks (DCSs) did not confer any significant difference between patients administered amiodarone and lidocaine or placebo (RR = 1.58, 95%CI: 0.29-8.74, = 0.60; RR = 0.55, 95%CI: 0.27-1.10, = 0.09; respectively).
CONCLUSIONS
Amiodarone is more effective than a placebo in preventing RVF after ACC release in cardiac surgery. However, the amiodarone group required the same number of electrical DCSs to terminate RVF as the lidocaine or placebo groups.
PubMed: 35187132
DOI: 10.3389/fcvm.2022.821938