European Review For Medical and... May 2024Periimplantitis (PI) is a complex multifactorial chronic disease caused by interactions between bacteria, host immune-inflammatory responses, and genetic or... (Meta-Analysis)
Meta-Analysis
OBJECTIVE
Periimplantitis (PI) is a complex multifactorial chronic disease caused by interactions between bacteria, host immune-inflammatory responses, and genetic or environmental factors that modify buccal eutrophism. In daily clinical practice, an increase in the prevalence of PI (8%) determined the need to establish the PI causes and set optimal therapeutic strategies. The interleukin family (IL-1), a group of cytokines, triggers and perpetuates peri-implantitis. Therefore, they could be used as biomarkers for diagnosis and treatment. This systematic review aimed to analyze the correlation between IL-1 allelic polymorphism (IL-1A -889, IL-1β -511, IL-1β +3954) and the PI disease.
MATERIALS AND METHODS
Selected databases were PubMed, Scopus, and Cochrane Library. The search strategy included the following terms: "dental implants"; "periimplantitis"; "interleukin-IL-1"; "polymorphism"; "perimplant bone loss". Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines were followed. A meta-analysis was conducted on five of 40 review articles. p-values, confidence intervals (CI), and Odds ratios (OR) were assessed. In 4 articles, the p-value was lower than 0.05, confirming the statistical significance of the result.
RESULTS
The prevalence of the selected studies reported the existence of a causal association between polymorphisms of IL-1 and the onset of peri-implantitis, especially for IL-1 allelic variants associated with further polymorphic genes encoding for IL-6, tumor necrosis factor-alpha (TNF-α), matrix metalloproteinases (MMP)-8, IL-1Na, IL-8, IL-18, osteopontin (OPN). In addition, the presence of the IL-1 polymorphism and PI is particularly higher in smokers, diabetes, and autoimmune disease patients.
CONCLUSIONS
The detection of salivary biomarkers is, therefore, a diagnostic tool with a high potential to intercept the PI early and act with appropriate and non-invasive treatment. Due to the continued technological innovation in biomarkers and diagnostic sciences, further studies are needed to investigate the role of these biochemical mediators. The results of studies and the recent technological innovation in biomarkers and diagnostic sciences will allow further research to investigate the role of these biochemical mediators.
Topics: Humans; Peri-Implantitis; Polymorphism, Genetic; Interleukin-1; Dental Implants
PubMed: 38856132
DOI: 10.26355/eurrev_202405_36293 -
Medical Science Monitor : International... Jun 2024Prosthodontics is a dental subspecialty that includes the preparation of dental prosthetics for missing or damaged teeth. It increasingly uses computer-assisted... (Review)
Review
Prosthodontics is a dental subspecialty that includes the preparation of dental prosthetics for missing or damaged teeth. It increasingly uses computer-assisted technologies for planning and preparing dental prosthetics. This study aims to present the findings from a systematic review of publications on artificial intelligence (AI) in prosthodontics to identify current trends and future opportunities. The review question was "What are the applications of AI in prosthodontics and how good is their performance in prosthodontics?" Electronic searching in the Web of Science, ScienceDirect, PubMed, and Cochrane Library was conducted. The search was limited to full text from January 2012 to January 2024. Quadas-2 was used for assessing quality and potential risk of bias for the selected studies. A total of 1925 studies were identified in the initial search. After removing the duplicates and applying exclusion criteria, a total of 30 studies were selected for this review. Results of the Quadas-2 assessment of included studies found that a total of 18.3% of studies were identified as low risk of bias studies, whereas 52.6% and 28.9% of included studies were identified as studies with high and unclear risk of bias, respectively. Although they are still developing, AI models have already shown promise in the areas of dental charting, tooth shade selection, automated restoration design, mapping the preparation finishing line, manufacturing casting optimization, predicting facial changes in patients wearing removable prostheses, and designing removable partial dentures.
Topics: Artificial Intelligence; Humans; Prosthodontics; Dental Prosthesis
PubMed: 38840416
DOI: 10.12659/MSM.944310 -
International Journal of Implant... May 2024The rise of stereolithographic surgical guides and digital workflow, combined with a better knowledge of materials and loading principle, has enabled the placement of... (Review)
Review
PURPOSE
The rise of stereolithographic surgical guides and digital workflow, combined with a better knowledge of materials and loading principle, has enabled the placement of the temporary prosthesis at the time of implant placement. This scoping review aimed to assess the current knowledge available on stackable guides.
METHODS
The review focused on fully edentulous or requiring total edentulism patients. The procedure studied was the use of stackable guides for edentulous patients in order to place immediate temporary prostheses. The clinical endpoint was immediate placement of the provisional prosthesis after surgery combined with a prior bone reduction using a stackable guide.
RESULTS
12 case reports or case series articles met inclusion criteria, which did not allow an analysis by a systematic review. The included studies were case reports or case series. Most of the articles showed a base stabilized by 3 or 4 bone-pins, anchored in buccal or lingual part. Regarding the accuracy of bone reduction (ranged from 0.0248 mm to 1.98 mm) and implant placement when compared to planned, only 4 articles reported quantitative data. 11 articles showed an immediate loading with the transitional prosthesis after implant placement.
CONCLUSIONS
There are as yet no prospective or comparative studies on the efficiency of this technique. In a reliable way, stackable guides seem to be able to guide the practitioner from the flap elevation to the placement of the temporary screw-retained implant supported prosthesis. Given the lack of studies in this specific field of guided surgery, further studies are needed to confirm the clinical relevance of this technique.
Topics: Humans; Dental Implantation, Endosseous; Surgery, Computer-Assisted; Immediate Dental Implant Loading; Mouth, Edentulous
PubMed: 38819752
DOI: 10.1186/s40729-024-00547-w -
Cureus Apr 2024Prosthetic valve endocarditis (PVE) is a rare but serious complication following aortic valve replacement using either a transcatheter aortic valve implantation (TAVI)... (Review)
Review
Clinical Profiles and Outcomes of Prosthesis-Specific Infective Endocarditis Subsequent to Transcatheter Versus Surgical Aortic Valve Replacement: A Systematic Review and Meta-Analysis.
Prosthetic valve endocarditis (PVE) is a rare but serious complication following aortic valve replacement using either a transcatheter aortic valve implantation (TAVI) or surgical aortic valve replacement (SAVR). This study aims to review the profiles and outcomes of PVE after surgical versus transcatheter aortic valve replacement. Electronic searches were performed on Scopus, EMBASE, and PubMed to retrieve related articles. To be included, study designs had to be randomized controlled trials (RCT) or observational cohort studies (in English) with PVE patients that compared differences based on TAVI or SAVR. This review included data for 13,221 patients with PVE diagnoses. Of those, 2,109 patients had an initial SAVR, and 11,112 patients had an initial TAVI. There was no difference in the incidence of PVE in patients who had initial TAVI versus SAVR (1.05% versus 1.01% per person-year, p=0.98). However, the onset of early PVE was more frequently observed in the TAVI group (risk ratio (RR): 1.54, 95% confidence interval (CI) [1.14, 2.08], p=0.005). Patients in the TAVI group had a lower indication for surgery to treat PVE when compared to SAVR (RR: 0.55, 95%CI [0.44, 0.69], p<0.001). was more likely to be the source of PVE in patients who had previous TAVI (RR: 1.34, 95%CI [1.17, 1.54], p<0.001). Also, was more frequently observed as a cause of PVE in the TAVI group (RR: 1.49, 95%CI [1.21, 1.82], p<0.001). Patients who underwent SAVR and TAVI had similar incidences of PVE. However, patients who underwent SAVR had a greater indication for surgery to treat PVE, while those who underwent TAVI had higher comorbidities, a higher likelihood of early PVE, and a trend towards higher one-year mortality.
PubMed: 38817491
DOI: 10.7759/cureus.59398 -
Medicina Oral, Patologia Oral Y Cirugia... Jul 2024We reviewed the literature to examine if the thickness of the sinus membrane is a risk factor for perforation during lateral sinus lift surgery. (Meta-Analysis)
Meta-Analysis
BACKGROUND
We reviewed the literature to examine if the thickness of the sinus membrane is a risk factor for perforation during lateral sinus lift surgery.
MATERIAL AND METHODS
We searched Embase, PubMed, and Web of Science databases till 4th December 2023 for studies examining the risk of perforation with different sinus membrane thicknesses. Studies reporting sinus membrane thickness in perforation and non-perforation cases were also included.
RESULTS
Eleven studies were eligible. All studies used cone beam computed tomography for measuring sinus membrane thickness. Meta-analysis showed that sinus membrane thickness was significantly lower in perforation cases as compared to non-perforation cases (MD: -0.91 95% CI: -1.48, -0.33 I2=94%). Four studies used 2mm as the cut-off to define thick and thin sinus membranes. Pooled analysis failed to demonstrate any significant difference in perforation rates (OR: 0.97 95% CI: 0.44, 2.17 I2=56%). Meta-analysis of studies using 1.5mm (OR: 0.66 95% CI: 0.29, 1.48 I2=72%) and 1mm cut-off (OR: 0.93 95% CI: 0.34, 2.56) also demonstrated similar non-significant results.
CONCLUSIONS
Our study shows that the sinus membrane is significantly thinner in cases with perforations as compared to those with no perforations. However, a meta-analysis based on different membrane thickness cut-offs failed to demonstrate a relationship between thinner sinus membranes and a higher risk of perforation. There is a need for further studies examining the role of sinus membrane thickness on perforation rates.
Topics: Humans; Cone-Beam Computed Tomography; Maxillary Sinus; Risk Factors; Sinus Floor Augmentation; Intraoperative Complications; Dental Implants
PubMed: 38794940
DOI: 10.4317/medoral.26545 -
Journal of Dentistry Jul 2024The study answers the PECO question: "In adults with dental implants (P), do subjects suffering from type-2 diabetes or prediabetes (E) have worse peri-implant... (Meta-Analysis)
Meta-Analysis Review
OBJECTIVE
The study answers the PECO question: "In adults with dental implants (P), do subjects suffering from type-2 diabetes or prediabetes (E) have worse peri-implant conditions (O) than subjects without type-2 diabetes and prediabetes (C)?". Prediabetes (5.7-6.4 % HbA1c), and the different qualities of glycemic control in type-2 diabetes; well-controlled (>8 % HbA1c), and poorly controlled (>8 % HbA1c) individuals; were classified according to the recommendations of the American Diabetes Association.
DATA
Predefined search keys were used with search terms including: Dental implant, diabetes mellitus, glycemic control and HbA1c.
SOURCES
An electronic search in the MEDLINE, Embase, and Cochrane libraries were conducted without any filters or language restrictions. Additionally, manual search of the reference lists were carried out to identify all relevant articles.
STUDY SELECTION
Eligibility criteria were cohort, case-control and cross-sectional studies that answerd our PECO question with at least 1 year of follow-up. From a total of 2660 records, 35 articles (1761 individuals) were included in the analysis. Meta-analytic difference in means for crestal bone loss was 1.2 mm [95 % CI=0.4; 2.1] in patients with prediabetes, 1.8 mm [CI=1.0; 2.7] in poorly controlled patients, whereas 0.4 mm [CI=-0.3; 1.1] in well-controlled individuals. Meta-regression showed that 1 % increase in HbA1c increased crestal bone loss by 0.24 mm.
CONCLUSIONS
Within the limitations of the study, patients with poorly controlled type-2 diabetes or prediabetes may have worse peri-implant conditions compared to patients without diabetes and well-controlled type-2 diabetes. Well-controlled type-2 diabetes is not a risk indicator for peri-implant diseases.
CLINICAL SIGNIFICANCE
Clinicians should measure blood HbA1c levels when planning implant-supported restorations, thus patients with undiagnosed or poorly controlled type-2 diabetes can be identified, that allows for glycemic level adjustment prior to dental implant surgery, ensuring peri-implant health. PROTOCOL REGISTRATION NUMBER: (CRD42022375263).
Topics: Humans; Diabetes Mellitus, Type 2; Prediabetic State; Dental Implants; Glycated Hemoglobin; Risk Factors; Peri-Implantitis; Glycemic Control
PubMed: 38788918
DOI: 10.1016/j.jdent.2024.105094 -
Heliyon May 2024The objective of the systematic review is to find an answer to a question: "What is the influence of the building direction of titanium implants produced by additive... (Review)
Review
The objective of the systematic review is to find an answer to a question: "What is the influence of the building direction of titanium implants produced by additive manufacturing on their physical and mechanical properties?" This review followed the Preferred Reporting Items for Systematic Review and Meta-Analysis (PRISMA 2020) and was registered in the Open Science Framework (OSF) (osf.io/rdc84). Searches were performed in PubMed, Scopus, Science Direct, Embase, and Google Scholar databases on February 17th, 2024. Articles were chosen in 2 steps by 2 blinded reviewers based on previously selected inclusion criteria: In vitro studies that evaluated the influence of the impression direction of titanium implants produced by additive manufacturing on their physical and mechanical properties were selected. Articles were excluded that (1) did not use additive technology to obtain the implants, 2) used surfaces other than titanium, 3) did not evaluate the direction of impression, 4) Studies with only in vivo analyses, clinical studies, systematic reviews, book chapters, short communications, conference abstracts, case reports, and personal opinions.). In the initial search, 581 results were found. Of this total, 108 were excluded for duplication and, after applying the eligibility criteria, 16 articles were included in the present review. The risk of bias was analyzed using the RoBDEMAT. The risk of bias was analyzed using the RoBDEMAT. In addition, the coefficient of interagreement of the reviewers (Cohen's Kappa) and the certainty of evidence by GRADE were analyzed. In general, different impression angles showed variations in the physical and mechanical characteristics of the groups evaluated, including roughness, tensile strength, hardness, and modulus of elasticity. While some impression orientations resulted in greater strength or hardness, others showed greater elasticity or lower surface roughness. These findings suggest that print orientation plays a significant role in determining material properties. It can be concluded that printing directions influence the physical and mechanical properties of titanium implants and the studies included showed that the 0°, 45°, and 90° directions are the most evaluated as they present lower probabilities of structural anisotropies and provide better results in their roughness, hardness, tensile and compressive strength.
PubMed: 38774089
DOI: 10.1016/j.heliyon.2024.e30108 -
The Journal of Prosthetic Dentistry May 2024Additive (3-dimensional printing) and subtractive (milling) methods are digital approaches to fabricating zirconia restorations. Comparisons of their resultant... (Review)
Review
STATEMENT OF PROBLEM
Additive (3-dimensional printing) and subtractive (milling) methods are digital approaches to fabricating zirconia restorations. Comparisons of their resultant fabrication accuracy and restoration fit are lacking.
PURPOSE
The purpose of this systematic review and meta-analysis was to evaluate the accuracy and fit of monolithic zirconia crowns fabricated by 3-dimensional printing and milling.
MATERIAL AND METHODS
The PubMed (Medline), Scopus, Embase, Web of Science, Cochrane Library, and Google Scholar databases were searched up to August 2023. Eligible records were included, and the standardized mean difference (SMD) analyzed 4 outcomes: marginal fit, intaglio fit, trueness, and precision. Publication bias was analyzed with Trim-and-fill, the Egger regression test, and Begg funnel plot. Methodological quality was rated using the QUIN tool.
RESULTS
A total of 15 publications were found eligible out of the initial 6539 records. The 3-dimensional printing group demonstrated a lower marginal fit (SMD=1.46, 95% CI=[0.67, 2.26], P<.001; I=83%, P<.001) and trueness (SMD=0.69, 95% CI=[0.20, 1.18], P=.006; I=88%, P<.001) and a significantly higher precision (SMD=-2.19, 95% CI=[-2.90, -1.48], P<.001; I=56%, P=.045). The intaglio fit did not differ significantly across the study groups (SMD=0.77, 95% CI=[-0.22, 1.77], P=.127; I=87%, P<.001).
CONCLUSIONS
Given the high degree of heterogeneity, it can be cautiously concluded that while 3-dimensional printing led to greater precision, the outcomes of the 2 accuracy and adaptation parameters most crucial to the longevity of the restorations-trueness and marginal fit-showed the superiority of the milling technique.
PubMed: 38772783
DOI: 10.1016/j.prosdent.2024.04.010 -
The British Journal of Oral &... Jun 2024This systematic review aimed to evaluate results reported in the literature regarding the success rate of the titanium mesh technique for the placement of dental... (Review)
Review
This systematic review aimed to evaluate results reported in the literature regarding the success rate of the titanium mesh technique for the placement of dental implants. The topic focused on titanium mesh used as a physical barrier for ridge reconstruction in cases of partial or total edentulism. The authors conducted an electronic search of four databases up to October 2023. Six articles fulfilled the inclusion criteria and were analysed. A total of 100 titanium meshes with a minimum of 4.6 months follow up after surgery were studied, and 241 implants were placed. The review shows that the use of titanium mesh is a predictable method for the rehabilitation of complex atrophic sites. Further investigation generating long-term data is needed to confirm these findings.
Topics: Humans; Titanium; Surgical Mesh; Bone Regeneration; Dental Implantation, Endosseous; Dental Implants; Alveolar Ridge Augmentation; Guided Tissue Regeneration, Periodontal
PubMed: 38760261
DOI: 10.1016/j.bjoms.2024.04.005 -
Journal of Dentistry Jul 2024This systematic review evaluated the occlusal changes after loading with implant-supported single crowns. (Meta-Analysis)
Meta-Analysis Review
OBJECTIVE
This systematic review evaluated the occlusal changes after loading with implant-supported single crowns.
SOURCES
An electronic literature search was conducted in PubMed, Embase and Cochrane library for randomized (RCTs) or non-randomized controlled clinical trials (CCTs), with a minimum of 10 patients.
STUDY SELECTION
Studies reporting the occlusal force changes on implant-supported single crowns - with natural teeth as antagonist - measured at baseline and after loading periods were included. 4 CCTs including 133 ISCs in posterior sites were included for meta-analysis. All analyzed ISCs had no contact at a light bite and a light contact at a heavy bite in MIP at loading (baseline).
DATA
The relative occlusal forces (ROFs) of each implant-supported single crown (ISC) or control tooth (CT) were extracted. ROFs were defined as percentage of the total occlusal force of the entire dentition at maximum intercuspal position (MIP). A meta-analysis was conducted to compare the ROF changes at different follow-up periods and the weighted mean differences in ROF between ISCs and CTs were pooled and analyzed. The amount of change in ROF was significantly lower in 6 to 12 months after loading comparing the follow-up period between baseline and 6 month (p < 0.05). At baseline and 3-month follow-up, CTs presented significant higher ROF than ISCs (p < 0.05), while no significant difference was found after half year following.
CONCLUSIONS
This study showed that the ROF changes significantly over time after loading of ISCs. It might prove that the occlusal concept defined at the time of prosthetic delivery changes or adapts naturally over time.
CLINICAL SIGNIFICANCE
The function of specific implant occlusal concept (no contact at a light bite and a light contact at a heavy bite in MIP) is limited over time and careful monitoring and occlusal adjustments should be recommendable during the first-year follow-up.
Topics: Humans; Crowns; Bite Force; Dental Prosthesis, Implant-Supported; Dental Implants, Single-Tooth; Follow-Up Studies; Dental Occlusion
PubMed: 38734300
DOI: 10.1016/j.jdent.2024.105000