Journal of Indian Prosthodontic Society Jul 2024The present systematic review compares the stability, crestal bone levels and efficacy of osseodensification (OD) drilling techniques for dental implant placement to... (Comparative Study)
Comparative Study
AIM
The present systematic review compares the stability, crestal bone levels and efficacy of osseodensification (OD) drilling techniques for dental implant placement to traditional drilling methods.
SETTINGS AND DESIGN
The Cochrane online library, PubMed, Scopus, and other well-known online resources are used in the research. Using a systematic review design, the current study examines published qualitative studies with an emphasis on analysis.
MATERIALS AND METHODS
Using precise keywords, a thorough search of pertinent databases was carried out in accordance with PRISMA standards. Studies testing dental implant stability, crestal bone levels and clinical results using both OD and traditional procedures were covered by the inclusion criteria.
STATISTICAL ANALYSIS USED
The risk of bias and quality of included studies was assessed using the Newcastle-Ottawa Scale for observational studies and the Cochrane Risk of Bias tool for randomized controlled trials.
RESULTS
A total of 170 patients and 334 implants from Egypt, India, and Brazil were included in eight papers that made up the systematic review. In several clinical situations, osseodensification outperformed standard drilling in terms of implant durability, bone development, and torque data. Statistical analysis presented the lowest risks, while blinded outcome assessment, allocation concealment, random sequence generation, incomplete outcome data and experimental technique revealed higher risks. Bias assessment found various risks across different components.
CONCLUSION
The thorough examination of eight papers demonstrates that osseodensification is a technique with great promise in the field of dental implants. It exhibits superior torque values, bone development, and stability when compared to traditional drilling. The overall results highlight the potential of osseodensification to improve clinical outcomes and advance the science of dental implantology, even in the face of variances in bias concerns.
Topics: Humans; Dental Implants; Dental Implantation, Endosseous; Osseointegration
PubMed: 38946504
DOI: 10.4103/jips.jips_480_23 -
Journal of Indian Prosthodontic Society Jul 2024The aim of this umbrella review was to systematically review the systematic reviews on antagonist enamel wear opposing zirconia crowns compared to other ceramics and...
AIM
The aim of this umbrella review was to systematically review the systematic reviews on antagonist enamel wear opposing zirconia crowns compared to other ceramics and natural enamel.
SETTINGS AND DESIGN
This was an umbrella review following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines.
MATERIALS AND METHODS
An electronic search of PubMed, Cochrane Central, EBSCOhost, and Google Scholar search engines for articles published from January 1, 2013, to January 1, 2023, was conducted using keywords "enamel wear," "zirconia," "feldspathic," "dental ceramics," and "Y-TZP" to identify systematic reviews on antagonist enamel wear opposing zirconia crowns compared to other ceramics and natural enamel.
STATISTICAL ANALYSIS USED
Qualitative analysis.
RESULTS
A total of 86 articles were obtained through electronic search, of which four articles were selected after abstract screening that met the inclusion criteria for evaluating antagonist enamel wear. As compared to feldspathic groups, zirconia had substantially less antagonist wear, while surface polishing exhibited less enamel wear than glazing. Because of the heterogeneity in study design, measurement methods, and outcome variables, a meta-analysis was not possible.
CONCLUSIONS
Over time, the opposing enamel wear caused by polished monolithic zirconia will be either equal to or less than that of natural enamel wear. Polished monolithic zirconia also maintains lower values of enamel wear compared to metal ceramics, feldspathic porcelains, and lithium disilicate.
Topics: Humans; Ceramics; Crowns; Dental Enamel; Tooth Wear; Zirconium
PubMed: 38946503
DOI: 10.4103/jips.jips_32_24 -
Journal of Orthopaedic Surgery and... Jun 2024To compare the efficacy and safety of cortical bone trajectory (CBT) screw and pedicle screw (PS) internal fixation in the treatment of adjacent segment degeneration... (Meta-Analysis)
Meta-Analysis Comparative Study
Comparative effectiveness of cortical bone trajectory screws and pedicle screws in the treatment of adjacent segment degeneration after lumbar fusion surgery: a systematic review and meta-analysis.
PURPOSE
To compare the efficacy and safety of cortical bone trajectory (CBT) screw and pedicle screw (PS) internal fixation in the treatment of adjacent segment degeneration (ASD) after lumbar fusion.
METHODS
This study was registered on International Prospective Register of Systematic Reviews (PROSPERO) (ID: CRD42023484937). We searched PubMed, Embase, Web of Science, Cochrane Library, China National Knowledge Infrastructure (CNKI), Wan Fang Database, and Wei Pu Database by computer to collect controlled clinical studies on the efficacy and safety of cortical bone trajectory (CBT) screw and pedicle screw (PS) internal fixation in the treatment of adjacent segment degeneration (ASD) after lumbar fusion from database establishment to November 2023. Two researchers screened the literature, extracted data and evaluated the risk of bias of the included studies, recorded the authors, and sample size, and extracted the intraoperative blood loss, operation time, Oswestry disability index (ODI), Visual analogue scale (VAS), disc height (DH), hospital length stay and complications in each study. Meta-analysis was performed using Revman 5.4 software provided by Cochrane Library.
RESULTS
A total of 6 cohort studies (CS) and 1 randomized controlled study with a total of 420 patients were included in this study, including 188 patients in the CBT group and 232 patients in the PS group. The CBT group had lower intraoperative blood loss than the PS group [mean difference (MD) = -129.38, 95% CI (-177.22, -81.55), P < 0.00001] and operation time was shorter than that of the PS group [MD = -1.42, 95% CI (-2.63, -0.20), P = 0.02]. Early postoperative back and leg pain improved more significantly in the CBT group [MD = -0.77, 95% CI (-1.35, -0.19), P = 0.01; MD = -0.24, 95% CI (-0.37, -0.10), P = 0.0005].
CONCLUSION
Compared with PS, CBT for adjacent segment degeneration after lumbar fusion has the advantages of less intraoperative blood loss, shorter operation time, and less back and leg pain in the early postoperative period.
Topics: Humans; Spinal Fusion; Pedicle Screws; Cortical Bone; Lumbar Vertebrae; Treatment Outcome; Intervertebral Disc Degeneration; Bone Screws; Operative Time; Male; Female; Blood Loss, Surgical
PubMed: 38943143
DOI: 10.1186/s13018-024-04865-y -
BMC Oral Health Jun 2024The desirable properties of silver diamine fluoride (SDF) make it an effective agent for managing dental caries and tooth hypersensitivity. There are several clinical...
BACKGROUND
The desirable properties of silver diamine fluoride (SDF) make it an effective agent for managing dental caries and tooth hypersensitivity. There are several clinical instances that SDF application might precede the placement of direct tooth-colored restorations. On the other hand, SDF stains demineralized/carious dental tissues black, which might affect the esthetic outcomes of such restorations. Color is a key parameter of esthetics in dentistry. Therefore, this study aims to systematically review dental literature on color/color change of tooth-colored restorations placed following the application of SDF on dentine.
METHODS
Comprehensive search of PubMed, Embase, Scopus and ISI Web of Science databases (until August 2023) as well as reference lists of retrieved studies was performed. In vitro studies reported color or color change of tooth-colored restorative materials applied on SDF-treated dentine were included. Methodological quality assessment was performed using RoBDEMAT tool. Pooled weighted mean difference (WMD) and 95% confidence interval (95% CI) was calculated.
RESULTS
Eleven studies/reports with a total of 394 tooth-colored restorations placed following a) no SDF (control) or b) SDF with/without potassium iodide (KI)/glutathione dentine pre-treatments were included. Color change was quantified using ∆E formulas in most reports. The pooled findings for the comparison of resin-based composite (RBC) restorations with and without prior 38% SDF + KI application revealed no statistically significant differences in ∆E values at short- and long-term evaluations (~ 14 days: WMD: -0.56, 95% CI: -2.09 to 0.96; I: 89.6%, and ~ 60 days: WMD: 0.11; 95% CI: -1.51 to 1.72; I: 76.9%). No studies provided sufficient information for all the items in the risk of bias tool (moderate to low quality).
CONCLUSIONS
The limited evidence suggested comparable color changes of RBC restorations with and without 38% SDF + KI pre-treatment up to 60 days. The included studies lacked uniformity in methodology and reported outcomes. Further studies are imperative to draw more definite conclusions.
PROTOCOL REGISTRATION
The protocol of this systematic review was registered in PROSPERO database under number CRD42023485083.
Topics: Silver Compounds; Humans; Quaternary Ammonium Compounds; Fluorides, Topical; Dentin; Color; Dental Restoration, Permanent
PubMed: 38937760
DOI: 10.1186/s12903-024-04487-0 -
PloS One 2024The elderly is commonly susceptible to depression, the symptoms for which may overlap with natural aging or other illnesses, and therefore miss being captured by routine...
BACKGROUND
The elderly is commonly susceptible to depression, the symptoms for which may overlap with natural aging or other illnesses, and therefore miss being captured by routine screening questionnaires. Passive sensing data have been promoted as a tool for depressive symptoms detection though there is still limited evidence on its usage in the elderly. Therefore, this study aims to review current knowledge on the use of passive sensing data via smartphones and smartwatches in depressive symptom screening for the elderly.
METHOD
The search of literature was performed in PubMed, IEEE Xplore digital library, and PsycINFO. Literature investigating the use of passive sensing data to screen, monitor, and/or predict depressive symptoms in the elderly (aged 60 and above) via smartphones and/or wrist-worn wearables was included for initial screening. Studies in English from international journals published between January 2012 to September 2022 were included. The reviewed studies were further analyzed by a narrative analysis.
RESULTS
The majority of 21 included studies were conducted in Western countries with a few in Asia and Australia. Most studies adopted a cohort study design (n = 12), followed by cross-sectional design (n = 7) and a case-control design (n = 2). The most popular passive sensing data was related to sleep and physical activity using an actigraphy. Sleep characteristics, such as prolonged wakefulness after sleep onset, along with lower levels of physical activity, exhibited a significant association with depression. However, cohort studies expressed concerns regarding data quality stemming from incomplete follow-up and potential confounding effects.
CONCLUSION
Passive sensing data, such as sleep, and physical activity parameters should be promoted for depressive symptoms detection. However, the validity, reliability, feasibility, and privacy concerns still need further exploration.
Topics: Humans; Smartphone; Depression; Aged; Mass Screening; Wearable Electronic Devices; Sleep; Middle Aged; Exercise; Female
PubMed: 38935797
DOI: 10.1371/journal.pone.0304845 -
Archivio Italiano Di Urologia,... Jun 2024Erectile dysfunction can cause self-withdrawal and decreased quality of life. Patients who do not respond to pharmacological therapy and other conservative treatments... (Comparative Study)
Comparative Study Meta-Analysis
INTRODUCTION
Erectile dysfunction can cause self-withdrawal and decreased quality of life. Patients who do not respond to pharmacological therapy and other conservative treatments are urged to undergo penile prosthesis implantation. Malleable penile prosthesis was the first prosthesis developed, but then inflatable penile prosthesis was developed to give a more natural erection. There is no meta-analysis comparing inflatable and malleable penile prostheses in terms of safety and efficacy. This study is conducted to evaluate patient and partner satisfaction, ease of use, mechanical failure, and infection rate in patients who underwent penile prosthesis implantation.
METHOD
This meta-analysis followed Preferred Reporting Items for Systematic Review and Meta-analysis (PRISMA) protocols. Five eligible studies were included from Pubmed, Scopus, ScienceDirect, and SemanticScholar databases.
RESULT
In this study, patient and partner satisfaction are significantly better (OR 3.39, 95% CI 1.66-6.93, p = 0.0008) (OR 2.32, 95% CI 1.75-3.08, p < 0.00001). Mechanical failure is also significantly higher in inflatable penile prostheses (OR 5.60, 95% CI 2.02-15.53, p = 0.0009). There is no significant difference in terms of ease of use and infection rate in inflatable or malleable penile prostheses.
CONCLUSIONS
This study concluded that inflatable penile prosthesis is better in terms of patient and partner satisfaction, but mechanical failures occur more frequently in this type of prosthesis.
Topics: Humans; Male; Erectile Dysfunction; Penile Prosthesis; Patient Satisfaction; Prosthesis Design; Penile Implantation; Treatment Outcome; Quality of Life; Prosthesis Failure
PubMed: 38934528
DOI: 10.4081/aiua.2024.12353 -
Nutrients Jun 2024Handgrip strength (HGS) is an indicator of muscular strength, used in the diagnosis of sarcopenia, undernutrition, and physical frailty as well as recovery. Typically,... (Review)
Review
BACKGROUND
Handgrip strength (HGS) is an indicator of muscular strength, used in the diagnosis of sarcopenia, undernutrition, and physical frailty as well as recovery. Typically, the maximum HGS value is used; however, recent evidence suggests the exploration of new indicators provided based on the force-time curve to achieve a more comprehensive assessment of muscle function. Therefore, the objective was to identify indicators of the HGS profile beyond maximum HGS, based on force-time curves, and to systematize knowledge about their applications to various types of samples, health issues, and physical performance.
METHODS
A systematic review was performed including studies whose participants' HGS was assessed with a digital or adapted dynamometer. The outcome measures were HGS profile indicators calculated from the force-time curve.
RESULTS
a total of 15 studies were included, and the following indicators were identified: grip fatigue, fatigability index, fatigue rate, fatigue resistance, time to 80% maximal voluntary contraction, plateau coefficient of variability, time to maximum value, T-90%, release rate, power factor, grip work, average integrated area, endurance, cycle duration, time between cycles, maximum and minimum force-velocity, rate of grip force, final force, inflection point, integrated area, submaximal control, and response time.
CONCLUSIONS
Various indicators based on the force-time curve can be assessed through digital or adapted dynamometers. Future research should analyze these indicators to understand their implications for muscle function assessment, to standardize evaluation procedures, to identify clinically relevant measures, and to clarify their implications in clinical practice.
Topics: Humans; Hand Strength; Muscle Strength Dynamometer; Female; Male; Muscle Fatigue; Aged; Muscle, Skeletal; Muscle Strength; Middle Aged; Sarcopenia; Time Factors; Adult
PubMed: 38931305
DOI: 10.3390/nu16121951 -
Medicina (Kaunas, Lithuania) May 2024: The present systematic review and meta-analysis were conducted to evaluate and compare the long-term clinical outcomes of immediate implants placed into fresh sockets... (Meta-Analysis)
Meta-Analysis Comparative Study Review
: The present systematic review and meta-analysis were conducted to evaluate and compare the long-term clinical outcomes of immediate implants placed into fresh sockets with and without periapical pathology. : After the search and review of the literature in the electronic databases, 109 publications were achieved. The titles and abstracts of 66 publications were screened. After the evaluation of the full text of 22 publications, based on the inclusion criteria, six controlled clinical studies were included in this systematic review and meta-analysis. The statistical calculation showed no heterogeneity among the studies included. The implant survival was 99.6% in the test (socket with periapical pathology) and control (socket without periapical pathology) groups of all the clinical trials. The results of the meta-analysis showed no statistically significant difference between test and control groups regarding the marginal bone level and the width of keratinized mucosa in all the studies. Other parameters indicating plaque level, bleeding on probing, and gingival recession also did not differ between test and control groups at the final follow-up in nearly all studies. : Within the limitation of this systemic review and meta-analysis, the obtained data suggest that implants immediately placed into the extraction sockets of teeth exhibiting periapical pathology can be successfully osseointegrated for an extended period.
Topics: Humans; Tooth Socket; Dental Implantation, Endosseous; Dental Implants; Immediate Dental Implant Loading
PubMed: 38929509
DOI: 10.3390/medicina60060893 -
Medicina (Kaunas, Lithuania) May 2024: The European Association of Urology guidelines on urolithiasis highlight the limited evidence supporting the superiority of percutaneous nephrostomy (PCN) over... (Meta-Analysis)
Meta-Analysis
: The European Association of Urology guidelines on urolithiasis highlight the limited evidence supporting the superiority of percutaneous nephrostomy (PCN) over retrograde ureteral stent placement for the primary treatment of infected hydronephrosis secondary to urolithiasis. We, therefore, conducted a systematic review and meta-analysis comparing the effects of PCN and retrograde ureteral stent in patients with severe urinary tract infections secondary to obstructive urolithiasis. : Meta-analyses were performed to compare four outcomes: time for the temperature to return to normal; time for the white blood cell (WBC) count to return to normal; hospital length of stay; and procedure success rate. After a full-text review, eight studies were identified as relevant and included in our systematic review and meta-analysis. : No significant difference was detected between PCN and retrograde ureteral stenting for the time for the temperature to return to normal ( = 0.13; mean difference [MD] = -0.74; 95% confidence interval [CI] = -1.69, 0.21; I = 96%) or the time for the WBC count to return to normal ( = 0.24; MD = 0.46; 95% CI = -0.30, 1.21; I = 85%). There was also no significant difference between methods for hospital length of stay ( = 0.78; MD = 0.45; 95% CI = -2.78, 3.68; I = 96%) or procedure success rate ( = 0.76; odds ratio = 0.86; 95% CI = 0.34, 2.20; I = 47%). : The clinical outcomes related to efficacy did not differ between PCN and retrograde ureteral stenting for severe urinary tract infection with obstructive urolithiasis. Thus, the choice between procedures depends mainly on the urologist's or patient's preferences.
Topics: Humans; Stents; Urinary Tract Infections; Urolithiasis; Nephrostomy, Percutaneous; Length of Stay; Treatment Outcome; Male
PubMed: 38929478
DOI: 10.3390/medicina60060861 -
Medicina (Kaunas, Lithuania) May 2024Muscle properties are critical for performance and injury risk, with changes occurring due to physical exertion, aging, and neurological conditions. The MyotonPro... (Review)
Review
Muscle properties are critical for performance and injury risk, with changes occurring due to physical exertion, aging, and neurological conditions. The MyotonPro device offers a non-invasive method to comprehensively assess muscle biomechanical properties. This systematic review evaluates the reliability of MyotonPro across various muscles for diagnostic purposes. Following PRISMA guidelines, a comprehensive literature search was conducted in Medline (PubMed), Ovid (Med), Epistemonikos, Embase, Cochrane Library, Clinical trials.gov, and the WHO International Clinical Trials platform. Studies assessing the reliability of MyotonPro across different muscles were included. A methodological quality assessment was performed using established tools, and reviewers independently conducted data extraction. Statistical analysis involved summarizing intra-rater and inter-rater reliability measures across muscles. A total of 48 studies assessing 31 muscles were included in the systematic review. The intra-rater and inter-rater reliability were consistently high for parameters such as frequency and stiffness in muscles of the lower and upper extremities, as well as other muscle groups. Despite methodological heterogeneity and limited data on specific parameters, MyotonPro demonstrated promising reliability for diagnostic purposes across diverse patient populations. The findings suggest the potential of MyotonPro in clinical assessments for accurate diagnosis, treatment planning, and monitoring of muscle properties. Further research is needed to address limitations and enhance the applicability of MyotonPro in clinical practice. Reliable muscle assessments are crucial for optimizing treatment outcomes and improving patient care in various healthcare settings.
Topics: Humans; Reproducibility of Results; Muscle, Skeletal; Diagnostic Tests, Routine
PubMed: 38929468
DOI: 10.3390/medicina60060851