Entropy (Basel, Switzerland) May 2018Asthma is a chronic respiratory disease featured with unpredictable flare-ups, for which continuous lung function monitoring is the key for symptoms control. To find new... (Review)
Review
Asthma is a chronic respiratory disease featured with unpredictable flare-ups, for which continuous lung function monitoring is the key for symptoms control. To find new indices to individually classify severity and predict disease prognosis, continuous physiological data collected from monitoring devices is being studied from different perspectives. Entropy, as an analysis method for quantifying the inner irregularity of data, has been widely applied in physiological signals. However, based on our knowledge, there is no such study to summarize the complexity differences of various physiological signals in asthmatic patients. Therefore, we organized a systematic review to summarize the complexity differences of important signals in patients with asthma. We searched several medical databases and systematically reviewed existing asthma clinical trials in which entropy changes in physiological signals were studied. As a conclusion, we find that, for airflow, heart rate variability, center of pressure and respiratory impedance, their entropy values decrease significantly in asthma patients compared to those of healthy people, while, for respiratory sound and airway resistance, their entropy values increase along with the progression of asthma. Entropy of some signals, such as respiratory inter-breath interval, shows strong potential as novel indices of asthma severity. These results will give valuable guidance for the utilization of entropy in physiological signals. Furthermore, these results should promote the development of management and diagnosis of asthma using continuous monitoring data in the future.
PubMed: 33265493
DOI: 10.3390/e20060402 -
Medicine Dec 2017The trigeminocardiac reflex (TCR) is defined as sudden onset of parasympathetic dysrhythmias including hemodynamic irregularities, apnea, and gastric hypermotility... (Meta-Analysis)
Meta-Analysis Review
BACKGROUND
The trigeminocardiac reflex (TCR) is defined as sudden onset of parasympathetic dysrhythmias including hemodynamic irregularities, apnea, and gastric hypermotility during stimulation of sensory branches of the trigeminal nerve. Since the first description of the TCR 1999, there is an ongoing discussion about a more flexible than the existing clinical definition. Aim of this work was to create a clinical surrogate definition through a systematic review of the literature.
METHODS
In this meta-analysis study, literature about TCR occurrences was, according to the Preferred Reporting Items for Systematic Reviews and Meta-Analysis statement, systematically identified through various search engines including PubMed (Medline), Embase (Ovid SP), and ISI Web of Sciences databases from January 2005 to August 2015. TCR was defined as a drop of heart rate (HR) below 60 bpm or 20% to the baseline. We extracted detailed data about hemodynamic changes and searched for connections between arterial blood pressure (BP) and HR changes during such episodes.
RESULTS
Overall 45 studies harboring 57 patients were included in the study but only 32 patients showed sufficient data for final analyze. HR showed a nonlinear behavior with a "tipping point" phenomena that differs in variance from the central/peripheral (20-30% drop) to ganglion (40-49% drop). BP showed a linear behavior with a "central limit" phenomena not differing in variance in the whole subgroup (30-39% drop). An analyzation of the correlation between BP and HR showed a trend to a linear correlation.
CONCLUSIONS
We can show for the first time that HR is the dominant variable in the TCR and present a new surrogate definition model. This model and the role of BP must be better investigated in further studies.
Topics: Adolescent; Adult; Aged; Analysis of Variance; Arterial Pressure; Child; Child, Preschool; Female; Heart Rate; Humans; Male; Middle Aged; Models, Theoretical; Reflex, Trigeminocardiac; Young Adult
PubMed: 29245296
DOI: 10.1097/MD.0000000000009033 -
The Cochrane Database of Systematic... Nov 2017Polycystic ovary syndrome (PCOS) is a common endocrine condition, affecting approximately one in 10 women. PCOS is defined by two of three features: oligo- or... (Meta-Analysis)
Meta-Analysis Review
BACKGROUND
Polycystic ovary syndrome (PCOS) is a common endocrine condition, affecting approximately one in 10 women. PCOS is defined by two of three features: oligo- or anovulation, clinical or biochemical hyperandrogenism or both, or polycystic ovaries.Women with PCOS can have a wide range of health problems, including infrequent and irregular periods, unwanted hair growth and acne, and subnormal fertility. Long-term health concerns include an increased risk of heart disease, diabetes and the development of precancerous disease of the womb.
OBJECTIVES
To assess the effectiveness and harms of ovarian surgery as a treatment for symptomatic relief of hirsutism, acne and menstrual irregularity in PCOS.
SEARCH METHODS
We searched the Cochrane Gynaecology and Fertility Group specialized register, CENTRAL, MEDLINE, Embase and PsycINFO (from inception to 17 October 2016). We handsearched citation lists, registers of ongoing trials and conference proceedings.
SELECTION CRITERIA
We included randomized controlled trials (RCTs) of women undergoing ovarian drilling in comparison to no treatment, medical treatment, or other forms of surgical treatment for the symptoms of PCOS.
DATA COLLECTION AND ANALYSIS
We used standard methodological procedures recommended by Cochrane. The primary outcome measures were improvement in menstrual regularity and androgenic symptoms of PCOS (hirsutism, acne); the secondary outcome measures included harms, change of body mass index (BMI), waist circumference, androgen levels, metabolic measures and quality of life. We assessed the quality of the evidence using GRADE methods.
MAIN RESULTS
We included 22 RCTs (2278 women analyzed) of participants with PCOS and symptoms of acne, hirsutism or irregular menstrual cycles, all of which included laparoscopic ovarian drilling (LOD) as an intervention.Two studies reported their funding source (Farquhar 2002 - supported in part by the Auckland Medical Research Foundation; Sarouri 2015 - the authors thank the Vice Chancellor for Research of Guilan University of Medical Sciences for funding this project).The quality of the evidence ranged from very low to moderate quality. The main limitations were imprecision associated with the low number of studies, inconsistency and risk of bias associated with the inability to blind participants. There were too few studies to assess risk of publication bias. Menstrual RegularityTwo studies compared LOD versus metformin (n=226) but no conclusions could be drawn with regard to menstrual regularity, as their findings were inconsistent and they were unsuitable for pooling. There appeared to be little or no difference in the rate of women reporting improvement in menstrual regularity when LOD was compared with medical treatment including metformin + clomiphene (OR 1.02, 95% CI 0.64 to 1.64, 2 studies, 332 women, I = 13%, low-quality evidence), letrozole (OR 1.08, 95% CI 0.64 to 1.84, 1 study, 260 women, low-quality evidence), or metformin + letrozole (OR 0.95, 95% CI 0.49 to 1.81, 1 study, 146 women, low-quality evidence). However, one study reported that LOD was superior to gonadotrophin (OR 19.2, 95% CI 3.17 to 116.45, 1 study, 35 women, very low-quality evidence).There appeared to be little or no difference in the rate of women reporting improvement in menstrual regularity when bilateral unipolar LOD was compared to unilateral LOD (OR 1.51, 95% CI 0.62 to 3.71, 2 studies, 104 women, I = 0%, moderate-quality evidence), transvaginal ultrasound-guided LOD (OR 1.23, 95% CI 0.64 to 2.37, 1 study, 147 women, low-quality evidence), LOD using adjusted thermal dose in accordance with the ovarian volume (OR 0.42, 95% CI 0.16 to 1.14, 1 study, 115 women, low-quality evidence) or bipolar LOD (OR 1.00, 95% CI 0.05 to 18.57, 1 study, 18 women, low-quality evidence).Four to five punctures per ovary may improve the rate of women reporting menstrual regularity compared with two or fewer (OR 16.04, 95% CI 4.19 to 61.34, 2 studies, 73 women, I = 0%, low-quality evidence). Androgenic SymptomsThere was probably little or no difference in improvement in androgenic symptoms when LOD was compared to metformin (OR 1.00, 95% CI 0.42 to 2.37, 1 study, 126 women, moderate-quality evidence) or gonadotrophins; acne (OR 3.20, 95% CI 0.33 to 30.94, 1 study, 25 women, low-quality evidence), hirsutism (OR 2.31, 95% CI 0.22 to 23.89, 1 study, 25 women, low-quality evidence).There appeared to be little or no difference in improvement of androgenic symptoms when LOD was compared to transvaginal ultrasound-guided LOD, with respect to hirsutism (OR 1.09, 95% CI 0.30 to 3.91, 1 study, 39 women, low-quality evidence) or acne (OR 0.84, 95% CI 0.20 to 3.50, 1 study, 31 women, low-quality evidence). HarmsLOD was associated with fewer gastrointestinal side effects than metformin plus clomiphene (OR 0.05, 95% CI 0.01 to 0.36, 2 studies, 332 women, I = 0%, moderate-quality evidence). One study suggested little or no difference in rates of ovarian hyperstimulation syndrome between LOD and gonadotrophins (OR 0.08, 95% CI 0.00 to 1.61, 1 study, 33 women, low-quality evidence).There were fewer adhesions with transvaginal hydrolaparoscopy compared to LOD (OR 0.10, 95% CI 0.05 to 0.18, 1 study, 246 women, moderate-quality evidence). There appeared to be little or no difference in adhesions when variable energy LOD was compared with standard LOD (OR 0.96, 95% CI 0.32 to 2.88, 1 study, 64 women, low-quality evidence). Another study (44 women) reported that none of the women who returned for surgery following either traditional or unilateral LOD were found to have adhesions.
AUTHORS' CONCLUSIONS
There was no clear evidence that LOD improves menstrual regularity or the androgenic symptoms of PCOS, compared to most of the medical treatments used in the included studies. LOD was associated with fewer gastrointestinal side effects compared to metformin and clomiphene.There was also no clear evidence of different effectiveness between types of LOD, except that LOD with four to five punctures per ovary may be more effective than two or fewer punctures. There was little evidence comparing LOD with different types of surgery, although one study concluded that transvaginal hydrolaparoscopy had a lower risk of adhesions than LOD.There was evidence from one small study of benefit from LOD compared to gonadotrophins for menstrual regulation. However, gonadotrophins are seldom used for this indication.
Topics: Acne Vulgaris; Clomiphene; Female; Gonadotropins; Hirsutism; Humans; Laparoscopy; Letrozole; Menstruation Disturbances; Metformin; Nitriles; Ovary; Polycystic Ovary Syndrome; Punctures; Randomized Controlled Trials as Topic; Triazoles
PubMed: 29125183
DOI: 10.1002/14651858.CD009526.pub2 -
The Cochrane Database of Systematic... Jun 2016Atrial fibrillation (AF), the most common arrhythmia in clinical practice, is a leading cause of morbidity and mortality. Screening for AF in asymptomatic patients has... (Review)
Review
BACKGROUND
Atrial fibrillation (AF), the most common arrhythmia in clinical practice, is a leading cause of morbidity and mortality. Screening for AF in asymptomatic patients has been proposed as a way of reducing the burden of the disease by detecting people who would benefit from prophylactic anticoagulation therapy before the onset of symptoms. However, for screening to be an effective intervention, it must improve the detection of AF and provide benefit for those detected earlier as a result of screening.
OBJECTIVES
This review aims to answer the following questions.Does systematic screening increase the detection of AF compared with routine practice? Which combination of screening population, strategy and test is most effective for detecting AF compared with routine practice? What safety issues and adverse events may be associated with individual screening programmes? How acceptable is the intervention to the target population? What costs are associated with systematic screening for AF?
SEARCH METHODS
We searched the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE (Ovid) and EMBASE (Ovid) up to 11 November 2015. We searched other relevant research databases, trials registries and websites up to December 2015. We also searched reference lists of identified studies for potentially relevant studies, and we contacted corresponding authors for information about additional published or unpublished studies that may be relevant. We applied no language restrictions.
SELECTION CRITERIA
Randomised controlled trials comparing screening for AF with routine practice in people 40 years of age and older were eligible. Two review authors (PM and CT) independently selected trials for inclusion.
DATA COLLECTION AND ANALYSIS
Two review authors (PM and CT) independently assessed risk of bias and extracted data. We used odds ratios (ORs) and 95% confidence intervals (CIs) to present results for the primary outcome, which is a dichotomous variable. As we identified only one study for inclusion, we performed no meta-analysis. We used the GRADE (Grades of Recommendation, Assessment, Development and Evaluation Working Group) method to assess the quality of the evidence and GRADEPro to create a 'Summary of findings' table.
MAIN RESULTS
One cluster-randomised controlled trial met the inclusion criteria for this review. This study compared systematic screening (by invitation to have an electrocardiogram (ECG)) and opportunistic screening (pulse palpation during a general practitioner (GP) consultation for any reason, followed by an ECG if pulse was irregular) versus routine practice (normal case finding on the basis of clinical presentation) in people 65 years of age or older.Results show that both systematic screening and opportunistic screening of people over 65 years of age are more effective than routine practice (OR 1.57, 95% CI 1.08 to 2.26; and OR 1.58, 95% CI 1.10 to 2.29, respectively; both moderate-quality evidence). We found no difference in the effectiveness of systematic screening and opportunistic screening (OR 0.99, 95% CI 0.72 to 1.37; low-quality evidence). A subgroup analysis found that systematic screening and opportunistic screening were more effective in men (OR 2.68, 95% CI 1.51 to 4.76; and OR 2.33, 95% CI 1.29 to 4.19, respectively) than in women (OR 0.98, 95% CI 0.59 to 1.62; and OR 1.2, 95% CI 0.74 to 1.93, respectively). No adverse events associated with screening were reported.The incremental cost per additional case detected by opportunistic screening was GBP 337, compared with GBP 1514 for systematic screening. All cost estimates were based on data from the single included trial, which was conducted in the UK between 2001 and 2003.
AUTHORS' CONCLUSIONS
Evidence suggests that systematic screening and opportunistic screening for AF increase the rate of detection of new cases compared with routine practice. Although these approaches have comparable effects on the overall AF diagnosis rate, the cost of systematic screening is significantly greater than the cost of opportunistic screening from the perspective of the health service provider. Few studies have investigated effects of screening in other health systems and in younger age groups; therefore, caution needs to be exercised in relation to transferability of these results beyond the setting and population in which the included study was conducted.Additional research is needed to examine the effectiveness of alternative screening strategies and to investigate the effects of the intervention on risk of stroke for screened versus non-screened populations.
Topics: Aged; Asymptomatic Diseases; Atrial Fibrillation; Electrocardiography; Female; Humans; Male; Mass Screening; Palpation; Pulse; Randomized Controlled Trials as Topic
PubMed: 27258214
DOI: 10.1002/14651858.CD009586.pub3 -
The Cochrane Database of Systematic... Nov 2015Accelerating the rate of tooth movement may help to reduce the duration of orthodontic treatment and associated unwanted effects including root resorption and enamel... (Review)
Review
BACKGROUND
Accelerating the rate of tooth movement may help to reduce the duration of orthodontic treatment and associated unwanted effects including root resorption and enamel demineralisation. Several methods, including surgical and non-surgical adjuncts, have been advocated to accelerate the rate of tooth movement. Non-surgical techniques include low-intensity laser irradiation, resonance vibration, pulsed electromagnetic fields, electrical currents and pharmacological approaches.
OBJECTIVES
To assess the effect of non-surgical adjunctive interventions on the rate of orthodontic tooth movement and the overall duration of treatment.
SEARCH METHODS
We searched the following databases on 25 November 2014: the Cochrane Oral Health Group's Trials Register (November 2014), the Cochrane Central Register of Controlled Trials (CENTRAL; The Cochrane Library 2014, Issue 10), MEDLINE via OVID (1946 to November 2014), EMBASE via OVID (1980 to November 2014), LILACS via BIREME (1980 to November 2014), metaRegister of Controlled Trials (November 2014), the US National Institutes of Health Trials Register (ClinicalTrials.gov; November 2014) and the WHO International Clinical Trials Registry Platform (November 2014). We checked the reference lists of all trials identified for further studies. There were no restrictions regarding language or date of publication in the searches of the electronic databases.
SELECTION CRITERIA
We included randomised controlled trials (RCTs) of people receiving orthodontic treatment using fixed appliances along with non-surgical adjunctive interventions to accelerate tooth movement. We excluded non-parallel design studies (for example, split-mouth) as we regarded them as inappropriate for assessment of the effects of this type of intervention.
DATA COLLECTION AND ANALYSIS
Two review authors were responsible for study selection, risk of bias assessment and data extraction; they carried out these tasks independently. Any disagreements were resolved by discussion amongst the review team to reach consensus. The review authors contacted the corresponding authors of trials to obtain missing information and data to allow calculation of mean differences (MD), 95% confidence intervals (CI) or risk ratios (RR) when these were not reported.
MAIN RESULTS
We included two studies in this review, which were both assessed as being at high risk of bias. The two studies, involving a total of 111 participants, compared the use of Tooth Masseuse and OrthoAccel with conventional treatment mechanics during orthodontic alignment and canine retraction phases, respectively. Both studies included objective assessment of the amount or rate of tooth movement, but we were not able to meta-analyse this data as they used different outcome measurements at different stages of the orthodontic treatment process. One study measured subjective evaluation of pain and discomfort and the other evaluated adverse effects. The studies did not directly report either the duration of orthodontic treatment or the number of visits during active treatment.Using the Tooth Masseuse with 111 Hz at 0.06 Newtons (N) for 20 minutes daily resulted in greater reduction in irregularity in the lower incisor region over 10 weeks, assessed using Little's Irregularity Index (LII) with a mean difference (MD) of 0.6 mm (95% confidence interval (CI) -0.94 to 2.34) when compared to the control group. Pain and discomfort increased at six to eight hours after arch wire placement and after seven days, with minimal difference between the intervention and control groups. No statistical tests were provided for either variable and the differences between the two groups were not clinically important.Using OrthoAccel with 30 Hz at 0.25 N for 20 minutes daily produced a higher rate of maxillary canine distalisation in comparison to the control group (MD 0.37 mm/month; 95% CI -0.07 to 0.81; P = 0.05). Whilst this difference suggested 50% faster tooth movement using the vibrational appliance, the absolute differences were marginal and deemed clinically unimportant. Similar levels of non-serious adverse effects were reported in the intervention and control groups with a risk ratio of 0.96 (95% CI 0.32 to 2.85).Overall, the quality of the evidence was very low and therefore we cannot rely on the findings.
AUTHORS' CONCLUSIONS
There is very little clinical research concerning the effectiveness of non-surgical interventions to accelerate orthodontic treatment. The available evidence is of very low quality and so it is not possible to determine if there is a positive effect of non-surgical adjunctive interventions to accelerate tooth movement. Although there have been claims that there may be a positive effect of light vibrational forces, results of the current studies do not reach either statistical or clinical significance. Further well-designed and rigorous RCTs with longer follow-up periods are required to determine whether non-surgical interventions may result in a clinically important reduction in the duration of orthodontic treatment, without any adverse effects.
Topics: Adolescent; Child; Cuspid; Female; Humans; Male; Pain Measurement; Randomized Controlled Trials as Topic; Time Factors; Tooth Movement Techniques; Vibration; Young Adult
PubMed: 26576758
DOI: 10.1002/14651858.CD010887.pub2 -
European Journal of Preventive... Aug 2016Pulse palpation has been recommended as the first step of screening to detect atrial fibrillation. We aimed to determine and compare the accuracy of different methods... (Meta-Analysis)
Meta-Analysis Review
BACKGROUND
Pulse palpation has been recommended as the first step of screening to detect atrial fibrillation. We aimed to determine and compare the accuracy of different methods for detecting pulse irregularities caused by atrial fibrillation.
METHODS
We systematically searched MEDLINE, EMBASE, CINAHL and LILACS until 16 March 2015. Two reviewers identified eligible studies, extracted data and appraised quality using the QUADAS-2 instrument. Meta-analysis, using the bivariate hierarchical random effects method, determined average operating points for sensitivities, specificities, positive and negative likelihood ratios (PLR, NLR); we constructed summary receiver operating characteristic plots.
RESULTS
Twenty-one studies investigated 39 interventions (nā=ā15,129 pulse assessments) for detecting atrial fibrillation. Compared to 12-lead electrocardiography (ECG) diagnosed atrial fibrillation, blood pressure monitors (BPMs; seven interventions) and non-12-lead ECGs (20 interventions) had the greatest accuracy for detecting pulse irregularities attributable to atrial fibrillation (BPM: sensitivity 0.98 (95% confidence interval (CI) 0.92-1.00), specificity 0.92 (95% CI 0.88-0.95), PLR 12.1 (95% CI 8.2-17.8) and NLR 0.02 (95% CI 0.00-0.09); non-12-lead ECG: sensitivity 0.91 (95% CI 0.86-0.94), specificity 0.95 (95% CI 0.92-0.97), PLR 20.1 (95% CI 12-33.7), NLR 0.09 (95% CI 0.06-0.14)). There were similar findings for smartphone applications (six interventions) although these studies were small in size. The sensitivity and specificity of pulse palpation (six interventions) were 0.92 (95% CI 0.85-0.96) and 0.82 (95% CI 0.76-0.88), respectively (PLR 5.2 (95% CI 3.8-7.2), NLR 0.1 (95% CI 0.05-0.18)).
CONCLUSIONS
BPMs and non-12-lead ECG were most accurate for detecting pulse irregularities caused by atrial fibrillation; other technologies may therefore be pragmatic alternatives to pulse palpation for the first step of atrial fibrillation screening.
Topics: Atrial Fibrillation; Electrocardiography; Heart Rate; Humans; Palpation; ROC Curve
PubMed: 26464292
DOI: 10.1177/2047487315611347 -
BMJ Clinical Evidence Nov 2014Acute atrial fibrillation is rapid, irregular, and chaotic atrial activity of recent onset. Various definitions of acute atrial fibrillation have been used in the... (Review)
Review
INTRODUCTION
Acute atrial fibrillation is rapid, irregular, and chaotic atrial activity of recent onset. Various definitions of acute atrial fibrillation have been used in the literature, but for the purposes of this review we have included studies where atrial fibrillation may have occurred up to 7 days previously. Risk factors for acute atrial fibrillation include increasing age, cardiovascular disease, alcohol, diabetes, and lung disease. Acute atrial fibrillation increases the risk of stroke and heart failure. The condition resolves spontaneously within 24 to 48 hours in more than 50% of people; however, many people will require interventions to control heart rate or restore sinus rhythm.
METHODS AND OUTCOMES
We conducted a systematic review and aimed to answer the following clinical questions: What are the effects of interventions to prevent embolism, for conversion to sinus rhythm, and to control heart rate in people with recent-onset atrial fibrillation (within 7 days) who are haemodynamically stable? We searched: Medline, Embase, The Cochrane Library, and other important databases up to April 2014 (Clinical Evidence reviews are updated periodically; please check our website for the most up-to-date version of this review). We included harms alerts from relevant organisations such as the US Food and Drug Administration (FDA) and the UK Medicines and Healthcare products Regulatory Agency (MHRA).
RESULTS
We found 26 studies that met our inclusion criteria. We performed a GRADE evaluation of the quality of evidence for interventions.
CONCLUSIONS
In this systematic review, we present information relating to the effectiveness and safety of the following interventions: amiodarone, antithrombotic treatment before cardioversion, atenolol, bisoprolol, carvedilol, digoxin, diltiazem, direct current cardioversion, flecainide, metoprolol, nebivolol, propafenone, sotalol, timolol, and verapamil.
Topics: Acute Disease; Anti-Arrhythmia Agents; Atrial Fibrillation; Electric Countershock; Humans; Safety
PubMed: 25430048
DOI: No ID Found -
Ulusal Travma Ve Acil Cerrahi Dergisi =... Jan 2014A 25-year-old man was bitten in the neck by an aggressive camel, causing three small puncture wounds. The left carotid pulse of the patient was weakly palpated.... (Review)
Review
A 25-year-old man was bitten in the neck by an aggressive camel, causing three small puncture wounds. The left carotid pulse of the patient was weakly palpated. Angiography showed irregular dissection of the distal part of the left common carotid artery. Neck exploration confirmed the findings. An interposition autogenous saphenous vein graft was performed successfully. The patient was discharged home in good condition. We have systematically reviewed the literature on this topic, and only four other similar cases were reported previously. Although camel bite wounds are small, they may penetrate deeply, causing serious injuries to the neck structures including the major vessels. Care should be taken when approaching male camels during the rutting season.
Topics: Adult; Animals; Bites and Stings; Camelus; Carotid Artery Injuries; Humans; Male; Young Adult
PubMed: 24639318
DOI: 10.5505/tjtes.2014.69822 -
BMJ Clinical Evidence Feb 2011Acute atrial fibrillation is rapid, irregular, and chaotic atrial activity of less than 48 hours' duration. Risk factors for acute atrial fibrillation include increasing... (Review)
Review
INTRODUCTION
Acute atrial fibrillation is rapid, irregular, and chaotic atrial activity of less than 48 hours' duration. Risk factors for acute atrial fibrillation include increasing age, cardiovascular disease, alcohol, diabetes, and lung disease. Acute atrial fibrillation increases the risk of stroke and heart failure. The condition resolves spontaneously within 24 to 48 hours in over 50% of people; however, many people will require interventions to control heart rate or restore sinus rhythm.
METHODS AND OUTCOMES
We conducted a systematic review and aimed to answer the following clinical questions: What are the effects of interventions to prevent embolism, for conversion to sinus rhythm, and to control heart rate in people with recent-onset atrial fibrillation (within 7 days) who are haemodynamically stable? We searched: Medline, Embase, The Cochrane Library, and other important databases up to April 2010 (Clinical Evidence reviews are updated periodically; please check our website for the most up-to-date version of this review). We included harms alerts from relevant organisations such as the US Food and Drug Administration (FDA) and the UK Medicines and Healthcare products Regulatory Agency (MHRA).
RESULTS
We found 30 systematic reviews, RCTs, or observational studies that met our inclusion criteria. We performed a GRADE evaluation of the quality of evidence for interventions.
CONCLUSIONS
In this systematic review we present information relating to the effectiveness and safety of the following interventions: amiodarone, antithrombotic treatment before cardioversion, digoxin, diltiazem, direct current cardioversion, flecainide, propafenone, quinidine, sotalol, timolol, and verapamil.
Topics: Amiodarone; Anti-Arrhythmia Agents; Atrial Fibrillation; Humans; Propafenone; Sotalol
PubMed: 21718559
DOI: No ID Found