The Lancet. Digital Health Jul 2024Cooling towers containing Legionella spp are a high-risk source of Legionnaires' disease outbreaks. Manually locating cooling towers from aerial imagery during outbreak...
BACKGROUND
Cooling towers containing Legionella spp are a high-risk source of Legionnaires' disease outbreaks. Manually locating cooling towers from aerial imagery during outbreak investigations requires expertise, is labour intensive, and can be prone to errors. We aimed to train a deep learning computer vision model to automatically detect cooling towers that are aerially visible.
METHODS
Between Jan 1 and 31, 2021, we extracted satellite view images of Philadelphia (PN, USA) and New York state (NY, USA) from Google Maps and annotated cooling towers to create training datasets. We augmented training data with synthetic data and model-assisted labelling of additional cities. Using 2051 images containing 7292 cooling towers, we trained a two-stage model using YOLOv5, a model that detects objects in images, and EfficientNet-b5, a model that classifies images. We assessed the primary outcomes of sensitivity and positive predictive value (PPV) of the model against manual labelling on test datasets of 548 images, including from two cities not seen in training (Boston [MA, USA] and Athens [GA, USA]). We compared the search speed of the model with that of manual searching by four epidemiologists.
FINDINGS
The model identified visible cooling towers with 95·1% sensitivity (95% CI 94·0-96·1) and a PPV of 90·1% (95% CI 90·0-90·2) in New York City and Philadelphia. In Boston, sensitivity was 91·6% (89·2-93·7) and PPV was 80·8% (80·5-81·2). In Athens, sensitivity was 86·9% (75·8-94·2) and PPV was 85·5% (84·2-86·7). For an area of New York City encompassing 45 blocks (0·26 square miles), the model searched more than 600 times faster (7·6 s; 351 potential cooling towers identified) than did human investigators (mean 83·75 min [SD 29·5]; mean 310·8 cooling towers [42·2]).
INTERPRETATION
The model could be used to accelerate investigation and source control during outbreaks of Legionnaires' disease through the identification of cooling towers from aerial imagery, potentially preventing additional disease spread. The model has already been used by public health teams for outbreak investigations and to initialise cooling tower registries, which are considered best practice for preventing and responding to outbreaks of Legionnaires' disease.
FUNDING
None.
Topics: Humans; Disease Outbreaks; Legionnaires' Disease; Deep Learning; Air Conditioning; Philadelphia; New York; Legionella; Satellite Imagery
PubMed: 38906615
DOI: 10.1016/S2589-7500(24)00094-3 -
BMC Pulmonary Medicine Jun 2024Legionella pneumonia is one of the most severe types of atypical pneumonia, impairing multiple organ systems, posing a threat to life. Diagnosing Legionella pneumonia is...
BACKGROUND
Legionella pneumonia is one of the most severe types of atypical pneumonia, impairing multiple organ systems, posing a threat to life. Diagnosing Legionella pneumonia is challenging due to difficulties in culturing the bacteria and limitations in immunoassay sensitivity and specificity.
CASE PRESENTATION
This paper reports a rare case of sepsis caused by combined infection with Legionella pneumophila and Fusobacterium necrophorum, leading to respiratory failure, acute kidney injury, acute liver injury, myocardial damage, and electrolyte disorders. In addition, we systematically reviewed literature on patients with combined Legionella infections, analyzing their clinical features, laboratory results and diagnosis.
CONCLUSIONS
For pathogens that require prolonged incubation periods and are less sensitive to conventional culturing methods, metagenomic next-generation sequencing (mNGS) can be a powerful supplement to pathogen screening and plays a significant role in the auxiliary diagnosis of complex infectious diseases.
Topics: Humans; High-Throughput Nucleotide Sequencing; Legionella pneumophila; Legionnaires' Disease; Fusobacterium Infections; Fusobacterium necrophorum; Coinfection; Metagenomics; Male; Middle Aged; Pneumonia, Bacterial
PubMed: 38867173
DOI: 10.1186/s12890-024-03097-4 -
Cureus May 2024Legionnaires' disease is a potentially severe type of pneumonia most often caused by the organism . Exposure to this bacterial pathogen typically happens in the...
Legionnaires' disease is a potentially severe type of pneumonia most often caused by the organism . Exposure to this bacterial pathogen typically happens in the community but may also occur in the hospital setting. This report describes the case of a patient who presented due to 10 days of fever, shortness of breath, and diarrhea, with initial imaging demonstrating multifocal pneumonia. The patient was appropriately started on empiric antibiotics for community-acquired pneumonia and admitted to the medicine floor. The patient showed no meaningful improvement in his initial hospital course on empiric antibiotics with continued oxygen requirements. Meanwhile, urine Legionella antigen testing returned positive on hospital day four, and after tailoring antibiotics accordingly, the patient's clinical status improved significantly. This case report highlights the efficacy of broad testing in the initial admission and the need for constant re-evaluation in the context of a patient not improving with appropriate therapy.
PubMed: 38854237
DOI: 10.7759/cureus.59979 -
Nature Communications Jun 2024Bacterial adhesion is a fundamental process which enables colonisation of niche environments and is key for infection. However, in Legionella pneumophila, the causative...
Bacterial adhesion is a fundamental process which enables colonisation of niche environments and is key for infection. However, in Legionella pneumophila, the causative agent of Legionnaires' disease, these processes are not well understood. The Legionella collagen-like protein (Lcl) is an extracellular peripheral membrane protein that recognises sulphated glycosaminoglycans on the surface of eukaryotic cells, but also stimulates bacterial aggregation in response to divalent cations. Here we report the crystal structure of the Lcl C-terminal domain (Lcl-CTD) and present a model for intact Lcl. Our data reveal that Lcl-CTD forms an unusual trimer arrangement with a positively charged external surface and negatively charged solvent exposed internal cavity. Through molecular dynamics simulations, we show how the glycosaminoglycan chondroitin-4-sulphate associates with the Lcl-CTD surface via distinct binding modes. Our findings show that Lcl homologs are present across both the Pseudomonadota and Fibrobacterota-Chlorobiota-Bacteroidota phyla and suggest that Lcl may represent a versatile carbohydrate-binding mechanism.
Topics: Glycosaminoglycans; Bacterial Proteins; Molecular Dynamics Simulation; Legionella pneumophila; Protein Binding; Collagen; Crystallography, X-Ray; Chondroitin Sulfates; Bacterial Adhesion; Protein Domains; Legionnaires' Disease; Humans; Amino Acid Sequence
PubMed: 38851738
DOI: 10.1038/s41467-024-49255-4 -
Frontiers in Cellular and Infection... 2024, one of the main pathogens that causes community-acquired pneumonia, can lead to , a condition characterized predominantly by severe pneumonia. This disease, caused by...
, one of the main pathogens that causes community-acquired pneumonia, can lead to , a condition characterized predominantly by severe pneumonia. This disease, caused by the bacterium , can quickly progress to critical pneumonia and is often associated with damage to multiple organs. As a result, it requires close attention in terms of clinical diagnosis and treatment. Omadacycline, a new type of tetracycline derivative belonging to the aminomethylcycline class of antibiotics, is a semi-synthetic compound derived from minocycline. Its key structural feature, the aminomethyl modification, allows omadacycline to overcome bacterial resistance and broadens its range of effectiveness against bacteria. Clinical studies have demonstrated that omadacycline is not metabolized in the body, and patients with hepatic and renal dysfunction do not need to adjust their dosage. This paper reports a case of successful treatment of with omadacycline in a patient who initially did not respond to empirical treatment with moxifloxacin. The patient also experienced electrolyte disturbance, as well as dysfunction in the liver and kidneys, delirium, and other related psychiatric symptoms.
Topics: Humans; Tetracyclines; Anti-Bacterial Agents; Legionnaires' Disease; Legionella pneumophila; Treatment Outcome; Male; Community-Acquired Infections; Moxifloxacin; Middle Aged
PubMed: 38836055
DOI: 10.3389/fcimb.2024.1380312 -
Water Research Aug 2024Legionella is an opportunistic waterborne pathogen that causes Legionnaires' disease. It poses a significant public health risk, especially to vulnerable populations in...
Legionella is an opportunistic waterborne pathogen that causes Legionnaires' disease. It poses a significant public health risk, especially to vulnerable populations in health care facilities. It is ubiquitous in manufactured water systems and is transmitted via inhalation or aspiration of aerosols/water droplets generated from water fixtures (e.g., showers and hand basins). As such, the effective management of premise plumbing systems (building water systems) in health care facilities is essential for reducing the risk of Legionnaires' disease. Chemical disinfection is a commonly used control method and chlorine-based disinfectants, including chlorine, chloramine, and chlorine dioxide, have been used for over a century. However, the effectiveness of these disinfectants in premise plumbing systems is affected by various interconnected factors that can make it challenging to maintain effective disinfection. This systematic literature review identifies all studies that have examined the factors impacting the efficacy and decay of chlorine-based disinfectant within premise plumbing systems. A total of 117 field and laboratory-based studies were identified and included in this review. A total of 20 studies directly compared the effectiveness of the different chlorine-based disinfectants. The findings from these studies ranked the typical effectiveness as follows: chloramine > chlorine dioxide > chlorine. A total of 26 factors were identified across 117 studies as influencing the efficacy and decay of disinfectants in premise plumbing systems. These factors were sorted into categories of operational factors that are changed by the operation of water devices and fixtures (such as stagnation, temperature, water velocity), evolving factors which are changed in-directly (such as disinfectant concentration, Legionella disinfectant resistance, Legionella growth, season, biofilm and microbe, protozoa, nitrification, total organic carbon(TOC), pH, dissolved oxygen(DO), hardness, ammonia, and sediment and pipe deposit) and stable factors that are not often changed(such as disinfectant type, pipe material, pipe size, pipe age, water recirculating, softener, corrosion inhibitor, automatic sensor tap, building floor, and construction activity). A factor-effect map of each of these factors and whether they have a positive or negative association with disinfection efficacy against Legionella in premise plumbing systems is presented. It was also found that evaluating the effectiveness of chlorine disinfection as a water risk management strategy is further complicated by varying disinfection resistance of Legionella species and the form of Legionella (culturable/viable but non culturable, free living/biofilm associated, intracellular replication within amoeba hosts). Future research is needed that utilises sensors and other approaches to measure these key factors (such as pH, temperature, stagnation, water age and disinfection residual) in real time throughout premise plumbing systems. This information will support the development of improved models to predict disinfection within premise plumbing systems. The findings from this study will inform the use of chlorine-based disinfection within premise plumbing systems to reduce the risk of Legionnaires disease.
Topics: Disinfectants; Chlorine; Legionella; Disinfection; Chlorine Compounds; Water Microbiology; Chloramines; Water Supply; Oxides; Water Purification
PubMed: 38824796
DOI: 10.1016/j.watres.2024.121794 -
Microorganisms May 2024is a freshwater opportunistic pathogen and the leading cause of severe pneumonia known as Legionnaires' disease. It can be found in all water systems and survives in...
is a freshwater opportunistic pathogen and the leading cause of severe pneumonia known as Legionnaires' disease. It can be found in all water systems and survives in biofilms, free-living amoebae, and a wide variety of facilities, such as air conditioning and showers in hospitals, hotels and spas. The reference cultural method allows for the isolation and identification in many days, and in addition, it does not detect viable but rather non-culturable bacteria, increasing the risk of infection. In this context, a new LAMP-based (loop-mediated isothermal amplification) kit was developed, allowing for the rapid, sensitive, and labor-saving detection of . The kit, " Glow", was validated according to ISO/TS 12869:2012, testing sensitivity, inclusivity and exclusivity, and kit robustness. Sensitivity showed that the " Glow" kit can detect up to 28 plasmid copies/µL. Robustness tests showed consistent results, with both contamination levels and the matrices used giving reproducible results. Furthermore, real samples were evaluated to compare the performance of the two methods. The LAMP kit " Glow" proved a useful option for the rapid, efficient, and labor-saving screening of different typologies of water samples, offering significant advantages over the traditional method, as it is characterized by a high sensitivity, ease of use for laboratory testing, and a large reduction in analysis time, making it an asset to official controls.
PubMed: 38792790
DOI: 10.3390/microorganisms12050961 -
Microorganisms Apr 2024can cause a large panel of symptoms besides the classic pneumonia presentation. Here we present a case of fatal nosocomial cellulitis in an immunocompromised patient...
can cause a large panel of symptoms besides the classic pneumonia presentation. Here we present a case of fatal nosocomial cellulitis in an immunocompromised patient followed, a year later, by a second case of Legionnaires' disease in the same ward. While the first case was easily assumed as nosocomial based on the date of symptom onset, the second case required clear typing results to be assigned either as nosocomial and related to the same environmental source as the first case, or community acquired. To untangle this specific question, we applied core-genome multilocus typing (MLST), whole-genome single nucleotide polymorphism and whole-genome MLST methods to a collection of 36 Belgian and 41 international sequence-type 1 (ST1) isolates using both thresholds recommended in the literature and tailored threshold based on local epidemiological data. Based on the thresholds applied to cluster isolates together, the three methods gave different results and no firm conclusion about the nosocomial setting of the second case could been drawn. Our data highlight that despite promising results in the study of outbreaks and for large-scale epidemiological investigations, next-generation sequencing typing methods applied to ST1 outbreak investigation still need standardization regarding both wet-lab protocols and bioinformatics. A deeper evaluation of the evolutionary clock is also required to increase our understanding of genomic differences between isolates sampled during a clinical infection and in the environment.
PubMed: 38792686
DOI: 10.3390/microorganisms12050857 -
Euro Surveillance : Bulletin Europeen... May 2024Wastewater treatment plants (WWTPs) are increasingly identified as Legionnaires' disease (LD) sources. An outbreak investigation was initiated following five LD cases...
Wastewater treatment plants (WWTPs) are increasingly identified as Legionnaires' disease (LD) sources. An outbreak investigation was initiated following five LD cases reported in September 2022 in Houten, the Netherlands. Case identification was based on the European LD case definition, with symptom onset from 1 September 2022, residence in or within 5 km of Houten, or visit to Houten within the incubation period, without other likely sources. We sampled potential sources and genotyped environmental and clinical isolates. We identified 15 LD cases with onset between 13 September and 23 October 2022. A spatial source identification and wind direction model suggested an industrial (iWWTP) and a municipal WWTP (mWWTP) as potential sources, with the first discharging water into the latter. Both tested positive for serogroups 1 and 6 with multiple sequence types (ST). We detected sg1 ST42 in the mWWTP, matching with one of three available clinical isolates. Following control measures at the WWTPs, no further cases were observed. This outbreak underlines that municipal and industrial WWTPs can play an important role in community LD cases and outbreaks, especially those with favourable conditions for growth and dissemination, or even non-favourable conditions for growth but with the influx of contaminated water.
Topics: Legionnaires' Disease; Humans; Disease Outbreaks; Netherlands; Wastewater; Legionella pneumophila; Male; Middle Aged; Aged; Female; Water Microbiology; Water Purification; Adult; Genotype
PubMed: 38757288
DOI: 10.2807/1560-7917.ES.2024.29.20.2300506 -
International Immunopharmacology Jun 2024Patients with diabetes are particularly susceptible to Legionella pneumophila (LP) infection, but the exact pathogenesis of LP infection in diabetic patients is still...
BACKGROUND
Patients with diabetes are particularly susceptible to Legionella pneumophila (LP) infection, but the exact pathogenesis of LP infection in diabetic patients is still not fully understood. Herein, we investigated the effect of diabetes on immune function during LP infection in vitro and in vivo.
METHODS
The time course of LP infection in macrophages under normal and high-glucose (HG) conditions was examined in vitro. Western blot was used to determine nucleotide-binding oligomerization domain 1 (NOD1), kinase 1/2 (ERK1/2), mitogen-activated protein kinase p38 (MAPK p38), and c-Jun N-terminal kinases (JNK). Enzyme-linked immunosorbent assay (ELISA) was used to assess the secretion of tumor necrosis factor-α (TNF-α) and interleukin-6 (IL-6). Cell Counting Kit-8 (CCK8) assay assessed U937 cell viability after treating cells with different concentrations of high sugar medium and ML130 (NOD1 inhibitor). For the in vivo study, normal and streptozocin-induced diabetic guinea pigs were infected with LP for 6, 24, and 72 h, after which NOD1, MAPK-related signals, TNF-α, and IL-6 expression in lung tissues were assessed using immunohistochemistry, western blot, and RT-PCR.
RESULTS
HG attenuated the upregulation of NOD1 expression and reduced TNF-α and IL-6 secretion caused by LP compared with LP-infected cells exposed to normal glucose levels (all p < 0.05). In diabetic guinea pigs, HG inhibited the upregulation of NOD1 expression in lung tissues and the activation of p38, ERK1/2, and cJNK caused by LP infection compared to control pigs (all p < 0.05).
CONCLUSION
HG attenuates the response of macrophages to LP infection by inhibiting NOD1 upregulation and the activation of MAPK signaling.
Topics: Nod1 Signaling Adaptor Protein; Animals; Humans; Macrophages; Legionella pneumophila; Glucose; Guinea Pigs; Male; Interleukin-6; Legionnaires' Disease; Diabetes Mellitus, Experimental; MAP Kinase Signaling System; U937 Cells; Tumor Necrosis Factor-alpha; Mice
PubMed: 38749333
DOI: 10.1016/j.intimp.2024.112254