-
Nanomaterials (Basel, Switzerland) Jun 2024Developing cost-effective and highly active electrocatalysts for the oxygen evolution reaction (OER) is crucial for advancing sustainable energy applications....
Developing cost-effective and highly active electrocatalysts for the oxygen evolution reaction (OER) is crucial for advancing sustainable energy applications. High-entropy alloys (HEAs) made from earth-abundant transition metals, thanks to their remarkable stability and electrocatalytic performance, provide a promising alternative to expensive electrocatalysts typically derived from noble metals. While pristine HEA surfaces have been theoretically investigated, and the effect of oxygen coverage on conventional metal electrocatalysts has been examined, the impact of surface oxygen coverage on the electrocatalytic performance of HEAs remains poorly understood. To bridge this gap, we employ density functional theory (DFT) calculations to reconstruct the free energy diagram of OER intermediates on CoFeNiCr HEA surfaces with varying oxygen coverages, evaluating their impact on the rate-limiting step and theoretical overpotential. Our findings reveal that increased oxygen coverage weakens the adsorption of HO* and O*, but not HOO*. As a result, the theoretical overpotential for the OER decreases with higher oxygen coverage, and the rate-limiting step shifts from the third oxidation step (HOO* formation) at low coverage to the first oxidation step (HO* formation) at higher coverage.
PubMed: 38921934
DOI: 10.3390/nano14121058 -
Nanomaterials (Basel, Switzerland) Jun 2024Hydrogen energy, known for its high energy density, environmental friendliness, and renewability, stands out as a promising alternative to fossil fuels. However, its... (Review)
Review
Hydrogen energy, known for its high energy density, environmental friendliness, and renewability, stands out as a promising alternative to fossil fuels. However, its broader application is limited by the challenge of efficient and safe storage. In this context, solid-state hydrogen storage using nanomaterials has emerged as a viable solution to the drawbacks of traditional storage methods. This comprehensive review delves into the recent advancements in nanomaterials for solid-state hydrogen storage, elucidating the fundamental principles and mechanisms, highlighting significant material systems, and exploring the strategies of surface and interface engineering alongside catalytic enhancement. We also address the primary challenges and provide future perspectives on the development of nanomaterial-based hydrogen storage technologies. Key discussions include the role of nanomaterial size effects, surface modifications, nanocomposites, and nanocatalysts in optimizing storage performance.
PubMed: 38921912
DOI: 10.3390/nano14121036 -
Nanomaterials (Basel, Switzerland) Jun 2024The corrosion behavior of 20G and TP347H materials was investigated in molten LiCl-NaCl-KCl salt. The corrosion rates of these materials in molten chloride salt are high...
The corrosion behavior of 20G and TP347H materials was investigated in molten LiCl-NaCl-KCl salt. The corrosion rates of these materials in molten chloride salt are high and are strongly affected by the alloying surface oxide formation. The 20G shows uniform surface corrosion with almost no protective oxide formation on the surface. In contrast, the austenitic steel TP347H exhibits better corrosion resistance in molten chloride salts due to its high Cr content. Owing to the highly corrosive nature of molten chloride salts, the Cl in molten salt could react with oxides and alloy, inducing intergranular corrosion of austenitic steel in molten chloride salt environments.
PubMed: 38921902
DOI: 10.3390/nano14121026 -
Nanomaterials (Basel, Switzerland) Jun 2024The low hardness and poor wear resistance of laser-cladding 316L stainless steel impose significant constraints on its practical applications. In this study, a strategy...
The low hardness and poor wear resistance of laser-cladding 316L stainless steel impose significant constraints on its practical applications. In this study, a strategy for strengthening laser-cladding 316L stainless steel with WMoTaNb refractory high-entropy alloy as a reinforcement material is proposed. The results confirm that the coating primarily comprises a body-centered cubic (BCC) Fe-based solid solution, a network-distributed hexagonal FeX (X = W, Mo, Ta, and Nb) Laves phase, and a diffusely distributed face-centered cubic (FCC) (Ta, Nb)C phase. The Fe-based solid solution distributes along columnar and fine dendrites, while the Laves phase and (Ta, Nb)C phase are in the inter-dendrites. The presence of a significant number of network Laves phases exhibiting high strength and hardness is the primary factor contributing to the enhancement of coating microhardness. The hardness of the composite coating is increased by nearly twice compared to that of the 316L coating, resulting in an improved wear resistance. The present work can shed light on designing and fabricating 316L stainless steel coating with enhanced hardness and wear resistance.
PubMed: 38921892
DOI: 10.3390/nano14121016 -
Journal of Functional Biomaterials Jun 2024In the original publication [...].
In the original publication [...].
PubMed: 38921543
DOI: 10.3390/jfb15060159 -
Journal of Functional Biomaterials Jun 2024With the rising demand for medical implants and the dominance of implant-associated failures including infections, extensive research has been prompted into the...
With the rising demand for medical implants and the dominance of implant-associated failures including infections, extensive research has been prompted into the development of novel biomaterials that can offer desirable characteristics. This study develops and evaluates new titanium-based alloys containing gallium additions with the aim of offering beneficial antibacterial properties while having a reduced stiffness level to minimise the effect of stress shielding when in contact with bone. The focus is on the microstructure, mechanical properties, antimicrobial activity, and cytocompatibility to inform the suitability of the designed alloys as biometals. Novel Ti-33Nb-xGa alloys (x = 3, 5 wt%) were produced via casting followed by homogenisation treatment, where all results were compared to the currently employed alloy Ti-6Al-4V. Optical microscopy, scanning electron microscopy (SEM), and energy dispersive spectroscopy (EDS) results depicted a single beta (β) phase microstructure in both Ga-containing alloys, where Ti-33Nb-5Ga was also dominated by dendritic alpha (α) phase grains in a β-phase matrix. EDS analysis indicated that the α-phase dendrites in Ti-33Nb-5Ga were enriched with titanium, while the β-phase was richer in niobium and gallium elements. Mechanical properties were measured using nanoindentation and microhardness methods, where the Young's modulus for Ti-33Nb-3Ga and Ti-33Nb-5Ga was found to be 75.4 ± 2.4 and 67.2 ± 1.6 GPa, respectively, a significant reduction of 37% and 44% with respect to Ti-6Al-4V. This reduction helps address the disproportionate Young's modulus between titanium implant components and cortical bone. Importantly, both alloys successfully achieved superior antimicrobial properties against Gram-negative and Gram-positive bacteria. Antibacterial efficacy was noted at up to 90 ± 5% for the 3 wt% alloy and 95 ± 3% for the 5 wt% alloy. These findings signify a substantial enhancement of the antimicrobial performance when compared to Ti-6Al-4V which exhibited very small rates (up to 6.3 ± 1.5%). No cytotoxicity was observed in hGF cell lines over 24 h. Cell morphology and cytoskeleton distribution appeared to depict typical morphology with a prominent nucleus, elongated fibroblastic spindle-shaped morphology, and F-actin filamentous stress fibres in a well-defined structure of parallel bundles along the cellular axis. The developed alloys in this work have shown very promising results and are suggested to be further examined towards the use of orthopaedic implant components.
PubMed: 38921540
DOI: 10.3390/jfb15060167 -
Journal of Functional Biomaterials Jun 2024The objective of this work was to analyze the in vitro and in vivo tests of a novel Mg-based biodegradable alloy-Mg-0.5%Ca-with various amounts of Zn (0.5, 1, 1.5, 2.0,...
The objective of this work was to analyze the in vitro and in vivo tests of a novel Mg-based biodegradable alloy-Mg-0.5%Ca-with various amounts of Zn (0.5, 1, 1.5, 2.0, and 3.0 wt.%). In terms of in vitro biocompatibility, MTT and Calcein-AM cell viability assays, performed on the MG-63 cell line through the extract method, revealed that all five alloy extracts are non-cytotoxic at an extraction ratio of 0.025 g alloy per mL of cell culture medium. In the in vivo histological analysis, Mg-0.5Ca-1.5Zn demonstrated exceptional potential for stimulating bone remodeling and showed excellent biocompatibility. It was observed that Mg-0.5Ca-0.5Zn, Mg-0.5Ca-1.5Zn, and Mg-0.5Ca-3Zn displayed good biocompatibility. Furthermore, the histological examination highlighted the differentiation of periosteal cells into chondrocytes and subsequent bone tissue replacement through endochondral ossification. This process highlighted the importance of the initial implant's integrity and the role of the periosteum. In summary, Mg-0.5Ca-1.5Zn stands out as a promising candidate for bone regeneration and osseointegration, supported by both in vitro and in vivo findings.
PubMed: 38921539
DOI: 10.3390/jfb15060166 -
Journal of Functional Biomaterials Jun 2024The design of new, biomimetic biomaterials is of great strategic interest and is converging for many applications, including in implantology. This study explores a novel...
The design of new, biomimetic biomaterials is of great strategic interest and is converging for many applications, including in implantology. This study explores a novel approach to improving dental implants. Although endosseous TA6V alloy dental implants are widely used in oral implantology, this material presents significant challenges, notably the prevalence of peri-implantitis. Therefore, in this study, we investigate a new advance in the design of hybrid medical devices. This involves the design of a Ca-SZ coating deposited by PVD on a TA6V substrate. This approach aims to overcome the inherent limitations of each of these materials, namely TA6V's susceptibility to peri-implantitis on the one hand and zirconia's excessively high Young's modulus compared with bone on the other, while benefiting from their respective advantages, such as the ductility of TA6V and the excellent biocompatibility of zirconia, offering relevant prospects for the design of high-performance implantable medical devices. This study integrates characterisation techniques, focusing on the structural and elemental analysis of the Ca-SZ coating by XRD and TEM. The results suggest that this coating combines a tetragonal structure, a uniform morphology with no apparent defects, a clean interface highlighting good adhesion, and a homogeneous composition of calcium, predisposing it to optimal biocompatibility. All of these findings make this innovative coating a particularly suitable candidate for application in dental implantology.
PubMed: 38921529
DOI: 10.3390/jfb15060155 -
Biomimetics (Basel, Switzerland) May 2024This work introduces a neuromorphic sensor (NS) based on force-sensing resistors (FSR) and spiking neurons for robotic systems. The proposed sensor integrates the FSR in...
This work introduces a neuromorphic sensor (NS) based on force-sensing resistors (FSR) and spiking neurons for robotic systems. The proposed sensor integrates the FSR in the schematic of the spiking neuron in order to make the sensor generate spikes with a frequency that depends on the applied force. The performance of the proposed sensor is evaluated in the control of a SMA-actuated robotic finger by monitoring the force during a steady state when the finger pushes on a tweezer. For comparison purposes, we performed a similar evaluation when the SNN received input from a widely used compression load cell (CLC). The results show that the proposed FSR-based neuromorphic sensor has very good sensitivity to low forces and the function between the spiking rate and the applied force is continuous, with good variation range. However, when compared to the CLC, the response of the NS follows a logarithmic-like function with improved sensitivity for small forces. In addition, the power consumption of NS is 128 µW that is 270 times lower than that of the CLC which needs 3.5 mW to operate. These characteristics make the neuromorphic sensor with FSR suitable for bioinspired control of humanoid robotics, representing a low-power and low-cost alternative to the widely used sensors.
PubMed: 38921206
DOI: 10.3390/biomimetics9060326 -
Entropy (Basel, Switzerland) May 2024High-temperature creep refers to the slow and continuous plastic deformation of materials under the effects of high temperatures and mechanical stress over extended...
High-temperature creep refers to the slow and continuous plastic deformation of materials under the effects of high temperatures and mechanical stress over extended periods, which can lead to the degradation or even failure of the components' functionality. AlCrNbTiV (x = 0.2, 0.5, or 0.8) refractory high-entropy alloys were fabricated by arc melting. The effects of Al content on the microstructure of AlCrNbTiV alloys were studied using X-ray diffraction, scanning electron microscopy, and electron backscatter diffraction. The microhardness, compression properties, and nanoindentation creep properties of AlCrNbTiV alloys were also tested. The results show that the AlCrNbTiV series exhibits a BCC single-phase structure. As the Al content increases, the lattice constant of the alloys gradually decreases, and the intensity of the (110) crystal plane diffraction peak increases. Adding aluminum enhances the effect of solution strengthening; however, due to grain coarsening, the microhardness and room temperature compressive strength of the alloy are only slightly improved. Additionally, because the effect of solution strengthening is diminished at high temperatures, the compressive strength of the alloy at 1000 °C is significantly reduced. The creep mechanism of the alloys is predominantly governed by dislocation creep. Moreover, increasing the Al content helps to reduce the sensitivity of the alloy to the loading rate during the creep process. At a loading rate of 2.5 mN/s, the AlCrNbTiV alloy exhibits the lowest creep strain rate sensitivity index (m), which is 0.0758.
PubMed: 38920444
DOI: 10.3390/e26060435