-
Frontiers in Pediatrics 2024Exchange transfusion therapy is a complex and invasive procedure with a high risk coefficient. This method involves replacing the entire blood of a child with fresh...
BACKGROUND
Exchange transfusion therapy is a complex and invasive procedure with a high risk coefficient. This method involves replacing the entire blood of a child with fresh blood with double circulating blood volume in a short period, typically in 1-2 h. This procedure can cause the body's internal environment to be unstable, which can put newborns under a lot of stress. This stress can lead to many, including abnormal laboratory biochemical examination, low or high blood pressure, and apnea. There is also the possibility of secondary infection and, in severe cases, cardiac arrest. This study investigated the effects of Humidified high-flow nasal cannula (HHFNC) ventilation on hemodynamic stability and oxygenation during exchange transfusion in neonates. Furthermore, the effects on brain metabolism and salivary cortisol during exchange transfusion were also analyzed.
METHODS
In this study, the control group consisted of 45 cases of children who underwent simple blood exchange between 1 May 2017, and 31 December 2019 control group. The observation group consisted of 33 cases of children who underwent blood exchange under HHFNC support between 1 January 2020, and 30 April 2022. The study compared various physiological parameters between the control and the observation group. These included blood gas analysis, pulmonary artery pressure, ejection fraction, invasive mean arterial pressure, heart rate, cerebral oxygenation, intestinal oxygenation, renal oxygenation, and duration of blood exchange. Furthermore, the study also compared the changes in brain metabolic and salivary cortisol indicators between the two groups of children.
RESULTS
The results did not reveal any significant difference in PH, PaO and duration of blood exchange between the control and the observation group. However, the observation group's invasive mean arterial pressure, ejection fraction, cerebral oxygenation, intestinal oxygenation, and renal oxygenation were higher than those of the control group. Furthermore, compared with the control group, the pulmonary artery pressure, heart rate, and PaCO were lower in the observation group. There was a statistically significant difference between the two groups of children in the relevant clinical indicators (total bilirubin, hemoglobin, SPO, etc.) after exchange transfusion. After 1 h of blood exchange and after blood exchange, the salivary cortisol levels of the observation group were lower than the control group. The difference was statistically significant. The NAA/Cho and Cho/Cr values of the two groups of children were also significantly different.
CONCLUSION
During blood exchange, unstable hemodynamics substantially impact organ oxygenation. The results of this study suggest that HHFNC and specific ventilation pressure support can improve the respiratory rate and help maintain blood flow stability and organ oxygenation. This technique can also reduce adverse reactions caused by blood exchange, minimizing patient stress and reducing the impact on brain metabolism.
PubMed: 38884105
DOI: 10.3389/fped.2024.1381808 -
MedRxiv : the Preprint Server For... Jun 2024Atrial fibrillation (AF) is often asymptomatic and thus under-observed. Given the high risks of stroke and heart failure among patients with AF, early prediction and...
BACKGROUND
Atrial fibrillation (AF) is often asymptomatic and thus under-observed. Given the high risks of stroke and heart failure among patients with AF, early prediction and effective management are crucial. Importantly, obstructive sleep apnea is highly prevalent among AF patients (60-90%); therefore, electrocardiogram (ECG) analysis from polysomnography (PSG), a standard diagnostic tool for subjects with suspected sleep apnea, presents a unique opportunity for the early prediction of AF. Our goal is to identify individuals at a high risk of developing AF in the future from a single-lead ECG recorded during standard PSGs.
METHODS
We analyzed 18,782 single-lead ECG recordings from 13,609 subjects at Massachusetts General Hospital, identifying AF presence using ICD-9/10 codes in medical records. Our dataset comprises 15,913 recordings without a medical record for AF and 2,056 recordings from patients who were first diagnosed with AF between 1 day to 15 years after the PSG recording. The PSG data were partitioned into training, validation, and test cohorts. In the first phase, a signal quality index (SQI) was calculated in 30-second windows and those with SQI 0.95 were removed. From each remaining window, 150 hand-crafted features were extracted from time, frequency, time-frequency domains, and phase-space reconstructions of the ECG. A compilation of 12 statistical features summarized these window-specific features per recording, resulting in 1,800 features. We then updated a pre-trained deep neural network and data from the PhysioNet Challenge 2021 using transfer-learning to discriminate between recordings with and without AF using the same Challenge data. The model was applied to the PSG ECGs in 16-second windows to generate the probability of AF for each window. From the resultant probability sequence, 13 statistical features were extracted. Subsequently, we trained a shallow neural network to predict future AF using the extracted ECG and probability features.
RESULTS
On the test set, our model demonstrated a sensitivity of 0.67, specificity of 0.81, and precision of 0.3 for predicting AF. Further, survival analysis for AF outcomes, using the log-rank test, revealed a hazard ratio of 8.36 (p-value of 1.93 × 10 ).
CONCLUSIONS
Our proposed ECG analysis method, utilizing overnight PSG data, shows promise in AF prediction despite a modest precision indicating the presence of false positive cases. This approach could potentially enable low-cost screening and proactive treatment for high-risk patients. Ongoing refinement, such as integrating additional physiological parameters could significantly reduce false positives, enhancing its clinical utility and accuracy.
PubMed: 38883765
DOI: 10.1101/2024.06.04.24308444 -
Journal of Thoracic Disease May 2024Theophylline has been used for decades in human medicine for its psychostimulant, anti-inflammatory, and bronchodilator effects. Historically, in pulmonary medicine,... (Review)
Review
BACKGROUND AND OBJECTIVE
Theophylline has been used for decades in human medicine for its psychostimulant, anti-inflammatory, and bronchodilator effects. Historically, in pulmonary medicine, theophylline has been used in the treatment of obstructive pulmonary diseases such as bronchial asthma (BA) or chronic obstructive pulmonary disease (COPD). This review aims to determine whether theophylline still has its place in the therapy of obstructive pulmonary diseases or whether we can even extend its use to other diagnoses such as atropine-resistant cardiac arrests, apnea of prematurity, or others. Moreover, we also aim to determine if there is a rationale for using low-dose theophylline due to its immunomodulatory and anti-inflammatory effect, or if the future of methylxanthines lies in newly synthesized derivates of theophylline such as bamifylline, or doxofylline.
METHODS
The narrative review is based on a literature search of the articles indexed in the PubMed database in 2023. We searched the database since the year 2009 using the MeSH terms "theophylline", "aminophylline", and "methylxanthines" and we included original articles in the English language.
KEY CONTENT AND FINDINGS
Theophylline has a number of adverse drug reactions (ADRs), the most serious of which is its effect on the cardiovascular system. It can cause severe arrhythmias or even cardiac arrest when overdosed. On the other hand, there is still a substantial amount of its applications in current clinical practice.
CONCLUSIONS
There is considerable controversy associated with its use in current medicine, which can be attributed both to its narrow therapeutic range and its mentioned cardiotoxic effect. Herein, we summarize the current state-of-art of theophylline and its use in human medicine.
PubMed: 38883616
DOI: 10.21037/jtd-23-1781 -
Nature and Science of Sleep 2024The COVID-19 pandemic affected the utilization of various healthcare services differentially. Sleep testing services utilization (STU), including Home Sleep Apnea...
PURPOSE
The COVID-19 pandemic affected the utilization of various healthcare services differentially. Sleep testing services utilization (STU), including Home Sleep Apnea Testing (HSAT) and Polysomnography (PSG), were uniquely affected. We assessed the effects of the pandemic on STU and its recovery using the Veterans Health Administration (VHA) data.
PATIENTS AND METHODS
A retrospective cohort study from the VHA between 01/2019 and 10/2023 of veterans with age ≥ 50. We extracted STU data using Current Procedural Terminology codes for five periods based on STU and vaccination status: pre-pandemic (Pre-Pan), pandemic sleep test moratorium (Pan-Mor), and pandemic pre-vaccination (Pan-Pre-Vax), vaccination (Pan-Vax), and postvaccination (Pan-Post-Vax). We compared STU between intervals (Pre-Pan as the reference).
RESULTS
Among 261,371 veterans (63.7±9.6 years, BMI 31.9±6.0 kg/m², 80% male), PSG utilization decreased significantly during Pan-Mor (-56%), Pan-Pre-Vax (-61%), Pan-Vax (-42%), and Pan-Post-Vax (-36%) periods all compared to Pre-Pan. HSAT utilization decreased significantly during the Pan-Mor (-59%) and Pan-Pre-Vax (-9%) phases compared to the Pre-Pan and subsequently increased during Pan-Vax (+6%) and Pan-Post-Vax (-1%) periods. Over 70% of STU transitioned to HSAT, and its usage surged five months after the vaccine Introduction.
CONCLUSION
Sleep testing services utilization recovered differentially during the pandemic (PSG vs HSAT), including a surge in HSAT utilization post-vaccination.
PubMed: 38882925
DOI: 10.2147/NSS.S456214 -
Nature and Science of Sleep 2024Obstructive sleep apnea (OSA) is a respiratory disorder characterized by chronic intermittent hypoxia and fragmented sleep, leading to inflammatory response and...
INTRODUCTION
Obstructive sleep apnea (OSA) is a respiratory disorder characterized by chronic intermittent hypoxia and fragmented sleep, leading to inflammatory response and oxidative stress. However, the differences in immune inflammatory response in OSA patients with different severity remain unclear.
PURPOSE
This study aims to examine the differences in peripheral blood immune cells and their risk factors in OSA patients.
PATIENTS AND METHODS
A total of 277 snoring patients from the Sleep Respiratory Disorder Monitoring Center of Zhongnan Hospital of Wuhan University were recruited in this study. According to the diagnosis and severity criteria of OSA, the included patients were further divided into simple snoring, mild, moderate, and severe groups. Peripheral blood immune cell counts including white blood cells, neutrophils, lymphocytes, monocytes, eosinophils, basophils, red blood cells, platelets, and polysomnography indicators were collected from the patients.
RESULTS
Compared with simple snoring patients, the OSA patients had increased circular monocyte and basophil count levels. In addition, correlation analysis results indicated that monocyte count was positively associated with chronic obstructive pulmonary disease (COPD), smoking, apnea-hypopnea index (AHI), the longest apnea duration, and Oxygen desaturation index (ODI), and negatively correlated with average SpO in snoring patients. Finally, multiple linear regression analysis revealed that AHI, COPD, smoking, and maximum heart rate were independent predictors of monocyte count.
CONCLUSION
OSA patients had a significant increase in their peripheral blood monocyte count. AHI, COPD, smoking, and maximum heart rate were risk factors for increased peripheral blood monocyte count in OSA patients. These findings suggest that peripheral blood monocytes can be considered an inflammatory biomarker of OSA.
PubMed: 38882924
DOI: 10.2147/NSS.S458098 -
Journal of Cardiothoracic and Vascular... Apr 2024
PubMed: 38876814
DOI: 10.1053/j.jvca.2024.04.017 -
JMIR Biomedical Engineering Apr 2024Obstructive sleep apnea/hypopnea syndrome (OSAHS) is a prevalent condition affecting a substantial portion of the global population, with its prevalence increasing over...
BACKGROUND
Obstructive sleep apnea/hypopnea syndrome (OSAHS) is a prevalent condition affecting a substantial portion of the global population, with its prevalence increasing over the past 2 decades. OSAHS is characterized by recurrent upper airway (UA) closure during sleep, leading to significant impacts on quality of life and heightened cardiovascular and metabolic morbidity. Despite continuous positive airway pressure (CPAP) being the gold standard treatment, patient adherence remains suboptimal due to various factors, such as discomfort, side effects, and treatment unacceptability.
OBJECTIVE
Considering the challenges associated with CPAP adherence, an alternative approach targeting the UA muscles through myofunctional therapy was explored. This noninvasive intervention involves exercises of the lips, tongue, or both to improve oropharyngeal functions and mitigate the severity of OSAHS. With the goal of developing a portable device for home-based myofunctional therapy with continuous monitoring of exercise performance and adherence, the primary outcome of this study was the degree of completion and adherence to a 4-week training session.
METHODS
This proof-of-concept study focused on a portable device that was designed to facilitate tongue and lip myofunctional therapy and enable precise monitoring of exercise performance and adherence. A clinical study was conducted to assess the effectiveness of this program in improving sleep-disordered breathing. Participants were instructed to perform tongue protrusion, lip pressure, and controlled breathing as part of various tasks 6 times a week for 4 weeks, with each session lasting approximately 35 minutes.
RESULTS
Ten participants were enrolled in the study (n=8 male; mean age 48, SD 22 years; mean BMI 29.3, SD 3.5 kg/m; mean apnea-hypopnea index [AHI] 20.7, SD 17.8/hour). Among the 8 participants who completed the 4-week program, the overall compliance rate was 91% (175/192 sessions). For the tongue exercise, the success rate increased from 66% (211/320 exercises; SD 18%) on the first day to 85% (272/320 exercises; SD 17%) on the last day (P=.05). AHI did not change significantly after completion of training but a noteworthy correlation between successful lip exercise improvement and AHI reduction in the supine position was observed (R=-0.76; P=.03). These findings demonstrate the potential of the device for accurately monitoring participants' performance in lip and tongue pressure exercises during myofunctional therapy. The diversity of the training program (it mixed exercises mixed training games), its ability to provide direct feedback for each exercise to the participants, and the easy measurement of treatment adherence are major strengths of our training program.
CONCLUSIONS
The study's portable device for home-based myofunctional therapy shows promise as a noninvasive alternative for reducing the severity of OSAHS, with a notable correlation between successful lip exercise improvement and AHI reduction, warranting further development and investigation.
PubMed: 38875673
DOI: 10.2196/51901 -
JMIR Biomedical Engineering Oct 2023Accurate and portable respiratory parameter measurements are critical for properly managing chronic obstructive pulmonary diseases (COPDs) such as asthma or sleep apnea,...
BACKGROUND
Accurate and portable respiratory parameter measurements are critical for properly managing chronic obstructive pulmonary diseases (COPDs) such as asthma or sleep apnea, as well as controlling ventilation for patients in intensive care units, during surgical procedures, or when using a positive airway pressure device for sleep apnea.
OBJECTIVE
The purpose of this research is to develop a new nonprescription portable measurement device that utilizes relative humidity sensors (RHS) to accurately measure key respiratory parameters at a cost that is approximately 10 times less than the industry standard.
METHODS
We present the development, implementation, and assessment of a wearable respiratory measurement device using the commercial Bosch BME280 RHS. In the initial stage, the RHS was connected to the pneumotach (PNT) gold standard device via its external connector to gather breathing metrics. Data collection was facilitated using the Arduino platform with a Bluetooth Low Energy connection, and all measurements were taken in real time without any additional data processing. The device's efficacy was tested with 7 participants (5 men and 2 women), all in good health. In the subsequent phase, we specifically focused on comparing breathing cycle and respiratory rate measurements and determining the tidal volume by calculating the region between inhalation and exhalation peaks. Each participant's data were recorded over a span of 15 minutes. After the experiment, detailed statistical analysis was conducted using ANOVA and Bland-Altman to examine the accuracy and efficiency of our wearable device compared with the traditional methods.
RESULTS
The perfused air measured with the respiratory monitor enables clinicians to evaluate the absolute value of the tidal volume during ventilation of a patient. In contrast, directly connecting our RHS device to the surgical mask facilitates continuous lung volume monitoring. The results of the 1-way ANOVA showed high P values of .68 for respiratory volume and .89 for respiratory rate, which indicate that the group averages with the PNT standard are equivalent to those with our RHS platform, within the error margins of a typical instrument. Furthermore, analysis utilizing the Bland-Altman statistical method revealed a small bias of 0.03 with limits of agreement (LoAs) of -0.25 and 0.33. The RR bias was 0.018, and the LoAs were -1.89 and 1.89.
CONCLUSIONS
Based on the encouraging results, we conclude that our proposed design can be a viable, low-cost wearable medical device for pulmonary parametric measurement to prevent and predict the progression of pulmonary diseases. We believe that this will encourage the research community to investigate the application of RHS for monitoring the pulmonary health of individuals.
PubMed: 38875670
DOI: 10.2196/47146 -
Nature and Science of Sleep 2024This study aimed to evaluate nocturnal sleep structure and anxiety, depression, and fatigue in patients with narcolepsy type 1 (NT1).
PURPOSE
This study aimed to evaluate nocturnal sleep structure and anxiety, depression, and fatigue in patients with narcolepsy type 1 (NT1).
METHODS
Thirty NT1 patients and thirty-five healthy controls were enrolled and evaluated using the Epworth sleepiness scale (ESS), Generalized Anxiety Disorder-7, Patient Health Questionnaire-9, Fatigue Severity Scale (FSS), polysomnography, multiple sleep latency test, and brain function state monitoring. Statistical analyses were performed using SPSS Statistics for Windows, version 23.0. Benjamini-Hochberg correction was performed to control the false discovery rate.
RESULTS
Apart from typical clinical manifestations, patients with NT1 are prone to comorbidities such as nocturnal sleep disorders, anxiety, depression, and fatigue. Compared with the control group, patients with NT1 exhibited abnormal sleep structure, including increased total sleep time ( =0.007), decreased sleep efficiency ( =0.002), shortening of sleep onset latency ( <0.001), elevated wake after sleep onset ( =0.002), increased N1% ( =0.006), and reduced N2%, N3%, and REM% ( =0.007, <0.001, =0.013). Thirty-seven percent of patients had moderate to severe obstructive sleep apnea-hypopnea syndrome. And sixty percent of patients were complicated with REM sleep without atonia. Patients with NT1 displayed increased anxiety propensity ( <0.001), and increased brain fatigue ( =0.020) in brain function state monitoring. FSS scores were positively correlated with brain fatigue ( <0.001) and mean sleep latency was inversely correlated with FSS scores and brain fatigue ( =0.013, =0.029). Additionally, ESS scores and brain fatigue decreased after 3 months of therapy (=0.012, =0.030).
CONCLUSION
NT1 patients had abnormal nocturnal sleep structures, who showed increased anxiety, depression, and fatigue. Excessive daytime sleepiness and fatigue improved after 3 months of treatment with methylphenidate hydrochloride prolonged-release tablets in combination with venlafaxine.
PubMed: 38873239
DOI: 10.2147/NSS.S452665 -
Cureus May 2024Beta-thalassemia (β-thalassemia) is a hematologic genetic condition that causes microcytic anemia due to defective synthesis of the hemoglobin beta chain. As a...
Beta-thalassemia (β-thalassemia) is a hematologic genetic condition that causes microcytic anemia due to defective synthesis of the hemoglobin beta chain. As a hypochromic microcytic anemia that is commonly associated with symptoms such as fatigue and pallor when identified in adulthood, β-thalassemia may be commonly underdiagnosed or misdiagnosed as iron deficiency anemia. This study presents a case of a patient with β-thalassemia who was initially misdiagnosed with treatment-resistant iron deficiency anemia. Here, we present the case of a 66-year-old male of Mediterranean descent with a history of military service who presented with persistent fatigue. He had a past medical history of hypertension, diabetes mellitus type 2, sleep apnea, and iron deficiency anemia. Despite undergoing unnecessarily prolonged iron supplementation for suspected iron deficiency anemia, the patient's complete blood count and peripheral blood smear continued to identify hypochromic microcytic anemia. Ultimately, hemoglobin electrophoresis was performed, and mutations were identified in the hemoglobin beta chain consistent with β-thalassemia minor. Due to its rarity and wide variation in presentation, β-thalassemia may be frequently misdiagnosed. β-thalassemia is a spectrum of disorders ranging from β-thalassemia minor, which may be asymptomatic and incidentally discovered in adulthood, to β-thalassemia major, which may include bone marrow deformities from extramedullary hematopoiesis and require frequent blood transfusions to sustain life. Therefore, patients who present with symptoms of β-thalassemia minor may not be identified until later in life after undergoing decades of ineffective treatment. β-thalassemia is a multifactorial disease with a variety of clinical presentations that can easily be misdiagnosed as other types of anemia. This case highlights the importance of performing thorough laboratory testing and casting a wide net of differential diagnoses when evaluating patients with treatment-resistant anemia. This case calls for further research on the genetic contributions to β-thalassemia as well as improved ways to identify this disorder, particularly in patients who may not have a severe form that is easily diagnosed in early childhood.
PubMed: 38872652
DOI: 10.7759/cureus.60275