Journal of Clinical Medicine May 2024: To investigate the perception of young European otolaryngologists (OTOs), i.e., head and neck surgeons, toward transoral robotic surgery (TORS). : Members of the Young...
: To investigate the perception of young European otolaryngologists (OTOs), i.e., head and neck surgeons, toward transoral robotic surgery (TORS). : Members of the Young Confederation of European Otorhinolaryngology-Head and Neck Surgery and Young Otolaryngologists of International Federation of Otorhinolaryngological Societies were surveyed about TORS perception and practice. : The survey was completed by 120 young OTOS (26%). The most important barriers to TORS were robot availability (73%), cost (69%), and lack of training (37%). The participants believed that the main benefits include better surgical filed view (64%), shorter hospital stay (62%), and better postoperative outcomes (61%) than the conventional approach. Head and neck surgeons considered cT1-T2 oropharyngeal cancers (94%), resection of base of tongue for sleep apnea (86%), or primary unknown cancer (76%) as the most appropriate indications. A total of 67% of TORS surgeons assessed themselves as adequately trained in TORS. : Young European OTOs report positive perception, adoption, and knowledge of TORS. The cost-related unavailability and the lack of training or access are reported to be the most important barriers for the spread of TORS.
PubMed: 38892767
DOI: 10.3390/jcm13113055 -
Respiratory Research Jun 2024Sleep-disordered breathing (SDB) is a major comorbidity in idiopathic pulmonary fibrosis (IPF) and is associated with a poor outcome. There is a lack of knowledge...
Treating sleep-disordered breathing of idiopathic pulmonary fibrosis patients with CPAP and nocturnal oxygen treatment. A pilot study : Sleep-disordered breathing treatment in IPF.
INTRODUCTION
Sleep-disordered breathing (SDB) is a major comorbidity in idiopathic pulmonary fibrosis (IPF) and is associated with a poor outcome. There is a lack of knowledge regarding the impact of SDB treatment on IPF. We assessed at one year: (1) the effect of CPAP and/or nocturnal oxygen therapy on IPF regarding lung function, blood mediators, and quality of life; (2) adherence to SDB treatment and SDB changes.
METHODOLOGY
This is a prospective study of consecutive newly diagnosed IPF patients initiating anti-fibrotic treatment. Lung function, polysomnography, blood tests and quality of life questionnaires were performed at inclusion and after one year. Patients were classified as obstructive sleep apnoea (OSA), central sleep apnoea (CSA), and sleep-sustained hypoxemia (SSH). SDB therapy (CPAP and/or nocturnal oxygen therapy) was initiated if needed.
RESULTS
Fifty patients were enrolled (36% had OSA, 22% CSA, and 12% SSH). CPAP was started in 54% of patients and nocturnal oxygen therapy in 16%. At one-year, polysomnography found improved parameters, though 17% of patients had to add nocturnal oxygen therapy or CPAP, while 33% presented SDB onset at this second polysomnography. CPAP compliance at one year was 6.74 h/night (SD 0.74). After one year, matrix metalloproteinase-1 decreased in OSA and CSA (p = 0.029; p = 0.027), C-reactive protein in OSA (p = 0.045), and surfactant protein D in CSA group (p = 0.074). There was no significant change in lung function.
CONCLUSIONS
Treatment of SBD with CPAP and NOT can be well tolerated with a high compliance. IPF patients may exhibit SDB progression and require periodic re-assessment. Further studies to evaluate the impact of SDB treatment on lung function and serological mediators are needed.
Topics: Humans; Continuous Positive Airway Pressure; Female; Male; Idiopathic Pulmonary Fibrosis; Pilot Projects; Aged; Prospective Studies; Sleep Apnea Syndromes; Oxygen Inhalation Therapy; Middle Aged; Treatment Outcome; Polysomnography; Quality of Life
PubMed: 38890648
DOI: 10.1186/s12931-024-02871-6 -
Applied Microbiology and Biotechnology Jun 2024Obstructive sleep apnea (OSA) can lead to intestinal injury, endotoxemia, and disturbance of intestinal flora. Additionally, as a crucial component of the...
Obstructive sleep apnea (OSA) can lead to intestinal injury, endotoxemia, and disturbance of intestinal flora. Additionally, as a crucial component of the endocannabinoid system, some studies have demonstrated that cannabinoid 1 (CB1) receptors are closely linked to the multiple organ dysfunction triggered by OSA. However, the role of the CB1 receptor in alleviating OSA-induced colon injury remains unclear. Here, through the construction of the OSA classic model, we found that the colon tissue of chronic intermittent hypoxia (CIH)-induced mice exhibited an overexpression of the CB1 receptor. The results of hematoxylin-eosin staining and transmission electron microscopy revealed that inhibition of the CB1 receptor could decrease the gap between the mucosa and muscularis mucosae, alleviate mitochondrial swelling, reduce microvilli shedding, and promote the recovery of tight junctions of CIH-induced mice. Furthermore, CB1 receptor inhibition reduced the levels of metabolic endotoxemia and inflammatory responses, exhibiting significant protective effects on the colon injury caused by CIH. At the molecular level, through western blotting and real-time polymerase chain reaction techniques, we found that inhibiting the CB1 receptor can significantly increase the expression of ZO-1 and Occludin proteins, which are closely related to the maintenance of intestinal mucosal barrier function. Through 16S rRNA high-throughput sequencing and short-chain fatty acid (SCFA) determination, we found that inhibition of the CB1 receptor increased the diversity of the microbial flora and controlled the makeup of intestinal flora. Moreover, butyric acid concentration and the amount of SCFA-producing bacteria, such as Ruminococcaceae and Lachnospiraceae, were both markedly elevated by CB1 receptor inhibition. The results of the spearman correlation study indicated that Lachnospiraceae showed a positive association with both ZO-1 and Occludin but was negatively correlated with the colon CB1 receptor, IL-1β, and TNF-α. According to this study, we found that inhibiting CB1 receptor can improve CIH-induced colon injury by regulating gut microbiota, reducing mucosal damage and promoting tight junction recovery. KEY POINTS: •CIH leads to overexpression of CB1 receptor in colon tissue. •CIH causes intestinal flora disorder, intestinal mucosal damage, and disruption of tight junctions. •Inhibition of CB1 receptor can alleviate the colon injury caused by CIH through regulating the gut microbiota, reducing mucosal injury, and promoting tight junction recovery.
Topics: Animals; Receptor, Cannabinoid, CB1; Mice; Disease Models, Animal; Colon; Male; Intestinal Mucosa; Hypoxia; Mice, Inbred C57BL; Zonula Occludens-1 Protein; Occludin; Gastrointestinal Microbiome; Tight Junctions
PubMed: 38888634
DOI: 10.1007/s00253-024-13216-0 -
Laryngoscope Investigative... Jun 2024The course of sedation during drug-induced sleep endoscopy (DISE) depends on the application pattern of the sedative drug. The depth of sedation should imitate light and...
OBJECTIVE
The course of sedation during drug-induced sleep endoscopy (DISE) depends on the application pattern of the sedative drug. The depth of sedation should imitate light and deep sleep as well. Moreover, there should be as many breathing cycles as possible available for observation during light and deep sedation. The aim of the study was to evaluate different rates of propofol application with respect to the achieved depth and length of the course of sedation.
METHODS
Sixty-three consecutive patients with obstructive sleep apnea and/or snoring undergoing DISE were randomly sedated by propofol perfusion at seven different application patterns: 14, 16, 18, 19, 20, 22 mg/kg/h (0.233, 0.267, 0.3, 0.317, 0.333, 0.367 mg/kg/min) per perfusor and individual bolus application 10 mg each. Sedation depth was monitored by BiSpectral Index™ (BIS). The influence of baseline parameters and the courses of sedation were analyzed.
RESULTS
The application rate was the only factor that influenced the depth of sedation. Basic parameters (gender, age, body mass index, apnea-hypopnea index) had no influence on the depth of sedation. The sedation depth was dependent on the rate of propofol application. Regimes at 14 and 16 mg/kg/h as well as bolus application did not reach BIS levels below 50 representing deep sleep. Propofol doses of more than 20 mg/kg/h led to rapid decreases of sedation levels below deep sleep niveau. Propofol rates between 18 and 20 mg/kg/h enable BIS levels below 50 representing deep sleep and providing enough breathing cycles for observation.
CONCLUSION
Lower application rates of propofol provide slower courses of sedation and shallower depths of sedation. A rate of 14 mg/kg/h might be appropriate to reach a sedation plateau at light sleep. A rate of 18 mg/kg/h leads to a sedation, corresponding to deep sleep. The combination of both rates might be a suitable pattern for performing sedation-controlled DISE.
LEVEL OF EVIDENCE
2: Randomized trial.
PubMed: 38887705
DOI: 10.1002/lio2.1258 -
Cureus May 2024Transnasal humidified rapid-insufflation ventilator exchange (THRIVE) has been reported to have better efficacy during anesthesia induction compared to conventional mask...
Prevention of Oxygen Desaturation in a Patient With Previous Experience of Severe Hypoxia in Modified Electroconvulsive Therapy by Transnasal Humidified Rapid-Insufflation Ventilator Exchange: A Case Report.
Transnasal humidified rapid-insufflation ventilator exchange (THRIVE) has been reported to have better efficacy during anesthesia induction compared to conventional mask ventilation, including improved oxygenation and prolonged safe apnea time. This study reports on the effectiveness of the THRIVE system during modified electroconvulsive therapy (mECT) for a patient experiencing severe hypoxia. A 78-year-old female patient with bipolar disorder received maintenance mECT every four weeks. She previously experienced a significant hypoxic event, with oxygen saturation (SpO) dropping to 50% following electrical stimulation. In response, we employed the THRIVE system, designed to deliver high-flow, 100% oxygen, thereby extending apnea tolerance. The implementation of THRIVE ensured a stable oxygen supply, maintaining oxygen saturation levels above 95% throughout the mECT procedure. THRIVE is useful for treating hypoxia that occurs due to the unavoidable lack of ventilation during mECT.
PubMed: 38887347
DOI: 10.7759/cureus.60564 -
Frontiers in Endocrinology 2024This study aimed to distinguish between healthy controls and patients with OSAHS regarding homocysteine (HCY) levels and investigate how individuals with OSAHS respond... (Meta-Analysis)
Meta-Analysis
OBJECTIVE
This study aimed to distinguish between healthy controls and patients with OSAHS regarding homocysteine (HCY) levels and investigate how individuals with OSAHS respond to continuous positive airway pressure ventilation (CPAP) in terms of serum and plasma HCY levels.
METHODS
To ascertain published articles about OSAHS, an exhaustive search was performed across medical databases, encompassing PubMed, Web of Science, EMBASE, CNKI, and Cochrane Library, until January 2, 2024. This study reviewed the literature regarding HCY levels in individuals with OSAHS and control groups, HCY levels under pre- and post-CPAP treatment, the Pearson/Spearman correlation coefficients between HCY levels and apnea-hypopnea index (AHI), and the hazard ratio (HR) of HCY levels concerning the occurrence of major adverse cerebrocardiovascular events (MACCEs) in patients with OSAHS. Meta-analyses were performed using weighted mean difference (WMD), correlation coefficients, and HR as effect variables. The statistical analysis was conducted using the R 4.1.2 and STATA 11.0 software packages.
RESULTS
In total, 33 articles were selected for the final analysis. The OSAHS group exhibited significantly higher serum/plasma HCY levels than the control group (WMD = 4.25 μmol/L, 95% CI: 2.60-5.91, < 0.001), particularly among individuals with moderate and severe OSAHS. Additionally, subgroup analysis using mean age, ethnicity, mean body mass index, and study design type unveiled significantly elevated levels of HCY in the serum/plasma of the OSAHS group compared to the control group. CPAP treatment can significantly decrease serum/plasma HCY levels in patients with OSAHS. Moreover, elevated HCY levels in individuals with OSAHS could be one of the risk factors for MACCEs (adjusted HR = 1.68, 95% CI = 1.10-2.58, = 0.017). AHI scores show a positive correlation with serum/plasma HCY levels.
CONCLUSION
Patients with OSAHS had elevated serum/plasma HCY levels compared to healthy controls; however, CPAP therapy dramatically decreased HCY levels in patients with OSAHS. In patients with OSAHS, elevated HCY levels were linked with an increased risk of MACCEs, and HCY was positively connected with AHI values. HCY levels may serve as a useful clinical indicator for determining the severity and efficacy of OSAHS treatments.
SYSTEMATIC REVIEW REGISTRATION
https://www.crd.york.ac.uk/prospero/, identifier CRD42024498806.
Topics: Humans; Sleep Apnea, Obstructive; Homocysteine; Continuous Positive Airway Pressure
PubMed: 38887264
DOI: 10.3389/fendo.2024.1378293 -
Chest Jun 2024The healthy adherer effect (HAE) has gained increasing attention as potential source of bias in observational studies examining the association of positive airway...
BACKGROUND
The healthy adherer effect (HAE) has gained increasing attention as potential source of bias in observational studies examining the association of positive airway pressure (PAP) adherence with health outcomes in obstructive sleep apnea (OSA).
RESEARCH QUESTION
Is adherence to PAP associated with healthy behaviors and healthcare resource use prior to device prescription?
METHODS
Data from the IRSR Pays de la Loire Sleep Cohort were linked to health administrative data to identify proxies of heathy behaviors (HB) including adherence to cardiovascular (CV) drugs (medication possession ratio, [MPR]), cancer screening tests, influenza vaccination, alcohol and smoking consumption, and drowsiness-related road accidents during the two years preceding PAP onset in OSA patients. Multivariable regression analyses were conducted to evaluate the association of HB with subsequent PAP adherence. Healthcare resource use was evaluated according to subsequent PAP adherence.
FINDINGS
We included 2,836 patients who had started PAP therapy between 2012 and 2018 (65% of whom were PAP adherent with mean daily use ≥4h/night). Being adherent to CV active drugs (MPR≥80%) and non-smoker were associated with a higher likelihood of PAP adherence (odds ratio, OR [95% confidence interval]: 1.43 [1.15; 1.77] and 1.37 [1.10; 1.71] respectively). Patients with no history of drowsiness-related road accidents were more likely to continue PAP (OR: 1.39 [1.04; 1.87]). PAP adherent patients used less healthcare resources 2 years before PAP initiation, than non-adherents (mean number of outpatient consultations: 19.0 vs 17.2, P=.003; hospitalization days: 5.7 vs 5.0, P=.04; emergency room visit: 30.7 vs 24.0% P=.0002).
INTERPRETATION
Patients who adhere to PAP therapy of OSA were more health seeking and less healthcare users prior to device initiation than non-adherent patients. Until the HAE associated with PAP adherence is better understood, caution is warranted when interpreting the association of PAP adherence with CV health outcomes and healthcare resource use in non-randomized cohorts.
PubMed: 38885897
DOI: 10.1016/j.chest.2024.05.024 -
Sleep Medicine Jun 2024This research work was performed: (1) To assess the accessibility of in-laboratory polysomnography for individuals with spinal cord injury (SCI); (2) to evaluate the...
OBJECTIVES
This research work was performed: (1) To assess the accessibility of in-laboratory polysomnography for individuals with spinal cord injury (SCI); (2) to evaluate the validity of four screening questionnaires for sleep-related breathing disorders (SRBDs); and (3) to assess the association between anthropometric features and apnea-hypopnea index (AHI).
METHODS
An Environmental scan (E-scan) was performed in the province of Ontario, where all sleep clinics were invited to complete the E-scan survey. Furthermore, a cross-sectional study was performed at a rehabilitation hospital (Canada), where consecutive adults with subacute/chronic (>1 month) SCI were recruited. Using a home-based screening sleep test (HBSST), the validity of the Berlin, STOP, Medical Outcomes Study Sleep Scale [MOS-SS], and STOP-Bang screening questionnaires was assessed. The association between AHI and three features (i.e., neck circumference, body mass index [BMI] and oropharynx opening as assessed using the Modified Mallampati classification [MMC]) was evaluated.
RESULTS
According to the E-scan, access to polysomnography is limited for the SCI population in Ontario. Of the 28 participants with SCI (11 females, 17 males; mean age: 54.9 years) included in the cross-sectional study, 32.1 % were diagnosed with moderate-to-severe SRBD. The performance of the questionnaires was considered insufficient for screening of individuals living with SCI. AHI was not associated with neck circumference, BMI, or MMC.
CONCLUSIONS
Those results suggest that the use of a HBSST could overcome the barriers for individuals with SCI to access diagnostic testing of SRBDs. The use of screening questionnaires and risk assessment for SRBDs in the SCI population is unreliable.
PubMed: 38885542
DOI: 10.1016/j.sleep.2024.06.011 -
Frontiers in Pediatrics 2024Exchange transfusion therapy is a complex and invasive procedure with a high risk coefficient. This method involves replacing the entire blood of a child with fresh...
BACKGROUND
Exchange transfusion therapy is a complex and invasive procedure with a high risk coefficient. This method involves replacing the entire blood of a child with fresh blood with double circulating blood volume in a short period, typically in 1-2 h. This procedure can cause the body's internal environment to be unstable, which can put newborns under a lot of stress. This stress can lead to many, including abnormal laboratory biochemical examination, low or high blood pressure, and apnea. There is also the possibility of secondary infection and, in severe cases, cardiac arrest. This study investigated the effects of Humidified high-flow nasal cannula (HHFNC) ventilation on hemodynamic stability and oxygenation during exchange transfusion in neonates. Furthermore, the effects on brain metabolism and salivary cortisol during exchange transfusion were also analyzed.
METHODS
In this study, the control group consisted of 45 cases of children who underwent simple blood exchange between 1 May 2017, and 31 December 2019 control group. The observation group consisted of 33 cases of children who underwent blood exchange under HHFNC support between 1 January 2020, and 30 April 2022. The study compared various physiological parameters between the control and the observation group. These included blood gas analysis, pulmonary artery pressure, ejection fraction, invasive mean arterial pressure, heart rate, cerebral oxygenation, intestinal oxygenation, renal oxygenation, and duration of blood exchange. Furthermore, the study also compared the changes in brain metabolic and salivary cortisol indicators between the two groups of children.
RESULTS
The results did not reveal any significant difference in PH, PaO and duration of blood exchange between the control and the observation group. However, the observation group's invasive mean arterial pressure, ejection fraction, cerebral oxygenation, intestinal oxygenation, and renal oxygenation were higher than those of the control group. Furthermore, compared with the control group, the pulmonary artery pressure, heart rate, and PaCO were lower in the observation group. There was a statistically significant difference between the two groups of children in the relevant clinical indicators (total bilirubin, hemoglobin, SPO, etc.) after exchange transfusion. After 1 h of blood exchange and after blood exchange, the salivary cortisol levels of the observation group were lower than the control group. The difference was statistically significant. The NAA/Cho and Cho/Cr values of the two groups of children were also significantly different.
CONCLUSION
During blood exchange, unstable hemodynamics substantially impact organ oxygenation. The results of this study suggest that HHFNC and specific ventilation pressure support can improve the respiratory rate and help maintain blood flow stability and organ oxygenation. This technique can also reduce adverse reactions caused by blood exchange, minimizing patient stress and reducing the impact on brain metabolism.
PubMed: 38884105
DOI: 10.3389/fped.2024.1381808 -
MedRxiv : the Preprint Server For... Jun 2024Atrial fibrillation (AF) is often asymptomatic and thus under-observed. Given the high risks of stroke and heart failure among patients with AF, early prediction and...
BACKGROUND
Atrial fibrillation (AF) is often asymptomatic and thus under-observed. Given the high risks of stroke and heart failure among patients with AF, early prediction and effective management are crucial. Importantly, obstructive sleep apnea is highly prevalent among AF patients (60-90%); therefore, electrocardiogram (ECG) analysis from polysomnography (PSG), a standard diagnostic tool for subjects with suspected sleep apnea, presents a unique opportunity for the early prediction of AF. Our goal is to identify individuals at a high risk of developing AF in the future from a single-lead ECG recorded during standard PSGs.
METHODS
We analyzed 18,782 single-lead ECG recordings from 13,609 subjects at Massachusetts General Hospital, identifying AF presence using ICD-9/10 codes in medical records. Our dataset comprises 15,913 recordings without a medical record for AF and 2,056 recordings from patients who were first diagnosed with AF between 1 day to 15 years after the PSG recording. The PSG data were partitioned into training, validation, and test cohorts. In the first phase, a signal quality index (SQI) was calculated in 30-second windows and those with SQI 0.95 were removed. From each remaining window, 150 hand-crafted features were extracted from time, frequency, time-frequency domains, and phase-space reconstructions of the ECG. A compilation of 12 statistical features summarized these window-specific features per recording, resulting in 1,800 features. We then updated a pre-trained deep neural network and data from the PhysioNet Challenge 2021 using transfer-learning to discriminate between recordings with and without AF using the same Challenge data. The model was applied to the PSG ECGs in 16-second windows to generate the probability of AF for each window. From the resultant probability sequence, 13 statistical features were extracted. Subsequently, we trained a shallow neural network to predict future AF using the extracted ECG and probability features.
RESULTS
On the test set, our model demonstrated a sensitivity of 0.67, specificity of 0.81, and precision of 0.3 for predicting AF. Further, survival analysis for AF outcomes, using the log-rank test, revealed a hazard ratio of 8.36 (p-value of 1.93 × 10 ).
CONCLUSIONS
Our proposed ECG analysis method, utilizing overnight PSG data, shows promise in AF prediction despite a modest precision indicating the presence of false positive cases. This approach could potentially enable low-cost screening and proactive treatment for high-risk patients. Ongoing refinement, such as integrating additional physiological parameters could significantly reduce false positives, enhancing its clinical utility and accuracy.
PubMed: 38883765
DOI: 10.1101/2024.06.04.24308444