Cureus Mar 2024Background When metals used in orthodontic materials are exposed to the oral environment, teeth, and gingivae over an extended period of time, they may gradually...
Background When metals used in orthodontic materials are exposed to the oral environment, teeth, and gingivae over an extended period of time, they may gradually deteriorate. As a result, the patient is exposed to higher concentrations of metals and metal ions than what they would be exposed to through food and other sources. The goal of the current in vitro experiment was to evaluate and contrast the metal ion release from orthodontic archwires made of titanium-molybdenum alloy (TMA) and nickel-titanium (NiTi). Methods For 90 days, 20 orthodontic archwires in each group were immersed in 50 milliliters of simulated saliva using different containers. Atomic Absorption Spectrometry (AAS) (Shimadzu Corporation, Kyoto, Japan) was used to assess and compare metal ion emission. The unit of measurement is parts per million (PPM). Results The findings indicated that the discharge of nickel metal from the NiTi archwire (Group A) was much higher than that from the TMA archwire (Group B), with a statistical significance level of p < 0.001. It was discovered that Group B's release of titanium was statistically significantly (p < 0.05) higher than Group A's titanium release, which did not include the release of any other metals. Conclusion The study findings indicated that the amounts of metal ions released from the orthodontic archwires made of titanium molybdenum and nickel-titanium alloy were within safety limits.
PubMed: 38646368
DOI: 10.7759/cureus.56595 -
PloS One 2024Marginal fit significantly impacts the long-term success of dental restorations. Different pattern fabrication methods, including hand-waxing, milling, or 3D printing,...
BACKGROUND
Marginal fit significantly impacts the long-term success of dental restorations. Different pattern fabrication methods, including hand-waxing, milling, or 3D printing, may affect restorations accuracy. The effect of porcelain firing cycles on the marginal fit of metal-ceramic restorations remains controversial, with conflicting findings across studies.
PURPOSE
The aim was to evaluate the potential effects of multiple porcelain firings (3, 5, 7 cycles) as well as pattern fabrication method (conventional hand-waxing, milling, and 3D printing) on the marginal adaptation of 3-unit implant-supported metal-ceramic fixed partial dentures. It was hypothesized that neither the wax pattern fabrication method nor repeated ceramic firings would significantly affect the marginal adaptation of metal-ceramic crowns.
METHODS
In this in-vitro study, 30 Cobalt-Chromium alloy frameworks were fabricated based on pattern made through three techniques: conventional hand-waxing, CAD-CAM milling, and CAD-CAM 3D printing (n = 10 per group). Sixteen locations were marked on each abutment to measure the vertical marginal gap at four stages: before porcelain veneering and after 3, 5, and 7 firing cycles. The vertical marginal gap was measured using direct microscopic technique at ×80 magnification. Mean vertical marginal gap values were calculated and two-way ANOVA and Tukey's post hoc tests were used for inter-group comparisons (α = 0.05).
RESULTS
The 3D printing group showed significantly lower (P<0.001) mean vertical marginal gaps (60-76 μm) compared to the milling (77-115 μm) and conventional hand-waxing (102-110 μm) groups. The milling group exhibited a significant vertical gap increase after 3 firing cycles (P<0.001); while the conventional (P = 0.429) and 3D printing groups (P = 0.501) showed no significant changes after 7 firing cycles. Notably, the vertical marginal gap in all groups remained below the clinically acceptable threshold of 120 μm.
CONCLUSION
CAD-CAM 3D printing provided superior marginal fit compared to CAD-CAM milling and conventional hand-wax pattern fabrication methods. The impact of porcelain firing on the mean marginal gap was significant only in the milling group. All three fabrication techniques yielded clinically acceptable vertical marginal adaptation after repeated firings. Additive manufacturing holds promise to produce precise implant-supported prostheses.
Topics: Dental Porcelain; Computer-Aided Design; Printing, Three-Dimensional; Denture, Partial, Fixed; Metal Ceramic Alloys; Dental Prosthesis Design; Crowns
PubMed: 38625846
DOI: 10.1371/journal.pone.0301799 -
PeerJ 2024Juniper () is a common forest tree species in Saudi Arabia. The decline in many populations of . in Saudi Arabia is mainly due to seed dormancy and loss of natural...
PURPOSE
Juniper () is a common forest tree species in Saudi Arabia. The decline in many populations of . in Saudi Arabia is mainly due to seed dormancy and loss of natural regeneration. This study assessed the effects of chemical and hormonal treatments on seed germination and seedling growth in juniper plants.
METHODS
The seeds were subjected to either chemical scarification with 90% sulfuric acid and 20% acetic acid for 6 min or hormonal treatment by seed soaking in two concentrations (50 and 100 ppm) of three growth regulators, namely, indole acetic acid (IAA), gibberellins (GA), and kinetin, for 72 h. A control group without any seed treatment was also prepared. The experiments were performed in an incubator maintained at room temperature and under a light and dark period of 12 h for 6 w. The germinated seeds for each treatment were counted and removed from the dishes. The selected germinated seeds from different treatments were planted in a greenhouse and irrigated with tap water for another 6 weeks. The hormone-treated seedlings were sprayed with their corresponding hormone concentrations 1 w after planting.
RESULTS
The highest percentage of seed germination was significantly recorded after seed soaking in 50 ppm GA, whereas treatment with IAA (100 ppm) resulted in the best seedling growth. Seedlings treated with the three phytohormones showed a significant increase in photosynthetic pigments, total soluble sugars, proteins, percentage of oil, IAA, GA, and kinetin contents of juniper seedlings compared with the control value, whereas abscisic acid content was decreased compared with chemical treatments.
CONCLUSION
The investigated different treatments had an effective role in breaking seed dormancy and improving seedling growth of . , which is facing a notable decline in its population worldwide. Moreover, such an effect was more pronounced in the three phytohormones that succeeded in breaking dormancy and growth of the plant than in the other treatments.
Topics: Seedlings; Juniperus; Germination; Plant Growth Regulators; Kinetin; Seeds; Hormones; Dental Porcelain; Titanium; Metal Ceramic Alloys
PubMed: 38618572
DOI: 10.7717/peerj.17236 -
Journal of Dental Sciences Apr 2024Temperature-dependent phase compositional changes influence the mechanical properties of heat-treated nickel-titanium (NiTi) rotary instruments. This study evaluated the...
BACKGROUND/PURPOSE
Temperature-dependent phase compositional changes influence the mechanical properties of heat-treated nickel-titanium (NiTi) rotary instruments. This study evaluated the phase composition, bending properties, and cyclic fatigue resistance of HyFlex EDM NiTi rotary instruments against differently heat-treated and non-heat-treated NiTi instruments at body temperature (BT).
MATERIALS AND METHODS
HyFlex EDM OneFile (EDM) instruments, heat-treated HyFlex CM (CM) and Twisted File (TF) instruments, and non-heat-treated K3 instruments (size #25/.08) were subjected to differential scanning calorimetry, and the martensitic, R-phase, and reverse transformation starting and finishing temperatures were determined. A cantilever bending test and a cyclic fatigue test were conducted at BT (37 °C ± 1.0 °C), and the bending load and number of cycles to failure (NCF) were recorded. Statistical analysis was performed using Kruskal-Wallis and Mann-Whitney U tests (α = 0.05).
RESULTS
TF and K3 had reverse transformation finishing temperatures lower than BT, while those for EDM and CM were higher than BT. The bending loads at a 0.5 mm deflection were in the order of EDM < TF < CM < K3 ( < 0.05), and those at a 2.0 mm deflection were EDM < CM and TF < K3 (P < 0.05). EDM had the highest NCF among the four instruments ( < 0.05).
CONCLUSION
The EDM instrument had a reverse transformation finishing temperature higher than BT indicating its martensite/R-phase composition at BT. The EDM instrument had superior flexibility and greater resistance to cyclic fatigue than the CM, TF, and K3 instruments at BT.
PubMed: 38618130
DOI: 10.1016/j.jds.2023.07.039 -
Materials (Basel, Switzerland) Apr 2024A new Mg-Zn-Zr-Ca alloy in a powder state, intended to be used for custom shaped implants, was obtained via a mechanical alloying method from pure elemental powder....
A new Mg-Zn-Zr-Ca alloy in a powder state, intended to be used for custom shaped implants, was obtained via a mechanical alloying method from pure elemental powder. Further, the obtained powder alloy was processed by a PBF-LB/M (powder bed fusion with laser beam/of metal) procedure to obtain additive manufactured samples for small biodegradable implants. A series of microstructural, mechanical and corrosion analyses were performed. The SEM (scanning electron microscopy) analysis of the powder alloy revealed a good dimensional homogeneity, with a uniform colour, no agglutination and almost rounded particles, suitable for the powder bed fusion procedure. Further, the PBF-LB/M samples revealed a robust and unbreakable morphology, with a suitable porosity (that can reproduce that of cortical bone) and without an undesirable balling effect. The tested Young's modulus of the PBF-LB/M samples, which was 42 GPa, is close to that of cortical bone, 30 GPa. The corrosion tests that were performed in PBS (Phosphate-buffered saline) solution, with three different pH values, show that the corrosion parameters have a satisfactory evolution comparative to the commercial ZK 60 alloy.
PubMed: 38612195
DOI: 10.3390/ma17071682 -
Materials (Basel, Switzerland) Apr 2024In this study, a series of Ti-5Cr-xNb alloys with varying Nb content (ranging from 1 to 40 wt.%) were investigated to assess their suitability as implant materials....
In this study, a series of Ti-5Cr-xNb alloys with varying Nb content (ranging from 1 to 40 wt.%) were investigated to assess their suitability as implant materials. Comprehensive analyses were conducted, including phase analysis, microscopy examination, mechanical testing, and corrosion resistance evaluation. The results revealed significant structural alterations attributed to Nb addition, notably suppressing the formation of the ω phase and transitioning from α' + β + ω to single β phase structures. Moreover, the incorporation of Nb markedly improved the alloys' plastic deformation ability and reduced their elastic modulus. In particular, the Ti-5Cr-25Nb alloy demonstrated high values in corrosion potential and polarization resistance, signifying exceptional corrosion resistance. This alloy also displayed high bending strength (approximately 1500 MPa), a low elastic modulus (approximately 80 GPa), and outstanding elastic recovery and plastic deformation capabilities. These aggregate outcomes indicate the promising potential of the β-phase Ti-5Cr-25Nb alloy for applications in orthopedic and dental implants.
PubMed: 38612179
DOI: 10.3390/ma17071667 -
Journal of Clinical Medicine Apr 2024Fiber-reinforced composites (FRCs) have been proposed as an alternative to traditional metal alloys for the realization of frameworks in full-arch implant-supported...
Fiber-reinforced composites (FRCs) have been proposed as an alternative to traditional metal alloys for the realization of frameworks in full-arch implant-supported prostheses. The aim of the present in vitro study was to evaluate the deflection under load of seven prostheses endowed with frameworks made of different materials, including different types of fiber-reinforced composites (FRCs). A master cast with four implant analogues in correspondence with the two lateral incisors and the two first molars was used to create full-arch fixed prostheses with the same shape and different materials. Prostheses were made of the following different materials (framework+veneering material): gold alloy+resin (Au+R), titanium+resin (Ti+R), FRC with multidirectional carbon fibers+resin (ICFRC+AR), FRC with unidirectional carbon fibers+composite (UCFRC+C), FRC with glass fibers+resin (GFRC+AR), FRC with glass fibers+composite (GFRC+C), and resin (R, fully acrylic prosthesis). Flexural tests were conducted using a Zwick/Roell Z 0.5 machine, and the deflection of the lower surface of the prosthesis was measured in order to obtain load/deflection graphs. Greater rigidity and less deflection were recorded for UCFRC+C and GFRC+C, followed by Ti+R and Au+R. The greatest deformations were observed for resin alone, ICFRC+R, and GFRC+R. The results were slightly different in the incisal region, probably due to the greater amount of veneering material in this area. When used to realize full-arch frameworks, Au and Ti allow for predictable mechanical behavior with gradual deformations with increasing load. UCFRC also demonstrated good outcomes and less deflection than ICFRCs when loaded. The GFRC full-arch framework may be a valid alternative, although it showed greater deflections. Further studies are needed in order to evaluate how different prosthesis designs and material thicknesses might affect the outcomes.
PubMed: 38610826
DOI: 10.3390/jcm13072060 -
Nanomaterials (Basel, Switzerland) Mar 2024Titanium and its alloys are extensively applied in artificial tooth roots because of their excellent corrosion resistance, high specific strength, and low elastic...
Titanium and its alloys are extensively applied in artificial tooth roots because of their excellent corrosion resistance, high specific strength, and low elastic modulus. However, because of their biological inertness, their surface needs to be modified to improve the osteointegration of titanium implants. The preparation of biologically active calcium-phosphorus coatings on the surface of an implant is one effective method for enhancing the likelihood of bone integration. In this study, osteoinductive peptides were extracted from oyster shells by using acetic acid. Two peptide-containing hydroxyapatite (HA) composite coatings were then prepared: one coating was prepared by hydrothermally synthesizing an HA coating in the presence of peptides (HA/P/M), and the other coating was prepared by hydrothermally synthesizing HA and then immersing the hydrothermally synthesized HA in a peptide solution (HA/P/S). Characterization results indicated that the composite HA coatings containing oyster shell-based peptides were successfully prepared on the alkali-treated pure titanium surfaces. The HA/P/M and HA/P/S composite coatings were found to exhibit excellent hydrophilicity. Protein adsorption tests confirmed that the HA/P/M and HA/P/S coatings had an approximately 2.3 times higher concentration of adsorbed proteins than the pure HA coating.
PubMed: 38607112
DOI: 10.3390/nano14070577 -
Journal of Pharmacy & Bioallied Sciences Feb 2024Surface roughness of the crowns is dependent on the pattern material used for the making as well as the procedure of investing. The study was aimed to examine the impact...
INTRODUCTION
Surface roughness of the crowns is dependent on the pattern material used for the making as well as the procedure of investing. The study was aimed to examine the impact of various pattern materials and investment procedures on the surface roughness of nickel-chromium alloy raw castings.
MATERIALS AND METHODS
An study was piloted at a tertiary care hospital. Eighty samples of inlay wax and pattern resin were divided equally. They were invested in phosphate-bonded investment material and kept under normal atmospheric pressure as well as invested under a pressure of 3 bars. The surface roughness was calculated with a Profilometer. The values obtained were compared using statistical tools keeping < 0.05 as significant.
RESULTS
Lowest surface roughness was seen for the wax pattern invested under positive pressure. While the highest was seen for the resin patterns invested at room pressure. A significant variance between the wax 1 and wax 2 ( < 0.01); as well as between the wax 2 vs. Resin 2 specimens ( < 0.01) was noted.
CONCLUSIONS
Wax patterns can be suggested as the material and method of choice because they showed the least amount of surface roughness when placed under pressure. Resin patterns when invested under pressure can also be suggested as an alternate as they also exhibited similar surface roughness as that of the wax.
PubMed: 38595557
DOI: 10.4103/jpbs.jpbs_445_23 -
Journal of Pharmacy & Bioallied Sciences Feb 2024The esthetic during the various orthodontic treatments has led to the invention of the brackets. When different ceramic brackets and archwires are used, the different...
INTRODUCTION
The esthetic during the various orthodontic treatments has led to the invention of the brackets. When different ceramic brackets and archwires are used, the different frictional forces may result in the different outputs. Hence, in the present study, we evaluated and compared the frictional resistance between eight standard monocrystalline ceramic bracket models and each of the archwires of four different alloys.
MATERIALS AND METHODS
Frictional force was tested using Instron testing machine, , for eight types of monocrystalline ceramic bracket, and four types of archwires beta-titanium, NiTi, copper-nickel-titanium, and stainless steel statistical analysis were done using various tools, and significance value of <0.05 was considered.
RESULTS
Ormco and AO (Radiance) monocrystalline ceramic brackets created lesser frictional resistance than other monocrystalline ceramic brackets. Stainless steel archwire generates lesser static friction. Beta-titanium archwire created higher static friction. A 0.017 × 0.025 inch stainless steel archwire generates lesser static friction to 0.019 × 0.025 inch TMA.
CONCLUSION
It can be concluded that Ormco and AO (Radiance) monocrystalline ceramic brackets, with stainless steel archwires and of size 0.017 × 0.025 inch, can generate better forces when used for the orthodontic tooth movements.
PubMed: 38595439
DOI: 10.4103/jpbs.jpbs_572_23