Cureus May 2024Atlantoaxial dislocations (AAD) are a diverse set of C1-C2 rotatory subluxations that include the inferior and superior axial facet articulations. C1-C2 segments are...
Atlantoaxial dislocations (AAD) are a diverse set of C1-C2 rotatory subluxations that include the inferior and superior axial facet articulations. C1-C2 segments are both covered by cranial-cervical ligaments, indicating that AAD would damage both joints. Whenever the posterior elements are missing or impaired, lateral mass screw fixation has replaced alternative posterior cervical fixation procedures as the preferred treatment for securing the sub-axial cervical spine. An increase in muscle tone, hyperreflexia, pathological reflexes, digit/hand clumsiness, and gait deviations caused by spinal cord compression at the cervical level are the most common clinical features. A 23-year-old female patient came with the chief complaint of weakness, tingling sensation, and numbness in both upper and lower limbs along with imbalance while walking. She had a history of falls which was managed conservatively. As the symptoms progressed, an MRI, a CT scan, and an X-ray of the neck were done to rule out the level of injury which revealed AAD, and the patient was operated on for C1-C2 lateral mass fixation. Post-operatively, the patient was referred to the physiotherapy department for further management. The patient's quality of life and daily functioning were positively affected after undergoing early intervention as measured by the Functional Independence Measure, Neck Disability Index, Berg Balance Scale, and Dynamic Gait Index.
PubMed: 38910634
DOI: 10.7759/cureus.60913 -
Bone & Joint Open Jun 2024In metal-on-metal (MoM) hip arthroplasties and resurfacings, mechanically induced corrosion can lead to elevated serum metal ions, a local inflammatory response, and...
AIMS
In metal-on-metal (MoM) hip arthroplasties and resurfacings, mechanically induced corrosion can lead to elevated serum metal ions, a local inflammatory response, and formation of pseudotumours, ultimately requiring revision. The size and diametral clearance of anatomical (ADM) and modular (MDM) dual-mobility polyethylene bearings match those of Birmingham hip MoM components. If the acetabular component is satisfactorily positioned, well integrated into the bone, and has no surface damage, this presents the opportunity for revision with exchange of the metal head for ADM/MDM polyethylene bearings without removal of the acetabular component.
METHODS
Between 2012 and 2020, across two centres, 94 patients underwent revision of Birmingham MoM hip arthroplasties or resurfacings. Mean age was 65.5 years (33 to 87). In 53 patients (56.4%), the acetabular component was retained and dual-mobility bearings were used (DM); in 41 (43.6%) the acetabulum was revised (AR). Patients underwent follow-up of minimum two-years (mean 4.6 (2.1 to 8.5) years).
RESULTS
In the DM group, two (3.8%) patients underwent further surgery: one (1.9%) for dislocation and one (1.9%) for infection. In the AR group, four (9.8%) underwent further procedures: two (4.9%) for loosening of the acetabular component and two (4.9%) following dislocations. There were no other dislocations in either group. In the DM group, operating time (68.4 vs 101.5 mins, p < 0.001), postoperative drop in haemoglobin (16.6 vs 27.8 g/L, p < 0.001), and length of stay (1.8 vs 2.4 days, p < 0.001) were significantly lower. There was a significant reduction in serum metal ions postoperatively in both groups (p < 0.001), although there was no difference between groups for this reduction (p = 0.674 (cobalt); p = 0.186 (chromium)).
CONCLUSION
In selected patients with Birmingham MoM hips, where the acetabular component is well-fixed and in a satisfactory position with no surface damage, the metal head can be exchanged for polyethylene ADM/MDM bearings with retention of the acetabular prosthesis. This presents significant benefits, with a shorter procedure and a lower risk of complications.
PubMed: 38910515
DOI: 10.1302/2633-1462.56.BJO-2023-0165.R1 -
The Journal of Arthroplasty Jun 2024This study reports the minimum 10 year results of total hip arthroplasty (THA) performed using a monoblock acetabular component with a large-diameter head (LDH)...
AIMS
This study reports the minimum 10 year results of total hip arthroplasty (THA) performed using a monoblock acetabular component with a large-diameter head (LDH) ceramic-on-ceramic (CoC) bearing.
METHODS
Of the 276 THAs included in this study, 237 (85%) were available for review at a mean of 10.5 years (range, 10 to 12) postoperatively. There were eleven deaths that occurred during the follow-up. Reoperations, implant revisions, adverse events, clinical outcomes, radiographic evaluation, and whole blood metal ion levels were assessed at the last follow-up.
RESULTS
After a minimum of 10 years, implant survivorship was 98.7%. There were three revisions (1.3%): one for insufficient acetabular cup primary fixation, one traumatic periprosthetic acetabular fracture, and one probable deep chronic infection. No dislocation or ceramic implant fracture was observed. The mean University of California at Los Angeles (UCLA) activity score, Western Ontario and McMaster Universities Osteoarthritis Index score, and Forgotten Joint Score were 5.6 (2 to 10), 90.1 (9 to 100), and 79.2 (4 to 100), respectively. In the 10 years following implantation, at least 43% of patients reported hearing a squeaking noise from the prosthesis. All patients who had squeaking hips were satisfied with the surgery. The mean titanium level was 2.2 μg/L (1.1 to 5.6). No progressive radiolucent lines, osteolysis, or implant loosening signs were observed at the last radiographic evaluation.
CONCLUSION
A LDH CoC THA provides outstanding long-term (minimum 10 year) implant survivorship with unrestricted activity while avoiding implant impingement, liner fracture, and hip instability. Functional outcomes, satisfaction, and joint perception were excellent. Although the incidence of squeaking was high, it did not affect patient satisfaction or function. The systemic titanium levels were low, related to unavoidable passive corrosion of implant surfaces, and did not reveal any indirect signs of trunnionosis.
PubMed: 38909852
DOI: 10.1016/j.arth.2024.06.045 -
Hand Surgery & Rehabilitation Jun 2024This study proposes a deep-learning algorithm to automatically detect perilunate dislocation on anteroposterior wrist radiographs. A total of 374 annotated radiographs,...
This study proposes a deep-learning algorithm to automatically detect perilunate dislocation on anteroposterior wrist radiographs. A total of 374 annotated radiographs, 345 normal and 29 pathological, were used to train, validate and test two YOLO v8 deep neural models. The first model was used for detecting the carpal region, and the second for segmenting a region between Gilula's second and third arcs. The output of the segmentation model, trained multiple times with varying random initial parameter values and augmentations, was then assigned a probability of being normal or pathological through ensemble averaging. In this dataset, the algorithm achieved an overall F1-score of 0.880: 0.928 in the normal subgroup, with 1.0 precision, and 0.833 in the pathological subgroup with 1.0 recall (or sensitivity), demonstrating that the diagnosis of perilunate dislocation can be improved through automatic analysis of anteroposterior radiographs. Level of evidence: III.
PubMed: 38909690
DOI: 10.1016/j.hansur.2024.101742 -
Scientific Reports Jun 2024Currently, there is a lack of relevant research on the efficacy difference between SHD combined with IBG and PVIBGT in the treatment of osteonecrosis of the femoral... (Comparative Study)
Comparative Study
Currently, there is a lack of relevant research on the efficacy difference between SHD combined with IBG and PVIBGT in the treatment of osteonecrosis of the femoral head(ONFH). Firstly, this study intends to compare the effectiveness of surgical hip dislocation combined with impacting bone grafts (SHD-IBG) and pedicled vascularised iliac bone graft transfer (PVIBGT) in treating ONFH. And the study investigates patients who suffered from hip preservation failures from both groups to better comprehend failure reasons. 30 patients (34 hips) with ARCO stage IIIA femoral head necrosis were selected between January 2012 and July 2022. They were divided into group A(SHD-IBG) and group B (PVIBGT) according to different surgical methods. Firstly, compared the 1-year effect between SHD-IBG and PVIBGT at 1 year postoperatively; Secondly, assessed the medium and long-term efficacy of SHD-IBG hip preservation treatment; Lastly, based on study of the femoral head removed from patients with hip preservation failure in the two groups, the reasons for the failure of hip preservation were comprehensively analyzed in the two groups. Group A: 11 males (13 hips), 4 females (4 hips);Group B: 9 males (11 hips), 6 females (6 hips).Firstly, the average Harris scores of the two groups at 1 year after surgery: preoperative: 70.7, 1 year after surgery: 78.9 in group A; preoperative: 69.5, 1 year after surgery: 81.5 in group B. The differences were statistically significant (P < 0.05).Compared to the preoperative period, quantitative analysis by DCE-MRI showed an increase in perfusion in the necroticarea and an improvement in hyperperfusion in the repair-responsive area one year after the surgery. Secondly, in group A, the hip preservation rate was 88.2% at 2.5-11 (average of 77 months) years of follow-up, and the mean Harris score at the last follow-up was 73.2.Semi-quantitative analysis of postoperative DCE-MRI showed that the perfusion curves of necrotic and repaired areas were similar to those of the normal area. This suggests the instability within the femoral head had been effectively improved, and the perfusion had partially recovered. Thirdly, according to Micro-CT and pathologica studies of patients with hip preservation failure in these two groups, all these patients' femoral head was significantly collapsed and deformed. Their trabeculae was thin and partially disorganized, with fractures in the subchondral bone and separation of the cartilage from the subchondral bone. The necrotic areas had sparse trabeculae, disorganized arrangement, loss of continuity, and disappearance of cells in the trabecular traps. The necrotic area was covered with fibrous tissue, and partial restoration was observed in the repair area. Mechanical finite element analysis showed that the maximum equivalent force was observed in the weight- bearing area and the cortical bone surrounding the shaft of femurand. The result of DCE-MRI showed that the repair reaction area exhibited abnormal hyperperfusion. In this study, the efficacy of SHD-IBG and PVIBGT was compared at 1 year after operation, and the long-term follow-up of SHD-IBG was 2.5-11 (mean 77 months) years, combined with DCE-MRI results, we found that the short-term effect of PVIBGT was more significant than that of SHD-IBG. SHD-IBG can achieve satisfactory hip preservation in the medium and long term follow-up.
Topics: Humans; Female; Male; Femur Head Necrosis; Adult; Middle Aged; Bone Transplantation; Treatment Outcome; Ilium; Femur Head; Hip Dislocation
PubMed: 38909104
DOI: 10.1038/s41598-024-65197-9 -
Arthroplasty (London, England) Jun 2024The use of long stems for severe femoral bone defects is suggested by many scholars, but it is associated with further bone loss, intraoperative fracture, increased...
BACKGROUND
The use of long stems for severe femoral bone defects is suggested by many scholars, but it is associated with further bone loss, intraoperative fracture, increased surgical trauma, and complications. With better bone retention, simple and quick surgical procedures, and minimal complications, the short cementless stems with a tapered rectangular shape may be an alternative for femoral revision. This study aimed to evaluate the results of this type of stem in treating selected Paprosky II-IV bone defects.
METHODS
This retrospective study included 73 patients (76 hips involved) who underwent conservative femoral revision using the short cementless stems with a tapered rectangular shape between January 2012 and December 2020. The preoperative femoral bone defects were identified as follows: 54 cases of type II, 11 cases of type IIIA, 7 cases of type IIIB, and 4 cases of type IV. Indications for revision included aseptic loosening (76.3%) and prosthetic joint infection (23.7%). Six cementless stems with a tapered rectangular shape from three companies were used in all patients. Among them, SLR-Plus, SL-Plus MIA, and Corail stems were employed in most patients (40.8%, 23.7%, and 17.1%, respectively). The average length of these stems measured 171.7 mm (SD 27 mm; 122-215 mm). Radiographic results, Harris hip scores (HHS), complications, and survivorship were analyzed. The follow-up lasted for 7 years on average (range 3-11 years).
RESULTS
The subsidence was observed in three hips (3.9%), and all stems achieved stable bone ingrowth. Proximal femoral bone restoration in the residual osteolytic area was found in 67 hips (88.2%), constant defects in nine hips (11.8%), and increasing defects in 0 cases. There was no evidence of stem fractures and stem loosening in this series. The mean HHS significantly improved from 32 (range 15-50) preoperatively to 82 (range 68-94) at the last follow-up (t = - 36.297, P < 0.001). Five hips developed prosthesis-related complications, including three infection and two dislocation cases. The mean 5- and 10-year revision-free survivorships for any revision or removal of an implant and reoperation for any reason were 94.6% and 93.3%, respectively. Both mean 5- and 10-year revision-free survivorships for aseptic femoral loosening were 100%.
CONCLUSION
Conservative femoral revision using short cementless stems with a tapered rectangular shape can provide favorable radiographic outcomes, joint function, and mid-term survivorship with minimal complications. Of note, a sclerotic proximal femoral bone shell with continued and intact structure and enough support strength is the indication for using these stems.
PubMed: 38907318
DOI: 10.1186/s42836-024-00251-5 -
Indian Journal of Ophthalmology Jul 2024The aim of this study is to describe a modified technique for internal refixation of dislocated scleral-sutured polymethylmethacrylate (PMMA) intraocular lenses (IOLs)...
The aim of this study is to describe a modified technique for internal refixation of dislocated scleral-sutured polymethylmethacrylate (PMMA) intraocular lenses (IOLs) with eyelets. Three-port pars plana vitrectomy was performed. Through the scleral fixation site, a 30-gauge needle loaded with an 8-0 polypropylene suture was inserted into the vitreous cavity. The suture end was passed through the eyelet of IOL with 25-gauge forceps. Next, it was guided out of the eye through the original scleral fixation point. The end of the exterior suture was buried with a flapless intrascleral knotting technique. Six eyes of six patients were successfully treated with this technique and followed up for 6-12 months postsurgery. In all cases, there was significant improvement in uncorrected visual acuity. IOLs were stable with proper centration and no major complications. This modified technique offers an effective and minimally invasive surgical alternative for refixation of dislocated scleral-sutured PMMA IOLs with eyelets.
Topics: Humans; Polymethyl Methacrylate; Male; Visual Acuity; Lenses, Intraocular; Female; Reoperation; Suture Techniques; Vitrectomy; Middle Aged; Sclera; Artificial Lens Implant Migration; Follow-Up Studies; Aged; Sutures; Adult
PubMed: 38905465
DOI: 10.4103/IJO.IJO_2809_23 -
Journal of Hand Surgery Global Online Mar 2024Articular comminuted fracture dislocations of the base of the middle phalanx represent a major challenge for the surgeon. The treatment goal is a nonpainful, stable, and...
Articular comminuted fracture dislocations of the base of the middle phalanx represent a major challenge for the surgeon. The treatment goal is a nonpainful, stable, and functional proximal interphalangeal joint, which is achieved through concentric joint reduction and restoration of joint stability. Fracture pattern rarely results in sagittal bone loss involving the entire ulnar or radial pilon of the base of the second phalanx. In these cases, the choice of treatment can be particularly challenging as the loss of a pillar of the articular base causes angular deviation at the joint level, thus causing the loss of finger joint flexion and overlap of the adjacent finger. We present a novel nonvascularized osteochondral graft, which we named hemi--hamate osteochondral graft a modified version of the traditional hemi-hamate arthroplasty, that is suitable for the reconstruction of bone loss involving the whole anteroposterior hemiarticular surface of the base of the P2.
PubMed: 38903846
DOI: 10.1016/j.jhsg.2023.11.009 -
JBJS Essential Surgical Techniques 2024A number of techniques have been described to enter the capsule and gain access to the hip joint during hip arthroscopy. Among these, the interportal and T-capsulotomies...
BACKGROUND
A number of techniques have been described to enter the capsule and gain access to the hip joint during hip arthroscopy. Among these, the interportal and T-capsulotomies are the most commonly utilized; however, these approaches transect the iliofemoral ligament, which normally resists anterior subluxation and stabilizes extension. Thus, these approaches may introduce capsuloligamentous instability and have been associated with complications such as dislocation, postoperative pain, microinstability, seroma, and heterotopic ossification. Although prior literature has demonstrated durable mid-term results for patients undergoing capsulotomies with capsular closure, avoidance of iatrogenic injury to the hip capsule altogether is preferable. Thus, the puncture capsulotomy technique we present is minimally invasive, preserves the biomechanics of the hip joint and capsule without disrupting the iliofemoral ligament, and allows for appropriate visualization of the joint through placement of multiple small portals.
DESCRIPTION
Following induction of anesthesia and with the patient supine on a hip traction table, the nonoperative leg is positioned at 45° abduction with support of a well-padded perineal post, and the operative hip is placed into valgus against the post. Intra-articular fluid distention with normal saline solution is utilized to achieve approximately 9 mm of inferior migration of the femoral head and decrease risk of iatrogenic nerve injury. Then, under fluoroscopic guidance, an anterolateral portal is created 1 cm anterior and 1 cm superior to the greater trochanter at an approximately 15° to 20° angle. Second, via arthroscopic visualization, the anterior portal is created 1 cm distal and 1 cm lateral to the intersection of a vertical line drawn at the anterior superior iliac spine and a horizontal line at the level of the anterolateral portal. Third, equidistant between the anterior and anterolateral portals, the mid-anterior portal is created distally. Finally, at one-third of the distance between the anterior superior iliac spine and the anterolateral portal, the Dienst portal is created. Thus, these 4 portals form a quadrilateral arrangement through which puncture capsulotomy can be performed.
ALTERNATIVES
Alternative approaches to the hip capsule include interportal and T-capsulotomies, with or without capsular closure. Although the most frequently utilized, these approaches transect the iliofemoral ligament and thus may introduce capsuloligamentous instability.
RATIONALE
The puncture capsulotomy technique has the advantage of maintaining the integrity of the capsule through the placement of 4 small portals. The technique does not transect the iliofemoral ligament and thus does not introduce capsuloligamentous instability. Furthermore, although good mid-term outcomes have been reported with capsular closure, the present technique avoids creating unnecessary injury to the capsule and complications of an unrepaired capsule or, conversely, of plication.
EXPECTED OUTCOMES
Patients who underwent the puncture capsulotomy technique showed significant improvements in multiple functional outcome scores at a mean follow-up of 30.4 months, including the International Hip Outcome Tool (iHOT-33) (39.6 preoperatively to 76.1 postoperatively), Hip Outcome Score-Activities of Daily Living subscale (HOS-ADL) (70.0 to 89.3), HOS Sport-Specific Subscale (HOS-SSS) (41.8 to 75.7), and modified Harris hip score (mHHS) (60.1 to 84.9). At 2 years postoperatively with respect to iHOT-33, 81.0% of patients achieved the minimal clinically important difference, 62.0% achieved the patient acceptable symptom state, and 58.9% achieved substantial clinical benefit. In addition, mean visual analog scale pain scores improved significantly over the follow-up period (6.3 to 2.2; p < 0.001). Finally, there were zero occurrences of infection, osteonecrosis of the femoral head, dislocation or instability, or femoral neck fracture in patients treated with puncture capsulotomy.
IMPORTANT TIPS
Anterolateral portal placement should be performed using the intra-articular fluid distention technique with fluoroscopy to avoid risk of iatrogenic labral damage and distraction-induced neurapraxia. Subsequent portals must then be placed under direct arthroscopic visualization.On establishment of the anterolateral portal, the scope should be switched to the anterior portal to ensure that the anterolateral portal has not been placed through the labrum and to adjust its placement to better access pathology. This portal, as well as all others, may be subsequently modified by adjusting the angle of the cannula, without making a new skin incision.If a cam lesion is located more anteromedially or posterolaterally, an additional accessory portal may be made distal or proximal to the anterolateral portal, respectively, in order to enhance visualization.Intermittent traction is utilized throughout the surgery. No traction is utilized during preparing and draping, suture tensioning and tie-down, and femoroplasty, with minimal traction during acetabuloplasty; these precautions serve to prevent iatrogenic superficial peroneal nerve injury.There can be a steep learning curve for this technique. In particular, greater surgical experience is required to perform adequate femoral osteoplasty for large cam lesions with this approach.Instrument maneuverability and visualization can be somewhat constrained with this approach.It is more difficult to perform certain procedures with this technique, including segmental and circumferential labral reconstructions, particularly with remote grafts.
ACRONYMS AND ABBREVIATIONS
iHOT-33 = International Hip Outcome Tool-33HOS-ADL = Hip Outcome Score-Activities of Daily Living subscaleHOS-SSS = Hip Outcome Score-Sport-Specific SubscaleAP = anteroposteriorMRA = magnetic resonance arthrogramMRI = magnetic resonance imagingCT = computed tomographyASIS = anterior superior iliac spinemHHS = modified Harris hip score.
PubMed: 38903605
DOI: 10.2106/JBJS.ST.23.00061 -
Cureus May 2024A dislocation or break of the tarsometatarsal joint in the foot is referred to as a Lisfranc fracture, sometimes called a Lisfranc injury. It can be caused by less...
A dislocation or break of the tarsometatarsal joint in the foot is referred to as a Lisfranc fracture, sometimes called a Lisfranc injury. It can be caused by less stressful mechanisms like a twisting fall as well as high-energy events like car crashes or falls from heights. Swelling, bruises, and midfoot pain that gets worse when standing or walking are some of the symptoms. The damage may only affect the ligaments or the foot's bony structures. Nonoperative or surgical treatment may be part of the management, depending on how severe the injury is. In order to realign and stabilize the bones, open reduction internal fixation with Kirschner wires (K-wires) is a common surgical procedure. In this case, a 25-year-old male patient complained of left foot pain and wound. He gave a history of a left leg stuck in the harvester. Immediately, he was taken to a local hospital, where a dressing of his left foot was done. He was referred to a super specialty hospital where an investigation, like an X-ray, was done, which revealed a Lisfranc fracture. K-wire was applied to fix the Lisfranc fracture. Further on, rehabilitation was started to restore mobility, regain full range of motion, and develop muscle strength. American Orthopedic Foot and Ankle Score (AOFAS) and Lower Extremity Functional Scale (LEFS) were used as outcome measures.
PubMed: 38903267
DOI: 10.7759/cureus.60722