-
Materials (Basel, Switzerland) Jun 2024Fiber laser cutting machines are widely used in industry for cutting various sheet metals. Hardox steel is widely used in the construction of machinery and equipment...
Fiber laser cutting machines are widely used in industry for cutting various sheet metals. Hardox steel is widely used in the construction of machinery and equipment that are subjected to wear and impact due to its anti-wear properties and good impact resistance. In this experimental study, the effect of input parameters including laser output power (LOP), laser-cutting speed (LCS), and focal point position (FPP) of fiber laser on the surface roughness and kerf width of Hardox 400 steel sheets are studied. In addition, the optimization of input parameters to achieve the desired surface roughness and kerf width are investigated and analyzed using the response surface methodology (RSM). The experiments are performed using a 4 kW fiber laser-cutting machine and the output results including surface roughness and kerf width are measured using roughness meters and optical microscope. The results of the analysis of variance (ANOVA) for surface roughness and kerf width show that the FPP and LCS are the most significant process parameters affecting the surface roughness and kerf width. With a positive focal point, the surface roughness decreases while the kerf width increases. With increasing the laser-cutting speed, both the surface roughness and kerf width decrease.
PubMed: 38930168
DOI: 10.3390/ma17122798 -
Journal of Clinical Medicine Jun 2024: Gait speed indicates the individual's functional status and predicts overall health. This study aims to determine (1) the intra- and inter-rater and test-retest...
: Gait speed indicates the individual's functional status and predicts overall health. This study aims to determine (1) the intra- and inter-rater and test-retest reliability of the dynamic 4 m gait speed test protocol; (2) establish the normative reference values of habitual and fast gait speeds in community-dwelling healthy Singaporean adults aged 21 to 80; and (3) explore the association of age, gender, height, weight, and body mass index (BMI) on gait speed. : This prospective cross-sectional study recruited healthy ambulatory community-dwelling Singaporeans aged 21 to 80 who could ambulate independently without aid. Participants were excluded if they required walking aids; were pregnant; or had physical, medical, or cognitive conditions that may affect gait. Each participant completed at least two habitual and fast gait speed test trials via a 4 m walkway with a dynamic start. The data were analysed by descriptive statistics, the Mann-Whitney test, the Spearman coefficient, and the interclass correlation coefficient (ICC). : In total, 178 males and 201 females were included in the data analysis. The median age was 45.0 years [interquartile range (IQR) 26.2-59.0], and the median height was 1.64 metres (m) (IQR 1.58-1.70). The median habitual gait speed was 1.08 metre/second (m/s) (IQR 0.97-1.22), and the fast gait speed was 1.55 m/s (IQR 1.40-1.70). The ICC for reliability ranged from 0.84 to 0.99, indicating that the 4 m gait speed test had good-to-excellent reliability. : Gait speeds were not influenced by gender but declined with age advancement. Age and height and age and BMI were weakly correlated to habitual and fast gait speed, respectively. We established the norm values for the 4 m gait speeds in Singapore and proved it to be a reliable gait speed assessment ready for immediate community applications.
PubMed: 38930036
DOI: 10.3390/jcm13123507 -
Journal of Personalized Medicine Jun 2024Anterior cruciate ligament (ACL) instability poses a considerable challenge in traumatology and orthopedic medicine, demanding precise diagnostics for optimal treatment....
Anterior cruciate ligament (ACL) instability poses a considerable challenge in traumatology and orthopedic medicine, demanding precise diagnostics for optimal treatment. The pivot-shift test, a pivotal assessment tool, relies on subjective interpretation, emphasizing the need for supplementary imaging. This study addresses this limitation by introducing a machine learning classification algorithm integrated into a mobile application, leveraging smartphones' built-in inertial sensors for dynamic rotational stability assessment during knee examinations. Orthopedic specialists conducted knee evaluations on a cohort of 52 subjects, yielding valuable insights. Quantitative analyses, employing the Intraclass Correlation Coefficient (ICC), demonstrated robust agreement in both intraobserver and interobserver assessments. Specifically, ICC values of 0.94 reflected strong concordance in the timing between maneuvers, while signal amplitude exhibited consistency, with the ICC ranging from 0.71 to 0.66. The introduced machine learning algorithms proved effective, accurately classifying 90% of cases exhibiting joint hypermobility. These quantifiable results underscore the algorithm's reliability in assessing knee stability. This study emphasizes the practicality and effectiveness of implementing machine learning algorithms within a mobile application, showcasing its potential as a valuable tool for categorizing signals captured by smartphone inertial sensors during the pivot-shift test.
PubMed: 38929873
DOI: 10.3390/jpm14060651 -
Bioengineering (Basel, Switzerland) May 2024This work introduces Spiromni, a single device incorporating three different pressurised metered-dose inhaler (pMDI) accessories: a pMDI spacer, an electronic monitoring...
This work introduces Spiromni, a single device incorporating three different pressurised metered-dose inhaler (pMDI) accessories: a pMDI spacer, an electronic monitoring device (EMD), and a spirometer. While there are devices made to individually address the issues of technique, adherence and monitoring, respectively, for asthma patients as laid out in the Global Initiative for Asthma's (GINA) global strategy for asthma management and prevention, Spiromni was designed to address all three issues using a single, combination device. Spiromni addresses the key challenge of measuring both inhalation and exhalation profiles, which are different by an order of magnitude. Moreover, the innovative design prevents exhalation from entering the spacer chamber and prevents medication loss during inhalation using umbrella valves without a loss in flow velocity. Apart from recording the peak exhalation flow rate, data from the sensors allow us to extract other key lung volume and capacities measures similar to a medical pulmonary function test. We believe this low-cost portable multi-functional device will benefit both asthma patients and clinicians in the management of the disease.
PubMed: 38927788
DOI: 10.3390/bioengineering11060552 -
Journal of Neuroengineering and... Jun 2024People with Parkinson's Disease (PD) show abnormal gait patterns compromising their independence and quality of life. Among all gait alterations due to PD, reduced step...
INTRODUCTION
People with Parkinson's Disease (PD) show abnormal gait patterns compromising their independence and quality of life. Among all gait alterations due to PD, reduced step length, increased cadence, and decreased ground-reaction force during the loading response and push-off phases are the most common. Wearable biofeedback technologies offer the possibility to provide correlated single or multi-modal stimuli associated with specific gait events or gait performance, hence promoting subjects' awareness of their gait disturbances. Moreover, the portability and applicability in clinical and home settings for gait rehabilitation increase the efficiency in the management of PD. The Wearable Vibrotactile Bidirectional Interface (BI) is a biofeedback device designed to extract gait features in real-time and deliver a customized vibrotactile stimulus at the waist of PD subjects synchronously with specific gait phases. The aims of this study were to measure the effect of the BI on gait parameters usually compromised by the typical bradykinetic gait and to assess its usability and safety in clinical practice.
METHODS
In this case series, seven subjects (age: 70.4 ± 8.1 years; H&Y: 2.7 ± 0.3) used the BI and performed a test on a 10-meter walkway (10mWT) and a two-minute walk test (2MWT) as pre-training (Pre-trn) and post-training (Post-trn) assessments. Gait tests were executed in random order with (Bf) and without (No-Bf) the activation of the biofeedback stimulus. All subjects performed three training sessions of 40 min to familiarize themselves with the BI during walking activities. A descriptive analysis of gait parameters (i.e., gait speed, step length, cadence, walking distance, double-support phase) was carried out. The 2-sided Wilcoxon sign-test was used to assess differences between Bf and No-Bf assessments (p < 0.05).
RESULTS
After training subjects improved gait speed (Pre-trn_No-Bf: 0.72(0.59,0.72) m/sec; Post-trn_Bf: 0.95(0.69,0.98) m/sec; p = 0.043) and step length (Pre-trn_No-Bf: 0.87(0.81,0.96) meters; Post-trn_Bf: 1.05(0.96,1.14) meters; p = 0.023) using the biofeedback during the 10mWT. Similarly, subjects' walking distance improved (Pre-trn_No-Bf: 97.5 (80.3,110.8) meters; Post-trn_Bf: 118.5(99.3,129.3) meters; p = 0.028) and the duration of the double-support phase decreased (Pre-trn_No-Bf: 29.7(26.8,31.7) %; Post-trn_Bf: 27.2(24.6,28.7) %; p = 0.018) during the 2MWT. An immediate effect of the BI was detected in cadence (Pre-trn_No-Bf: 108(103.8,116.7) step/min; Pre-trn_Bf: 101.4(96.3,111.4) step/min; p = 0.028) at Pre-trn, and in walking distance at Post-trn (Post-trn_No-Bf: 112.5(97.5,124.5) meters; Post-trn_Bf: 118.5(99.3,129.3) meters; p = 0.043). SUS scores were 77.5 in five subjects and 80.3 in two subjects. In terms of safety, all subjects completed the protocol without any adverse events.
CONCLUSION
The BI seems to be usable and safe for PD users. Temporal gait parameters have been measured during clinical walking tests providing detailed outcomes. A short period of training with the BI suggests improvements in the gait patterns of people with PD. This research serves as preliminary support for future integration of the BI as an instrument for clinical assessment and rehabilitation in people with PD, both in hospital and remote environments.
TRIAL REGISTRATION
The study protocol was registered (DGDMF.VI/P/I.5.i.m.2/2019/1297) and approved by the General Directorate of Medical Devices and Pharmaceutical Service of the Italian Ministry of Health and by the ethics committee of the Lombardy region (Milan, Italy).
Topics: Humans; Parkinson Disease; Aged; Male; Wearable Electronic Devices; Biofeedback, Psychology; Female; Gait Disorders, Neurologic; Middle Aged; Gait
PubMed: 38926876
DOI: 10.1186/s12984-024-01403-z -
Journal of Cardiothoracic Surgery Jun 2024Historically, the majority of patients admitted to inpatient exercise-based cardiac rehabilitation (EBCR) have undergone open heart surgery (OHS). However, with advances... (Comparative Study)
Comparative Study
BACKGROUND
Historically, the majority of patients admitted to inpatient exercise-based cardiac rehabilitation (EBCR) have undergone open heart surgery (OHS). However, with advances in minimally invasive cardiac surgery (MICS), these patient groups are also increasingly referred for inpatient EBCR. Herein, we aimed to compare the progress of these groups during rehabilitation.
METHODS
In this prospective, nonrandomized study, 403 inpatient EBCR patients were recruited from December 2022 until September 2023 and stratified into two groups: OHS, and MICS. Participants completed a 3-4-week certified EBCR program. The primary endpoint was defined as a change in the 6-minute walk test (6MWT). Moreover, a comprehensive panel of quality-of-life (QoL) assessments were performed at admission and discharge.
RESULTS
At baseline, patients with OHS were older (66 years [IQR 59 - 72]), more often male (83%), and underwent emergency/urgent procedures more often (20%) than patients with MICS. Furthermore, patients with MICS showed a better 6MWT at admission (426 meters [IQR 336 - 483]) compared to patients with OHS (381 meters [IQR 299 - 453]). While all patients were able to increase the distance in the 6MWT, regression analyses in fully adjusted models showed no difference in improvements between the two groups (β -5, 95% CI, -26 - 14, p = 0.58). Moreover, during EBCR, we observed significant improvements in all QoL measures in all groups.
CONCLUSIONS
In this study, improvements in fitness, as assessed by the 6WMT were observed in all groups. Furthermore, multiple QoL measures improved equally across all groups. These encouraging results emphasize the importance of EBCR.
Topics: Humans; Male; Female; Aged; Cardiac Surgical Procedures; Prospective Studies; Middle Aged; Cardiac Rehabilitation; Minimally Invasive Surgical Procedures; Quality of Life; Exercise Therapy; Walk Test
PubMed: 38926740
DOI: 10.1186/s13019-024-02871-z -
Brazilian Dental Journal 2024This study aimed to determine the effect of adding selenium nanoparticles (SeNPs) to mineral trioxide aggregate (MTA HP) concerning alkalinizing potential. Additionally,...
This study aimed to determine the effect of adding selenium nanoparticles (SeNPs) to mineral trioxide aggregate (MTA HP) concerning alkalinizing potential. Additionally, it examined the set material after SeNPs incorporation using Field Emission Scanning Electron Microscopy with Energy Dispersive X-ray analysis (FE-SEM/EDX) for characterizing the elemental composition and morphological alterations resulting from the integration of SeNPs. Cement samples, both before and after SeNPs incorporation, were examined using FE-SEM/EDX. The pH level was also measured with a pH-meter previously calibrated with solutions of known pH, to evaluate the alkalinizing activity of the integrated substance at different concentrations of nanoparticles: Group 1 (control): 0% w/w SeNPs, Group 2: 0.5% w/w SeNPs, Group 3: 1% w/w SeNPs, Group 4: 1.5% w/w SeNPs and Group 5: 2% w/w SeNPs after 1, 7, 14, and 30 days in distal water. The data were analyzed by one-way ANOVA and Tukey tests (P≤0.05). According to FE-SEM/EDX, the morphological characteristics indicate that SeNPs were successfully dispersed and integrated into the MTA repair matrix. EDX examination validates the presence of Selenium, confirming successful integration. The findings confirmed that the MTAHP showed a high pH level with a discernible reduction in the alkalinizing activity with each incorporated concentration of (SeNPs) that significantly differed from the control group across various periods at (P≤ 0.05). Consequently, the findings indicate that the addition of SeNPs to MTA HP has a notable impact on the pH of the storage solution, leading to a significant decrease in pH values for all concentrations and periods when compared to the control group. The alkalinizing action of MTA HP is highly affected by the incorporated SeNPs, making it more suitable for application in pulpal tissue. This study contributes to our understanding of the morphological alterations and elemental composition of SeNP-incorporated MTA HP, enhancing its potential applications in dental and tissue regeneration.
PubMed: 38922250
DOI: 10.1590/0103-6440202405760 -
JAMA Network Open Jun 2024Major concerns regarding individuals who adhere to a vegan diet are whether they meet protein and essential amino acid recommendations and how reliant they are on...
IMPORTANCE
Major concerns regarding individuals who adhere to a vegan diet are whether they meet protein and essential amino acid recommendations and how reliant they are on ultraprocessed foods.
OBJECTIVES
To investigate whether individuals who adhere to a vegan diet meet protein and essential amino acid recommendations and, as secondary objectives, to determine ultraprocessed food intake and potential factors associated with inadequate protein intake in this population.
DESIGN, SETTING, AND PARTICIPANTS
This cross-sectional survey study was conducted between September 2021 and January 2023 in Brazil among male and female adults (aged 18 years or older) who adhered to a vegan diet recruited from social media platforms.
EXPOSURE
Adherence to a vegan diet and unprocessed and minimally processed foods and ultraprocessed food consumption.
MAIN OUTCOMES AND MEASURES
Protein and essential amino acid intake and food consumption by processing level were assessed using a 1-day food diary. Nutrient adequacy ratios were calculated by dividing nutrient intake by its recommendation (using scores truncated at 1) for each participant and then finding the mean across participants for each nutrient. The mean adequacy ratio was the mean of all nutrient adequacy ratios.
RESULTS
Of 1014 participants who completed the survey, 774 individuals (median [IQR] age, 29 [24-35] years; 637 female [82.3%]) were confirmed as adhering to a vegan diet and provided adequate food recalls, among whom 558 individuals reported body weight and so had relative protein and amino acid intake values available. The median (IQR) body mass index (calculated as weight in kilograms divided by height in meters squared) of participants was 22.6 (20.3-24.8). The nutrient adequacy ratio of protein was 0.93 (95% CI, 0.91-0.94); for essential amino acids, ratios ranged from 0.90 (95% CI, 0.89-0.92) for lysine to 0.98 (95% CI, 0.97-0.99) for phenylalanine and tyrosine. The mean adequacy ratio for protein and all amino acids was 0.95 (95% CI, 0.94-0.96). The median intake level was 66.5% (95% CI, 65.0%-67.9%) of total energy intake for unprocessed and minimally processed food and 13.2% (95% CI, 12.4%-14.4%) of total energy intake for ultraprocessed food. Adjusted logistic regression models showed that consuming protein supplements (odds ratio [OR], 0.06 [95% CI 0.02-0.14]; P < .001) or textured soy protein (OR, 0.32 [95% CI, 0.17-0.59]; P < .001) was associated with decreased odds of inadequate protein intake. Higher ultraprocessed food intake levels were also associated with decreased odds of inadequate protein intake (eg, fourth vs first quartile of intake: OR, 0.16 [95% CI, 0.07-0.33]; P < .001), and higher unprocessed and minimally processed protein intake levels were associated with increased odds of inadequate protein intake (eg, fourth vs first quartile of intake: OR, 12.42 [95% CI, 5.56-29.51]; P < .001).
CONCLUSIONS AND RELEVANCE
In this study, most individuals who adhered to a vegan diet attained protein and essential amino acid intake recommendations, largely based their diet of unprocessed and minimally processed food, and had a significantly lower proportion of ultraprocessed food intake compared with previous reports. Participants consuming less ultraprocessed food were more likely to have inadequate protein intake, suggesting a significant reliance on ultraprocessed proteins for this population.
Topics: Humans; Female; Male; Adult; Brazil; Cross-Sectional Studies; Dietary Proteins; Vegans; Young Adult; Diet, Vegan; Food Handling; Middle Aged; Eating; Amino Acids; Amino Acids, Essential
PubMed: 38913373
DOI: 10.1001/jamanetworkopen.2024.18226 -
Heliyon Jun 2024The discrepancy between the operating and design capacities of solar plants in eastern Uganda is alarming; about 35 % underperformance in solar power generation is...
The discrepancy between the operating and design capacities of solar plants in eastern Uganda is alarming; about 35 % underperformance in solar power generation is observed. The goal of the current study is to minimize this disparity by improving the design models. Considering only cell temperature in the power generation model is responsible for the observed difference in design and operational solar power generated, the present study used a thermocouple to directly measure cell temperature, an anemometer to measure wind speed, and a solar power meter to measure irradiance. These extrinsic factors were used to modify the power generation model based only on cell temperature through the direct correlation of cell temperature, wind speed, and irradiance with solar power generation. Thus, the absence of extrinsic factors (wind speed and irradiance) in the design models is responsible for the colossal drop in solar power generated. Empirically, the missing extrinsic factors were used to transform the implicit solar power model into an explicit model. The development of a solar power generation model, multiple differential models, simulation and experimentation with a pilot solar rig served as alternate model for the prediction of solar power generation. The second-order differential model validated well with empirical solar power generated in Busitema, Mayuge, Soroti, and Tororo study areas based on RMSEs (0.6437, 0.6692, 0.2008, 0.1804, respectively), thus, narrowing the gap between the designed and operational solar power generated. Mayuge and Soroti recorded the highest solar power generation of 9.028 MW compared to Busitema (8.622 MW) and Tororo (8.345 MW), suggesting that it has a conducive site for installing future solar plants. The above results support the use of empirical explicit (triple) and second-order differential models for the design and operation of power plants.
PubMed: 38912472
DOI: 10.1016/j.heliyon.2024.e32353 -
Heliyon Jun 2024In recent years, the use of solar photovoltaic (PV) energy, which is one of the leading renewable energy sources, has become increasingly widespread around the world due...
In recent years, the use of solar photovoltaic (PV) energy, which is one of the leading renewable energy sources, has become increasingly widespread around the world due to its numerous advantages. However, PV-based electricity generation necessitates a large amount of land. Agrivoltaic (AV) systems, an innovative approach to combining agricultural and electricity production in the same area through solar modules positioned several meters above the surface of the ground, are growing rapidly in renewable energy and farming communities. This study explores Turkey's solar power generation and agricultural activities, combining crop cultivation and electricity generation for sustainable development on the same land. Furthermore, the AV potential for the most agriculture ten cities in different climate zones in Turkey is investigated using the PVsyst program. A list of the most commonly grown crops in the ten selected cities and the types of AV systems that can be employed with these crops is provided. The results show that AV systems present a great opportunity for the optimal integration of solar power generation with food production, especially for the cities of Konya, Kayseri, and Manisa, with the most ideal conditions for agricultural and solar power production. By combining the solar power potential of the country with the production capacity of arable lands, the increasing energy needs can be met and more efficient agricultural production can be provided. This study is expected to demonstrate that in specific regions of Turkey, AV farming will be suitable for certain crops.
PubMed: 38912471
DOI: 10.1016/j.heliyon.2024.e32300