-
BMC Oral Health May 2024In this study, the antimicrobial activity of three different cleanser tablets on S. mutans and C. albicans adhesion to PMMA, polyamide and 3D printed resin was...
BACKGROUND
In this study, the antimicrobial activity of three different cleanser tablets on S. mutans and C. albicans adhesion to PMMA, polyamide and 3D printed resin was investigated.
METHODS
40 samples were prepared for PMMA (SR Triplex Hot), polyamide (Deflex) and 3D printed resin (PowerResins Denture) materials and divided into four subgroups for cleansers (Aktident™, Protefix™, Corega™ tablets and distilled water) (n = 5). After the surface preparations were completed, the samples were immersed separately in tubes containing the prepared microorganism suspension and incubated at 37˚C for 24 h. After the incubation, the samples were kept in the cleanser solutions. The samples were then transferred to sterile saline tubes. All the tubes were vortexed and 10 µl was taken from each of them. Sheep blood agar was inoculated for colony counting. The inoculated plates were incubated for 48 h for S. mutans and 24 h for C. albicans. After incubation, colonies observed on all plates were counted. Statistical analyses were done with three-way ANOVA and Tukey's multiple comparison test.
RESULTS
Polyamide material registered the highest colony count of S. mutans, whereas PMMA registered the lowest. Significant differences in S. mutans adherence (p = 0.002) were found between the three denture base materials, but no such difference in C. albicans adherence (p = 0.221) was identified between the specimens. All three cleanser tablets eliminated 98% of S. mutans from all the material groups. In all these groups, as well, the antifungal effect of Corega™ on C. albicans was significantly higher than those of the other two cleanser tablets.
CONCLUSIONS
According to the study's results, it may be better to pay attention to surface smoothness when using polyamide material to prevent microorganism retention. Cleanser tablets are clinically recommended to help maintain hygiene in removable denture users, especially Corega tablets that are more effective on C. albicans.
Topics: Candida albicans; Streptococcus mutans; Denture Bases; Denture Cleansers; Polymethyl Methacrylate; Nylons; Tablets; Colony Count, Microbial; Dental Materials; Bacterial Adhesion; Anti-Infective Agents; Materials Testing
PubMed: 38811903
DOI: 10.1186/s12903-024-04403-6 -
BMC Oral Health May 2024This study aimed to investigate the effects of new and used burs on CAD-CAM PMMA resin color changes following thermocycling.
PURPOSE
This study aimed to investigate the effects of new and used burs on CAD-CAM PMMA resin color changes following thermocycling.
MATERIALS AND METHODS
Twenty disk-shaped specimens (10 × 2 mm) were made using a single brand of CAD-CAM polymethyl methacrylate resin (Polident) for the color test. Group N consisted of half of the specimens that were machined using the new tungsten carbide bur set, and Group U consisted of the specimens that were milled using the used bur set (500 machining time). A color test was performed on the specimens both before and after thermocycling. For the statistical analysis, the Kruskal-Wallis and Dunn Pairwise Comparison tests were employed.
RESULTS
The ∆E* value of specimens (2.057) milled with the used bur was higher than those of specimens milled with the new bur (0.340), but this value is within clinically acceptable limits. After thermocycling, specimens milled with the utilized burs had the greatest L* (93.850) and b* (5.000) values. After thermocycling, statistically significant differences were discovered between Group N and Group U as well as between specimens milled with the utilized bur before and after thermocycling.
CONCLUSION
Thermocycling process have an effect on the mean ∆E values of specimens milled with the used carbide bur, but these ∆E* values were not statistically significant.
CLINICAL SIGNIFICANCE
The color and clinical performance of CAD-CAM restorations may be affected by variations in CAD-CAM milling bur properties, particularly those related to their frequent use.
Topics: Computer-Aided Design; Polymethyl Methacrylate; Color; Materials Testing; Dental Materials; Surface Properties; Humans
PubMed: 38807102
DOI: 10.1186/s12903-024-04350-2 -
Scientific Reports May 2024Patients on hemodialysis (HD) have a high risk of death from COVID-19. We evaluated the humoral and cell-mediated immune response to BNT162b2 (Pfizer-BioNTech) vaccine...
Patients on hemodialysis (HD) have a high risk of death from COVID-19. We evaluated the humoral and cell-mediated immune response to BNT162b2 (Pfizer-BioNTech) vaccine in HD patients, comparing HD with Poly-methyl-methacrylate (PMMA) and HD with Polysulphone (PS). Samples were collected before vaccination (T0) and 14-days after the 2ndvaccine (T2) in a TG (TG, n = 16-Foggia) and in a VG (CG, n = 36-Novara). Anti-SARS-CoV-2-Ig were titrated in the cohort 2-weeks after the 2nddose of vaccine. In the Testing-Group, serum neutralizing antibodies (NAb) were assayed and PBMCs isolated from patients were thawed, counted and stimulated with SARS-CoV-2 IGRA stimulation tube set. All patients had a positive ab-response, except in a case. PMMA-patients had higher levels of anti-SARS-CoV-2 IgG (p = 0.031); VG data confirmed these findings (p < 0.05). NAb evaluation: PMMA patients passed the positive cut-off value, while in PS group only only 1/8 patient did not respond. PMMA patients showed higher percentages of anti-SARS-CoV-2 S1/RBD-Ig after a complete vaccine schedule (p = 0.028). Interferon-gamma release: PMMA patients showed significantly higher release of IFNγ (p = 0.014). The full vaccination course provided sufficient protection against SARS-CoV-2 across the entire cohort, regardless of dialyzer type. After vaccination, PMMA patients show a better immune response, both humoral and cellular, at the end of the vaccination course than PS patients.
Topics: Humans; Renal Dialysis; Male; Female; Aged; COVID-19; Middle Aged; Antibodies, Viral; Immunity, Humoral; BNT162 Vaccine; Antibodies, Neutralizing; SARS-CoV-2; Immunity, Cellular; Polymethyl Methacrylate; COVID-19 Vaccines; Cohort Studies; Immunoglobulin G; Aged, 80 and over; Vaccination; Polymers; Sulfones
PubMed: 38806543
DOI: 10.1038/s41598-024-62044-9 -
Clinical and Experimental Dental... Jun 2024To study the feasibility of using poly methyl methacrylate (PMMA) filament and fused deposition modeling (FDM) to manufacture denture bases via the development of a...
OBJECTIVE
To study the feasibility of using poly methyl methacrylate (PMMA) filament and fused deposition modeling (FDM) to manufacture denture bases via the development of a study that considers both conventional and additive-based manufacturing techniques.
MATERIALS AND METHODS
Five sample groups were compared: heat and cold cured acrylic resins, CAD/CAM milled PMMA, 3D-printed PMMA (via FDM), and 3D-printed methacrylate resin (via stereolithography, SLA). All groups were subjected to mechanical testing (flexural strength, impact strength, and hardness), water sorption and solubility tests, a tooth bonding test, microbiological assessment, and accuracy of fit measurements. The performance of sample groups was referred to ISO 20795-1 and ISO/TS 19736. The data was analyzed using one-way ANOVA.
RESULTS
Samples manufactured using FDM performed within ISO specifications for mechanical testing, water sorption, and solubility tests. However, the FDM group failed to achieve the ISO requirements for the tooth bonding test. FDM samples presented a rough surface finish which could ultimately encourage an undesirable high level of microbial adhesion. For accuracy of fit, FDM samples showed a lower degree of accuracy than existing materials.
CONCLUSIONS
Although FDM samples were a cost-effective option and were able to be quickly manufactured in a reproducible manner, the results demonstrated that current recommended testing regimes for conventionally manufactured denture-based polymers are not directly applicable to additive-manufactured denture base polymers. Therefore, new standards should be developed to ensure the correct implementation of additive manufacturing techniques within denture-based fabrication workflow.
Topics: Denture Bases; Polymethyl Methacrylate; Printing, Three-Dimensional; Computer-Aided Design; Materials Testing; Acrylic Resins; Denture Design; Humans; Feasibility Studies; Dental Materials; Dental Bonding; Surface Properties; Stereolithography; Flexural Strength; Hardness; Solubility
PubMed: 38798134
DOI: 10.1002/cre2.880 -
PloS One 2024Silk fibroin nanoparticles (FNP) have been increasingly investigated in biomedical fields due to their biocompatibility and biodegradability properties. To widen the FNP...
Silk fibroin nanoparticles (FNP) have been increasingly investigated in biomedical fields due to their biocompatibility and biodegradability properties. To widen the FNP versatility and applications, and to control the drug release from the FNP, this study developed the Eudragit S100-functionalized FNP (ES100-FNP) as a pH-responsive drug delivery system, by two distinct methods of co-condensation and adsorption, employing the zwitterionic furosemide as a model drug. The particles were characterized by sizes and zeta potentials (DLS method), morphology (electron microscopy), drug entrapment efficiency and release profiles (UV-Vis spectroscopy), and chemical structures (FT-IR, XRD, and DSC). The ES100-FNP possessed nano-sizes of ∼200-350 nm, zeta potentials of ∼ -20 mV, silk-II structures, enhanced thermo-stability, non-cytotoxic to the erythrocytes, and drug entrapment efficiencies of 30%-60%, dependent on the formulation processes. Interestingly, the co-condensation method yielded the smooth spherical particles, whereas the adsorption method resulted in durian-shaped ones due to furosemide re-crystallization. The ES100-FNP adsorbed furosemide via physical adsorption, followed Langmuir model and pseudo-second-order kinetics. In the simulated oral condition, the particles could protect the drug in the stomach (pH 1.2), and gradually released the drug in the intestine (pH 6.8). Remarkably, in different pH conditions of 6.8, 9.5, and 12, the ES100-FNP could control the furosemide release rates depending on the formulation methods. The ES100-FNP made by the co-condensation method was mainly controlled by the swelling and corrosion process of ES100, and followed the Korsmeyer-Peppas non-Fickian transport mechanism. Whereas, the ES100-FNP made by the adsorption method showed constant release rates, followed the zero-order kinetics, due to the gradual furosemide dissolution in the media. Conclusively, the ES100-FNP demonstrated high versatility as a pH-responsive drug delivery system for biomedical applications.
Topics: Fibroins; Hydrogen-Ion Concentration; Nanoparticles; Furosemide; Drug Delivery Systems; Polymethacrylic Acids; Drug Liberation; Drug Carriers; Particle Size; Animals; Humans; Spectroscopy, Fourier Transform Infrared
PubMed: 38781182
DOI: 10.1371/journal.pone.0303177 -
International Journal of Molecular... Apr 2024The use of temporary resin for provisional restorations is a fundamental step to maintain the position of prepared teeth, to protect the pulpal vitality and the... (Comparative Study)
Comparative Study
The use of temporary resin for provisional restorations is a fundamental step to maintain the position of prepared teeth, to protect the pulpal vitality and the periodontal health as well as the occlusion. The present study aimed at evaluating the biological effects of two resins used in dentistry for temporary restorations, Coldpac (Yates Motloid) and ProTemp 4™ (3M ESPE ™), and their eluates, in an in vitro model of human gingival fibroblasts (hGFs). The activation of the inflammatory pathway NFκB p65/NLRP3/IL-1β induced by the self-curing resin disks was evaluated by real-time PCR, Western blotting and immunofluorescence analysis. The hGFs adhesion on resin disks was investigated by means of inverted light microscopy and scanning electron microscopy (SEM). Our results suggest that hGF cells cultured in adhesion and with eluate derived from ProTemp 4™ (3M ESPE ™) resin evidenced a downregulation in the expression of the inflammatory mediators such as NFκB p65, NLRP3 and IL-1β compared to the cells cultured with Coldpac (Yates Motloid) after 24 h and 1 week of culture. Furthermore, the cells cultured with ProTemp 4™ (3M ESPE ™) after 24 h and 1 week of culture reported a higher cell viability compared to the cells cultured with Coldpac (Yates Motloid), established by MTS cell analysis. Similar results were obtained when hGFs were placed in culture with the eluate derived from ProTemp 4™ (3M ESPE ™) resin which showed a higher cell viability compared to the cells cultured with eluate derived from Coldpac (Yates Motloid). These results highlighted the lower pro-inflammatory action and improved cell biocompatibility of ProTemp 4™ (3M ESPE ™), suggesting a better performance in terms of cells-material interaction.
Topics: Humans; Fibroblasts; Gingiva; Composite Resins; Polymethyl Methacrylate; Interleukin-1beta; NLR Family, Pyrin Domain-Containing 3 Protein; Cells, Cultured; Transcription Factor RelA; Cell Adhesion
PubMed: 38732100
DOI: 10.3390/ijms25094880 -
Effects of hexagonal boron nitride on mechanical properties of bone cement (Polymethylmethacrylate).Joint Diseases and Related Surgery Feb 2024The aim of this study was to investigate the effects of adding hexagonal boron nitride at four different concentrations to polymethylmethacrylate (PMMA) bone cement,...
OBJECTIVES
The aim of this study was to investigate the effects of adding hexagonal boron nitride at four different concentrations to polymethylmethacrylate (PMMA) bone cement, which is commonly used in orthopedic surgeries, on the mechanical properties and microarchitecture of the bone cement.
MATERIALS AND METHODS
The study included an unaltered control group and groups containing four different concentrations (40 g of bone cement with 0.5 g, 1 g, 1.5 g, 2 g) of hexagonal boron nitride. The samples used for mechanical tests were prepared at 20±2ºC in operating room conditions, using molds in accordance with the test standards. As a result of the tests, the pressure values at which the samples deformed were determined from the load-deformation graphs, and the megapascal (MPa) values at which the samples exhibited strength were calculated.
RESULTS
The samples with 0.5 g boron added to the bone cement had significantly increased mechanical strength, particularly in the compression test. In the group where 2 g boron was added, it was noted that, compared to the other groups, the strength pressure decreased and the porosity increased. The porosity did not change particularly in the group where 0.5 g boron was added.
CONCLUSION
Our study results demonstrate that adding hexagonal boron nitride (HBN) to bone cement at a low concentration (0.5 g / 40 g PPMA) significantly increases the mechanical strength in terms of MPa (compression forces) without adversely affecting porosity. However, the incorporation of HBN at higher concentrations increases porosity, thereby compromising the biomechanical properties of the bone cement, as evidenced by the negative impact on compression and four-point bending tests. Boron-based products have gained increased utilization in the medical field, and HBN is emerging as a promising chemical compound, steadily growing in significance.
Topics: Boron Compounds; Polymethyl Methacrylate; Bone Cements; Materials Testing; Porosity; Compressive Strength; Stress, Mechanical
PubMed: 38727113
DOI: 10.52312/jdrs.2024.1513 -
ACS Sensors May 2024In this study, we demonstrate whole blood immunoassays using a microfluidic device optimized for conducting rapid and multiplexed fluorescence-linked immunoassays. The...
In this study, we demonstrate whole blood immunoassays using a microfluidic device optimized for conducting rapid and multiplexed fluorescence-linked immunoassays. The device is capable of handling whole blood samples without any preparatory treatment. The three-dimensional channels in poly(methyl methacrylate) are designed to passively load bodily fluids and, due to their linearly tapered profile, facilitate size-dependent immobilization of biofunctionalized particles. The channel geometry is optimized to allow for the unimpeded flow of cellular constituents such as red blood cells (RBCs). Additionally, to make the device easier to operate, the biofunctionalized particles are pretrapped in a first step, and the channel is dried under vacuum, after which it can be loaded with the biological sample. This novel approach and design eliminated the need for traditionally laborious steps such as filtering, incubation, and washing steps, thereby substantially simplifying the immunoassay procedures. Moreover, by leveraging the shallow device dimensions, we show that sample loading to read-out is possible within 5 min. Our results also show that the presence of RBCs does not compromise the sensitivity of the assays when compared to those performed in a pure buffer solution. This highlights the practical adaptability of the device for simple and rapid whole-blood assays. Lastly, we demonstrate the device's multiplexing capability by pretrapping particles of different sizes, each functionalized with a different antigen, thus enabling the performance of multiplexed on-chip whole-blood immunoassays, showcasing the device's versatility and effectiveness toward low-cost, simple, and multiplexed sensing of biomarkers and pathogens directly in whole blood.
Topics: Humans; Immunoassay; Microfluidic Analytical Techniques; Erythrocytes; Lab-On-A-Chip Devices; Polymethyl Methacrylate
PubMed: 38687557
DOI: 10.1021/acssensors.4c00153 -
Physics in Medicine and Biology May 2024. Prompt gamma timing (PGT) uses the detection time of prompt gammas emitted along the range of protons in proton radiotherapy to verify the position of the Bragg peak...
. Prompt gamma timing (PGT) uses the detection time of prompt gammas emitted along the range of protons in proton radiotherapy to verify the position of the Bragg peak (BP). Cherenkov detectors offer the possibility of enhanced signal-to-noise ratio (SNR) due to the inherent physics of Cherenkov emission which enhances detection of high energy prompt gamma rays relative to other induced uncorrelated signals. In this work, the PGT technique was applied to 3 semiconductor material slabs that emit only Cherenkov light for use in a full scale system: a 3 × 3 × 20 mmTlBr, a 12 × 12 × 12 mmTlBr, and a 5 × 5 × 5 mmTlCl.. A polymethyl methacrylate (PMMA) target was exposed to a 67.5 MeV, 0.5 nA proton beam and shifted in 3 mm increments at the Crocker nuclear laboratory (CNL) in Davis, CA, USA. A fast plastic scintillator coupled to a photomultiplier tube (PMT) provided the start reference for the proton time of flight. Time of flight (TOF) distributions were generated using this reference and the gamma-ray timestamp in the Cherenkov detector.. The SNR of the proton correlated peaks relative to the background was 20, 29, and 30 for each of the three samples, respectively. The upper limit of the position resolutions with the TlCl sample were 2 mm, 3 mm, and 5 mm for 30k, 10k, and 5k detected events, respectively. The time distribution of events with respect to the reference reproduced with clarity the periodicity of the beam, implying a very high SNR of the Cherenkov crystals to detect prompt gammas. Background presence from the neutron-induced continuum, prompt gammas from deuterium, or positron activation were not observed. Material choice and crystal dimensions did not seem to affect significantly the outcome of the results.. These results show the high SNR of the pure Cherenkov emitters TlBr and TlCl for the detection of prompt gammas in a proton beam with current of clinical significance and their potential for verifying the proton range. The accuracy in determining shifts of the BP was highly dependent on the number of events acquired, therefore, the performance of these detectors are expected to vary with different beam conditions such as current, pulse repetition, and proton bunch width.
Topics: Gamma Rays; Time Factors; Proton Therapy; Thallium; Lutetium; Protons; Polymethyl Methacrylate
PubMed: 38657638
DOI: 10.1088/1361-6560/ad4304 -
Lab on a Chip May 2024We report the generation of ∼8 nm dual in-plane pores fabricated in a thermoplastic nanoimprint lithography (NIL). These pores were connected in series with...
We report the generation of ∼8 nm dual in-plane pores fabricated in a thermoplastic nanoimprint lithography (NIL). These pores were connected in series with nanochannels, one of which served as a flight tube to allow the identification of single molecules based on their molecular-dependent apparent mobilities (, dual in-plane nanopore sensor). Two different thermoplastics were investigated including poly(methyl methacrylate), PMMA, and cyclic olefin polymer, COP, as the substrate for the sensor both of which were sealed using a low glass transition cover plate (cyclic olefin co-polymer, COC) that could be thermally fusion bonded to the PMMA or COP substrate at a temperature minimizing nanostructure deformation. Unique to these dual in-plane nanopore sensors was two pores flanking each side of the nanometer flight tube (50 × 50 nm, width × depth) that was 10 μm in length. The utility of this dual in-plane nanopore sensor was evaluated to not only detect, but also identify single ribonucleotide monophosphates (rNMPs) by using the travel time (time-of-flight, ToF), the resistive pulse event amplitude, and the dwell time. In spite of the relatively large size of these in-plane pores (∼8 nm effective diameter), we could detect resistive pulse sensing (RPS) single rNMP molecules at a mass load of 3.9 fg, which was ascribed to the unique structural features of the nanofluidic network and the use of a thermoplastic with low relative dielectric constants, which resulted in a low RMS noise level in the open pore current. Our data indicated that the identification accuracy of individual rNMPs was high, which was ascribed to an improved chromatographic contribution to the nano-electrophoresis apparent mobility. With the ToF data only, the identification accuracy was 98.3%. However, when incorporating the resistive pulse sensing event amplitude and dwell time in conjunction with the ToF and analyzed principal component analysis (PCA), the identification accuracy reached 100%. These findings pave the way for the realization of a novel chip-based single-molecule RNA sequencing technology.
Topics: Nanopores; Ribonucleotides; Temperature; Polymethyl Methacrylate
PubMed: 38656267
DOI: 10.1039/d3lc01062g