Optimizing Binding Site Spacing in Fluidic Self-Assembly for Enhanced Microchip Integration Density.Micromachines Feb 2024This manuscript presents a comprehensive study on the assembly of microchips using fluidic self-assembly (FSA) technology, with a focus on optimizing the spacing between...
This manuscript presents a comprehensive study on the assembly of microchips using fluidic self-assembly (FSA) technology, with a focus on optimizing the spacing between binding sites to improve yield and assembly. Through a series of experiments, we explored the assembly of microchips on substrates with varying binding site spacings, revealing the impact of spacing on the rate of undesired chip assembly across multiple sites. Our findings indicate a significant reduction in incorrect assembly rates as the spacing increases beyond a critical threshold of 140 μm. This study delves into the mechanics of chip alignment within the fluid medium, hypothesizing that the extent of the alloy's grip on the chips at different spacings influences assembly outcomes. By analyzing cases of undesired assembly, we identified the relationship between binding site spacing and the area of chip contact, demonstrating a decrease in the combined left and right areas of chips as the spacing increases. The results highlight a critical spacing threshold, which, when optimized, could significantly enhance the efficiency and precision of microchip assembly processes using FSA technology. This research contributes to the field of microcomponent assembly, offering insights into achieving higher integration densities and precision in applications, such as microLED displays and augmented reality (AR) devices.
PubMed: 38542547
DOI: 10.3390/mi15030300 -
Cureus Jan 2024Fistula formation between the urinary tract and the arterial system is very rare, and usually involves the ureter and the adjacent iliac vessels. Communication of the...
Fistula formation between the urinary tract and the arterial system is very rare, and usually involves the ureter and the adjacent iliac vessels. Communication of the ureter with the aorta has been described a few times worldwide, and most of them had a fatal outcome. In our case, a 79-year-old man had a history of total cystectomy for malignancy and diversion of both ureters to a single site in the right hypogastrium with the left one crossing over the aorta. He was admitted elsewhere several times for intermittent hematuria, and four months ago the diagnosis of communication of the left ureter with a mycotic aortic pseudoaneurysm was made. He was then referred to an interventional radiologist who sealed the communication. He was admitted to our hospital four months later in a state of hypovolemic shock and massive hematuria. In lack of information, it seemed to us that he had been treated with endovascular aneurysm repair (EVAR) for uretero-aortic communication, and was experiencing a regression because of endoleak formation. We attempted to treat him as type I endoleak with a proximal extension, and upon failure, with distal extensions, but finally we had to 'build' the entire previous graft from the inside to achieve hemodynamic stability. Our patient remained stable, without endoleak on the post-intervention computed tomography angiography (CTA). Post-operatively, we discovered that the initial operation was the formation of a bifurcated graft with multiple bare stents and coil embolization through them. This was done in an attempt to avoid material infection by the mycotic aneurysm. This is an example of a case where 'things got rough' in a lack of information on patients' medical records. Maybe the time has come to adopt the concept of implanting microchips into humans which would enable doctors to access their medical records. This will only serve as a tool for the benefit of the suffering patients, especially when we are dealing with life-threatening situations with no time to be lost.
PubMed: 38425616
DOI: 10.7759/cureus.53215 -
Medicina (Kaunas, Lithuania) Sep 2023: is a prevalent bacterium capable of inducing various infections, including skin and soft tissue infections, bloodstream infections, pneumonia, and surgical site... (Review)
Review
: is a prevalent bacterium capable of inducing various infections, including skin and soft tissue infections, bloodstream infections, pneumonia, and surgical site infections. The emergence of antimicrobial resistance in , particularly methicillin-resistant , has raised substantial concerns within global healthcare settings. Prior to antibiotic prescription, the ideal approach is antimicrobial susceptibility testing (AST); however, this is frequently perceived as excessively complex and time-intensive. Lab-on-a-chip (LOC) technology holds promise in addressing these challenges and advancing fundamental microbiological research while also aiding in the development of therapeutic strategies. This systematic review aims to evaluate the potential utility of LOC for AST of . : This study adhered to the PRISMA guidelines. Various databases, including SCOPUS, PubMed/MEDLINE, SCIELO, and LILACS, in addition to gray literature sources, were employed in the review process. : Sixteen studies were included in this systematic review. All these studies detailed the effectiveness, rapidity, and predictability of LOC systems for assessing susceptibility to various antibiotics. When comparing the LOC approach to traditional manual methods, it was evident that LOC requires a minimal quantity of reagents. Furthermore, most studies reported that the entire LOC procedure took 10 min to 7 h, with results being equally accurate as those obtained through traditional AST protocols. : The potential application of LOC for AST of is emphasized by its ability to provide rapid access to minimum inhibitory concentration data, which can substantially aid in selecting the most suitable antibiotics and dosages for treating challenging infections caused by this microorganism. Moreover, the rapid AST facilitated by LOC holds promise for enhancing the appropriateness and efficacy of therapy in clinical settings.
Topics: Humans; Staphylococcus aureus; Methicillin-Resistant Staphylococcus aureus; Anti-Bacterial Agents; Staphylococcal Infections; Lab-On-A-Chip Devices
PubMed: 37893437
DOI: 10.3390/medicina59101719 -
Biochip Journal Apr 2023A novel integrated detection system that introduces a paper-chip-based molecular detection strategy into a polydimethylsiloxane (PDMS) microchip and temperature control...
UNLABELLED
A novel integrated detection system that introduces a paper-chip-based molecular detection strategy into a polydimethylsiloxane (PDMS) microchip and temperature control system was developed for on-site colorimetric detection of DNA. For the paper chip-based detection strategy, a padlock probe DNA (PLP)-mediated rolling circle amplification (RCA) reaction for signal amplification and a radial flow assay according to the Au-probe labeling strategy for visualization were optimized and applied for DNA detection. In the PDMS chip, the reactions for ligation of target-dependent PLP, RCA, and labeling were performed one-step under isothermal temperature in a single chamber, and one drop of the final reaction solution was loaded onto the paper chip to form a radial colorimetric signal. To create an optimal analysis environment, not only the optimization of molecular reactions for DNA detection but also the chamber shape of the PDMS chip and temperature control system were successfully verified. Our results indicate that a detection limit of 14.7 nM of DNA was achieved, and non-specific DNAs with a single-base mismatch at the target DNA were selectively discriminated. This integrated detection system can be applied not only for single nucleotide polymorphism identification, but also for pathogen gene detection. The adoption of inexpensive paper and PDMS chips allows the fabrication of cost-effective detection systems. Moreover, it is very suitable for operation in various resource-limited locations by adopting a highly portable and user-friendly detection method that minimizes the use of large and expensive equipment.
SUPPLEMENTARY INFORMATION
The online version contains supplementary material available at 10.1007/s13206-023-00101-7.
PubMed: 37363267
DOI: 10.1007/s13206-023-00101-7 -
Scientific Reports May 2023It is estimated that carbon emissions should reach net-zero by 2050 to meet important climate targets. Carbon capture is likely necessary to reach these targets,...
It is estimated that carbon emissions should reach net-zero by 2050 to meet important climate targets. Carbon capture is likely necessary to reach these targets, requiring a long-term storage solution such as geological carbon sequestration. However, as with any subsurface activity, leakage can occur, potentially impacting groundwater quality near the storage site. Rapid detection is essential to mitigate damage to this resource. Since CO will acidify groundwater, the concentrations of acid soluble minerals and associated cations will increase. Thus, an in-situ, real-time element analysis system based on laser-induced breakdown spectroscopy (LIBS) is under development to monitor these elements. The system splits the traditional LIBS system into a miniature, all-optical sensor head built around a passively Q-switch laser fiber coupled to a control unit. Previous work has validated the LIBS technique for use at high pressure as well as the split system design. In this work, a fieldable prototype sensor is developed and tested in an onsite monitoring well where trace elements concentrations (approx. 0-3 ppm) were tracked over 20 days. These concentrations varied in response to local rainfall, diluting with increased rain, demonstrating the ability of a LIBS-based sensor to track trace elements under real-world conditions.
PubMed: 37160918
DOI: 10.1038/s41598-023-32788-x -
Biosensors Feb 2023The detection of pathogens in food substances is of crucial concern for public health and for the safety of the natural environment. Nanomaterials, with their high... (Review)
Review
The detection of pathogens in food substances is of crucial concern for public health and for the safety of the natural environment. Nanomaterials, with their high sensitivity and selectivity have an edge over conventional organic dyes in fluorescent-based detection methods. Advances in microfluidic technology in biosensors have taken place to meet the user criteria of sensitive, inexpensive, user-friendly, and quick detection. In this review, we have summarized the use of fluorescence-based nanomaterials and the latest research approaches towards integrated biosensors, including microsystems containing fluorescence-based detection, various model systems with nano materials, DNA probes, and antibodies. Paper-based lateral-flow test strips and microchips as well as the most-used trapping components are also reviewed, and the possibility of their performance in portable devices evaluated. We also present a current market-available portable system which was developed for food screening and highlight the future direction for the development of fluorescence-based systems for on-site detection and stratification of common foodborne pathogens.
Topics: Food Safety; Nanostructures; Antibodies; Biosensing Techniques
PubMed: 36832016
DOI: 10.3390/bios13020249 -
Advanced Science (Weinheim,... Jan 2023Most multiplex nucleic acids detection methods require numerous reagents and high-priced instruments. The emerging clustered regularly interspaced short palindromic...
Most multiplex nucleic acids detection methods require numerous reagents and high-priced instruments. The emerging clustered regularly interspaced short palindromic repeats (CRISPR)/Cas has been regarded as a promising point-of-care (POC) strategy for nucleic acids detection. However, how to achieve CRISPR/Cas multiplex biosensing remains a challenge. Here, an affordable means termed CRISPR-RDB (CRISPR-based reverse dot blot) for multiplex target detection in parallel, which possesses the advantages of high sensitivity and specificity, cost-effectiveness, instrument-free, ease to use, and visualization is reported. CRISPR-RDB integrates the trans-cleavage activity of CRISPR-Cas12a with a commercial RDB technique. It utilizes different Cas12a-crRNA complexes to separately identify multiple targets in one sample and converts targeted information into colorimetric signals on a piece of accessible nylon membrane that attaches corresponding specific-oligonucleotide probes. It has demonstrated that the versatility of CRISPR-RDB by constructing a four-channel system to simultaneously detect influenza A, influenza B, respiratory syncytial virus, and SARS-CoV-2. With a simple modification of crRNAs, the CRISPR-RDB can be modified to detect human papillomavirus, saving two-thirds of the time compared to a commercial PCR-RDB kit. Further, a user-friendly microchip system for convenient use, as well as a smartphone app for signal interpretation, is engineered. CRISPR-RDB represents a desirable option for multiplexed biosensing and on-site diagnosis.
Topics: Humans; COVID-19; CRISPR-Cas Systems; Influenza, Human; Nylons; SARS-CoV-2; RNA, Guide, CRISPR-Cas Systems
PubMed: 36442853
DOI: 10.1002/advs.202204689 -
Bioengineering (Basel, Switzerland) Oct 2022With the evolution of the pandemic caused by the Coronavirus disease of 2019 (COVID-19), reverse transcriptase-polymerase chain reactions (RT-PCR) have invariably been a...
With the evolution of the pandemic caused by the Coronavirus disease of 2019 (COVID-19), reverse transcriptase-polymerase chain reactions (RT-PCR) have invariably been a golden standard in clinical diagnosis. Nevertheless, the traditional polymerase chain reaction (PCR) is not feasible for field application due to its drawbacks, such as time-consuming and laboratory-based dependence. To overcome these challenges, a microchip-based ultrafast PCR system called SWM-02 was proposed to make PCR assay in a rapid, portable, and low-cost strategy. This novel platform can perform 6-sample detection per run using multiple fluorescent channels and complete an ultrafast COVID-19 RT-PCR test within 40 min. Here, we evaluated the performance of the microdevice using the gradient-diluted COVID-19 reference samples and commercial PCR kit and determined its limit-of-detection (LoD) as 500 copies/mL, whose variation coefficients for the nucleocapsid (N) gene and open reading frame 1 ab region (ORF1ab) gene are 1.427% and 0.7872%, respectively. The system also revealed an excellent linear correlation between cycle threshold (Ct) values and dilution factors (R2 > 0.99). Additionally, we successfully detected the target RNAs and internal gene in the clinical samples by fast PCR, which shows strong consistency with conventional PCR protocol. Hence, with compact dimension, user-friendly design, and fast processing time, SWM-02 has the capability of offering timely and sensitive on-site molecular diagnosis for prevention and control of pathogen transmission.
PubMed: 36290516
DOI: 10.3390/bioengineering9100548 -
Frontiers in Bioengineering and... 2022In oral and maxillofacial bone reconstruction, autografts from the iliac crest represent the gold standard due to their superior clinical performance, compared to...
In oral and maxillofacial bone reconstruction, autografts from the iliac crest represent the gold standard due to their superior clinical performance, compared to autografts derived from other extraoral regions. Thus, the aim of our study was to identify putative differences between osteoblasts derived from alveolar (hOB-A) and iliac crest (hOB-IC) bone of the same donor (nine donors) by means of their molecular properties in 2D and 3D culture. We thereby focused on the gene expression of biomarkers involved in osteogenic differentiation, matrix formation and osteoclast modulation. Furthermore, we examined the transcriptional response to Vit.D3 in hOB-A and hOB-IC. Our results revealed different modulation modes of the biomarker expression in osteoblasts, namely cell origin/bone entity-dependent, and culture configuration- and/or time-dependent modulations. SEMA3A, SPP1, BGLAP and PHEX demonstrated the strongest dependence on cell origin. With respect to Vit.D3-effects, BGLAP, SPP1 and ALPL displayed the highest Vit.D3-responsiveness. In this context we demonstrated that the transcriptional Vit.D3-response concerning SPP1 and ALPL in human osteoblasts depended on the cell origin. The results indicate a higher bone remodeling activity of iliac crest than alveolar osteoblasts and support the growing evidence that a high osteoclast activity at the host-/donor bone interface may support graft integration.
PubMed: 36246375
DOI: 10.3389/fbioe.2022.918866 -
Sensors (Basel, Switzerland) Jul 2022The Industrial Internet of Things (IIoT) paradigm represents a significant leap forward for sensor networks, potentially enabling wide-area and innovative measurement...
The Industrial Internet of Things (IIoT) paradigm represents a significant leap forward for sensor networks, potentially enabling wide-area and innovative measurement systems. In this scenario, smart sensors might be equipped with novel low-power and long range communication technologies to realize a so-called low-power wide-area network (LPWAN). One of the most popular representative cases is the LoRaWAN (Long Range WAN) network, where nodes are based on the widespread LoRa physical layer, generally optimized to minimize energy consumption, while guaranteeing long-range coverage and low-cost deployment. Additive manufacturing is a further pillar of the IIoT paradigm, and advanced measurement capabilities may be required to monitor significant parameters during the production of artifacts, as well as to evaluate environmental indicators in the deployment site. To this end, this study addresses some specific LoRa-based smart sensors embedded within artifacts during the early stage of the production phase, as well as their behavior once they have been deployed in the final location. An experimental evaluation was carried out considering two different LoRa end-nodes, namely, the Microchip RN2483 LoRa Mote and the Tinovi PM-IO-5-SM LoRaWAN IO Module. The final goal of this research was to assess the effectiveness of the LoRa-based sensor network design, both in terms of suitability for the aforementioned application and, specifically, in terms of energy consumption and long-range operation capabilities. Energy optimization, battery life prediction, and connectivity range evaluation are key aspects in this application context, since, once the sensors are embedded into artifacts, they will no longer be accessible.
Topics: Artifacts; Electric Power Supplies; Monitoring, Physiologic
PubMed: 35897970
DOI: 10.3390/s22155466