-
Scientific Reports Jun 2022Antenatal classes have evolved considerably and include now a discussion of the parents' birth plan. Respecting this plan normally results in a better childbirth...
Antenatal classes have evolved considerably and include now a discussion of the parents' birth plan. Respecting this plan normally results in a better childbirth experience, an important protective factor of post-traumatic stress disorder following childbirth (PTSD-FC). Antenatal class attendance may thus be associated with lower PTSD-FC rates. This cross-sectional study took place at a Swiss university hospital. All primiparous women who gave birth to singletons from 2018 to 2020 were invited to answer self-reported questionnaires. Data for childbirth experience, symptoms of PTSD-FC, neonatal, and obstetrical outcomes were compared between women who attended (AC) or not (NAC) antenatal classes. A total of 794/2876 (27.6%) women completed the online questionnaire. Antenatal class attendance was associated with a poorer childbirth experience (p = 0.03). When taking into account other significant predictors of childbirth experience, only induction of labor, use of forceps, emergency caesarean, and civil status remained in the final model of regression. Intrusion symptoms were more frequent in NAC group (M = 1.63 versus M = 1.11, p = 0.02). Antenatal class attendance, forceps, emergency caesarean, and hospitalisation in NICU remained significant predictors of intrusions for PTSD-FC. Use of epidural, obstetrical, and neonatal outcomes were similar for AC and NAC.
Topics: Female; Humans; Infant, Newborn; Pregnancy; Cross-Sectional Studies; Delivery, Obstetric; Labor, Obstetric; Parturition; Stress Disorders, Post-Traumatic; Surveys and Questionnaires
PubMed: 35739298
DOI: 10.1038/s41598-022-14508-z -
Singapore Medical Journal May 2023There has been a global decrease in operative vaginal deliveries, with a marked shift towards the vacuum extractor. However, little is known about the trends in...
INTRODUCTION
There has been a global decrease in operative vaginal deliveries, with a marked shift towards the vacuum extractor. However, little is known about the trends in operative vaginal delivery in Singapore.
METHODS
A retrospective study was conducted on all operative vaginal deliveries performed from 2012 to 2017 at Singapore General Hospital (SGH). Maternal outcomes in terms of postpartum haemorrhage and obstetric anal sphincter injuries were compared between forceps- and vacuum-assisted deliveries. Neonatal outcomes in terms of neonatal intensive care unit (NICU) admission and clinically significant neonatal events were compared. The instrument preference of obstetricians was analysed.
RESULTS
A total of 906 consecutive operative vaginal deliveries were included in the study, comprising 461 forceps- and 445 vacuum-assisted deliveries. The rate of operative vaginal delivery was maintained at approximately 10% from 2012 to 2017. Neonatal cephalohematomas were more common after vacuum-assisted deliveries. Other maternal and neonatal outcomes did not differ significantly between the two groups. Clinically significant neonatal events were mostly due to shoulder dystocia, whereas all cases of NICU admissions were not directly related to the mode of delivery. Obstetricians' choice of instrument appeared to reflect personal preference and was not affected by the year of graduation.
CONCLUSION
The rates of neonatal and maternal morbidity were low at SGH. Overall instrument use of forceps and vacuum was balanced, and proficiency in both was demonstrated by all operators. Operative vaginal delivery remains an essential skill in facilitating safe vaginal delivery, which should be maintained to keep Caesarean section rates in check.
Topics: Infant, Newborn; Pregnancy; Humans; Female; Cesarean Section; Retrospective Studies; Vacuum Extraction, Obstetrical; Hospitals, General; Obstetrical Forceps; Delivery, Obstetric
PubMed: 35706407
DOI: 10.11622/smedj.2022069 -
SAGE Open Medical Case Reports 2022Chronic irritation of bladder by urinary bladder calculus is a known risk factor for bladder cancer. The use of Wrigley's obstetrical forceps in general surgical...
Chronic irritation of bladder by urinary bladder calculus is a known risk factor for bladder cancer. The use of Wrigley's obstetrical forceps in general surgical practice is a rare event. Herein, we report a case of a giant urinary bladder calculus which was removed by Wrigley's obstetrical forceps during open cystolithotomy. The bladder biopsy showed squamous cell carcinoma of the bladder. With this report, we aim to create an awareness among surgeons about the role of the Wrigley's obstetrical forceps during open cystolithotomy, and the role of taking urinary bladder biopsy from chronically inflamed/unhealthy sites.
PubMed: 35449528
DOI: 10.1177/2050313X221091411 -
BMC Pregnancy and Childbirth Jan 2022The potential protective effect of mediolateral episiotomy for obstetrical anal sphincter injuries (OASIs) remains controversial during operative vaginal delivery... (Observational Study)
Observational Study
Mediolateral episiotomy and risk of obstetric anal sphincter injuries and adverse neonatal outcomes during operative vaginal delivery in nulliparous women: a propensity-score analysis.
BACKGROUND
The potential protective effect of mediolateral episiotomy for obstetrical anal sphincter injuries (OASIs) remains controversial during operative vaginal delivery because of the difficulties to take into account the risk factors and clinical conditions at delivery; in addition, little is known about the potential benefits of mediolateral episiotomy on neonatal outcomes. The objectives were to investigate the associations between mediolateral episiotomy and both OASIs and neonatal outcomes, using propensity scores.
METHODS
We performed a retrospective population-based observational study from a perinatal registry that includes all births in a French region between 2010 and 2017. All nulliparous women with singleton pregnancy delivering by operative vaginal deliveries at 37 weeks gestational age or later were included. Inverse-probability-of-treatment weighting with propensity scores was used to minimize indication bias. OASIs was defined as third and fourth-degree tears according to Royal College of Obstetricians and Gynecologists. Two neonatal outcomes were studied: condition at birth (5-min Apgar score less than 7 and/or umbilical artery pH less than 7.10), and admission to neonatal intensive care unit.
RESULTS
The study population consisted of 7589 women; 2880 (38.0%) received mediolateral episiotomy. After applying propensity scores, episiotomy was associated with a lower rate of OASIs in forceps/spatula delivery (2.3 vs 6.8%, Risk Ratio (RR) 0.38, 95% Confidence Interval (CI) 0.28-0.52) and in vacuum delivery (1.3 vs 3.4%, RR 0.27, 95% CI 0.20-0.38) as compared with no episiotomy. Mediolateral episiotomy was associated with better condition at birth in case of forceps/spatula delivery (4.5 vs 8.8%, RR 0.56, 95% CI 0.39-0.81). In cases of fetal distress (40.7%), mediolateral episiotomy was associated with better condition of infant at birth in women who delivered by forceps/spatula (4.2 vs 13.5%, RR 0.52, 95% CI 0.31-0.89). No association was found with neonatal unit admission (RR 0.93, 95% CI 0.50-1.74).
CONCLUSIONS
Use of mediolateral episiotomy was associated with a lower rate of OASIs during operative vaginal delivery, and in infants it was associated with better condition at birth following forceps/spatula delivery.
Topics: Anal Canal; Apgar Score; Delivery, Obstetric; Episiotomy; Female; Fetal Distress; France; Humans; Infant, Newborn; Intensive Care Units, Neonatal; Odds Ratio; Parity; Pregnancy; Propensity Score; Retrospective Studies
PubMed: 35045812
DOI: 10.1186/s12884-022-04396-6 -
CMAJ : Canadian Medical Association... Jan 2022Operative vaginal delivery (OVD) is considered safe if carried out by trained personnel. However, opportunities for training in OVD have declined and, given these shifts...
BACKGROUND
Operative vaginal delivery (OVD) is considered safe if carried out by trained personnel. However, opportunities for training in OVD have declined and, given these shifts in practice, the safety of OVD is unknown. We estimated incidence rates of trauma following OVD in Canada, and quantified variation in trauma rates by instrument, region, level of obstetric care and institutional OVD volume.
METHODS
We conducted a cohort study of all singleton, term deliveries in Canada between April 2013 and March 2019, excluding Quebec. Our main outcome measures were maternal trauma (e.g., obstetric anal sphincter injury, high vaginal lacerations) and neonatal trauma (e.g., subgaleal hemorrhage, brachial plexus injury). We calculated adjusted and stabilized rates of trauma using mixed-effects logistic regression.
RESULTS
Of 1 326 191 deliveries, 38 500 (2.9%) were attempted forceps deliveries and 110 987 (8.4%) were attempted vacuum deliveries. The maternal trauma rate following forceps delivery was 25.3% (95% confidence interval [CI] 24.8%-25.7%) and the neonatal trauma rate was 9.6 (95% CI 8.6-10.6) per 1000 live births. Maternal and neonatal trauma rates following vacuum delivery were 13.2% (95% CI 13.0%-13.4%) and 9.6 (95% CI 9.0-10.2) per 1000 live births, respectively. Maternal trauma rates remained higher with forceps than with vacuum after adjustment for confounders (adjusted rate ratio 1.70, 95% CI 1.65-1.75) and varied by region, but not by level of obstetric care.
INTERPRETATION
In Canada, rates of trauma following OVD are higher than previously reported, irrespective of region, level of obstetric care and volume of OVD among hospitals. These results support a reassessment of OVD safety in Canada.
Topics: Anal Canal; Birth Injuries; Canada; Female; Humans; Incidence; Intracranial Hemorrhages; Lacerations; Neonatal Brachial Plexus Palsy; Obstetric Labor Complications; Obstetrical Forceps; Pelvis; Pregnancy; Skull Fractures; Trauma, Nervous System; Urethra; Urinary Bladder; Vacuum Extraction, Obstetrical; Vagina
PubMed: 35012946
DOI: 10.1503/cmaj.210841 -
Indian Journal of Ophthalmology Dec 2021Obstetrical forceps-induced Descemet membrane tears (FIDMT) are usually encountered during complicated forceps-assisted deliveries. The condition may lead to significant... (Review)
Review
Obstetrical forceps-induced Descemet membrane tears (FIDMT) are usually encountered during complicated forceps-assisted deliveries. The condition may lead to significant visual debilitation in young children and is frequently ignored due to its low incidence. Undue stretch on the Descemet's membrane during the process of forceps-assisted delivery results in their vertical/oblique tear (s), which usually leads to corneal edema in early neonatal life. On its resolution, these residual tears result in visually disabling astigmatism that can lead to dense and recalcitrant amblyopia. Slit-lamp examination, anterior segment optical coherence tomography, specular microscopy, confocal microscopy, and corneal topography and tomography can be employed for its accurate diagnosis. While these can be prevented by improved perinatal care, once diagnosed, they mandate prompt refractive correction and amblyopia therapy to prevent disabling visual deterioration in affected children. In adulthood, medical and surgical management may be planned for symptomatic patients based on coexistent amblyopia as this is the major factor guiding visual prognosis. There is limited comprehensive literature in this regard, and the present review discusses the pathogenesis, clinical features, and recent developments in investigations, management, and outcomes of FIDMT during the last three decades.
Topics: Adult; Astigmatism; Child; Child, Preschool; Corneal Edema; Corneal Topography; Descemet Membrane; Female; Humans; Infant, Newborn; Obstetrical Forceps; Pregnancy
PubMed: 34826970
DOI: 10.4103/ijo.IJO_863_21 -
PloS One 2021Midpelvic vacuum extractions are controversial due to reports of increased risk of maternal and perinatal morbidity and high failure rates. Prospective studies of... (Comparative Study)
Comparative Study
Prospective assessment of vacuum deliveries from midpelvic station in a tertiary care university hospital: Frequency, failure rates, labor characteristics and maternal and neonatal complications.
BACKGROUND
Midpelvic vacuum extractions are controversial due to reports of increased risk of maternal and perinatal morbidity and high failure rates. Prospective studies of attempted midpelvic vacuum outcomes are scarce. Our main aims were to assess frequency, failure rates, labor characteristics, maternal and neonatal complications of attempted midpelvic vacuum deliveries, and to compare labor characteristics and complications between successful and failed midpelvic vacuum deliveries.
STUDY DESIGN
Clinical data were obtained prospectively from all attempted vacuum deliveries (n = 891) over a one-year period with a total of 6903 births (overall cesarean section rate 18.2% (n = 1258). Student's t-test, Mann-Whitney U-test or Chi-square test for group differences were used as appropriate. Odds ratios and 95% confidence intervals are given as indicated. The uni- and multivariable analysis were conducted both as a complete case analysis and with a multiple imputation approach. A p-value of <0.05 was considered statistically significant.
RESULTS
Attempted vacuum extractions from midpelvic station constituted 36.7% (n = 319) of all attempted vacuum extractions (12.9% (n = 891) of all births). Of these 319 midpelvic vacuum extractions, 11.3% (n = 36) failed and final delivery mode was cesarean section in 86.1% (n = 31) and forceps in the remaining 13.9% (n = 5). Successful completion of midpelvic vacuum by 3 pulls or fewer was achieved in 67.1%. There were 3.9% third-degree and no fourth-degree perineal tears. Cup detachments were associated with a significantly increased failure rate (adjusted OR 6.13, 95% CI 2.41-15.56, p< 0.001).
CONCLUSION
In our study, attempted midpelvic vacuum deliveries had relatively low failure rate, the majority was successfully completed within three pulls and they proved safe to perform as reflected by a low rate of third-degree perineal tears. We provide data for nuanced counseling of women on vacuum extraction as a second stage delivery option in comparable obstetric management settings with relatively high vacuum delivery rates and low cesarean section rates.
Topics: Adult; Cesarean Section; Female; Hospitals, University; Humans; Labor Onset; Maternal Age; Obstetric Labor Complications; Obstetrical Forceps; Pregnancy; Prospective Studies; Tertiary Care Centers; Vacuum Extraction, Obstetrical
PubMed: 34784382
DOI: 10.1371/journal.pone.0259926 -
PloS One 2021Induction and augmentation of labor is one of the most common obstetrical interventions. However, this intervention is not free of risks and could cause adverse events,...
Induction and augmentation of labor is one of the most common obstetrical interventions. However, this intervention is not free of risks and could cause adverse events, such as hyperactive uterine contraction, uterine rupture, and amniotic-fluid embolism. Our previous study using a new animal model showed that labor induced with high-dose oxytocin (OXT) in pregnant mice resulted in massive cell death in selective brain regions, specifically in male offspring. The affected brain regions included the prefrontal cortex (PFC), but a detailed study in the PFC subregions has not been performed. In this study, we induced labor in mice using high-dose OXT and investigated neonatal brain damage in detail in the PFC using light and electron microscopy. We found that TUNEL-positive or pyknotic nuclei and Iba-1-positive microglial cells were detected more abundantly in infralimbic (IL) and prelimbic (PL) cortex of the ventromedial PFC (vmPFC) in male pups delivered by OXT-induced labor than in the control male pups. These Iba-1-positive microglial cells were engulfing dying cells. Additionally, we also noticed that in the forceps minor (FMI) of the corpus callosum (CC), the number of TUNEL-positive or pyknotic nuclei and Iba-1-positive microglial cells were largely increased and Iba-1-positive microglial cells phagocytosed massive dying cells in male pups delivered by high-dose OXT-induced labor. In conclusion, IL and PL of the vmPFC and FMI of the CC, were susceptible to brain damage in male neonates after high-dose OXT-induced labor.
Topics: Animals; Animals, Newborn; Calcium-Binding Proteins; Cell Death; Corpus Callosum; Disease Models, Animal; Female; Labor, Induced; Limbic System; Male; Mice, Inbred C57BL; Microfilament Proteins; Microglia; Oxytocin; Phagocytosis; Prefrontal Cortex; Pregnancy; Reproducibility of Results; Mice
PubMed: 34437622
DOI: 10.1371/journal.pone.0256693 -
Acta Obstetricia Et Gynecologica... Nov 2021The objective was to report the role of intrapartum ultrasound examination in affecting maternal and perinatal outcome in women undergoing instrumental vaginal delivery. (Meta-Analysis)
Meta-Analysis
INTRODUCTION
The objective was to report the role of intrapartum ultrasound examination in affecting maternal and perinatal outcome in women undergoing instrumental vaginal delivery.
MATERIAL AND METHODS
MEDLINE, Embase, CINAHL, Google Scholar and ClinicalTrial.gov databases were searched. Inclusion criteria were randomized controlled trials comparing ultrasound assessment of fetal head position vs routine standard care (digital examination) before instrumental vaginal delivery (either vacuum or forceps). The primary outcome was failed instrumental delivery extraction followed by cesarean section. Secondary outcomes were postpartum hemorrhage, 3rd or 4th degree perineal lacerations, episiotomy, prolonged hospital stay, Apgar score<7 at 5 min, umbilical artery pH <7.0 and base excess greater than -12 mEq, admission to neonatal intensive care unit (NICU), shoulder dystocia, birth trauma, a composite score of adverse maternal and neonatal outcome and incorrect diagnosis of fetal head position. Risk of bias was assessed using the Revised Cochrane risk-of-bias tool for randomized trials (RoB-2). The quality of evidence and strength of recommendations were assessed using the Grading of Recommendations Assessment Development and Evaluation (GRADE) methodology. Head-to-head meta-analyses using a random-effect model were used to analyze the data and results are reported as relative risk with their 95% confidence intervals.
RESULTS
Five studies were included (1463 women). There was no difference in the maternal, pregnancy or labor characteristics between the two groups. An ultrasound assessment prior to instrumental vaginal delivery did not affect the cesarean section rate compared with standard care (p = 0.805). Likewise, the risk of composite adverse maternal outcome (p = 0.428), perineal lacerations (p = 0.800), postpartum hemorrhage (p = 0.303), shoulder dystocia (p = 0.862) and prolonged stay in hospital (p = 0.059) were not different between the two groups. Composite adverse neonatal outcome was not different between the women undergoing and those not undergoing ultrasound assessment prior to instrumental delivery (p = 0.400). Likewise, there was no increased risk with abnormal Apgar score (p = 0.882), umbilical artery pH < 7.2 (p = 0.713), base excess greater than -12 (p = 0.742), admission to NICU (p = 0.879) or birth trauma (p = 0.968). The risk of having an incorrect diagnosis of fetal head position was lower when ultrasound was performed before instrumental delivery, with a relative risk of 0.16 (95% confidence interval 0.1-0.3; I :77%, p < 0.001).
CONCLUSIONS
Although ultrasound examination was associated with a lower rate of incorrect diagnoses of fetal head position and station, this did not translate to any improvement of maternal or neonatal outcomes.
Topics: Birth Injuries; Cesarean Section; Extraction, Obstetrical; Female; Humans; Postpartum Hemorrhage; Pregnancy; Pregnancy Outcome; Ultrasonography, Prenatal
PubMed: 34314520
DOI: 10.1111/aogs.14236 -
Journal of Healthcare Engineering 2021Forceps delivery is one of the most important measures to facilitate vaginal delivery. It can reduce the rate of first cesarean delivery. Frustratingly, adverse maternal...
BACKGROUND
Forceps delivery is one of the most important measures to facilitate vaginal delivery. It can reduce the rate of first cesarean delivery. Frustratingly, adverse maternal and neonatal outcomes associated with forceps delivery have been frequently reported in recent years. There are two major reasons: one is that the abilities of doctors and midwives in forceps delivery vary from hospital to hospital and the other one is lack of regulations in the management of forceps delivery. In order to improve the success rate of forceps delivery and reduce the incidence of maternal and neonatal complications, we applied form-based management to forceps delivery under an intelligent medical model. The aim of this work is to explore the clinical effects of form-based management of forceps delivery.
METHODS
Patients with forceps delivery in Maternal and Child Health Hospital Affiliated to Nanchang University were divided into two groups: form-based patients from January 1, 2019, to December 31, 2020, were selected as the study group, while traditional protocol patients from January 1, 2017, to December 31, 2018, were chosen as the control group. Then, we compared the maternal and neonatal outcomes of these two groups.
RESULTS
There were significant differences in the maternal and neonatal adverse outcomes such as rate of postpartum hemorrhage, degree of perineal laceration, and incidence of neonatal facial skin abrasions between the two groups, whereas differences in the incidence of asphyxia and intracranial hemorrhage were not significant.
CONCLUSIONS
Form-based management could help us assess the security of forceps delivery comprehensively, as it could not only improve the success rate of the one-time forceps traction scheme but also reduce the incidence of maternal and neonatal adverse outcomes effectively.
Topics: Cesarean Section; Child; Delivery, Obstetric; Female; Humans; Infant, Newborn; Obstetrical Forceps; Postpartum Hemorrhage; Pregnancy; Vacuum Extraction, Obstetrical
PubMed: 34194686
DOI: 10.1155/2021/9947255