-
PloS One 2024The Vega System® PS (Aesculap AG, Tuttlingen, Germany) is an advanced, third generation fixed implant that aims to mimic natural knee kinematics by optimizing pivotal...
The Vega advanced third generation posterior stabilized total knee arthroplasty system enables the restoration of range of motion for high demanding daily activities - A 5-years follow-up study.
BACKGROUND
The Vega System® PS (Aesculap AG, Tuttlingen, Germany) is an advanced, third generation fixed implant that aims to mimic natural knee kinematics by optimizing pivotal motion while reducing surface stress. This study evaluated mid-term survival and clinical outcomes, including range of motion (ROM) of the modern posterior stabilized implant in order to analyse whether this biomechanically successful implant reaches good results in situ.
METHODS
The first 100 patients to receive the Vega PS System for total knee arthroplasty were invited to take part in this single centre, single surgeon study. Of these, 84 patients were clinically assessed 5-6 years postoperatively. Data which was obtained during this follow-up examination included revision data, range of motion and clinical scores.
RESULTS
The 5-year survival rate for exchange of any component was 97.6%, whereby two patients required replacement of the polyethylene gliding surface. Secondary patella resurfacing was performed in 7 patients. Significantly improved results in comparison to the preoperative state could be obtained at the follow-up: KOOS improved from 39.4 to 78.8, SF-12 PCS improved from 32.1 to 42 SF-12 MCS improved from 46 to 53.8 and patella pain improved from 2.7 to 0.3. The mean ROM of the 84 patients after 5 years was 133.1° and mean total KSS was 189.9.
DISCUSSION & CONCLUSIONS
This study demonstrates a high survival rate of the Vega PS System® and significant improvements in clinical outcomes 5 years after implantation. The obtained mean ROM indicates that this implant provides good flexibility of the knee joint, allowing a high number of activities. However, due to the rate of secondary patella implantation, routine resurfacing of the patella for all PS TKA cases is highly recommended.
CLINICAL TRIALS REGISTRATION
The study was registered at clinicaltrials.gov (NCT02802085).
Topics: Humans; Arthroplasty, Replacement, Knee; Range of Motion, Articular; Female; Male; Aged; Follow-Up Studies; Middle Aged; Knee Prosthesis; Knee Joint; Aged, 80 and over; Activities of Daily Living; Biomechanical Phenomena; Treatment Outcome; Prosthesis Design
PubMed: 38739584
DOI: 10.1371/journal.pone.0302885 -
The Knee May 2024Anterior knee pain (AKP) is one of the reasons for dissatisfaction after total knee replacement (TKR). It may result from patellofemoral joint dysfunction, caused by...
Establishing femoral component rotation using a dynamic tensioner does not improve patellar position after total knee replacement with use of anatomic implants: A case-control study.
BACKGROUND
Anterior knee pain (AKP) is one of the reasons for dissatisfaction after total knee replacement (TKR). It may result from patellofemoral joint dysfunction, caused by improper rotation of implant components. The aim of this study was to analyze patella positioning in patients after standard measured resection TKR and TKR with a use of a dynamic tensioner, and to assess the frequency of AKP, range of motion (ROM), and patient-reported outcome measures 6 weeks and 3 months postoperatively.
METHODS
The study consisted of 127 patients who underwent TKR. Eighty-nine of them treated with use of the dynamic tensioner FUZION formed the study group; the remainder formed the control group. All participants received cemented PERSONA MC without patella resurfacing. All patients had a standard anteroposterior, lateral weight-bearing, long-leg view X-ray and computed tomography examination in 30° of knee flexion following the procedure.
RESULTS
There were no significant differences between the study and the control groups regarding: posterior condylar axis (PCA)-patella angle, surgical transepicondylar axis (sTEA)-patella angle, PCA-sTEA angle, deviation from 90° in PCA-patella, sTEA-patella and PCA-sTEA angles. No significant difference was found in a ratio of obtaining PCA-patella angle deviation of more than 3°. Regarding clinical parameters, statistically and questionablly clinically significant difference in favor of the Study Group was found in Forgotten Joint Score 6 weeks and 3 months post-operativley and ROM 6 weeks post-operatively. However, such difference was not found by analyzing ROM 3 months post-operatively, AKP and Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) scores.
CONCLUSION
Compared with the standard 3° of femoral component external rotation, use of a dynamic tensioner does not allow for more accurate restoration of the patellar facet position with reference to the PCA.
PubMed: 38733872
DOI: 10.1016/j.knee.2024.04.001 -
Journal of Medical Case Reports May 2024People with achondroplasia exhibit distinct physical characteristics, but their cognitive abilities remain within the normal range. The challenges encountered...
BACKGROUND
People with achondroplasia exhibit distinct physical characteristics, but their cognitive abilities remain within the normal range. The challenges encountered during surgical procedures and perioperative care for achondroplastic individuals, are underrepresented in the existing literature.
CASE PRESENTATION
In this report, the management of a 26-year-old North-African achondroplastic male is highlighted. The patient suffered a complete intra-articular distal femur fracture (AO/OTA 33-C1) and an ipsilateral patella fracture (AO/OTA 34-C1). The patient's unusual anatomical variations and the lack of suitable orthopedic implants posed significant surgical challenges, particularly in the context of a resource-limited developing country. Facial and spinal deformities, which are common in patients with achondroplasia, further complicated the anesthetic approach.
CONCLUSIONS
The limited information on operative management of fractures in achondroplastic patients necessitated independent decision-making and diverging from the convenient approach where clear guidance is available in the literature.
Topics: Humans; Adult; Male; Achondroplasia; Femoral Fractures; Patella; Intra-Articular Fractures; Fracture Fixation, Internal
PubMed: 38730409
DOI: 10.1186/s13256-024-04566-4 -
Joint Diseases and Related Surgery Apr 2024The study aims to investigate the relationship between the vastus medialis obliquus (VMO) muscle distal insertion features and patellar chondral lesion presence.
OBJECTIVES
The study aims to investigate the relationship between the vastus medialis obliquus (VMO) muscle distal insertion features and patellar chondral lesion presence.
PATIENTS AND METHODS
This cross-sectional study included a total of 100 patients (18 males, 82 females, mean age 67.2±7.1 years; range, 50 to 86 years) who underwent total knee arthroplasty (TKA). Radiological assessments, including merchant view and standing orthoroentgenograms, were conducted. The current osteoarthritis stage, varus angle, quadriceps angle (Q angle), patella-patellar tendon angle (P-PT angle), congruence angle, and sulcus angle were calculated. The VMO tendon length, muscle fiber angle, tendon insertion width measurements, and patellar chondral lesion localization data were obtained intraoperatively. Grouping was done according to the distal insertion width of the VMO tendon to the medial edge of the patella. The medial rim of the patella was divided into three equal-sized sectors. The first group (Group 1, n=31) consisted of patients who had an insertion from the quadriceps tendon into the upper one-third of the patella. The second group (Group 1, n=48) consisted of patients with a distal insertion expanding into the middle one-third of the patella. The third group (Group 3, n=21) consisted of patients who had a distal insertion extending into the distal third region of the medial patella margin. The patella joint surface was divided into sectors, and the presence and location of cartilage lesions were noted in detail.
RESULTS
The mean tendon insertion width rate was 45.99±16.886% (range, 16.7 to 83.3%). The mean muscle fiber insertion angle was 51.85±11.67º (range, 20º to 80º). The mean tendon length was 12.45±3.289 (range, 4 to 20) mm. There was no significant difference between the mean age, weight, height, body mass index, BMI, fiber angle, tendon length, varus angle, Q angle, sulcus angle, and congruence angle data among the groups. In terms of the P-PT angle, Groups 1 and 2 had a significant relationship (p=0.008). No relationship was found between the mean fiber insertion angle, mean tendon length, or the presence of chondral lesions. There was a statistically significant difference among the groups regarding the presence of chondral lesions. The highest percentage of chondral lesion frequency was observed in Group 3 (95.24%), followed by Group 1 (90.3%) and Group 2 (89.6%), respectively. Compared to the other two groups, Group 3 had a higher average ratio of lesion areas per patient.
CONCLUSION
Our study results demonstrate that the formation and localization of the patellar chondral lesions are affected by the insertion width type of the VMO muscle into the patella. Group 2-type insertion is associated with a lower lesion frequency rate than Groups 1 and 3.
Topics: Humans; Female; Male; Middle Aged; Aged; Quadriceps Muscle; Cross-Sectional Studies; Aged, 80 and over; Patella; Arthroplasty, Replacement, Knee; Osteoarthritis, Knee; Cartilage, Articular; Radiography; Knee Joint
PubMed: 38727112
DOI: 10.52312/jdrs.2024.771 -
Joint Diseases and Related Surgery Feb 2024This study aims to evaluate the inter-observer reliability of fibula-condyle-patella angle measurements and to compare it with other measurement techniques.
OBJECTIVES
This study aims to evaluate the inter-observer reliability of fibula-condyle-patella angle measurements and to compare it with other measurement techniques.
PATIENTS AND METHODS
Between January 01, 2023 and January 31, 2023, a total of 108 patients (20 males, 88 females; mean age: 47.5±12.0 years; range, 18 to 72 years) who underwent X-rays using the fibula-condyle-patella angle, Insall-Salvati, Caton-Deschamps, Blackburne-Pell, and plateau-patella angle (PPA) methods were retrospectively analyzed. Knee lateral radiographs taken in at least 30 degrees of flexion and appropriate rotation were scanned. All measurements were made by two orthopedic surgeons who were blinded to measurement methods.
RESULTS
Right knee patellar height measurements were conducted in 56 patients, while left knee patellar heights were assessed in 52 patients. The highest inter-observer concordance was found in the fibula-condyle-patella angle. The second highest concordance was found in the Insall-Salvati. The highest concordance correlation was found with PPA in the measurements of both researchers.
CONCLUSION
The fibula-condyle-patella angle is a reliable technique with a good inter-observer reliability for measuring patellar height. We believe that this study will inspire future research to establish comprehensive reference values for clinical applications.
Topics: Humans; Female; Male; Fibula; Adult; Patella; Middle Aged; Aged; Retrospective Studies; Adolescent; Young Adult; Reproducibility of Results; Observer Variation; Radiography; Knee Joint
PubMed: 38727111
DOI: 10.52312/jdrs.2024.1553 -
Orthopaedic Journal of Sports Medicine May 2024The Victorian Institute of Sport Assessment-Patella (VISA-P) questionnaire is a widely accepted instrument for measuring the severity of symptoms and pain in patients...
BACKGROUND
The Victorian Institute of Sport Assessment-Patella (VISA-P) questionnaire is a widely accepted instrument for measuring the severity of symptoms and pain in patients having sustained patellar tendinopathy.
PURPOSE
To adapt the VISA-P questionnaire cross-culturally to a traditional Chinese version (VISA-P-Ch) and validate its psychometric properties.
STUDY DESIGN
Cohort study (diagnosis); Level of evidence, 3.
METHODS
The VISA-P questionnaire was adapted to a traditional Chinese version following international recommended guidelines, including translation, synthesis, back translation, revision by expert committee, pretesting, and validation. The psychometric properties were tested in 15 healthy controls and 15 participants with patellar tendinopathy. Face validity was judged by the authors and participants. Known-groups validity was tested by comparing the VISA-P-Ch scores between symptomatic and asymptomatic participants using an independent test. Concurrent validity was determined by comparing the Blazina classification of the participants against VISA-P-Ch scores using the Spearman correlation coefficient. Test-retest reliability was assessed by calculating the intraclass correlation coefficient (ICC) following a 24- to 48-hour interval. Internal consistency was determined by the Cronbach alpha.
RESULTS
The expert committee and participants reported good face validity of the VISA-P-Ch. Significantly higher scores were found in the control group than in the patellar tendinopathy group (98.47 ± 3.04 vs 65 ± 11.9; < .001). Concurrent validity showed a high correlation between VISA-P-Ch and the Blazina classification system ( = -0.899; < .01). The test-retest reliability was excellent (ICC = 0.964). Internal consistency was found to be good for both the first and second assessments (Cronbach α = 0.834 and 0.851).
CONCLUSION
The VISA-P-Ch was proven to be a reliable and valid questionnaire with similar psychometric properties as the original VISA-P.
PubMed: 38726236
DOI: 10.1177/23259671241248165 -
Frontiers in Bioengineering and... 2024The separate vertical wire (SVW) technique and the improved candy box (CB) technique have been proposed for treating inferior pole patellar fractures. However, there is...
Computational evaluation of wire position using separate vertical wire technique and candy box technique for the fixation of inferior pole patellar fractures: a finite element analysis.
The separate vertical wire (SVW) technique and the improved candy box (CB) technique have been proposed for treating inferior pole patellar fractures. However, there is still a lack of clear explanation regarding the location of the wire passing through the patella. Five models of SVW techniques were established in different positions. Finite element analysis was then conducted to determine the optimal bone tunnel position for the SVW technique. Based on these findings, six groups of finite element models were created for CB techniques. The maximum displacement and stress on both the patella and steel wire were compared among these groups under 100-N, 200-N, 300-N, 400-N, and 500-N force loads. The results indicated that, in the SVW technique, the steel wire group near the fracture end of the longitudinal bone tunnel showed minimal displacement and stress on the patella when subjected to different forces. On the other hand, in the CB technique, both the patella and wire experienced minimal stress when a transverse bone tunnel wire was placed near the upper posterior aspect of patella. In conclusion, the SVW technique may require the bone tunnel wire to be positioned near the fractured end of the lower pole of the patella. On the other hand, in CB technique, the transverse bone tunnel wire passing through the patella may be close to its upper posterior aspect. However, further validation is necessary through comprehensive finite element analysis and additional biomechanical experiments.
PubMed: 38720880
DOI: 10.3389/fbioe.2024.1353901 -
Quantitative Imaging in Medicine and... May 2024The newly defined angle, quadriceps-patella angle (QPA), reflects the combined force transmitted to the patella by the quadriceps muscles and patellar tendon. An...
BACKGROUND
The newly defined angle, quadriceps-patella angle (QPA), reflects the combined force transmitted to the patella by the quadriceps muscles and patellar tendon. An increase in QPA may correlate with an increased force on the patella, which is significant in diagnosing patellofemoral instability and pain syndrome. In our study, we examined how various angles and pathologies vary depending on lateral patellar tilt angle (LPTA). QPA and patellar malalignment was investigated. Thus, the importance of understanding patellar malalignment and the research gap.
METHODS
Three hundred and fifty patients who underwent knee magnetic resonance imaging (MRI) examinations were included. The cross-sectional study conducted retrospectively between the years of 2018-2020 in a tertiary care outpatient clinic. Shapiro-Wilk normality, Chi-square, Mann-Whitney-, Spearman correlation and receiver operating characteristic (ROC) curve analysis, statistical tests used for analysis. The patellar tendon length, patellar height, tibial tubercle-trochlear groove distance (TT-TG), patella angle, trochlear sulcus angle, trochlear groove depth (TGD), medial trochlea length (MT), lateral trochlea length (LT), medial trochlear/lateral trochlear length ratio (MT/LT), LPTA, patella-patellar tendon angle (PPTA), QPA, Insall-Salvati index (ISI), medial trochlear inclination (MTI), lateral trochlear inclination (LTI) were among these measurements. In addition, we aim to reveal whether there is a significant relationship between two important angles LPTA and QPA. Whether there is a significant increase in the development of chondromalacia for the patient group with LPTA >5°. We examined how the frequency of chondromalacia changes in the patient group with LPTA >5°.
RESULTS
Two hundred and seventy seven patients included in the study and many measurements were performed on MRI. Fad-pad edema was found to be significantly higher in the group with LPTA <5° (P=0.046). TT-TG distance was significantly higher, TGD and MT were significantly lower in patients with higher LPTA (P=0.001, P=0.002 and P=0.017, respectively). A low level of significant positive correlation was found between QPA and patellar tendon length. There is no significant difference between QPA and PPTA angles between the groups with LPTA <5° and >5° (P=0.503, P=0.188). In the ROC analysis performed to determine the cut-off value, the LPTA value ≤14.2° which significantly predicted the presence of fad-pad edema, had the highest sensitivity and specificity [sensitivity: 76.71%, specificity: 39.90%, area under the curve (AUC): 0.588, P=0.024].
CONCLUSIONS
QPA is independent from many angles of the knee and does not change significantly. As the patellar tendon length increases, QPA angle also increases. In patients with abnormal LPTA, the frequency of TT-TG distance and chondromalacia increased, while TGD and MT decreased. Patients with a low LPTA can be more carefully examined for chondromalacia and fad-pad edema in clinical and MRI examination.
PubMed: 38720855
DOI: 10.21037/qims-23-1592 -
The Archives of Bone and Joint Surgery 2024Medial patellofemoral ligament reconstruction is a standard treatment option for patients with patellar instability. The main purpose of this study was to determine...
Medial patellofemoral ligament reconstruction is a standard treatment option for patients with patellar instability. The main purpose of this study was to determine whether isolated anatomic medial patellofemoral ligament reconstruction using double folded, four-strand plantaris tendon autograft restores patellar stability in adolescent patients. Plantaris tendon autografts were harvested through proximal approach and used in four adolescent patients. A four-strand autograft was prepared in a double-limbed configuration and fixed on the patella and the femur with suture anchors and interference screws, respectively. The mean Kujala score improved significantly from 44 ± 24 SD (range, 19 to 69) points preoperatively to 94 ± 10 SD (range, 78 to 100) points postoperatively (P< 0.001). All patients reported excellent subjective outcomes and returned to their pre-injury level of sporting activities. The use of a four-strand plantaris tendon autograft in isolated anatomic medial patellofemoral ligament reconstruction can restore patellar stability in adolescents.
PubMed: 38716173
DOI: 10.22038/ABJS.2024.75154.3476 -
Cureus Apr 2024Background This study aimed to evaluate the safety and effectiveness of knee exercise within four hours after total knee arthroplasty (TKA) using a single-joint hybrid...
Safety and Efficacy of Early Rehabilitation With Assistance From a Single-Joint Hybrid Assistive Limb in Patients With Total Knee Arthroplasty: A Randomized Controlled Clinical Pilot Study.
Background This study aimed to evaluate the safety and effectiveness of knee exercise within four hours after total knee arthroplasty (TKA) using a single-joint hybrid assistive limb (HAL-SJ). Materials and methods This pilot single-blind randomized controlled trial included participants who underwent TKA for osteoarthritis and were randomly allocated to the early rehabilitation (n = 14) or control rehabilitation (n = 16) group. Knee rehabilitation exercises using the HAL-SJ began within four hours postoperatively in the early group and seven days after surgery in the control group. Knee circumference, range of motion (ROM), pain, muscle strength, and extension lag were assessed before and one and two weeks after surgery. Results Circumferences at 1 and 10 cm from the upper edge of the patella did not differ between the groups before surgery or one week postoperatively. The extension lag and knee flexion ROM after one week were significantly better in the early intervention group than in the control group. However, the quadriceps and hamstring isometric knee strength and pain scores did not differ between the groups at one and two weeks postoperatively. HAL-SJ-related complications were not reported. Conclusion Rehabilitation knee exercises using the HAL-SJ within four hours after TKA improved extension lag and knee flexion ROM without exacerbating knee swelling and pain.
PubMed: 38716002
DOI: 10.7759/cureus.57738