Diagnostics (Basel, Switzerland) May 2024To clinically evaluate how dry eye symptoms in preoperatively diagnosed dry eye patients change with the use of sodium hyaluronate- and dexpanthenol-containing eye drops...
BACKGROUND
To clinically evaluate how dry eye symptoms in preoperatively diagnosed dry eye patients change with the use of sodium hyaluronate- and dexpanthenol-containing eye drops (HYLO CARE (HC), URSAPHARM Arzneimittel GmbH, Saarbruecken, Germany) after cataract surgery. The aim of the study was not to compare different eye drops but to implement standard treatment in patients with dry eye undergoing cataract surgery. The impact of treatment was evaluated using Symptom Assessment Tools for Dry Eye.
METHODS
In this prospective, single-center, open-label clinical trial, 49 patients undergoing cataract surgery were included who showed signs and symptoms of dry eye disease assessed by the Symptom Assessment in Dry Eye (Visual Analogue Scale (VAS)) questionnaire, Ocular Surface Disease Index (OSDI), and fluorescein tear break-up Time (TBUT). Patients were instructed to apply HC three to four times a day for 5 weeks in the operated eye in addition to the standard postoperative topical anti-inflammatory regimen. The primary endpoint was the change in TBUT. Secondary endpoints were the assessment of the subjective symptoms (VAS), corrected distance visual acuity (CDVA), and slit-lamp examination including the corneal staining score, Schirmer test, and intraocular pressure.
RESULTS
At 5 weeks after operation, the mean TBUT increased from 6.42 ± 1.57 s (s) to 7.81 ± 1.83 s in the per-protocol (PP) population ( > 0.001) and from 6.33 ± 1.64 s to 7.71 ± 2.05 s in the intention-to-treat (ITT) population ( < 0.001). There was a statistically significant decrease in all scores ( < 0.05) from the VAS questionnaire except for the tearing score ( = 0.062) at 5 weeks after operation. The mean total corneal staining score also decreased statistically significantly from 8.85 ± 2.49 before operation to 5.61 ± 3.37 at 5 weeks after operation on a 15-point scale.
CONCLUSIONS
Controlled standardized dry eye treatment (with HC) improved tear film stability, ocular surface defects, and subjective symptoms of dry eye disease in patients 5 weeks after undergoing cataract surgery. Both the patient and physician assessments indicated high efficacy, tolerability, and a reliable safety profile, as indicated by the low number of at least possibly related adverse events (AE), suggesting its beneficial role in the postoperative management of the ocular surface (OS) in patients with dry eye symptoms prior to and after cataract surgery.
PubMed: 38893624
DOI: 10.3390/diagnostics14111097 -
Cancers May 2024Helium ion therapy (HRT) is a promising modality for the treatment of pediatric tumors and those located close to critical structures due to the favorable biophysical...
Helium ion therapy (HRT) is a promising modality for the treatment of pediatric tumors and those located close to critical structures due to the favorable biophysical properties of helium ions. This in silico study aimed to explore the potential benefits of HRT in advanced juvenile nasopharyngeal angiofibroma (JNA) compared to proton therapy (PRT). We assessed 11 consecutive patients previously treated with PRT for JNA in a definitive or postoperative setting with a relative biological effectiveness (RBE) weighted dose of 45 Gy (RBE) in 25 fractions at the Heidelberg Ion-Beam Therapy Center. HRT plans were designed retrospectively for dosimetric comparisons and risk assessments of radiation-induced complications. HRT led to enhanced target coverage in all patients, along with sparing of critical organs at risk, including a reduction in the brain integral dose by approximately 27%. In terms of estimated risks of radiation-induced complications, HRT led to a reduction in ocular toxicity, cataract development, xerostomia, tinnitus, alopecia and delayed recall. Similarly, HRT led to reduced estimated risks of radiation-induced secondary neoplasms, with a mean excess absolute risk reduction of approximately 30% for secondary CNS malignancies. HRT is a promising modality for advanced JNA, with the potential for enhanced sparing of healthy tissue and thus reduced radiation-induced acute and long-term complications.
PubMed: 38893114
DOI: 10.3390/cancers16111993 -
Journal of Clinical Medicine Jun 2024: The Carlevale lens (FIL SSF, Soleko IOL Division, Italy) is a new lens for suture-less scleral fixation. This paper aimed to systematically review articles on this... (Review)
Review
: The Carlevale lens (FIL SSF, Soleko IOL Division, Italy) is a new lens for suture-less scleral fixation. This paper aimed to systematically review articles on this lens, the surgical techniques used for its implantation, complications and outcomes. : This systematic review was performed following the PRISMA guidelines. The search string used was "Carlevale" AND "scleral fixation" from inception until March 2024. For completeness, either case-control studies, case reports or case series written in English were included. The authors used the Newcastle-Ottawa scale for the case-control studies and the JBI Critical Appraisal Checklist for case reports and case series. : Twenty-nine articles were included. Scleral fixation with Carlevale lens can be performed by creating scleral flaps or, alternatively, by using scleral pockets. The two sclerotomies must be diametrically opposed, and are preferably created by 25-gauge trocars. A pars plana vitrectomy should be performed every time, and the design of the lens should be suitable for self-anchoring to the sclera; the most accredited strategy to achieve this is to avoid scleral sutures. There were only a few intraoperative and postoperative complications reported; vitreous hemorrhages were the most frequent intraoperative events, while the most relevant postoperative complications were vitreous hemorrhages, cystoid macular oedema and transient variations in the intraocular pressure. Excellent results have been obtained in terms of BCVA, IOL centration and stability, mean intraocular pressure, postoperative spherical equivalent, separation between anterior and posterior chamber and the distance of the IOL from anterior chamber structures. : The foldable hydrophilic design of the Carlevale lens has shown good effectiveness, IOL stability and few intra and post-operative complications.
PubMed: 38892997
DOI: 10.3390/jcm13113287 -
Journal of Clinical Medicine May 2024Ophthalmic three-dimensional (3D) digital surgery can reproduce high-definition surgical images; however, 3D digital surgery is limited by recording capacities. We...
Ophthalmic three-dimensional (3D) digital surgery can reproduce high-definition surgical images; however, 3D digital surgery is limited by recording capacities. We examined the relationship between the minimum image quality required to reproduce surgical images and recording capacity. Patients who underwent simultaneous vitrectomy and cataract surgery by the same surgeon using a 3D digital surgery system at Juntendo University Urayasu Hospital between February and October 2021 were evaluated. Various quality (Q) and frame rate (FR) settings were used for each case. Four vitreous surgeons evaluated the reproducibility of recorded images of macular manipulation for epiretinal membrane (ERM) and macular hole (MH) cases and those of peripheral retinal manipulation for rhegmatogenous retinal detachment (RRD) cases. The video bitrate and minimum settings required to reproduce surgical images and factors affecting surgical image reproducibility were examined. A total of 129 eyes of 129 patients were observed. The minimum image quality required to reproduce surgical images was 11.67 Mbps. The Q and FR for periretinal processing and Q for macular manipulation affected surgical image reproducibility ( = 0.025, = 0.019, and = 0.07, respectively). The minimum recording settings required to obtain highly reproducible images were Q = 3 and FR = 40. The total file size for vitrectomy video recordings with these settings was as compact as 3.17 GB for 28 min. During 3D digital surgery, highly reproducible surgical images can be obtained with a small storage capacity using settings of at least Q = 3 and FR = 40.
PubMed: 38892762
DOI: 10.3390/jcm13113051 -
International Journal of Molecular... Jun 2024The microbiome of the ocular surface has been characterised, but only limited information is available on a possible silent intraocular microbial colonisation in normal...
The microbiome of the ocular surface has been characterised, but only limited information is available on a possible silent intraocular microbial colonisation in normal eyes. Therefore, we performed next-generation sequencing (NGS) of 16S rDNA genes in the aqueous humour. The aqueous humour was sampled from three patients during cataract surgery. Air swabs, conjunctival swabs from patients as well as from healthy donors served as controls. Following DNA extraction, the V3 and V4 hypervariable regions of the 16S rDNA gene were amplified and sequenced followed by denoising. The resulting Amplicon Sequence Variants were matched to a subset of the Ribosomal Database Project 16S database. The deduced bacterial community was then statistically analysed. The DNA content in all samples was low (0-1.49 ng/µL) but sufficient for analysis. The main phyla in the samples were (48%), (26%), (14%), (8%), and (2%). Patients' conjunctival control samples and anterior chamber fluid showed similar patterns of bacterial species containing many waterborne species. Non-disinfected samples showed a different bacterial spectrum than the air swab samples. The data confirm the existence of an ocular surface microbiome. Meanwhile, a distinct intraocular microbiome was not discernible from the background, suggesting the absence of an intraocular microbiome in normal eyes.
Topics: Humans; Aqueous Humor; Microbiota; High-Throughput Nucleotide Sequencing; RNA, Ribosomal, 16S; Bacteria; DNA, Bacterial; Male; Female; Aged; Middle Aged; Sequence Analysis, DNA
PubMed: 38892316
DOI: 10.3390/ijms25116128 -
International Journal of Molecular... May 2024Retinitis pigmentosa (RP) is an inherited retinal dystrophy caused by the loss of photoreceptors and retinal pigment epithelial atrophy, leading to severe visual...
Retinitis pigmentosa (RP) is an inherited retinal dystrophy caused by the loss of photoreceptors and retinal pigment epithelial atrophy, leading to severe visual impairment or blindness. RP can be classified as nonsyndromic or syndromic with complex clinical phenotypes. Three unrelated Polish probands affected with retinitis pigmentosa coexisting with cerebellar ataxia were recruited for this study. Clinical heterogeneity and delayed appearance of typical disease symptoms significantly prolonged the patients' diagnostic process. Therefore, many clinical and genetic tests have been performed in the past. Here, we provide detailed clinical and genetic analysis results of the patients. Whole-exome sequencing (WES) and targeted NGS analysis allow the identification of four novel and two previously reported variants in the following genes: , , and The use of next-generation sequencing (NGS) methods finally allowed for confirmation of the clinical diagnosis. Ultra-rare diseases such as PHARC, PCARP, and Oliver-McFarlane syndromes were diagnosed in patients, respectively. Our findings confirmed the importance of the application of next-generation sequencing methods, especially in ultra-rare genetic disorders with overlapping features.
Topics: Humans; Retinitis Pigmentosa; Male; Female; Exome Sequencing; Pedigree; High-Throughput Nucleotide Sequencing; Adult; Cerebellar Ataxia; Membrane Transport Proteins; Monoacylglycerol Lipases; Mutation; Ataxia; Phenotype; Acyltransferases; Cataract; Phospholipases; Polyneuropathies
PubMed: 38891946
DOI: 10.3390/ijms25115759 -
Ceska a Slovenska Oftalmologie :... 2024The aim of the thesis is to present the case of a patient in whom bilateral calcification of the hydrophilic intraocular lens (IOL) Lentis M+ LS-313 MF30 (Oculentis)...
The aim of the thesis is to present the case of a patient in whom bilateral calcification of the hydrophilic intraocular lens (IOL) Lentis M+ LS-313 MF30 (Oculentis) has developed. Due to the negative effect on visual functions, explantation and replacement of the artificial lens was necessary in both eyes. Case Report: An overview of the available literature summarized the diagnostics, current examination methods and possibilities of the surgical solution of calcification of the bifocal hydrophilic lens Lentis M+ LS-313 MF30 (Oculentis). The specific solution is described in a case report of a patient in whom calcification of both lenses developed 6 years after implantation of the IOL. In 2015, the patient underwent uncomplicated cataract surgery of both eyes with the implantation of an artificial intraocular lens into the capsule. In September 2021, an 82-year-old man was examined at our outpatient clinic for deterioration of visual acuity and changes in the material of the artificial IOL which were perceptible during a clinical examination, on the recommendation of a local ophthalmologist. Blurred vision predominated. A diagnosis of intraocular lens opacification was confirmed and documented using a Scheimpflug camera (OCULUS Pentacam HR) and anterior OCT (Avanti RTVue XR Optovue,). The patient was indicated for explantation and replacement of the opacified intraocular lens in the left and subsequently in the right eye- The same type of IOL was used for reimplantation with good functional results. Conclusion: Since 2010, multifocal lens implantation has been on an upward trend worldwide. This type of MF IOL has also been used in thousands of implantations. A number of other explantations can be expected in the coming years. The optimal solution is the correct replacement of the calcified IOL with the same construction made of safer hydrophobic material.
Topics: Humans; Male; Radiosurgery; Melanoma; Aged, 80 and over; Calcinosis; Choroid Neoplasms; Lenses, Intraocular; Radiation Injuries; Uveal Neoplasms; Lens Implantation, Intraocular
PubMed: 38886109
DOI: 10.31348/2024/22 -
Cureus May 2024Alstrom syndrome is an autosomal recessive disease. It affects multiple systems, including cardiovascular, renal, endocrine, and eyes. Our patient is a 25-year-old...
Alstrom syndrome is an autosomal recessive disease. It affects multiple systems, including cardiovascular, renal, endocrine, and eyes. Our patient is a 25-year-old female who presented with elevated creatinine. Her past medical history was significant for hypothyroidism, polycystic ovarian syndrome, blindness, cataracts, hearing loss, and heart problems. She had genetic testing done that revealed that she was homozygous for the ALMS1 gene and was diagnosed with Alstrom syndrome. She was followed by nephrology in the clinic and had chronic kidney disease (CKD) stage V. The patient traveled to Italy and was lost to follow-up.
PubMed: 38883129
DOI: 10.7759/cureus.60334 -
Cureus May 2024Background Cataract is a condition that affects the lens, causing separation and/or aggregation of proteins and disrupting the regular alignment of cell fibers....
Background Cataract is a condition that affects the lens, causing separation and/or aggregation of proteins and disrupting the regular alignment of cell fibers. Cataracts have many known risk factors contributing to their development, such as diabetes, oral steroid therapy, smoking, and high body mass index. Good knowledge about cataracts may improve the quality of treatment through early diagnosis. Unfortunately, poor knowledge is still a significant barrier to reducing blindness caused by cataracts in developing countries. Methodology This cross-sectional study was conducted using a pre-validated questionnaire and online questionnaires. Participants were approached through multiple social media platforms from June 2022 to August 2022. Results Of the 307 participants, with a mean age of 32.4 ± 12.8 years, 51.5% had good knowledge of cataracts and their related risk factors, while 28.7% had a favorable attitude about cataracts. Of all participants, 50.5% reported a diagnosis of cataract. The majority of participants, 58.6%, who did not have cataracts, had good knowledge versus 44.5% of others with (p = 0.014). Moreover, 75% of participants aged 50 years or older had good overall cataract knowledge levels compared to 38.9% of others aged 30-39 years (p = 0.002). Conclusions Cataracts are a preventable cause of blindness that can be corrected by surgery. In this study, we discovered extremely concerning rates of knowledge, awareness, and attitudes regarding cataracts among the populations of Hail City. More educational programs should be directed toward spreading knowledge about cataracts to patients and the public.
PubMed: 38882987
DOI: 10.7759/cureus.60444 -
Heliyon Jun 2024Shear wave elastography (SWE) is a novel imaging technique that provides quantitative assessments of tissue stiffness. This non-invasive method offers real-time,...
BACKGROUND
Shear wave elastography (SWE) is a novel imaging technique that provides quantitative assessments of tissue stiffness. This non-invasive method offers real-time, quantitative measurements and has been widely applied to various tissues, providing valuable diagnostic insights.
PURPOSE
This study aimed to investigate the feasibility of using SWE to evaluate the stiffness of the lens in patients with age-related cataracts.
MATERIALS AND METHODS
A comparative analysis involving 92 patients diagnosed with age-related cataracts and 39 healthy controls was conducted. Lens stiffness was quantified using SWE measurements. The lens nucleus of all participants was graded based on the Lens Opacities Classification System II (LOCS II). Correlations between the stiffness of the lens and age were also analyzed.
RESULTS
The study indicates that both the stiffness of the lens and the lens nucleus were significantly higher in patients with age-related cataracts compared to healthy controls ( < 0.001). In patients with age-related cataracts, although lens nucleus stiffness variations across different grades of cataract severity were not statistically significant, all grades displayed increased stiffness relative to healthy controls. Additionally, a significant positive correlation between lens stiffness and age was observed in all participants ( < 0.001).
CONCLUSION
SWE appears to be a promising imaging technique for quantitatively assessing the mechanical characteristics of the lens in patients with age-related cataracts.
PubMed: 38882265
DOI: 10.1016/j.heliyon.2024.e32255