BMC Ophthalmology Apr 2024Postoperative performance, including best corrected distance visual acuity (BCDVA) and optical metrics (from the OQAS and iTrace devices), was compared among 4 different... (Observational Study)
Observational Study Comparative Study
BACKGROUND
Postoperative performance, including best corrected distance visual acuity (BCDVA) and optical metrics (from the OQAS and iTrace devices), was compared among 4 different intraocular lenses (IOLs).
METHODS
This prospective observational study included 104 eyes from 104 subjects who underwent cataract surgery combined with implantation of 4 different IOLs: monofocal (Mon) IOLs, segmental refractive (SegRef) IOLs, diffractive (Dif) IOLs and extended depth of focus (EDoF) IOLs. Postoperative BCDVA and optical metrics were collected at the 6th month. The OQAS optical metrics included the objective scattering index (OSI), Strehl ratio (SR), modulation transfer function (MTF) cut-off frequency, and predicted visual acuity (PVA); the iTrace optical metrics included blur/double vision, glare/halo, starburst, mixed focus, night myopia, and night hyperopia.
RESULTS
There was no significant difference in BCDVA among the 4 groups (P = 0.059; power = 70.3%). Differences were observed in all OQAS optical metrics among the groups (all P < 0.001). Overall, Mon IOLs and EDoF IOLs exhibited better performance than Dif IOLs and SegRef IOLs. Starburst was the only iTrace optical metric that differed among the groups (P < 0.001): SegRef IOLs caused more starbursts than Mon IOLs (P = 0.001), Dif IOLs (P = 0.006) and EDoF IOLs (P < 0.001). Spearman rank correlation analysis was used to determine the relationships among the iTrace optical metrics, OQAS optical metrics and BCDVA: starburst was negatively correlated with BCDVA, PVA at contrasts of 100% and 20%, OSI, and MTF cut-off frequency (all P ≤ 0.001); mixed focus was positively correlated with BCDVA, PVA at contrasts of 100% and 20%, OSI, and MTF cut-off frequency (all P ≤ 0.001).
CONCLUSIONS
Postoperative BCDVA and optical metrics varied among the different IOLs, which should be taken into account in the selection and management of IOLs for cataract patients.
TRIAL REGISTRATION
This study was approved by the First Affiliated Hospital of Guangzhou Medical University Ethical Review Board (No. 50 2022).
Topics: Humans; Prospective Studies; Visual Acuity; Female; Lenses, Intraocular; Male; Aged; Middle Aged; Phacoemulsification; Refraction, Ocular; Lens Implantation, Intraocular; Prosthesis Design; Postoperative Period; Pseudophakia; Optics and Photonics
PubMed: 38671381
DOI: 10.1186/s12886-024-03439-0 -
BMC Ophthalmology Apr 2024To evaluate short-term visual and refractive outcomes after implantation of a diffractive trifocal intraocular lens (IOL) in cataract patients with phacoemulsification... (Observational Study)
Observational Study Comparative Study
PURPOSE
To evaluate short-term visual and refractive outcomes after implantation of a diffractive trifocal intraocular lens (IOL) in cataract patients with phacoemulsification (PHACO) and femtosecond laser assisted cataract surgery (FLACS).
SETTING
Department of Ophthalmology, Shanghai Aier Eye Hospital, China.
DESIGN
A retrospective, observational study.
METHODS
Patients who underwent cataract surgery combined with Acrysoft IQ PanOptix trifocal IOL implantation were enrolled and divided into three groups: PHACO group, LAstig-FLACS group (astigmatism less then 1D) and HAstig-FLACS group (astigmatism more than 1D). Logarithm of the minimum angle of resolution (logMAR) visual acuity of uncorrected distance (UDVA), intermediate (UIVA), near visual (UNVA), defocus curve, surgically induced astigmatism (SIA) were evaluated in 1 months postoperatively and wavefront aberrations were evaluated in 6 months.
RESULTS
101 eyes of 60 patients were included with 31 eyes in PHACO group, 45 eyes in LAstig-FLACS group and 25 eyes in HAstig-FLACS group. Significant difference was found of internal Strehl Ratio (SR) between PHACO and LAstig-FLACS group (P = 0.026). In PHACO group, 79.31%, 86.21%, 72.41% of eyes gain visual acuity LogMAR 0.1 or more in UDVA, UIVA and UNVA, while 83.72%, 93.02%, 93.02% of those in LAstig-FLACS group and 92.00%, 84.00%, 76.00% in HAstig-FLACS group.
CONCLUSIONS
Panoptix diffractive trifocal IOL provides satisfied visual outcome in no matter FLACS or PHACO. Besides, trifocal IOL implantation via FLACS can provide a better accumulative visual acuity outcome at all distance than PHACO in 1 month. Femtosecond laser assisted limbal relaxing incisions (FLLRIs) is an excellent way to reduce a patient's corneal astigmatism.
Topics: Humans; Retrospective Studies; Male; Female; Phacoemulsification; Visual Acuity; Middle Aged; Laser Therapy; Aged; Multifocal Intraocular Lenses; Refraction, Ocular; Lens Implantation, Intraocular; Pseudophakia; Treatment Outcome; Prosthesis Design; Cataract Extraction; Follow-Up Studies
PubMed: 38658894
DOI: 10.1186/s12886-024-03440-7 -
Journal of Cataract and Refractive... May 2024To compare flange depth for a modified scleral pocket (SP) vs no scleral pocket (NSP) technique (Yamane technique) for intrascleral intraocular lens (IOL) fixation. (Randomized Controlled Trial)
Randomized Controlled Trial Observational Study Comparative Study
PURPOSE
To compare flange depth for a modified scleral pocket (SP) vs no scleral pocket (NSP) technique (Yamane technique) for intrascleral intraocular lens (IOL) fixation.
SETTING
Instituto de Oftalmología Santa Fe, Santa Fe, Argentina.
DESIGN
Prospective, randomized, single-surgeon, observational study.
METHODS
Eyes with aphakia and no capsular support were included. They were divided into 2 groups: one was programmed for a double-needle flanged intrascleral IOL fixation as originally described by Shin Yamane with NSP and the second group had a modified SP technique. Flange depth was measured with anterior-segment optical coherence tomography (AS-OCT) at 1 month, 3 months, 6 months, and 12 months postoperatively, and the results were compared.
RESULTS
Each group comprised 18 eyes of 18 patients, giving a total of 36 flanges per group. The groups were comparable preoperatively. At 12 months, uncorrected distance visual acuity and corrected distance visual acuity (CDVA) were not statistically different for both groups (P = .333; P = .448). Spherical equivalent (SEQ) was not significantly different between groups at 12 months postoperatively (P = .078). AS-OCT revealed a significantly deeper flange position for the SP group at 1 month, 3 months, 6 months, and 12 months postoperatively (P < .05).
CONCLUSIONS
When performing a double-needle intrascleral IOL fixation in aphakic eyes with no capsular support, a modified scleral pocket technique provides a significantly deeper flange position with no difference in CDVA or SEQ 12 months postoperatively.
Topics: Humans; Sclera; Lens Implantation, Intraocular; Prospective Studies; Visual Acuity; Tomography, Optical Coherence; Lenses, Intraocular; Female; Male; Middle Aged; Aged; Aphakia, Postcataract; Surgical Flaps; Suture Techniques; Pseudophakia; Refraction, Ocular
PubMed: 38651698
DOI: 10.1097/j.jcrs.0000000000001383 -
BMC Ophthalmology Apr 2024To evaluate the objective visual outcomes following implantation of extended depth of focus intraocular lens (EDOF IOL) in individuals with varying axial lengths (AL)...
AIM
To evaluate the objective visual outcomes following implantation of extended depth of focus intraocular lens (EDOF IOL) in individuals with varying axial lengths (AL) and targeted refraction.
METHODS
This retrospective study comprised age-matched eyes that underwent implantation of the EDOF IOL. Eyes were categorized based on AL into groups: control group with AL < 26 mm; high myopia group with AL ≥ 26 mm. Each group was then subdivided based on postoperative spherical equivalent (SE). Follow-up at three months included assessment of uncorrected visual acuity at different distances, contrast sensitivity (CS), refractive outcomes, and spectacle independence.
RESULTS
Overall, this study included 100 eyes from 100 patients, comprising 50 males (50.00%) and 50 females (50.00%), with 20 eyes in each group. In the control group, the uncorrected distance visual acuity (UDVA) at 5 and 3 m (m) in the - 1.50 to -0.75 group was inferior to that of the - 0.75 to 0.00 group (P = 0.004). Conversely, the uncorrected near visual acuity (UNVA) at 33 cm in the - 1.50 to -0.75 group was superior to that of the - 0.75 to 0.00 group (P = 0.005). Within the high myopia group, the UDVA at 5 and 3 m in the - 2.25 to -1.50 group was worse than in the - 0.75 to 0.00 group (P = 0.009 and 0.008, respectively). However, the UNVA at 33 cm in the - 2.25 to -1.50 group was better than in the - 0.75 to 0.00 group (P = 0.020). No significant differences were observed among the groups for corrected distance visual acuity (CDVA) (P > 0.05). Additionally, in the high myopia group, the CS of the - 2.25 to -1.50 group was lower compared to that of the - 0.75 to 0.00 group (P = 0.017). Among high myopia patients, 90.00% with refraction ranging from - 1.50 to -0.75 reported achieving overall spectacle independence.
CONCLUSIONS
Implantation of extended depth of focus intraocular lenses (IOLs) yields satisfactory visual and refractive outcomes in eyes with axial myopia. Among high myopia patients, a refraction ranging from - 1.50 to -0.75 diopters achieves superior visual quality compared to other postoperative myopic diopters.
Topics: Humans; Female; Male; Retrospective Studies; Visual Acuity; Refraction, Ocular; Middle Aged; Myopia; Lenses, Intraocular; Lens Implantation, Intraocular; Aged; Prosthesis Design; Adult; Contrast Sensitivity; Phacoemulsification; Pseudophakia; Axial Length, Eye; Depth Perception; Follow-Up Studies
PubMed: 38649861
DOI: 10.1186/s12886-024-03442-5 -
Ophthalmology. Glaucoma Apr 2024Compare outcomes of tube shunt surgery (Tube) and trabeculectomy with mitomycin C (Trab-MMC) in patients with angle-closure glaucoma (ACG).
PURPOSE
Compare outcomes of tube shunt surgery (Tube) and trabeculectomy with mitomycin C (Trab-MMC) in patients with angle-closure glaucoma (ACG).
DESIGN
Retrospective nonrandomized comparative study.
PARTICIPANTS
A total of 80 eyes from 80 patients with ACG who underwent either Tube (N = 50) or Trab-MMC (N = 30) between January 2015 and January 2022 at Massachusetts Eye and Ear.
METHODS
Reviewed and analyzed 390 visits from patient charts.
MAIN OUTCOME MEASURES
Kaplan-Meier (KM) success rates, intraocular pressure (IOP), medication burden, best-corrected visual acuity (BCVA), adjusted hazard ratios (HRs), and complications.
RESULTS
Baseline demographics were similar between both groups, except for a higher proportion of patients with pseudophakia and prior incisional ocular surgery in the Tube group. The Trab-MMC procedure had significantly higher KM complete success (CS) rates than the Tube procedure, but similar qualified success (QS) rates. Under QS, the cumulative probability of survival was 87% in the Tube group and 83% in the Trab-MMC group at year 1 (P = 0.77), and 75% in the Tube group and 58% in the Trab-MMC group at year 2 (P = 0.14). Under CS, the cumulative probability of survival was 13% in the Tube group and 59% in the Trab-MMC group at year 1 (P < 0.001), and 11% in the Tube group and 41% in the Trab-MMC group at year 2 (P < 0.001). Both Tube and Trab-MMC procedures resulted in significant patterns of IOP and medication reduction from baseline up to 2 years with mean IOP reduced to 12.6 ± 5.9 mmHg on 2.8 ± 1.4 medications after Tube and 12.1 ± 6.6 mmHg on 2.4 ± 1.7 medications after Trab-MMC. Patients who underwent Trab-MMC required less IOP-lowering medications at every follow-up visit up to year 1, but a similar number at year 2. No significant differences were found in IOP reduction, BCVA, or complication rates between groups.
CONCLUSIONS
We demonstrate that Trab-MMC confers similar IOP reduction and QS rates to Tube placement in patients with ACG. Trab-MMC, however, demonstrated greater medication burden reduction up to 1 year, and more favorable CS rates up to 2 years, while still maintaining similar complication rates to Tube.
FINANCIAL DISCLOSURE(S)
The author(s) have no proprietary or commercial interest in any materials discussed in this article.
PubMed: 38636705
DOI: 10.1016/j.ogla.2024.04.005 -
Eye (London, England) May 2024To evaluate the tolerance to refractive errors of a new purely refractive extended depth of focus (EDF) intraocular lens (IOL) using preclinical and clinical metrics. (Randomized Controlled Trial)
Randomized Controlled Trial
PURPOSE
To evaluate the tolerance to refractive errors of a new purely refractive extended depth of focus (EDF) intraocular lens (IOL) using preclinical and clinical metrics.
METHODS
Preclinical evaluation included computer simulations of visual acuity (sVA) and dysphotopsia profile of different IOL designs (refractive EDF, diffractive EDF, multifocal, standard, and enhanced monofocals) using an appropriate eye model with and without ±0.50 D defocus and/or +0.75 D of astigmatism. Patients bilaterally implanted with a refractive EDF (Model ZEN00V) or an enhanced monofocal (Model ICB00) IOL from a prospective, randomized study were included. At the 6-month postoperative visit, uncorrected and corrected distance vision (UDVA and CDVA), visual symptoms, satisfaction and dependency on glasses were evaluated in a subgroup of patients with absolute residual refractive error of >0.25 D in one or both eyes.
RESULTS
In the presence of defocus and astigmatism, sVA was comparable for all except the multifocal IOL design. The refractive EDF was more tolerant to myopic outcomes and maintained a monofocal-like dysphotopsia profile with defocus. Binocular logMAR UDVA was -0.03 ± 0.08 for ZEN00V and -0.02 ± 0.11 for ICB00. 100% ZEN00V and 97% ICB00 patients did not need glasses and were satisfied with their distance vision. Monocular CDVA, contrast sensitivity and visual symptoms were also similar between both groups.
CONCLUSIONS
The clinical outcomes of the refractive EDF IOL demonstrated high quality distance vision and dysphotopsia comparable to a monofocal IOL, even in the presence of refractive error, thus matching the design expectations of the EDF IOL.
Topics: Humans; Visual Acuity; Lenses, Intraocular; Prospective Studies; Lens Implantation, Intraocular; Female; Prosthesis Design; Male; Middle Aged; Aged; Depth Perception; Pseudophakia; Refractive Errors; Phacoemulsification; Patient Satisfaction; Computer Simulation; Refraction, Ocular; Astigmatism; Vision, Binocular
PubMed: 38580742
DOI: 10.1038/s41433-024-03040-1 -
Eye (London, England) May 2024To evaluate the visual performance of a purely refractive extended depth of focus (EDF) intraocular lens (IOL). (Randomized Controlled Trial)
Randomized Controlled Trial
BACKGROUND/OBJECTIVE
To evaluate the visual performance of a purely refractive extended depth of focus (EDF) intraocular lens (IOL).
SUBJECTS/METHODS
A prospective, multi-center, randomized, subject/evaluator-masked study. Subjects were bilaterally implanted with the EDF test (Model ZEN00V, N = 60) or an enhanced monofocal control (Model ICB00, N = 57) IOL. Monocular corrected distance (CDVA), intermediate (DCIVA), near acuities (DCNVA) and patient reported visual symptoms were evaluated at the 6-month visit. Monocular mesopic contrast sensitivity (CS) and depth of focus (DOF) testing were assessed at 3 months.
RESULTS
CDVA (Mean ± SD) was -0.06 ± 0.08 for test and -0.05 ± 0.08 logMAR for control groups. DCIVA was 0.13 ± 0.08 for test and 0.18 ± 0.14 logMAR for control groups (p = 0.0127). DCNVA was 0.37 ± 0.10 for test and 0.43 ± 0.16 logMAR for control groups (p = 0.0137). Test lens was statistically superior for intermediate and near. Overall, 91.7% (halos), 95.0% (starbursts) and 95.0% (glare) of test lens patients reported that they did not experience, were not bothered, or were slightly bothered by specific visual symptoms, compared to 98.2%, 100% and 96.5% in the control group. The DOF range over which monocular visual acuity was 0.20 logMAR or better was -1.6 D for the test lens. Mesopic CS was comparable between both groups, falling within 0.11 log units for all measured cycles per degree with and without glare.
CONCLUSION
The EDF IOL demonstrated extended range of vision and statistically superior intermediate and near performance compared to the monofocal IOL. Distance visual acuity, contrast sensitivity and dysphotopsia profile were similar to the monofocal IOL.
Topics: Humans; Prospective Studies; Visual Acuity; Female; Male; Contrast Sensitivity; Lenses, Intraocular; Aged; Middle Aged; Depth Perception; Lens Implantation, Intraocular; Pseudophakia; Prosthesis Design; Refraction, Ocular; Phacoemulsification; Double-Blind Method; Patient Satisfaction
PubMed: 38580741
DOI: 10.1038/s41433-024-03039-8 -
BMC Ophthalmology Mar 2024To determine the distribution of subfoveal choroidal thickness (SFCT) and its associated demographic, ocular, and systemic factors in an elderly population.
PURPOSE
To determine the distribution of subfoveal choroidal thickness (SFCT) and its associated demographic, ocular, and systemic factors in an elderly population.
METHODS
This report is part of the Tehran Geriatric Eye Study (TGES); a population-based cross-sectional study that was conducted on the urban elderly population of Tehran, aged 60 years and above using multi-stage stratified random cluster sampling. Choroidal imaging was performed using Spectralis SD-OCT with enhanced depth imaging mode.
RESULTS
The average SFCT was 265.3 ± 25.9 μm (95% CI: 262.8-267.7) in the whole sample. According to the multiple generalized estimating equation (GEE) model, pseudophakia had a statistically significant direct relationship with SFCT (coefficient = 5.69), and history of cerebrovascular accident (CVA) was significantly inversely related to SFCT (coefficient=-4.77). Moreover, there was a significant interaction between age and sex in the average SFCT so that with increasing age, the SFCT increased in men and decreased in women.
CONCLUSION
The normal values of SFCT in the present study can be used as a reference database for clinical and research purposes. Age-sex interaction, pseudophakia, and history of CVA were significantly associated with SFCT in the elderly population. It is recommended that these factors be taken into account when interpreting SFCT data.
Topics: Male; Humans; Aged; Female; Cross-Sectional Studies; Pseudophakia; Iran; Choroid; Tomography, Optical Coherence
PubMed: 38532398
DOI: 10.1186/s12886-024-03401-0 -
Oman Journal of Ophthalmology 2024A 48-year-old male with oculocutaneous albinism (OCA) presented with bilateral diminution of vision. Ocular examination revealed bilateral central corneal thinning,...
A 48-year-old male with oculocutaneous albinism (OCA) presented with bilateral diminution of vision. Ocular examination revealed bilateral central corneal thinning, scarring with ectasia, depigmented irides, transillumination defects, and pseudophakia. Examination of the right eye also revealed a hyperoleon, emulsified silicon oil in the vitreous cavity, and an attached retina, while the left eye had a total rhegmatogenous retinal detachment (RRD). This case describes a unique set of challenges (the presence of an ectatic scarred cornea and a hypopigmented fundus) and sodium fluorescein dye as an adjunct in the surgical management of a complex RRD. A review of literature highlighting the association of keratoconus and RRD in OCA is also presented in this report.
PubMed: 38524338
DOI: 10.4103/ojo.ojo_35_23 -
American Journal of Ophthalmology Mar 2024To update the literature on peripheral optics and vision following intraocular lens (IOLs) implantation. (Review)
Review
PURPOSE
To update the literature on peripheral optics and vision following intraocular lens (IOLs) implantation.
METHODS
We investigated how current IOLs influence peripheral visual function, peripheral optical quality, and visual perception and performance, in patients following cataract surgery. Peripheral vision is described as vision outside the central foveal region of the eye (beyond 4-5° of eccentricity). We systematically searched PubMed, Cochrane Central Register of Controlled Trials, Embase, and gray literature for relevant references. Randomized controlled trials and observational studies were eligible for inclusion. Finally, 47 studies with a total of 5963 participants were eligible for this review, of which 15 were included in the meta-analysis.
RESULTS
Regarding visual fields, the meta-analysis showed that the pooled estimate of mean deviation (MD) measured with perimetry tests (standard automated perimetry [SAP], short-wavelength automated perimetry [SWAP], and frequency doubling technology [FDT]) appears to be lower than the mean of healthy age-matched controls, regardless of IOL design. Results for pooled estimate show that localized defects (pattern standard deviation [PSD]) were higher than those in the healthy age-matched controls for FDT. We also collected evidence demonstrating that pseudophakia increases peripheral astigmatism and a myopic shift from 20° onward, leading to decreased peripheral image quality compared with that in phakic eyes. Patient-reported outcomes on peripheral vision showed a pooled score estimate of 95.19, indicating high satisfaction, and for the Steps & Stairs questions, a pooled score estimate at 0.23, indicating no to little difficulty seeing steps and stairs.
CONCLUSIONS
Peripheral image quality is degraded in eyes after cataract surgery. Nevertheless, whether this degradation leads to impaired visual function in the periphery requires further investigation.
PubMed: 38521156
DOI: 10.1016/j.ajo.2024.03.016