-
Brazilian Journal of Medical and... 2023Scoliosis is a condition that affects the spine and causes chest rotation and trunk distortion. Individuals with severe deformities may experience dyspnea on exertion...
Scoliosis is a condition that affects the spine and causes chest rotation and trunk distortion. Individuals with severe deformities may experience dyspnea on exertion and develop respiratory failure. Respiratory oscillometry is a simple and non-invasive method that provides detailed information on lung mechanics. This work aims to investigate the potential of oscillometry in the evaluation of respiratory mechanics in patients with scoliosis and its association with physical performance. We analyzed 32 volunteers in the control group and 32 in the scoliosis group. The volunteers underwent traditional pulmonary function tests, oscillometry, and the 6-minute walk test (6MWT). Oscillometric analysis showed increased values of resistance at 4 Hz (R4, P<0.01), 12 Hz (R12, P<0.0001), and 20 Hz (R20, P<0.01). Similar analysis showed reductions in dynamic compliance (Cdyn, P<0.001) and ventilation homogeneity, as evaluated by resonance frequency (fr, P<0.001) and reactance area (Ax, P<0.001). Respiratory work, described by the impedance modulus, also showed increased values (Z4, P<0.01). Functional capacity was reduced in the group with scoliosis (P<0.001). A significant direct correlation was found between Cobb angle and R12, AX, and Z4 (P=0.0237, P=0.0338, and P=0.0147, respectively), and an inverse correlation was found between Cdyn and Cobb angle (P=0.0190). These results provided new information on respiratory mechanics in scoliosis and are consistent with the involved pathophysiology, suggesting that oscillometry may improve lung function tests for patients with scoliosis.
Topics: Humans; Scoliosis; Oscillometry; Lung; Respiratory Function Tests; Respiratory Mechanics
PubMed: 37937601
DOI: 10.1590/1414-431X2023e12898 -
ERJ Open Research Sep 2023Impulse oscillometry (IOS) is sensitive in detecting lung function impairment. In small studies, impaired IOS relates better to respiratory symptoms than spirometry. We...
BACKGROUND
Impulse oscillometry (IOS) is sensitive in detecting lung function impairment. In small studies, impaired IOS relates better to respiratory symptoms than spirometry. We studied how IOS related to spirometry and respiratory symptoms in a large population of individuals (n=10 360) in a cross-sectional analysis.
METHODS
Normal values for IOS and spirometry were defined in healthy, never-smoking individuals, aged 50-64 years, from the Swedish CArdioPulmonary bioImage Study (n=3664 for IOS and 3608 for spirometry). For IOS, abnormal values for resistance at 5 Hz () and at 20 Hz and area of reactance were defined using the 95th percentile. Abnormal reactance at 5 Hz for IOS and abnormal conventional spirometry indices (forced expiratory volume in 1 s (FEV), forced and slow vital capacity and their ratios) were defined using the 5th percentile.
RESULTS
Abnormal IOS parameters were found in 16% of individuals and were associated with increased odds ratios for nearly all respiratory symptoms when adjusted for age, gender and smoking. In individuals with normal spirometry, abnormal IOS resistance was related to cough and dyspnoea, while abnormal reactance was related to wheeze. In these individuals, the combination of abnormal with abnormal reactance resulted in approximately two-fold higher likelihood for having cough, chronic bronchitis and dyspnoea, even when further adjusting for FEV, expressed as % predicted.
CONCLUSIONS
Abnormal IOS is related to increased respiratory burden in middle-aged individuals with normal spirometry, especially when resistance and reactance parameters are combined. The different relationships between respiratory symptoms and reactance and resistance warrant further research.
PubMed: 37753278
DOI: 10.1183/23120541.00736-2022 -
Respiratory Medicine and Research Nov 2023The forced oscillation technique (FOT) may be useful for diagnosis and follow-up of respiratory diseases. It is unclear how global or regional alterations in airway...
BACKGROUND
The forced oscillation technique (FOT) may be useful for diagnosis and follow-up of respiratory diseases. It is unclear how global or regional alterations in airway resistance (Raw) and lung compliance (C) alter FOT measurements.
METHODS
A 2-compartment physical model of the respiratory system allowed to simulate variations in Raw, C, and their heterogeneity during tidal breathing in an adult human. Five-Hz respiratory system resistance (Rrs5) and reactance (Xrs5), area of reactance (AX), resonance frequency (Fresp) and intrabreath variation in Rrs5 and Xrs5 were measured by FOT. Frequency dependance of resistance could not be studied in this model. Relationships between model characteristics (Raw, C, and heterogeneity) and FOT measurements were explored by multiple regression.
RESULTS
Rrs5 and intrabreath variation in Rrs5 and Xrs5 strongly associated with model characteristics (R=0.753, 0.5 and 0.658). Associations of Xrs5, AX, and Fresp with model characteristics were weak (R=0.214, 0.349 and 0.076). Raw heterogeneity was the main determinant of Rrs5 (Coeff=0.594), AX (Coeff=0.566) and intrabreath variation in Rrs5 and Xrs5 (Coeff=0.586 and 0.732). Regional extremes in Raw strongly determined Rrs5 (Coeff=1.006). Xrs5 did not strongly associate with any model characteristic.
CONCLUSION
Raw heterogeneity and maximal regional Raw were the main determinants of FOT measurements, in particular Rrs5. Associations between C and FOT measurements were weak.
Topics: Adult; Humans; Asthma; Respiratory Function Tests; Lung; Airway Resistance; Respiration
PubMed: 37717385
DOI: 10.1016/j.resmer.2023.101027 -
Pediatric Pulmonology Nov 2023Mechanisms underlying lung dysfunction after preterm birth are poorly understood. Studying phenotypes of prematurity-associated lung disease may aid understanding of...
INTRODUCTION
Mechanisms underlying lung dysfunction after preterm birth are poorly understood. Studying phenotypes of prematurity-associated lung disease may aid understanding of underlying mechanisms. Preterm-born children with and without lung dysfunction and term controls were assessed using oscillometry before and after exercise, and after postexercise bronchodilation.
METHODS
Preterm-born children, born at gestation of 34 weeks or less, were classified into those with prematurity-associated obstructive lung disease (POLD; FEV < LLN, FEV /FVC < LLN), prematurity-associated preserved ratio of impaired spirometry (pPRISm; FEV < LLN, FEV /FVC ≥ LLN) and compared to preterm (FEV ≥ LLN) and term controls (%predicted FEV > 90%). All children underwent cardiopulmonary exercise, and oscillometry assessment at baseline, postexercise, and after postexercise bronchodilator administration.
RESULTS
From 241 participants aged 7-12 years, complete data were available from 179: 15 children with POLD and 11 with pPRISm were compared with 93 preterm and 60 term controls. POLD group, when compared to both control groups, had impaired impedance, greater resistance, more negative (greater magnitude) reactance at low frequencies, and also had decreased compliance. pPRISm group demonstrated impaired reactance and compliance compared to term controls. No differences were noted between the preterm and term controls. Exercise had little impact on oscillometry values, but children with POLD had greatest improvements after postexercise bronchodilator administration, with decreased resistance and decreased magnitude of reactance, particularly at low frequencies.
CONCLUSION
Preterm-born children with obstructive airway disease had the greatest oscillometry impairments and the largest improvements after postexercise bronchodilator compared to control groups. Oscillometry can potentially be used to identify preterm-born children with lung disease to institute treatment.
Topics: Child; Female; Humans; Infant, Newborn; Bronchodilator Agents; Oscillometry; Forced Expiratory Volume; Premature Birth; Lung; Lung Diseases; Lung Diseases, Obstructive; Spirometry; Infant, Newborn, Diseases
PubMed: 37701982
DOI: 10.1002/ppul.26658 -
BMC Pulmonary Medicine Sep 2023We conducted a retrospective observational study to explore the potential application of impulse oscillometry (IOS) as an alternative to high-resolution computed... (Observational Study)
Observational Study
BACKGROUND
We conducted a retrospective observational study to explore the potential application of impulse oscillometry (IOS) as an alternative to high-resolution computed tomography (HRCT) for detecting pulmonary involvement in patients with rheumatoid arthritis (RA) because clinically evident interstitial lung disease (ILD) and airway involvement are common in this population.
METHODS
We enrolled 72 patients with RA who underwent pulmonary function tests (PFTs) and IOS between September 2021 and September 2022. We aimed to identify the PFT and IOS variables associated with lung diseases shown on HRCT images.
RESULTS
In our cohort of 72 patients, 48 underwent HRCT; of these, 35 had airway disease or ILD and 13 showed no obvious abnormalities on HRCT. Abnormal IOS and PFT parameters were observed in 34 and 23 patients, respectively, with abnormal HRCT images. The predicted percentages for forced vital capacity, the ratio of forced expiratory volume in the first one second to forced vital capacity, and forced mid-expiratory flow value were significantly lower in patients with abnormal HRCT. Lung resistance at 5 Hz, difference in resistance between 5 and 20 Hz, resonant frequency (Fres), and reactance area were higher in these patients and reactance at 5 Hz was lower. Compared to other parameters, Fres > 14.14 was significantly associated with alterations in HRCT and may be used as an indicator for monitoring disease.
CONCLUSION
Fres > 14.14 is significantly associated with lung involvement in RA patients. Performance of spirometry with IOS is more beneficial than spirometry alone for evaluating lung involvement in RA patients.
Topics: Humans; Adult; Oscillometry; Lung Diseases, Interstitial; Respiration Disorders; Respiratory Function Tests; Arthritis, Rheumatoid
PubMed: 37684581
DOI: 10.1186/s12890-023-02615-0 -
Diseases (Basel, Switzerland) Aug 2023The COVID-19 pandemic, caused by the SARS-CoV-2 virus, has had significant impacts on pulmonary function. This study aimed to comprehensively evaluate pulmonary function...
The COVID-19 pandemic, caused by the SARS-CoV-2 virus, has had significant impacts on pulmonary function. This study aimed to comprehensively evaluate pulmonary function and structure in patients 40 days post-SARS-CoV-2 infection, employing an array of testing methodologies including spirometry, plethysmography, forced oscillometry, and CT scanning. It also sought to establish potential correlations between these metrics and evaluate if forced oscillometry could provide additional value in post-infective lung function assessment. A 40-day post-infection follow-up observational study was conducted involving 66 patients with confirmed SARS-CoV-2 infection. The results revealed decreases in FVC and FEF25-75 with the increasing severity of COVID-19. Specifically, patients with severe symptoms exhibited statistically significant decreases in FVC (mean = 86.8) compared with those with mild symptoms (mean = 106.0; = 0.018). The FEF25-75 showed a similar trend, with severe patients exhibiting a mean of 77.7 compared with 82.9 in the mild group ( = 0.017). Furthermore, resonant frequency (RF) increased with disease severity, with the severe group exhibiting a statistically significant increase (mean = 17.4) compared with the mild group (mean = 14.3; = 0.042). CT scans showed an increase in ground-glass opacities with disease severity, with 81.8% of severe patients demonstrating this finding ( = 0.037). Multiple regression analysis revealed that Reactance at 4 Hz (X4), Forced Expiratory Flow 25-75% (FEF25-75), and Resonant Frequency (RF) were significantly related to COVID-19 severity. Specifically, for each unit increase in these factors, the risk of the event was estimated to increase by a factor of 3.16, 2.09, and 1.90, respectively. Conversely, Resistance at 4 Hz (R4) and Airway Resistance (RAW) were found to significantly decrease the event hazard, highlighting their potential protective role. Spirometry, plethysmography, and forced oscillometry are effective in assessing these changes. Forced oscillometry may be particularly beneficial in identifying subtle changes in lung function post-COVID-19. Further studies are warranted to validate these findings and develop strategies to manage post-infective pulmonary changes in SARS-CoV-2 patients.
PubMed: 37606473
DOI: 10.3390/diseases11030102 -
Journal of Clinical Medicine Aug 2023Magnetic resonance imaging (MRI) of the chest is becoming more available in the detection and monitoring of early changes in lung function and structure in patients with...
Magnetic resonance imaging (MRI) of the chest is becoming more available in the detection and monitoring of early changes in lung function and structure in patients with cystic fibrosis (CF). The aim of this study was to assess the relationship between pulmonary function tests (PFT) and perfusion deficits in CF children measured by MRI. We performed a retrospective analysis of the perfusion lung MRI scans and the results of spirometry, oscillometry, body plethysmography, single-breath carbon monoxide uptake, and multiple-breath washout technique (MBW). There were statistically significant correlations between the MRI perfusion scores and MBW parameters (2.5% LCI, M1/M0, M2/M0), spirometry parameters (FEV, FVC, FEF25/75), reactance indices in impulse oscillometry (X5Hz, X10Hz), total lung capacity (TLC) measured in single breath carbon monoxide uptake, markers of air-trapping in body plethysmography (RV, RV/TLC), and the diffusing capacity of the lungs for carbon monoxide. We also observed significant differences in the aforementioned PFT variables between the patient groups divided based on perfusion scores. We noted a correlation between markers of functional lung deficits measured by the MRI and PFTs in CF children. MRI perfusion abnormalities were reflected sooner in the course of the disease than PFT abnormalities.
PubMed: 37568538
DOI: 10.3390/jcm12155136 -
Diagnostics (Basel, Switzerland) Jul 2023Primary ciliary dyskinesia (PCD) is an autosomal recessive disorder that results from the dysfunction of motile cilia, which can cause chronic upper and lower...
Primary ciliary dyskinesia (PCD) is an autosomal recessive disorder that results from the dysfunction of motile cilia, which can cause chronic upper and lower respiratory infections leading to bronchiectasis. However, there is a need for additional tools to monitor the progression of bronchiectasis in PCD. The forced oscillation technique (FOT) is an effort-independent lung function test that can be used to evaluate respiratory mechanics. In this retrospective study, we aimed to describe the radiographic findings associated with respiratory impedance (resistance (Rrs) and reactance (Xrs)) measured by FOT in six adult PCD patients and one pediatric with the ( (c.921+3_921+6delAAGT (intronic)) founder mutation. We compared the radiographic findings on a high-resolution chest computed tomography (CT) scan with the FOT results. Our findings suggest that respiratory impedance measured by FOT may be a valuable tool for detecting and monitoring the progression of bronchiectasis in PCD patients with the ( (c.921+3_921+6delAAGT (intronic)) founder mutation. However, further research is necessary to validate these results and determine the sensitivity and specificity of bronchiectasis monitoring in PCD patients with other genetic mutations.
PubMed: 37443681
DOI: 10.3390/diagnostics13132287 -
Respiratory Medicine Oct 2023Bronchial thermoplasty is an effective intervention to improve respiratory symptoms and to reduce the rate of exacerbations in uncontrolled severe asthma. A reduction in...
INTRODUCTION
Bronchial thermoplasty is an effective intervention to improve respiratory symptoms and to reduce the rate of exacerbations in uncontrolled severe asthma. A reduction in airway smooth muscle is arguably the most widely discussed mechanisms accounting for these clinical benefits. Yet, this smooth muscle reduction should also translate into an impaired response to bronchodilator drugs. This study was designed to address this question.
METHODS
Eight patients with clinical indication for thermoplasty were studied. They were uncontrolled severe asthmatics despite optimal environmental control, treatment of comorbidities, and the use of high-dose inhaled corticosteroids and long-acting β-agonists. Lung function measured by spirometry and respiratory mechanics measured by oscillometry were examined pre- and post-bronchodilator (salbutamol, 400 μg), both before and at least 1 year after thermoplasty.
RESULTS
Consistent with previous studies, thermoplasty yielded no benefits in terms of baseline lung function and respiratory mechanics, despite improving symptoms based on two asthma questionnaires (ACQ-5 and ACT-5). The response to salbutamol was also not affected by thermoplasty based on spirometric readouts, including forced expiratory volume in 1 s (FEV), forced vital capacity (FVC), and FEV/FVC ratio. However, a significant interaction was observed between thermoplasty and salbutamol for two oscillometric readouts, namely reactance at 5 Hz (X) and reactance area (Ax), showing an attenuated response to salbutamol after thermoplasty.
CONCLUSIONS
Thermoplasty attenuates the response to a bronchodilator. We argue that this result is a physiological proof of therapeutic efficacy, consistent with the well-described effect of thermoplasty in reducing the amount of airway smooth muscle.
Topics: Humans; Bronchodilator Agents; Bronchial Thermoplasty; Asthma; Albuterol; Adrenal Cortex Hormones; Forced Expiratory Volume
PubMed: 37422022
DOI: 10.1016/j.rmed.2023.107340 -
Environmental Research Oct 2023Poly- and perfluoroalkyl substances (PFAS) are used in a wide range of products. Experimental studies suggested impaired lung development and pro-inflammatory response...
BACKGROUND
Poly- and perfluoroalkyl substances (PFAS) are used in a wide range of products. Experimental studies suggested impaired lung development and pro-inflammatory response following exposure to some PFAS. We aimed to assess the associations between prenatal exposure to PFAS and children respiratory health.
METHODS
The study is based on 433 mother-child pairs. 26 PFAS were measured in maternal serum collected during pregnancy. Lung function parameters were measured at 2 months using tidal breathing flow-volume loops and multiple-breath nitrogen washout and at 36 months using oscillometry. Incidence of respiratory health diseases (asthma, wheeze, bronchitis, bronchiolitis) in the first 36 months of life was assessed by repeated questionnaires. A cluster-based analysis was applied to identify prenatal PFAS exposure patterns. Adjusted linear and logistic regressions were performed to assess the associations between PFAS exposure patterns as well as individual PFAS, and each respiratory health parameter.
RESULTS
We excluded 13 PFAS due to low quantification (<5%). Relying on the 13 remaining PFAS, we identified three exposure clusters, characterized by low (N = 163), medium (N = 236) and high (N = 51) pregnancy PFAS concentrations. Compared to children belonging to the low exposure group, children in the moderate exposure group had higher reactance at 7 Hz (X) and lower frequency dependence of resistance between 7 Hz and 19 Hz (R) at 36 months, suggesting better lung function. No association of any exposure metric was detected with respiratory diseases in the first 3 years of life.
CONCLUSIONS
Our study relying on both mixture and uni-pollutant analyses, does not provide evidence for a deleterious effect of prenatal PFAS exposure on respiratory health at an early age.
Topics: Pregnancy; Female; Humans; Prenatal Exposure Delayed Effects; Fluorocarbons; Environmental Pollutants; Asthma; Incidence; Alkanesulfonic Acids
PubMed: 37406719
DOI: 10.1016/j.envres.2023.116544