-
Advanced Optical Materials Apr 2024This paper showcases an experimental demonstration of near-field optical trapping and dynamic manipulation of an individual extracellular vesicle. This is accomplished...
This paper showcases an experimental demonstration of near-field optical trapping and dynamic manipulation of an individual extracellular vesicle. This is accomplished through the utilization of a plasmonic dielectric nanoantenna designed to support an optical anapole state-a non-radiating optical state resulting from the destructive interference between electric and toroidal dipoles in the far-field, leading to robust near-field enhancement. To further enhance the field intensity associated with the optical anapole state, a plasmonic mirror is incorporated, thereby boosting trapping capabilities. In addition to demonstrating near-field optical trapping, the study achieves dynamic manipulation of extracellular vesicles by harnessing the thermoelectric effect. This effect is induced in the presence of an ionic surfactant, cetyltrimethylammonium chloride (CTAC), combined with plasmonic heating. Furthermore, the thermoelectric effect improves trapping stability by introducing a wide and deep trapping potential. In summary, our hybrid plasmonic-dielectric trapping platform offers a versatile approach for actively transporting, stably trapping, and dynamically manipulating individual extracellular vesicles.
PubMed: 38899010
DOI: 10.1002/adom.202302603 -
Nature Communications Jun 2024Phototransduction involves changes in concentration of ions and other solutes within photoreceptors and in subretinal space, which affect osmotic pressure and the...
Phototransduction involves changes in concentration of ions and other solutes within photoreceptors and in subretinal space, which affect osmotic pressure and the associated water flow. Corresponding expansion and contraction of cellular layers can be imaged using optoretinography (ORG), based on phase-resolved optical coherence tomography (OCT). Until now, ORG could reliably detect only photoisomerization and phototransduction in photoreceptors, primarily in cones under bright stimuli. Here, by employing a phase-restoring subpixel motion correction algorithm, which enables imaging of the nanometer-scale tissue dynamics during minute-long recordings, and unsupervised learning of spatiotemporal patterns, we discover optical signatures of the other retinal structures' response to visual stimuli. These include inner and outer segments of rod photoreceptors, retinal pigment epithelium, and subretinal space in general. The high sensitivity of our technique enables detection of the retinal responses to dim stimuli: down to 0.01% bleach level, corresponding to natural levels of scotopic illumination. We also demonstrate that with a single flash, the optoretinogram can map retinal responses across a 12° field of view, potentially replacing multifocal electroretinography. This technique expands the diagnostic capabilities and practical applicability of optoretinography, providing an alternative to electroretinography, while combining structural and functional retinal imaging in the same OCT machine.
Topics: Tomography, Optical Coherence; Animals; Retinal Pigment Epithelium; Retinal Rod Photoreceptor Cells; Retina; Light; Photic Stimulation; Algorithms; Male
PubMed: 38898002
DOI: 10.1038/s41467-024-49014-5 -
BioRxiv : the Preprint Server For... Jun 2024Tanning bed users have a significantly increased risk of melanoma, but it remains unclear how indoor tanning drives melanomagenesis. Tanning bed radiation is often...
BACKGROUND
Tanning bed users have a significantly increased risk of melanoma, but it remains unclear how indoor tanning drives melanomagenesis. Tanning bed radiation is often thought of as a substitute for natural UV radiation despite differences in the maximum doses, UV content, body sites exposed, and patterns of melanoma that arise.
METHODS
To better understand the epidemiologic trends and etiology of melanoma associated with tanning bed use, we described the patterns of melanoma in patients with quantifiable tanning bed usage and performed exome sequencing of 182 melanocytes from normal skin of a subset of these patients.
RESULTS
Tanning bed users were more likely than non-users to have melanoma on body sites with low cumulative levels of sun damage and were more likely to have multiple melanomas. The melanocytes in normal appearing skin from tanning bed users had higher mutation burdens, a higher proportion of melanocytes with pathogenic mutations, and distinct mutational signatures. These differences were most prominent over body sites that experience comparatively less exposure to natural sunlight.
CONCLUSIONS
We conclude that tanning bed radiation induces melanoma by increasing the mutation burden of melanocytes and by mutagenizing a broader field of melanocytes than are typically exposed to natural sunlight. The unique signatures of mutations in skin cells of tanning users may be attributable to the distinct spectra of radiation emitted from solariums.
PubMed: 38895302
DOI: 10.1101/2024.06.04.597225 -
Sensors (Basel, Switzerland) May 2024In this paper, a patch array antenna with wideband circular polarization and high gain is proposed by utilizing a hybrid metasurface (MS). A corner-cut slotted patch...
In this paper, a patch array antenna with wideband circular polarization and high gain is proposed by utilizing a hybrid metasurface (MS). A corner-cut slotted patch antenna was chosen as the source due to the possible generation of CP mode. The hybrid MS (HMS), consisting of a receiver MS (RMS) arranged in a 2 × 2 array of squared patches and a linear-to-circular polarization conversion (LCPC) MS surrounding it was then utilized as the superstrate driven by the source. The LCPC MS cell is a squared-corner-cut patch with a 45° oblique slot etched, which has the capability for wideband LCPC. The LCPC unit cell possesses wideband PC capabilities, as demonstrated by the surface current analysis and S-parameter simulations conducted using a Floquet-port setup. The LP EM wave radiated by the source antenna was initially received by the RMS, then converted to a CP wave as it passed through the LCPC MS, and ultimately propagated into space. To further enhance the LCPC properties, an improved HMS (IHMS) was then proposed with four cells cut at the corners, based on the original HMS design. To verify this design, both CMA and E-field were utilized to analyze the three MSs, indicating that the IHMS possessed a wideband LCPC capability compared to the other two MSs. The proposed antenna was then arranged in a 2 × 2 array with sequential rotation to further enhance its properties. As demonstrated by the measurements, the array antenna achieved an S11 bandwidth of 60.5%, a 3 dB AR bandwidth of 2.85 GHz, and a peak gain of 15.1 dBic, all while maintaining a low profile of only 0.09λ.
PubMed: 38894301
DOI: 10.3390/s24113510 -
Sensors (Basel, Switzerland) May 2024Wearable sensors are rapidly gaining influence in the diagnostics, monitoring, and treatment of disease, thereby improving patient outcomes. In this review, we aim to... (Review)
Review
Wearable sensors are rapidly gaining influence in the diagnostics, monitoring, and treatment of disease, thereby improving patient outcomes. In this review, we aim to explore how these advances can be applied to magnetic resonance imaging (MRI). We begin by (i) introducing limitations in current flexible/stretchable RF coils and then move to the broader field of flexible sensor technology to identify translatable technologies. To this goal, we discuss (ii) emerging materials currently used for sensor substrates, (iii) stretchable conductive materials, (iv) pairing and matching of conductors with substrates, and (v) implementation of lumped elements such as capacitors. Applicable (vi) fabrication methods are presented, and the review concludes with a brief commentary on (vii) the implementation of the discussed sensor technologies in MRI coil applications. The main takeaway of our research is that a large body of work has led to exciting new sensor innovations allowing for stretchable wearables, but further exploration of materials and manufacturing techniques remains necessary, especially when applied to MRI diagnostics.
Topics: Magnetic Resonance Imaging; Wearable Electronic Devices; Humans; Radio Waves; Equipment Design; Electric Conductivity
PubMed: 38894182
DOI: 10.3390/s24113390 -
Sensors (Basel, Switzerland) May 2024The refractive index of a liquid serves as a fundamental parameter reflecting its composition, thereby enabling the determination of component concentrations in various...
The refractive index of a liquid serves as a fundamental parameter reflecting its composition, thereby enabling the determination of component concentrations in various fields such as chemical research, the food industry, and environmental monitoring. Traditional methods for refractive index (RI) measurement rely on light deflection angles at interfaces between the liquid and a material with a known refractive index. In this paper, the authors present a new differential refractometer for the highly sensitive measurement of RI differences between two liquid samples. Using a configuration with two cells equipped with flat parallel plates as measuring elements, the instrument facilitates accurate analysis. Namely, the sensor signals from both the solution and the solvent cuvette are generated simultaneously with one laser pulse, reducing the possible fluctuations in the laser radiation intensity. Our evaluation shows the high sensitivity of RI measurements <7×10-6), so this differential refractometer can be proposed not only as a high-sensitivity sensing tool that can be used for mobile detection of nanoparticles in solution samples but also to determine the level of environmental nano-pollution using water (including rain, snow) samples from various natural as well as industrial sources, thus helping to solve some important environmental problems.
PubMed: 38894127
DOI: 10.3390/s24113340 -
Molecules (Basel, Switzerland) May 2024This work describes the development of a reusable 2D detector based on radiochromic reaction for radiotherapy dosimetric measurements. It consists of a radiochromic gel...
This work describes the development of a reusable 2D detector based on radiochromic reaction for radiotherapy dosimetric measurements. It consists of a radiochromic gel dosimeter in a cuboidal plastic container, scanning with a flatbed scanner, and data processing using a dedicated software package. This tool is assessed using the example of the application of the coincidence test of radiation and mechanical isocenters for a medical accelerator. The following were examined: scanning repeatability and image homogeneity, the impact of image processing on data processing in coincidence tests, and irradiation conditions-monitor units per radiation beam and irradiation field are selected. Optimal conditions for carrying out the test are chosen: (i) the multi-leaf collimator gap should preferably be 5 mm for 2D star shot irradiation, (ii) it is recommended to apply ≥2500-≤5000 MU per beam to obtain a strong signal enabling easy data processing, (iii) Mean filter can be applied to the images to improve calculations. An approach to dosimeter reuse with the goal of reducing costs is presented; the number of reuses is related to the MUs per beam, which, in this study, is about 5-57 for 30,000-2500 MU per beam (four fields). The proposed reusable system was successfully applied to the coincidence tests, confirming its suitability as a new potential quality assurance tool in radiotherapy.
Topics: Radiation, Ionizing; Radiometry; Gels; Radiotherapy; Radiotherapy Dosage; Radiation Dosimeters; Particle Accelerators
PubMed: 38893435
DOI: 10.3390/molecules29112558 -
Cancers Jun 2024This review article investigates the utilization of MRS in the setting of cervical cancer. A variety of different techniques have been used in this space including... (Review)
Review
This review article investigates the utilization of MRS in the setting of cervical cancer. A variety of different techniques have been used in this space including single-voxel techniques such as point-resolved spectroscopy (PRESS) and stimulated echo acquisition mode spectroscopy (STEAM). Furthermore, the experimental parameters for these acquisitions including field strength, repetition times (TR), and echo times (TE) vary greatly. This study critically examines eleven MRS studies that focus on cervical cancer. Out of the eleven studies, ten studies utilized PRESS acquisition, while the remaining study used STEAM acquisition. These studies generally showed that the choline signal is altered in cervical cancer (4/11 studies), the lipid signal is generally increased in cervical cancer or the lipid distribution is changed (5/11 studies), and that diffusion-weighted imaging (DWI) can quantitatively detect lower apparent diffusion coefficient (ADC) values in cervical cancer (2/11 studies). Two studies also investigated the role of MRS for monitoring treatment response and demonstrated mixed results regarding choline signal, and one of these studies showed increased lipid signal for non-responders. There are several new MRS technologies that have yet to be implemented for cervical cancer including advanced spectroscopic imaging and artificial intelligence, and those technologies are also discussed in the article.
PubMed: 38893260
DOI: 10.3390/cancers16112141 -
Cancers May 2024Pediatric patients with metastatic and/or recurrent solid tumors have poor survival outcomes despite standard-of-care systemic therapy. Stereotactic ablative radiation...
BACKGROUND
Pediatric patients with metastatic and/or recurrent solid tumors have poor survival outcomes despite standard-of-care systemic therapy. Stereotactic ablative radiation therapy (SABR) may improve tumor control. We report the outcomes with the use of SABR in our pediatric solid tumor population.
METHODS
This was a single-institutional study in patients < 30 years treated with SABR. The primary endpoint was local control (LC), while the secondary endpoints were progression-free survival (PFS), overall survival (OS), and toxicity. The survival analysis was performed using Kaplan-Meier estimates in R v4.2.3.
RESULTS
In total, 48 patients receiving 135 SABR courses were included. The median age was 15.6 years (interquartile range, IQR 14-23 y) and the median follow-up was 18.1 months (IQR: 7.7-29.1). The median SABR dose was 30 Gy (IQR 25-35 Gy). The most common primary histologies were Ewing sarcoma (25%), rhabdomyosarcoma (17%), osteosarcoma (13%), and central nervous system (CNS) gliomas (13%). Furthermore, 57% of patients had oligometastatic disease (≤5 lesions) at the time of SABR. The one-year LC, PFS, and OS rates were 94%, 22%, and 70%, respectively. No grade 4 or higher toxicities were observed, while the rates of any grade 1, 2, and 3 toxicities were 11.8%, 3.7%, and 4.4%, respectively. Patients with oligometastatic disease, lung, or brain metastases and those who underwent surgery for a metastatic site had a significantly longer PFS. LC at 1-year was significantly higher for patients with a sarcoma histology (95.7% vs. 86.5%, = 0.01) and for those who received a biological equivalent dose (BED10) > 48 Gy (100% vs. 91.2%, = 0.001).
CONCLUSIONS
SABR is well tolerated in pediatric patients with 1-year local failure and OS rates of <10% and 70%, respectively. Future studies evaluating SABR in combination with systemic therapy are needed to address progression outside of the irradiated field.
PubMed: 38893209
DOI: 10.3390/cancers16112090 -
International Journal of Molecular... May 2024The primary emphasis of photoimmunology is the impact of nonionizing radiation on the immune system. With the development of terahertz (THz) and sub-terahertz (sub-THz)...
The primary emphasis of photoimmunology is the impact of nonionizing radiation on the immune system. With the development of terahertz (THz) and sub-terahertz (sub-THz) technology, the biological effects of this emerging nonionizing radiation, particularly its influence on immune function, remain insufficiently explored but are progressively attracting attention. Here, we demonstrated that 0.1 sub-THz radiation can modulate the immune system and alleviate symptoms of arthritis in collagen-induced arthritis (CIA) mice through a nonthermal manner. The application of 0.1 sub-THz irradiation led to a decrease in proinflammatory factors within the joints and serum, reducing the levels of blood immune cells and the quantity of splenic CD4 T cells. Notably, 0.1 sub-THz irradiation restored depleted Treg cells in CIA mice and re-established the Th17/Treg equilibrium. These findings suggested that sub-THz irradiation plays a crucial role in systemic immunoregulation. Further exploration of its immune modulation mechanisms revealed the anti-inflammatory properties of 0.1 sub-THz on LPS-stimulated skin keratinocytes. Through the reduction in NF-κB signaling and NLRP3 inflammasome activation, 0.1 sub-THz irradiation effectively decreased the production of inflammatory factors and immune-active substances, including IL-1β and PGE, in HaCaT cells. Consequently, 0.1 sub-THz irradiation mitigated the inflammatory response and contributed to the maintenance of immune tolerance in CIA mice. This research provided significant new evidence supporting the systemic impacts of 0.1 sub-THz radiation, particularly on the immune system. It also enhanced the field of photoimmunology and offered valuable insights into the potential biomedical applications of 0.1 sub-THz radiation for treating autoimmune diseases.
Topics: Animals; Arthritis, Experimental; Mice; Terahertz Radiation; Anti-Inflammatory Agents; Male; NLR Family, Pyrin Domain-Containing 3 Protein; Inflammasomes; NF-kappa B; Mice, Inbred DBA; T-Lymphocytes, Regulatory; Humans; Signal Transduction; Keratinocytes
PubMed: 38892148
DOI: 10.3390/ijms25115963