-
Cureus Sep 2023The current guidelines state that propafenone can be used in combination with a beta-blocker or a calcium channel blocker for pharmacologic cardioversion of recent-onset...
The current guidelines state that propafenone can be used in combination with a beta-blocker or a calcium channel blocker for pharmacologic cardioversion of recent-onset atrial fibrillation in patients without structural heart disease. To prevent the conversion from atrial fibrillation to atrial flutter with a rapid ventricular rate, it is recommended to administer propafenone following the administration of a beta-blocker or a calcium channel blocker. However, this combination carries the potential risk of cardiogenic shock. There are several scenarios where this combination can lead to shock, attributed to the variable pharmacokinetics of propafenone among individuals and its significant drug interactions with commonly used AV nodal blockers, such as metoprolol and diltiazem. Additionally, a significant proportion of the population has genetic polymorphisms that affect the metabolism of these medications. While pill-in-the-pocket propafenone is also employed in outpatient settings, unexpected severe and life-threatening reactions have been reported. In this context, we present a case report of severe propafenone toxicity in a closely monitored inpatient setting aimed at converting atrial fibrillation.
PubMed: 37908936
DOI: 10.7759/cureus.46282 -
World Journal of Cardiology Sep 2023Coronavirus disease 2019 (COVID-19) caused by the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has resulted in a worldwide health crisis since it first...
BACKGROUND
Coronavirus disease 2019 (COVID-19) caused by the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has resulted in a worldwide health crisis since it first appeared. Numerous studies demonstrated the virus's predilection to cardiomyocytes; however, the effects that COVID-19 has on the cardiac conduction system still need to be fully understood.
AIM
To analyze the impact that COVID-19 has on the odds of major cardiovascular complications in patients with new onset heart blocks or bundle branch blocks (BBB).
METHODS
The 2020 National Inpatient Sample (NIS) database was used to identify patients admitted for COVID-19 pneumonia with and without high-degree atrioventricular blocks (HDAVB) and right or left BBB utilizing ICD-10 codes. The patients with pre-existing pacemakers, suggestive of a prior diagnosis of HDAVB or BBB, were excluded from the study. The primary outcome was inpatient mortality. Secondary outcomes included total hospital charges (THC), the length of hospital stay (LOS), and other major cardiac outcomes detailed in the Results section. Univariate and multivariate regression analyses were used to adjust for confounders with Stata version 17.
RESULTS
A total of 1058815 COVID-19 hospitalizations were identified within the 2020 NIS database, of which 3210 (0.4%) and 17365 (1.6%) patients were newly diagnosed with HDAVB and BBB, respectively. We observed a significantly higher odds of in-hospital mortality, cardiac arrest, cardiogenic shock, sepsis, arrythmias, and acute kidney injury in the COVID-19 and HDAVB group. There was no statistically significant difference in the odds of cerebral infarction or pulmonary embolism. Encounters with COVID-19 pneumonia and newly diagnosed BBB had a higher odds of arrythmias, acute kidney injury, sepsis, need for mechanical ventilation, and cardiogenic shock than those without BBB. However, unlike HDAVB, COVID-19 pneumonia and BBB had no significant impact on mortality compared to patients without BBB.
CONCLUSION
In conclusion, there is a significantly higher odds of inpatient mortality, cardiac arrest, cardiogenic shock, sepsis, acute kidney injury, supraventricular tachycardia, ventricular tachycardia, THC, and LOS in patients with COVID-19 pneumonia and HDAVB as compared to patients without HDAVB. Likewise, patients with COVID-19 pneumonia in the BBB group similarly have a higher odds of supraventricular tachycardia, atrial fibrillation, atrial flutter, ventricular tachycardia, acute kidney injury, sepsis, need for mechanical ventilation, and cardiogenic shock as compared to those without BBB. Therefore, it is essential for healthcare providers to be aware of the possible worse predicted outcomes that patients with new-onset HDAVB or BBB may experience following SARS-CoV-2 infection.
PubMed: 37900263
DOI: 10.4330/wjc.v15.i9.448 -
World Journal of Cardiology Sep 2023Cardiac magnetic resonance (CMR) imaging could enable major advantages when guiding in real-time cardiac electrophysiology procedures offering high-resolution anatomy,... (Review)
Review
Cardiac magnetic resonance (CMR) imaging could enable major advantages when guiding in real-time cardiac electrophysiology procedures offering high-resolution anatomy, arrhythmia substrate, and ablation lesion visualization in the absence of ionizing radiation. Over the last decade, technologies and platforms for performing electrophysiology procedures in a CMR environment have been developed. However, performing procedures outside the conventional fluoroscopic laboratory posed technical, practical and safety concerns. The development of magnetic resonance imaging compatible ablation systems, the recording of high-quality electrograms despite significant electromagnetic interference and reliable methods for catheter visualization and lesion assessment are the main limiting factors. The first human reports, in order to establish a procedural workflow, have rationally focused on the relatively simple typical atrial flutter ablation and have shown that CMR-guided cavotricuspid isthmus ablation represents a valid alternative to conventional ablation. Potential expansion to other more complex arrhythmias, especially ventricular tachycardia and atrial fibrillation, would be of essential impact, taking into consideration the widespread use of substrate-based strategies. Importantly, all limitations need to be solved before application of CMR-guided ablation in a broad clinical setting.
PubMed: 37900261
DOI: 10.4330/wjc.v15.i9.415 -
PLoS Medicine Oct 2023Although previous evidence has suggested an increased risk of cardiovascular disease (CVD) in patients with inflammatory bowel disease (IBD), its association with...
BACKGROUND
Although previous evidence has suggested an increased risk of cardiovascular disease (CVD) in patients with inflammatory bowel disease (IBD), its association with arrhythmias is inconclusive. In this study, we aimed to explore the long-term risk of arrhythmias in patients with IBD.
METHODS AND FINDINGS
Through a nationwide histopathology cohort, we identified patients with biopsy-confirmed IBD in Sweden during 1969 to 2017, including Crohn's disease (CD: n = 24,954; median age at diagnosis: 38.4 years; female: 52.2%), ulcerative colitis (UC: n = 46,856; 42.1 years; 46.3%), and IBD-unclassified (IBD-U: n = 12,067; 43.8 years; 49.6%), as well as their matched reference individuals and IBD-free full siblings. Outcomes included overall and specific arrhythmias (e.g., atrial fibrillation/flutter, bradyarrhythmias, other supraventricular arrhythmias, and ventricular arrhythmias/cardiac arrest). Flexible parametric survival models estimated hazard ratios (aHR) with 95% confidence intervals (95% CIs), after adjustment for birth year, sex, county of residence, calendar year, country of birth, educational attainment, number of healthcare visits, and cardiovascular-related comorbidities. Over a median of approximately 10 years of follow-up, 1,904 (7.6%) patients with CD, 4,154 (8.9%) patients with UC, and 990 (8.2%) patients with IBD-U developed arrhythmias, compared with 6.7%, 7.5%, and 6.0% in reference individuals, respectively. Compared with reference individuals, overall arrhythmias were increased in patients with CD [54.6 versus 46.1 per 10,000 person-years; aHR = 1.15 (95% CI [1.09, 1.21], P < 0.001)], patients with UC [64.7 versus 53.3 per 10,000 person-years; aHR = 1.14 (95% CI [1.10, 1.18], P < 0.001)], and patients with IBD-U [78.1 versus 53.5 per 10,000 person-years; aHR = 1.30 (95% CI [1.20, 1.41], P < 0.001)]. The increased risk persisted 25 years after diagnosis, corresponding to 1 extra arrhythmia case per 80 CD, 58 UC, and 29 IBD-U cases over the same period. Patients with IBD also had a significantly increased risk of specific arrhythmias, except for bradyarrhythmias. Sibling comparison analyses confirmed the main findings. Study limitations include lack of clinical data to define IBD activity, not considering the potential role of IBD medications and disease activity, and the potential residual confounding from unmeasured factors for arrhythmias.
CONCLUSIONS
In this study, we observed that patients with IBD were at an increased risk of developing arrhythmias. The excess risk persisted even 25 years after IBD diagnosis. Our findings indicate a need for awareness of this excess risk among healthcare professionals.
Topics: Humans; Female; Adult; Siblings; Cohort Studies; Bradycardia; Inflammatory Bowel Diseases; Atrial Fibrillation
PubMed: 37856566
DOI: 10.1371/journal.pmed.1004305 -
PloS One 2023Management of acute myocardial infarction (AMI) and cardiac arrhythmias in prehospital settings is largely determined by providers of emergency medical services (EMS)...
BACKGROUND
Management of acute myocardial infarction (AMI) and cardiac arrhythmias in prehospital settings is largely determined by providers of emergency medical services (EMS) who can proficiently interpret the electrocardiography (ECG). The aim of this study was to assess the ECG competency of EMS providers in Saudi Arabia.
METHODS
Between Aug and Sep 2022, we invited all EMS providers working for the Saudi Red Crescent Authority in Makkah, Riyadh, and Sharqiyah regions to complete a cross-sectional survey. The survey was used to assess the ability of EMS providers to interpret 12 ECG strips. Characteristics and ECG competency were summarized using descriptive statistics. Differences in ECG competency across paramedics with lower and higher qualifications were assessed.
RESULTS
During the study period, 231 participants completed the survey, and all were included. The overall mean age was 33.4, and most participants were male (94.8%). Nearly half of the participants were paramedics with an associate degree and 46.4% were paramedics with higher degrees. The average rate of correct answers to the 12 ECG strips was 43.3% (95% CI: 35.4%, 51.3%). Atrial flutter, ventricular fibrillation, atrial fibrillation, 3rd degree heart block, and ventricular tachycardia were identified by 52.8%, 60.2%, 42.0%, 40.7%, and 49.4% of the participants, respectively. The strip with an AMI was identified by 41.1%, while a pathological Q wave and ventricular extrasystole were identified by 19.1% and 24.7%, respectively. Paramedics with higher qualifications were as 28.0%-61.0% more likely to correctly interpret the 12 ECG strips compared to those with an associate degree (p-value across all variables was ≤ 0.001).
CONCLUSION
While the majority of participants in our region were unable to correctly answer the 12 ECG questionnaire, paramedics with higher qualifications were. Our study indicates that there is a need for evidenced-based ECG curricula targeting different levels of EMS professionals.
Topics: Humans; Male; Adult; Female; Cross-Sectional Studies; Saudi Arabia; Emergency Medical Services; Myocardial Infarction; Electrocardiography; Emergency Medical Technicians
PubMed: 37856426
DOI: 10.1371/journal.pone.0292868 -
Cureus Sep 2023Endomyocardial fibrosis (EMF) is a rare restrictive cardiomyopathy in non-tropical areas. It is seen in most of the patients living in or coming from tropical areas, and...
Endomyocardial fibrosis (EMF) is a rare restrictive cardiomyopathy in non-tropical areas. It is seen in most of the patients living in or coming from tropical areas, and is rarely seen in patients who have never visited these areas. It is characterized by fibrotic thickening of the endocardium, predominantly affecting the ventricular apices and inflow tracts. Although thrombus formation is a known complication in various cardiac conditions such as atrial fibrillation, atrial flutter, ventricular heart disease, and patent foramen ovale, the occurrence of bilateral thrombus in EMF is exceptionally rare. We present a case report describing a unique finding of bilateral ventricular thrombus in a patient diagnosed with EMF, highlighting the clinical presentation, diagnostic approach, and management challenges associated with this rare phenomenon.
PubMed: 37849579
DOI: 10.7759/cureus.45358 -
Cureus Sep 2023Catheter ablation has become an important treatment strategy for the management of atrial fibrillation (AF) in symptomatic patients. Pulmonary vein isolation (PVI) is...
Catheter ablation has become an important treatment strategy for the management of atrial fibrillation (AF) in symptomatic patients. Pulmonary vein isolation (PVI) is increasingly used to restore rhythm in patients with AF and flutter. The serious procedural complication rate has significantly reduced over time and most patients undergo PVI without any adverse events. We present the case of a 70-year-old man with symptomatic AF who underwent elective PVI that was complicated by large pericardial effusion from left atrial appendage (LAA) perforation resulting in cardiac tamponade requiring emergency pericardiocentesis followed by sternotomy to suture the LAA. The perforated LAA was sutured and the LAA was closed surgically through sternotomy by using AtriClip and a large amount of blood was evacuated achieving good cardiac output and hemodynamic stability. A surgical PVI was performed twice restoring normal sinus rhythm. The patient was discharged home, however, he returned to the hospital a few days later with atrial flutter with a rapid ventricular response. He underwent direct current cardioversion (DCCV) and remained in sinus rhythm during the rest of his admission. His bisoprolol was switched to Sotalol to maintain normal sinus rhythm and he was discharged home with outpatient follow-up.
PubMed: 37829980
DOI: 10.7759/cureus.44989 -
Journal of Cardiovascular Development... Aug 2023Ambulatory 24-72 h Holter ECG monitoring is recommended for patients with suspected arrhythmias, which are often transitory and might remain unseen in resting standard...
Ambulatory 24-72 h Holter ECG monitoring is recommended for patients with suspected arrhythmias, which are often transitory and might remain unseen in resting standard 12-lead ECG. Holter manufacturers provide software diagnostic tools to assist clinicians in evaluating these large amounts of data. Nevertheless, the identification of short arrhythmia events and differentiation of the arrhythmia type might be a problem in limited Holter ECG leads. This observational clinical study aims to explore a novel and weakly investigated ECG modality integrated into a commercial diagnostic tool ECHOView (medilog DARWIN 2, Schiller AG, Switzerland), while used for the interpretation of long-term Holter-ECG records by a cardiologist. The ECHOView transformation maps the beat waveform amplitude to a color-coded bar. One ECHOView page integrates stacked color bars of about 1740 sequential beats aligned by R-peak in a window (R ± 750 ms). The collected 3-lead Holter ECG recordings from 86 patients had a valid duration of 21 h 20 min (19 h 30 min-22 h 45 min), median (quartile range). The ECG rhythm was reviewed with 3491 (3192-3723) standard-grid ECG pages and a substantially few number of 51 (44-59) ECHOView pages that validated the ECHOView compression ratio of 67 (59-74) times. Comments on the ECG rhythm and ECHOView characteristic patterns are provided for 14 examples representative of the most common rhythm disorders seen in our population, including supraventricular arrhythmias (supraventricular extrasystoles, paroxysmal supraventricular arrhythmia, sinus tachycardia, supraventricular tachycardia, atrial fibrillation, and flutter) and ventricular arrhythmias (ventricular extrasystoles, non-sustained ventricular tachycardia). In summary, the ECHOView color map transforms the ECG modality into a novel diagnostic image of the patient's rhythm that is comprehensively interpreted by a cardiologist. ECHOView has the potential to facilitate the manual overview of Holter ECG recordings, to visually identify short-term arrhythmia episodes, and to refine the diagnosis, especially in high-rate arrhythmias.
PubMed: 37754789
DOI: 10.3390/jcdd10090360 -
World Journal of Clinical Cases Aug 2023Atrial arrhythmias such as paroxysmal supraventricular tachycardia (PSVT) and atrial flutter (AF) are common in the perioperative setting. They commonly resolve...
BACKGROUND
Atrial arrhythmias such as paroxysmal supraventricular tachycardia (PSVT) and atrial flutter (AF) are common in the perioperative setting. They commonly resolve spontaneously. However, occasionally, they may continually progress to fatal arrhythmias or cause complications. Therefore, prompt and appropriate management is important.
CASE SUMMARY
A 46-year-old female patient diagnosed with cervical C6-7 radiculopathy characterized by decreased sensation in the right third, fourth and fifth fingers underwent C6-7 anterior cervical disc fusion surgery. Electrocardiography showed PSVT and ventricular tachycardia during C6-7 disc retraction. However, the patient remained stable. Initial treatment with esmolol and lidocaine for ventricular tachycardia was ineffective. Carotid massage and Valsalva maneuver were attempted but PSVT did not resolve. The surgery was paused, and the patient's fraction of inspired oxygen was set to 100%. Adenosine was administered for pharmacological management of PSVT. The arrhythmia temporarily resolved. However, it then transformed into AF. Diltiazem was administered, which briefly decreased blood pressure, which immediately recovered. Surgery resumed while the patient was in normal sinus rhythm. She was discharged safely on postoperative day 6 without complications or abnormalities. Currently, she is living a healthy life without arrhythmia recurrence.
CONCLUSION
Ganglia associated with cardiac arrhythmias in the surgical site should be identified during cervical spine surgery.
PubMed: 37727714
DOI: 10.12998/wjcc.v11.i24.5789 -
Diagnostics (Basel, Switzerland) Sep 2023This study aims to compare the effectiveness of using discrete heartbeats versus an entire 12-lead electrocardiogram (ECG) as the input for predicting future occurrences...
This study aims to compare the effectiveness of using discrete heartbeats versus an entire 12-lead electrocardiogram (ECG) as the input for predicting future occurrences of arrhythmia and atrial fibrillation using deep learning models. Experiments were conducted using two types of inputs: a combination of discrete heartbeats extracted from 12-lead ECG and an entire 12-lead ECG signal of 10 s. This study utilized 326,904 ECG signals from 134,447 patients and categorized them into three groups: true-normal sinus rhythm (T-NSR), atrial fibrillation-normal sinus rhythm (AF-NSR), and clinically important arrhythmia-normal sinus rhythm (CIA-NSR). The T-NSR group comprised patients with at least three normal rhythms in a year and no atrial fibrillation or arrhythmias history. Clinically important arrhythmia included atrial fibrillation, atrial flutter, atrial premature contraction, atrial tachycardia, ventricular premature contraction, ventricular tachycardia, right and left bundle branch block, and atrioventricular block over the second degree. The AF-NSR group included normal sinus rhythm paired with atrial fibrillation or atrial flutter within 14 days, and the CIA-NSR group comprised normal sinus rhythm paired with CIA occurring within 14 days. Three deep learning models, ResNet-18, LSTM, and Transformer-based models, were utilized to distinguish T-NSR from AF-NSR and T-NSR from CIA-NSR. The experiments demonstrated the potential of using discrete heartbeats in predicting future arrhythmia and atrial fibrillation incidences extracted from 12-lead electrocardiogram (ECG) signals alone, without any additional patient information. The analysis reveals that these discrete heartbeats contain subtle patterns that deep learning models can identify. Focusing on discrete heartbeats may lead to more timely and accurate diagnoses of these conditions, improving patient outcomes and enabling automated diagnosis using ECG signals as a biomarker.
PubMed: 37685387
DOI: 10.3390/diagnostics13172849