-
Genetics in Medicine : Official Journal... Jul 2022Noninvasive prenatal screening (NIPS) using cell-free DNA has been assimilated into prenatal care. Prior studies examined clinical validity and technical performance in... (Review)
Review
PURPOSE
Noninvasive prenatal screening (NIPS) using cell-free DNA has been assimilated into prenatal care. Prior studies examined clinical validity and technical performance in high-risk populations. This systematic evidence review evaluates NIPS performance in a general-risk population.
METHODS
Medline (PubMed) and Embase were used to identify studies examining detection of Down syndrome (T21), trisomy 18 (T18), trisomy 13 (T13), sex chromosome aneuploidies, rare autosomal trisomies, copy number variants, and maternal conditions, as well as studies assessing the psychological impact of NIPS and the rate of subsequent diagnostic testing. Random-effects meta-analyses were used to calculate pooled estimates of NIPS performance (P < .05). Heterogeneity was investigated through subgroup analyses. Risk of bias was assessed.
RESULTS
A total of 87 studies met inclusion criteria. Diagnostic odds ratios were significant (P < .0001) for T21, T18, and T13 for singleton and twin pregnancies. NIPS was accurate (≥99.78%) in detecting sex chromosome aneuploidies. Performance for rare autosomal trisomies and copy number variants was variable. Use of NIPS reduced diagnostic tests by 31% to 79%. Conclusions regarding psychosocial outcomes could not be drawn owing to lack of data. Identification of maternal conditions was rare.
CONCLUSION
NIPS is a highly accurate screening method for T21, T18, and T13 in both singleton and twin pregnancies.
Topics: Cell-Free Nucleic Acids; Down Syndrome; Female; Humans; Noninvasive Prenatal Testing; Pregnancy; Prenatal Diagnosis; Sex Chromosome Aberrations; Trisomy; Trisomy 13 Syndrome; Trisomy 18 Syndrome
PubMed: 35608568
DOI: 10.1016/j.gim.2022.03.019 -
BMC Pediatrics May 2018The use of technology to assist in the communication, socialization, language, and motor skills of children with Down's syndrome (DS) is required. The aim of this study...
BACKGROUND
The use of technology to assist in the communication, socialization, language, and motor skills of children with Down's syndrome (DS) is required. The aim of this study was to analyse research findings regarding the different instruments of 'augmentative and alternative communication' used in children with Down's syndrome.
METHODS
This is a systematic review of published articles available on PubMed, Web of Science, PsycInfo, and BVS using the following descriptors: assistive technology AND syndrome, assistive technology AND down syndrome, down syndrome AND augmentative and alternative communication. Studies published in English were selected if they met the following inclusion criteria: (1) study of children with a diagnosis of DS, and (2) assistive technology and/or augmentative and alternative communication analysis in this population.
RESULTS
A total of 1087 articles were identified. Thirteen articles met the inclusion criteria. The instruments most used by the studies were speech-generating devices (SGDs) and the Picture Exchange Communication System (PECS).
CONCLUSION
Twelve instruments that provided significant aid to the process of communication and socialization of children with DS were identified. These instruments increase the interaction between individuals among this population and their peers, contributing to their quality of life and self-esteem.
Topics: Child; Child Language; Communication Aids for Disabled; Down Syndrome; Humans; Motor Skills; Social Skills
PubMed: 29751828
DOI: 10.1186/s12887-018-1144-5 -
The Cochrane Database of Systematic... Sep 2017During pregnancy, fetal cells suitable for genetic testing can be obtained from amniotic fluid by amniocentesis (AC), placental tissue by chorionic villus sampling... (Review)
Review
BACKGROUND
During pregnancy, fetal cells suitable for genetic testing can be obtained from amniotic fluid by amniocentesis (AC), placental tissue by chorionic villus sampling (CVS), or fetal blood. A major disadvantage of second trimester amniocentesis is that the results are available relatively late in pregnancy (after 16 weeks' gestation). Earlier alternatives are chorionic villus sampling (CVS) and early amniocentesis, which can be performed in the first trimester of pregnancy.
OBJECTIVES
The objective of this review was to compare the safety and accuracy of all types of AC (i.e. early and late) and CVS (e.g. transabdominal, transcervical) for prenatal diagnosis.
SEARCH METHODS
We searched the Cochrane Pregnancy and Childbirth Group's Trials Register (3 March 2017), ClinicalTrials.gov, the WHO International Clinical Trials Registry Platform (ICTRP; 3 March 2017), and reference lists of retrieved studies.
SELECTION CRITERIA
All randomised trials comparing AC and CVS by either transabdominal or transcervical route.
DATA COLLECTION AND ANALYSIS
Two review authors independently assessed trials for inclusion and risk of bias, extracted data and checked them for accuracy. The quality of the evidence was assessed using the GRADE approach.
MAIN RESULTS
We included a total of 16 randomised studies, with a total of 33,555 women, 14 of which were deemed to be at low risk of bias. The number of women included in the trials ranged from 223 to 4606.Studies were categorized into six comparisons: 1. second trimester AC versus control; 2. early versus second trimester AC; 3. CVS versus second trimester AC; 4. CVS methods; 5. Early AC versus CVS; and 6. AC with or without ultrasound.One study compared second trimester AC with no AC (control) in a low risk population (women = 4606). Background pregnancy loss was around 2%. Second trimester AC compared to no testing increased total pregnancy loss by another 1%. The confidence intervals (CI) around this excess risk were relatively large (3.2% versus 2.3 %, average risk ratio (RR) 1.41, 95% CI 0.99 to 2.00; moderate-quality evidence). In the same study, spontaneous miscarriages were also higher (2.1% versus 1.3%; average RR 1.60, 95% CI 1.02 to 2.52; high-quality evidence). The number of congenital anomalies was similar in both groups (2.0% versus 2.2%, average RR 0.93, 95% CI 0.62 to 1.39; moderate-quality evidence).One study (women = 4334) found that early amniocentesis was not a safe early alternative compared to second trimester amniocentesis because of increased total pregnancy losses (7.6% versus 5.9%; average RR 1.29, 95% CI 1.03 to 1.61; high-quality evidence), spontaneous miscarriages (3.6% versus 2.5%, average RR 1.41, 95% CI 1.00 to 1.98; moderate-quality evidence), and a higher incidence of congential anomalies, including talipes (4.7% versus 2.7%; average RR 1.73, 95% CI 1.26 to 2.38; high-quality evidence).When pregnancy loss after CVS was compared with second trimester AC, there was a clinically significant heterogeneity in the size and direction of the effect depending on the technique used (transabdominal or transcervical), therefore, the results were not pooled. Only one study compared transabdominal CVS with second trimester AC (women = 2234). They found no clear difference between the two procedures in the total pregnancy loss (6.3% versus 7%; average RR 0.90, 95% CI 0.66 to 1.23, low-quality evidence), spontaneous miscarriages (3.0% versus 3.9%; average RR 0.77, 95% CI 0.49 to 1.21; low-quality evidence), and perinatal deaths (0.7% versus 0.6%; average RR 1.18, 95% CI 0.40 to 3.51; low-quality evidence). Transcervical CVS may carry a higher risk of pregnancy loss (14.5% versus 11.5%; average RR 1.40, 95% CI 1.09 to 1.81), but the results were quite heterogeneous.Five studies compared transabdominal and transcervical CVS (women = 7978). There were no clear differences between the two methods in pregnancy losses (average RR 1.16, 95% CI 0.81 to 1.65; very low-quality evidence), spontaneous miscarriages (average RR 1.68, 95% CI 0.79 to 3.58; very low-quality evidence), or anomalies (average RR 0.68, 95% CI 0.41 to 1.12; low-quality evidence). We downgraded the quality of the evidence to low due to heterogeneity between studies. Transcervical CVS may be more technically demanding than transabdominal CVS, with more failures to obtain sample (2.0% versus 1.1%; average RR 1.79, 95% CI 1.13 to 2.82, moderate-quality evidence).Overall, we found low-quality evidence for outcomes when early amniocentesis was compared to transabdominal CVS. Spontaneous miscarriage was the only outcome supported by moderate-quality evidence, resulting in more miscarriages after early AC compared with transabdominal CVS (2.3% versus 1.3%; average RR 1.73, 95% CI 1.15 to 2.60). There were no clear differences in pregnancy losses (average RR 1.15, 95% CI 0.86 to 1.54; low-quality evidence), or anomalies (average RR 1.14, 95% CI 0.57 to 2.30; very low-quality evidence).We found one study that examined AC with or without ultrasound, which evaluated a type of ultrasound-assisted procedure that is now considered obsolete.
AUTHORS' CONCLUSIONS
Second trimester amniocentesis increased the risk of pregnancy loss, but it was not possible to quantify this increase precisely from only one study, carried out more than 30 years ago.Early amniocentesis was not as safe as second trimester amniocentesis, illustrated by increased pregnancy loss and congenital anomalies (talipes). Transcervical chorionic villus sampling compared with second trimester amniocentesis may be associated with a higher risk of pregnancy loss, but results were quite heterogeneous.Diagnostic accuracy of different methods could not be assessed adequately because of incomplete karyotype data in most studies.
Topics: Amniocentesis; Chorionic Villi Sampling; Congenital Abnormalities; Female; Humans; Pregnancy; Pregnancy Trimester, First; Pregnancy Trimester, Second; Randomized Controlled Trials as Topic
PubMed: 28869276
DOI: 10.1002/14651858.CD003252.pub2 -
Fertility and Sterility Oct 2021To quantify the efficacy of medical management of uterine arteriovenous malformation (AVM) and compare efficacy between different classes of medication. In addition, we... (Comparative Study)
Comparative Study Meta-Analysis
OBJECTIVE
To quantify the efficacy of medical management of uterine arteriovenous malformation (AVM) and compare efficacy between different classes of medication. In addition, we evaluated for factors associated with treatment success and pregnancy outcomes after medical management.
DESIGN
Systematic review and meta-analysis.
SETTING
Not applicable.
PATIENT(S)
Thirty-two studies representing 121 premenopausal women with medically-treated uterine AVM were identified via database searches of MEDLINE, Embase, Web of Science, and cited references.
INTERVENTION(S)
Medical treatment with progestins, gonadotropin-releasing hormone agonists (GnRH-a), methotrexate, combined hormonal contraception , uterotonics, danazol, or combination of the above.
MAIN OUTCOME MEASURE(S)
Primary outcome of treatment success was defined as AVM resolution without subsequent procedural interventions. Secondary outcome was treatment complication (readmission or transfusion).
RESULT(S)
The overall success rate of medical management was 88% (106/121). After adjusting for clustering effects, success rates for progestin (82.5%; 95% confidence interval [CI], 70.1%-90.4%), GnRH-a (89.3%; 99% CI, 71.4%-96.5%) and methotrexate (90.0%; 99% CI, 55.8%-98.8%) were significantly different from the null hypothesis of 50% success. The agents with the lowest adjusted proportion of complications were progestins (10.0%; 99% CI, 3.3%-26.8%) and GnRH-a (10.7%; 99% CI, 3.5%-28.4%). No clinical factors were found to predict treatment success. Twenty-six subsequent pregnancies are described, with no reported recurrences of AVM.
CONCLUSION(S)
Medical management for uterine AVM is a reasonable approach in a well selected patient. These data should be interpreted in the context of significant publication bias.
Topics: Arteriovenous Fistula; Blood Transfusion; Clinical Decision-Making; Female; Humans; Patient Readmission; Patient Selection; Pregnancy; Pregnancy Rate; Risk Assessment; Risk Factors; Treatment Outcome; Uterine Artery; Uterus
PubMed: 34130801
DOI: 10.1016/j.fertnstert.2021.05.095 -
BMC Medicine May 2017Pregnant women with epilepsy frequently experience seizures related to pregnancy complications and are often prescribed anti-epileptic drugs (AEDs) to manage their... (Comparative Study)
Comparative Study Meta-Analysis
BACKGROUND
Pregnant women with epilepsy frequently experience seizures related to pregnancy complications and are often prescribed anti-epileptic drugs (AEDs) to manage their symptoms. However, less is known about the comparative safety of AED exposure in utero. We aimed to compare the risk of congenital malformations (CMs) and prenatal outcomes of AEDs in infants/children who were exposed to AEDs in utero through a systematic review and Bayesian random-effects network meta-analysis.
METHODS
MEDLINE, EMBASE, and Cochrane CENTRAL were searched from inception to December 15, 2015. Two reviewers independently screened titles/abstracts and full-text papers for experimental and observational studies comparing mono- or poly-therapy AEDs versus control (no AED exposure) or other AEDs, then abstracted data and appraised the risk of bias. The primary outcome was incidence of major CMs, overall and by specific type (cardiac malformations, hypospadias, cleft lip and/or palate, club foot, inguinal hernia, and undescended testes).
RESULTS
After screening 5305 titles and abstracts, 642 potentially relevant full-text articles, and 17 studies from scanning reference lists, 96 studies were eligible (n = 58,461 patients). Across all major CMs, many AEDs were associated with higher risk compared to control. For major CMs, ethosuximide (OR, 3.04; 95% CrI, 1.23-7.07), valproate (OR, 2.93; 95% CrI, 2.36-3.69), topiramate (OR, 1.90; 95% CrI, 1.17-2.97), phenobarbital (OR, 1.83; 95% CrI, 1.35-2.47), phenytoin (OR, 1.67; 95% CrI, 1.30-2.17), carbamazepine (OR, 1.37; 95% CrI, 1.10-1.71), and 11 polytherapies were significantly more harmful than control, but lamotrigine (OR, 0.96; 95% CrI, 0.72-1.25) and levetiracetam (OR, 0.72; 95% CrI, 0.43-1.16) were not.
CONCLUSION
The newer generation AEDs, lamotrigine and levetiracetam, were not associated with significant increased risks of CMs compared to control, and were significantly less likely to be associated with children experiencing cardiac malformations than control. However, this does not mean that these agents are not harmful to infants/children exposed in utero. Counselling is advised concerning teratogenic risks when the prescription is written for a woman of childbearing age and before women continue with these agents when considering pregnancy, such as switching from polytherapy to monotherapy with evidence of lower risk and avoiding AEDs, such as valproate, that are consistently associated with CMs. These decisions must be balanced against the need for seizure control.
SYSTEMATIC REVIEW REGISTRATION
PROSPERO CRD42014008925.
Topics: Abnormalities, Drug-Induced; Adult; Anticonvulsants; Bayes Theorem; Child; Epilepsy; Female; Humans; Infant; Network Meta-Analysis; Pregnancy; Pregnancy Complications; Pregnancy Outcome; Young Adult
PubMed: 28472982
DOI: 10.1186/s12916-017-0845-1 -
BMC Pregnancy and Childbirth Dec 2018Gestational diabetes mellitus (GDM) is a of the major public health issues in Asia. The present study aimed to determine the prevalence of, and risk factors for GDM in...
BACKGROUND
Gestational diabetes mellitus (GDM) is a of the major public health issues in Asia. The present study aimed to determine the prevalence of, and risk factors for GDM in Asia via a systematic review and meta-analysis.
METHODS
We systematically searched PubMed, Ovid, Scopus and ScienceDirect for observational studies in Asia from inception to August 2017. We selected cross sectional studies reporting the prevalence and risk factors for GDM. A random effects model was used to estimate the pooled prevalence of GDM and odds ratio (OR) with 95% confidence interval (CI).
RESULTS
Eighty-four studies with STROBE score ≥ 14 were included in our analysis. The pooled prevalence of GDM in Asia was 11.5% (95% CI 10.9-12.1). There was considerable heterogeneity (I > 95%) in the prevalence of GDM in Asia, which is likely due to differences in diagnostic criteria, screening methods and study setting. Meta-analysis demonstrated that the risk factors of GDM include history of previous GDM (OR 8.42, 95% CI 5.35-13.23); macrosomia (OR 4.41, 95% CI 3.09-6.31); and congenital anomalies (OR 4.25, 95% CI 1.52-11.88). Other risk factors include a BMI ≥25 kg/m (OR 3.27, 95% CI 2.81-3.80); pregnancy-induced hypertension (OR 3.20, 95% CI 2.19-4.68); family history of diabetes (OR 2.77, 2.22-3.47); history of stillbirth (OR 2.39, 95% CI 1.68-3.40); polycystic ovary syndrome (OR 2.33, 95% CI1.72-3.17); history of abortion (OR 2.25, 95% CI 1.54-3.29); age ≥ 25 (OR 2.17, 95% CI 1.96-2.41); multiparity ≥2 (OR 1.37, 95% CI 1.24-1.52); and history of preterm delivery (OR 1.93, 95% CI 1.21-3.07).
CONCLUSION
We found a high prevalence of GDM among the Asian population. Asian women with common risk factors especially among those with history of previous GDM, congenital anomalies or macrosomia should receive additional attention from physician as high-risk cases for GDM in pregnancy.
TRIAL REGISTRATION
PROSPERO (2017: CRD42017070104 ).
Topics: Asia; Congenital Abnormalities; Diabetes, Gestational; Female; Humans; Pregnancy; Prevalence; Risk Factors
PubMed: 30547769
DOI: 10.1186/s12884-018-2131-4 -
The American Journal of Psychiatry Jan 2020Uncertainty surrounds the risks of lithium use during pregnancy in women with bipolar disorder. The authors sought to provide a critical appraisal of the evidence... (Meta-Analysis)
Meta-Analysis
OBJECTIVE
Uncertainty surrounds the risks of lithium use during pregnancy in women with bipolar disorder. The authors sought to provide a critical appraisal of the evidence related to the efficacy and safety of lithium treatment during the peripartum period, focusing on women with bipolar disorder and their offspring.
METHODS
The authors conducted a systematic review and random-effects meta-analysis assessing case-control, cohort, and interventional studies reporting on the safety (primary outcome, any congenital anomaly) or efficacy (primary outcome, mood relapse prevention) of lithium treatment during pregnancy and the postpartum period. The Newcastle-Ottawa Scale and the Cochrane risk of bias tools were used to assess the quality of available PubMed and Scopus records through October 2018.
RESULTS
Twenty-nine studies were included in the analyses (20 studies were of good quality, and six were of poor quality; one study had an unclear risk of bias, and two had a high risk of bias). Thirteen of the 29 studies could be included in the quantitative analysis. Lithium prescribed during pregnancy was associated with higher odds of any congenital anomaly (N=23,300, k=11; prevalence=4.1%, k=11; odds ratio=1.81, 95% CI=1.35-2.41; number needed to harm (NNH)=33, 95% CI=22-77) and of cardiac anomalies (N=1,348,475, k=12; prevalence=1.2%, k=9; odds ratio=1.86, 95% CI=1.16-2.96; NNH=71, 95% CI=48-167). Lithium exposure during the first trimester was associated with higher odds of spontaneous abortion (N=1,289, k=3, prevalence=8.1%; odds ratio=3.77, 95% CI=1.15-12.39; NNH=15, 95% CI=8-111). Comparing lithium-exposed with unexposed pregnancies, significance remained for any malformation (exposure during any pregnancy period or the first trimester) and cardiac malformations (exposure during the first trimester), but not for spontaneous abortion (exposure during the first trimester) and cardiac malformations (exposure during any pregnancy period). Lithium was more effective than no lithium in preventing postpartum relapse (N=48, k=2; odds ratio=0.16, 95% CI=0.03-0.89; number needed to treat=3, 95% CI=1-12). The qualitative synthesis showed that mothers with serum lithium levels <0.64 mEq/L and dosages <600 mg/day had more reactive newborns without an increased risk of cardiac malformations.
CONCLUSIONS
The risk associated with lithium exposure at any time during pregnancy is low, and the risk is higher for first-trimester or higher-dosage exposure. Ideally, pregnancy should be planned during remission from bipolar disorder and lithium prescribed within the lowest therapeutic range throughout pregnancy, particularly during the first trimester and the days immediately preceding delivery, balancing the safety and efficacy profile for the individual patient.
Topics: Abnormalities, Drug-Induced; Abortion, Spontaneous; Bipolar Disorder; Female; Humans; Lithium Compounds; Postpartum Period; Pregnancy; Treatment Outcome
PubMed: 31623458
DOI: 10.1176/appi.ajp.2019.19030228 -
Ultrasound in Obstetrics & Gynecology :... Jan 2022To determine the diagnostic accuracy of ultrasound at 11-14 weeks' gestation in the detection of fetal cardiac abnormalities and to evaluate factors that impact the... (Meta-Analysis)
Meta-Analysis
OBJECTIVES
To determine the diagnostic accuracy of ultrasound at 11-14 weeks' gestation in the detection of fetal cardiac abnormalities and to evaluate factors that impact the detection rate.
METHODS
This was a systematic review of studies evaluating the diagnostic accuracy of ultrasound in the detection of fetal cardiac anomalies at 11-14 weeks' gestation, performed by two independent reviewers. An electronic search of four databases (MEDLINE, EMBASE, Web of Science Core Collection and The Cochrane Library) was conducted for studies published between January 1998 and July 2020. Prospective and retrospective studies evaluating pregnancies at any prior level of risk and in any healthcare setting were eligible for inclusion. The reference standard used was the detection of a cardiac abnormality on postnatal or postmortem examination. Data were extracted from the included studies to populate 2 × 2 tables. Meta-analysis was performed using a random-effects model in order to determine the performance of first-trimester ultrasound in the detection of major cardiac abnormalities overall and of individual types of cardiac abnormality. Data were analyzed separately for high-risk and non-high-risk populations. Preplanned secondary analyses were conducted in order to assess factors that may impact screening performance, including the imaging protocol used for cardiac assessment (including the use of color-flow Doppler), ultrasound modality, year of publication and the index of sonographer suspicion at the time of the scan. Risk of bias and quality assessment were undertaken for all included studies using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool.
RESULTS
The electronic search yielded 4108 citations. Following review of titles and abstracts, 223 publications underwent full-text review, of which 63 studies, reporting on 328 262 fetuses, were selected for inclusion in the meta-analysis. In the non-high-risk population (45 studies, 306 872 fetuses), 1445 major cardiac anomalies were identified (prevalence, 0.41% (95% CI, 0.39-0.43%)). Of these, 767 were detected on first-trimester ultrasound examination of the heart and 678 were not detected. First-trimester ultrasound had a pooled sensitivity of 55.80% (95% CI, 45.87-65.50%), specificity of 99.98% (95% CI, 99.97-99.99%) and positive predictive value of 94.85% (95% CI, 91.63-97.32%) in the non-high-risk population. The cases diagnosed in the first trimester represented 63.67% (95% CI, 54.35-72.49%) of all antenatally diagnosed major cardiac abnormalities in the non-high-risk population. In the high-risk population (18 studies, 21 390 fetuses), 480 major cardiac anomalies were identified (prevalence, 1.36% (95% CI, 1.20-1.52%)). Of these, 338 were detected on first-trimester ultrasound examination and 142 were not detected. First-trimester ultrasound had a pooled sensitivity of 67.74% (95% CI, 55.25-79.06%), specificity of 99.75% (95% CI, 99.47-99.92%) and positive predictive value of 94.22% (95% CI, 90.22-97.22%) in the high-risk population. The cases diagnosed in the first trimester represented 79.86% (95% CI, 69.89-88.25%) of all antenatally diagnosed major cardiac abnormalities in the high-risk population. The imaging protocol used for examination was found to have an important impact on screening performance in both populations (P < 0.0001), with a significantly higher detection rate observed in studies using at least one outflow-tract view or color-flow Doppler imaging (both P < 0.0001). Different types of cardiac anomaly were not equally amenable to detection on first-trimester ultrasound.
CONCLUSIONS
First-trimester ultrasound examination of the fetal heart allows identification of over half of fetuses affected by major cardiac pathology. Future first-trimester screening programs should follow structured anatomical assessment protocols and consider the introduction of outflow-tract views and color-flow Doppler imaging, as this would improve detection rates of fetal cardiac pathology. © 2021 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.
Topics: Female; Fetal Diseases; Fetal Heart; Gestational Age; Heart Defects, Congenital; Humans; Predictive Value of Tests; Pregnancy; Pregnancy Trimester, First; Prospective Studies; Retrospective Studies; Ultrasonography, Prenatal
PubMed: 34369613
DOI: 10.1002/uog.23740 -
JAMA Network Open Aug 2022Universal ultrasonographic screening for developmental dysplasia of the hip (DDH) has gained increasing popularity despite the lack of benefit in terms of reducing the... (Meta-Analysis)
Meta-Analysis
IMPORTANCE
Universal ultrasonographic screening for developmental dysplasia of the hip (DDH) has gained increasing popularity despite the lack of benefit in terms of reducing the rates of late-detected cases (age ≥12 weeks) in randomized clinical trials.
OBJECTIVE
To report the reported incidence of DDH in the English scientific literature and compare rates of late-detected cases in settings with different DDH screening strategies.
DATA SOURCES
PubMed, Scopus, and Web of Science databases were searched on November 25 and 27, 2021. No time filters were used in the search.
STUDY SELECTION
All observational studies reporting the incidence of early-detected or late-detected (age ≥12 weeks) DDH were included. Non-English reports were excluded if the abstract did not include enough information to be included for analysis.
DATA EXTRACTION AND SYNTHESIS
The number of newborns screened and the detection rates were extracted. Meta-analysis calculated the pooled incidence of DDH per 1000 newborns with 95% CIs using a random- or fixed-effects model. This study is reported according to the PRISMA and MOOSE guidelines.
MAIN OUTCOMES AND MEASURES
The main outcome measures were early detection, early treatment, late detection, and operative treatment incidences.
RESULTS
A total of 1899 studies were identified, 203 full texts were assessed, and 76 studies with 16 901 079 infants were included in final analyses. The early detection rate was 8.4 (95% CI, 4.8-14.8) infants with DDH per 1000 newborns with clinical screening, 4.4 (95% CI, 2.4-8.0) infants with DDH per 1000 newborns with selective ultrasonographic screening, and 23.0 (95% CI, 15.7-33.4) infants with DDH per 1000 newborns with universal ultrasonographic screening. Rates for nonoperative treatment were 5.5 (95% CI, 2.1-14) treatments per 1000 newborns with clinical screening, 3.1 (95% CI, 2.0-4.8) treatments per 1000 newborns with selective ultrasonographic screening, and 9.8 (95% CI, 6.7-14.4) treatments per 1000 newborns with universal ultrasonographic screening. The incidence of late-detected DDH was 0.5 (95% CI, 0.2-1.5) infants with DDH per 1000 newborns with clinical screening, 0.6 (95% CI, 0.3-1.3) infants with DDH per 1000 newborns with selective ultrasonographic screening, and 0.2 (95% CI, 0.0-0.8) infants with DDH per 1000 newborns with universal ultrasonographic screening. The corresponding incidences of operative treatment were 0.2 (95% CI, 0.0-0.9) operations per 1000 newborns with clinical screening, 0.5 (95% CI, 0.4-0.7) operations per 1000 newborns with selective ultrasonographic screening, and 0.4 (95% CI, 0.2-0.7) operations per 1000 newborns with universal ultrasonographic screening.
CONCLUSIONS AND RELEVANCE
This meta-analysis found that early detection rates and nonoperative treatments were higher with universal screening. The late detection and operative treatment rates with universal screening were similar to those among selectively and clinically screened newborns. Based on these results, universal screening may cause initial overtreatment without reducing the rates of late detection and operative treatment.
Topics: Developmental Dysplasia of the Hip; Hip Dislocation, Congenital; Humans; Incidence; Infant; Infant, Newborn; Neonatal Screening; Ultrasonography
PubMed: 35980635
DOI: 10.1001/jamanetworkopen.2022.27638 -
The Cochrane Database of Systematic... Nov 2016There is evidence that certain antiepileptic drugs (AEDs) are teratogenic and are associated with an increased risk of congenital malformation. The majority of women... (Meta-Analysis)
Meta-Analysis Review
BACKGROUND
There is evidence that certain antiepileptic drugs (AEDs) are teratogenic and are associated with an increased risk of congenital malformation. The majority of women with epilepsy continue taking AEDs throughout pregnancy; therefore it is important that comprehensive information on the potential risks associated with AED treatment is available.
OBJECTIVES
To assess the effects of prenatal exposure to AEDs on the prevalence of congenital malformations in the child.
SEARCH METHODS
We searched the Cochrane Epilepsy Group Specialized Register (September 2015), Cochrane Central Register of Controlled Trials (CENTRAL) (2015, Issue 11), MEDLINE (via Ovid) (1946 to September 2015), EMBASE (1974 to September 2015), Pharmline (1978 to September 2015), Reprotox (1983 to September 2015) and conference abstracts (2010-2015) without language restriction.
SELECTION CRITERIA
We included prospective cohort controlled studies, cohort studies set within pregnancy registries and randomised controlled trials. Participants were women with epilepsy taking AEDs; the two control groups were women without epilepsy and women with epilepsy who were not taking AEDs during pregnancy.
DATA COLLECTION AND ANALYSIS
Three authors independently selected studies for inclusion. Five authors completed data extraction and risk of bias assessments. The primary outcome was the presence of a major congenital malformation. Secondary outcomes included specific types of major congenital malformations. Where meta-analysis was not possible, we reviewed included studies narratively.
MAIN RESULTS
We included 50 studies, with 31 contributing to meta-analysis. Study quality varied, and given the observational design, all were at high risk of certain biases. However, biases were balanced across the AEDs investigated and we believe that the results are not explained by these biases.Children exposed to carbamazepine (CBZ) were at a higher risk of malformation than children born to women without epilepsy (N = 1367 vs 2146, risk ratio (RR) 2.01, 95% confidence interval (CI) 1.20 to 3.36) and women with untreated epilepsy (N = 3058 vs 1287, RR 1.50, 95% CI 1.03 to 2.19). Children exposed to phenobarbital (PB) were at a higher risk of malformation than children born to women without epilepsy (N = 345 vs 1591, RR 2.84, 95% CI 1.57 to 5.13). Children exposed to phenytoin (PHT) were at an increased risk of malformation compared with children born to women without epilepsy (N = 477 vs 987, RR 2.38, 95% CI 1.12 to 5.03) and to women with untreated epilepsy (N = 640 vs 1256, RR 2.40, 95% CI 1.42 to 4.08). Children exposed to topiramate (TPM) were at an increased risk of malformation compared with children born to women without epilepsy (N = 359 vs 442, RR 3.69, 95% CI 1.36 to 10.07). The children exposed to valproate (VPA) were at a higher risk of malformation compared with children born to women without epilepsy (N = 467 vs 1936, RR 5.69, 95% CI 3.33 to 9.73) and to women with untreated epilepsy (N = 1923 vs 1259, RR 3.13, 95% CI 2.16 to 4.54). There was no increased risk for major malformation for lamotrigine (LTG). Gabapentin (GBP), levetiracetam (LEV), oxcarbazepine (OXC), primidone (PRM) or zonisamide (ZNS) were not associated with an increased risk, however, there were substantially fewer data for these medications.For AED comparisons, children exposed to VPA had the greatest risk of malformation (10.93%, 95% CI 8.91 to 13.13). Children exposed to VPA were at an increased risk of malformation compared with children exposed to CBZ (N = 2529 vs 4549, RR 2.44, 95% CI 2.00 to 2.94), GBP (N = 1814 vs 190, RR 6.21, 95% CI 1.91 to 20.23), LEV (N = 1814 vs 817, RR 5.82, 95% CI 3.13 to 10.81), LTG (N = 2021 vs 4164, RR 3.56, 95% CI 2.77 to 4.58), TPM (N = 1814 vs 473, RR 2.35, 95% CI 1.40 to 3.95), OXC (N = 676 vs 238, RR 3.71, 95% CI 1.65 to 8.33), PB (N = 1137 vs 626, RR 1.59, 95% CI 1.11 to 2.29, PHT (N = 2319 vs 1137, RR 2.00, 95% CI 1.48 to 2.71) or ZNS (N = 323 vs 90, RR 17.13, 95% CI 1.06 to 277.48). Children exposed to CBZ were at a higher risk of malformation than those exposed to LEV (N = 3051 vs 817, RR 1.84, 95% CI 1.03 to 3.29) and children exposed to LTG (N = 3385 vs 4164, RR 1.34, 95% CI 1.01 to 1.76). Children exposed to PB were at a higher risk of malformation compared with children exposed to GBP (N = 204 vs 159, RR 8.33, 95% CI 1.04 to 50.00), LEV (N = 204 vs 513, RR 2.33, 95% CI 1.04 to 5.00) or LTG (N = 282 vs 1959, RR 3.13, 95% CI 1.64 to 5.88). Children exposed to PHT had a higher risk of malformation than children exposed to LTG (N = 624 vs 4082, RR 1.89, 95% CI 1.19 to 2.94) or to LEV (N = 566 vs 817, RR 2.04, 95% CI 1.09 to 3.85); however, the comparison to LEV was not significant in the random-effects model. Children exposed to TPM were at a higher risk of malformation than children exposed to LEV (N = 473 vs 817, RR 2.00, 95% CI 1.03 to 3.85) or LTG (N = 473 vs 3975, RR 1.79, 95% CI 1.06 to 2.94). There were no other significant differences, or comparisons were limited to a single study.We found significantly higher rates of specific malformations associating PB exposure with cardiac malformations and VPA exposure with neural tube, cardiac, oro-facial/craniofacial, and skeletal and limb malformations in comparison to other AEDs. Dose of exposure mediated the risk of malformation following VPA exposure; a potential dose-response association for the other AEDs remained less clear.
AUTHORS' CONCLUSIONS
Exposure in the womb to certain AEDs carried an increased risk of malformation in the foetus and may be associated with specific patterns of malformation. Based on current evidence, LEV and LTG exposure carried the lowest risk of overall malformation; however, data pertaining to specific malformations are lacking. Physicians should discuss both the risks and treatment efficacy with the patient prior to commencing treatment.
Topics: Abnormalities, Drug-Induced; Anticonvulsants; Cardiovascular Abnormalities; Craniofacial Abnormalities; Epilepsy; Female; Humans; Infant, Newborn; Musculoskeletal Abnormalities; Neural Tube Defects; Pregnancy; Pregnancy Complications
PubMed: 27819746
DOI: 10.1002/14651858.CD010224.pub2