American Journal of Infection Control Sep 2023Hospital-acquired infections (HAIs) are a significant clinical and economic burden on health systems worldwide. Copper alloys have been certified by the US EPA as solid... (Review)
Review
INTRODUCTION
Hospital-acquired infections (HAIs) are a significant clinical and economic burden on health systems worldwide. Copper alloys have been certified by the US EPA as solid antimicrobial materials, but their effectiveness in reducing HAIs is not well established OBJECTIVES: This systematic review aimed to assess copper surfaces in situ efficacy in reducing health care's microbial burden compared to control surfaces.
MATERIALS AND METHODS
A literature search was conducted using three electronic databases: Web of Science, PubMed, and Scopus, with the keywords "copper" and "surfaces" and "antimicrobial" and "antibacterial" and "infections." Studies from 2010 to 2022 were included. The quality of the studies was independently screened and assessed using the Newcastle Ottawa Scale.
RESULTS
A total of 56 articles were screened, with 8 included in the review and 7, added from references. Two third of the studies report a significant reduction in the microbial burden on copper objects compared to control objects. The 2 studies with the highest scores on NOS evaluation indicated that using copper or copper alloys in healthcare settings can effectively decrease the number of bacterial contaminations on touch surfaces.
CONCLUSIONS
The results suggest the potential effectiveness of copper as a preventive tool in healthcare facilities, but further studies and longer trials are needed to establish a relationship between copper and reduced nosocomial infections.
Topics: Humans; Copper; Anti-Infective Agents; Health Facilities; Cross Infection; Alloys; Delivery of Health Care
PubMed: 36842712
DOI: 10.1016/j.ajic.2023.02.010 -
Clinical Oral Implants Research Sep 2009The objective of this systematic review was to assess the 5-year survival rates and incidences of complications associated with ceramic abutments and to compare them... (Comparative Study)
Comparative Study Review
OBJECTIVES
The objective of this systematic review was to assess the 5-year survival rates and incidences of complications associated with ceramic abutments and to compare them with those of metal abutments.
METHODS
An electronic Medline search complemented by manual searching was conducted to identify randomized-controlled clinical trials, and prospective and retrospective studies providing information on ceramic and metal abutments with a mean follow-up time of at least 3 years. Patients had to have been examined clinically at the follow-up visit. Assessment of the identified studies and data abstraction was performed independently by three reviewers. Failure rates were analyzed using standard and random-effects Poisson regression models to obtain summary estimates of 5-year survival proportions.
RESULTS
Twenty-nine clinical and 22 laboratory studies were selected from an initial yield of 7136 titles and data were extracted. The estimated 5-year survival rate of ceramic abutments was 99.1% [95% confidence interval (CI): 93.8-99.9%] and 97.4% (95% CI: 96-98.3%) for metal abutments. The estimated cumulative incidence of technical complications after 5 years was 6.9% (95% CI: 3.5-13.4%) for ceramic abutments and 15.9% (95% CI: 11.6-21.5%) for metal abutments. Abutment screw loosening was the most frequent technical problem, occurring at an estimated cumulative incidence after 5 years of 5.1% (95% CI: 3.3-7.7%). All-ceramic crowns supported by ceramic abutments exhibited similar annual fracture rates as metal-ceramic crowns supported by metal abutments. The cumulative incidence of biological complications after 5 years was estimated at 5.2% (95% CI: 0.4-52%) for ceramic and 7.7% (95% CI: 4.7-12.5%) for metal abutments. Esthetic complications tended to be more frequent at metal abutments. A meta-analysis of the laboratory data was impossible due to the non-standardized test methods of the studies included.
CONCLUSION
The 5-year survival rates estimated from annual failure rates appeared to be similar for ceramic and metal abutments. The information included in this review did not provide evidence for differences of the technical and biological outcomes of ceramic and metal abutments. However, the information for ceramic abutments was limited in the number of studies and abutments analyzed as well as the accrued follow-up time. Standardized methods for the analysis of abutment strength are needed.
Topics: Alveolar Bone Loss; Animals; Crowns; Dental Abutments; Dental Porcelain; Dental Prosthesis, Implant-Supported; Dental Restoration Failure; Dental Stress Analysis; Denture, Partial, Fixed; Gingival Recession; Gold Alloys; Humans; Survival Analysis; Titanium
PubMed: 19663946
DOI: 10.1111/j.1600-0501.2009.01787.x -
3D Printing and Additive Manufacturing Dec 2021Until recently, three-dimensional (3D) printing/additive manufacturing has not been used extensively to create medical devices intended for actual clinical use,... (Review)
Review
Until recently, three-dimensional (3D) printing/additive manufacturing has not been used extensively to create medical devices intended for actual clinical use, primarily on patient safety and regulatory grounds. However, in recent years there have been advances in materials, printers, and experience, leading to increased clinical use. The aim of this study was to perform a structured systematic review of 3D-printed medical devices used directly in patient treatment. A search of 13 databases was performed to identify studies of 3D-printed medical devices, detailing fabrication technology and materials employed, clinical application, and clinical outcome. One hundred and ten papers describing one hundred and forty medical devices were identified and analyzed. A considerable increase was identified in the use of 3D printing to produce medical devices directly for clinical use in the past 3 years. This is dominated by printing of patient-specific implants and surgical guides for use in orthopedics and orthopedic oncology, but there is a trend of increased use across other clinical specialties. The prevailing material/3D-printing technology used were titanium alloy/electron beam melting for implants, and polyamide/selective laser sintering or polylactic acid/fused deposition modeling for surgical guides and instruments. A detailed analysis across medical applications by technology and materials is provided, as well as a commentary regarding regulatory aspects. In general, there is growing familiarity with, and acceptance of, 3D printing in clinical use.
PubMed: 36655011
DOI: 10.1089/3dp.2020.0324 -
Acta Bio-medica : Atenei Parmensis Jul 2021Magnesium (Mg) is a metal physiologically present in bone tissue and essential for bone health. Mg-based-alloys exhibit mechanical properties, namely density and...
BACKGROUND AND AIM OF THE WORK
Magnesium (Mg) is a metal physiologically present in bone tissue and essential for bone health. Mg-based-alloys exhibit mechanical properties, namely density and strength, similar to human cortical bone. These features have been exploited for the development of osteosynthesis devices in biodegradable Mg-based-alloys. Accordingly, the aim of this study was to rank the effectiveness and safety of Mg-based alloys applied in bone surgery in comparison to other suitable metals, focusing in particular on Mg superior biocompatibility and biodegradability.
METHODS
a systematic-review of the literature was conducted including only primary research studies dealing with patients suffering from fractured or osteotomized bones fixed using Mg-based osteosynthesis-devices.
RESULTS
literature revision suggested Mg-alloys holding comparable properties and side effects in comparison with titanium (Ti) screws, thus showing similar efficacy and safety. In particular, the gas formation in the carpal bones was identified as the main side effect of the Mg-alloys, during the corrosion/degradation phase of Mg.
CONCLUSIONS
according to the considered literature, the main advantages exploiting Mg-alloys for bone implants are related to their biocompatibility, bio-absorbability/-degradability, the lack of surgical removal, osteoconductivity and antibacterial activity. On the opposite, the main limitation of Mg-alloys is due to the poor mechanical resistance of small devices for internal fixation of bone fragments that lack of sufficient strength to withstand high forces. Therefore, an important future prospect could rely in the development of innovative hybrid systems aimed at fixing high load-bearing fractures, as well as in regenerative-medicine by developing new Mg-based engineered scaffolds.
Topics: Absorbable Implants; Alloys; Corrosion; Humans; Magnesium; Titanium
PubMed: 34313658
DOI: 10.23750/abm.v92iS3.11757 -
The Angle Orthodontist Jan 2010To evaluate the quantitative effects on torque expression of varying the slot size of stainless steel orthodontic brackets and the dimension of stainless steel wire, and... (Review)
Review
OBJECTIVE
To evaluate the quantitative effects on torque expression of varying the slot size of stainless steel orthodontic brackets and the dimension of stainless steel wire, and to analyze the limitations of the experimental methods used.
MATERIALS AND METHODS
In vitro studies measuring torque expression in conventional and self-ligating stainless steel brackets with a torque-measuring device, with the use of straight stainless steel orthodontic wire without second-order mechanics and without loops, coils, or auxiliary wires, were sought through a systematic review process.
RESULTS
Eleven articles were selected. Direct comparison of different studies was limited by differences in the measuring devices used and in the parameters measured. On the basis of the selected studies, in a 0.018 inch stainless steel bracket slot, the engagement angle ranges from 31 degrees with a 0.016 x 0.016 inch stainless steel archwire to 4.6 degrees with a 0.018 x 0.025 inch stainless steel archwire. In a 0.022 inch stainless steel bracket slot, the engagement angle ranges from 18 degrees with a 0.018 x 0.025 inch stainless steel archwire to 6 degrees with a 0.021 x 0.025 inch stainless steel archwire. Active stainless steel self-ligating brackets demonstrate an engagement angle of approximately 7.5 degrees, whereas passive stainless steel self-ligating brackets show an engagement angle of approximately 14 degrees with 0.019 x 0.025 inch stainless steel wire in a 0.022 inch slot.
CONCLUSIONS
The engagement angle depends on archwire dimension and edge shape, as well as on bracket slot dimension, and is variable and larger than published theoretical values. Clinically effective torque can be achieved in a 0.022 inch bracket slot with archwire torsion of 15 to 31 degrees for active self-ligating brackets and of 23 to 35 degrees for passive self-ligating brackets with a 0.019 x 0.025 inch stainless steel wire.
Topics: Dental Alloys; Humans; Materials Testing; Orthodontic Appliance Design; Orthodontic Brackets; Orthodontic Wires; Stainless Steel; Surface Properties; Torque; Torsion, Mechanical
PubMed: 19852662
DOI: 10.2319/080508-352.1 -
Iranian Journal of Pharmaceutical... 2019An important field of bone tissue engineering (BTE) concerns the design and fabrication of smart scaffolds capable of inducing cellular interactions and differentiation... (Review)
Review
An important field of bone tissue engineering (BTE) concerns the design and fabrication of smart scaffolds capable of inducing cellular interactions and differentiation of osteo-progenitor cells. One of these additives that has gained growing attention is metallic ions as therapeutic agents (MITAs). The specific biological advantage that these ions bring to scaffolds as well as other potential mechanical, and antimicrobial enhancements may vary depending on the ion entity, fabrication method, and biomaterials used. Therefore, this article provides an overview on current status of application of MITAs in BTE and the remaining challenges in the field. Electronic databases, including PubMed, Scopus, Science direct and Cochrane library were searched for studies on MITAs treatments for BTE. We searched for articles in English from January-2000 to October-2019. Abstracts, letters, conference papers and reviews, studies, studies on alloys and studies investigating effects other than enhancement of new bone formation (NBF) were excluded. A detailed summary of relevant metallic ions with specific scaffold material and design, cell type, animal model and defect type, the implantation period, measured parameters and obtained qualitative and quantitative results is presented. No ideal material or fabrication method suited to deliver MITAs can yet be agreed upon, but an investigation into various systems and their drawbacks or potential advantages can lead the future research. A tendency to enhance NBF with MITAs can be observed in the studies. However, this needs to be validated with further studies comparing various ions with each other in the same animal model using critical-sized defects.
PubMed: 32802092
DOI: 10.22037/ijpr.2020.112641.13894 -
Biological Trace Element Research Sep 2011The present review is based on a survey of 21 studies on the cytocompatibility of medical biomaterials containing nickel, as assessed by cell culture of human and animal... (Review)
Review
The present review is based on a survey of 21 studies on the cytocompatibility of medical biomaterials containing nickel, as assessed by cell culture of human and animal osteoblasts or osteoblast-like cells. Among the biomaterials evaluated were stainless steel, NiTi alloys, pure Ni, Ti, and other pure metals. The materials were either commercially available, prepared by the authors, or implanted by various techniques to generate a protective layer of oxides, nitrides, acetylides. The observation that the layers significantly reduced the initial release of metal ions and increased cytocompatibility was confirmed in cell culture experiments. Physical and chemical characterization of the materials was performed. This included, e.g., surface characterization (roughness, wettability, corrosion behavior, quantity of released ions, microhardness, and characterization of passivation layer). Cytocompatibility tests of the materials were conducted in the cultures of human or animal osteoblasts and osteoblast-like cells. The following assays were carried out: cell proliferation and viability test, adhesion test, morphology (by fluorescent microscopy or SEM). Also phenotypic and genotypic markers were investigated. In the majority of works, it was found that the most cytocompatible materials were stainless steel and NiTi alloy. Pure Ni was rendered and less cytocompatible. All the papers confirmed that the consequence of the formation of protective layers was in significant increase of cytocompatibility of the materials. This indicates the possible further modifications of the manufacturing process (formation of the passivation layer).
Topics: Animals; Biocompatible Materials; Cell Proliferation; Cell Survival; Humans; Nickel; Osteoblasts
PubMed: 20703824
DOI: 10.1007/s12011-010-8798-7 -
Heliyon Mar 2023There is no consensus in the literature about the best non-cytotoxic antibacterial surface treatment for dental implants. Critically evaluate the existing literature and...
There is no consensus in the literature about the best non-cytotoxic antibacterial surface treatment for dental implants. Critically evaluate the existing literature and answer the question: "which surface treatment for dental implants made of titanium and its alloys has the greatest non-cytotoxic antibacterial activity for osteoblastic cells?" This systematic review was registered in the Open Science Framework (osf.io/8fq6p) and followed the Preferred Reporting Items for Systematic Review and Meta-analysis Protocols. The search strategy was applied to four databases. Articles were selected that evaluated in both studies the properties of 1) antibacterial activity and 2) cytotoxicity on osteoblastic cells of titanium and their alloy dental implants when treated superficially. Systematic reviews, book chapters, observational studies, case reports, articles that studied non-dental implants, and articles that evaluated only the development of surface treatment were excluded. The Joanna Briggs Institute, a quasi-experimental study assessment tool, was adapted to assess the risk of bias. The search strategy found 1178 articles in the databases after removing duplicates in EndNote Web, resulting in 1011 articles to be evaluated by title and abstract, of which 21 were selected for full reading, of which 12 were included by eligibility criteria, and nine were excluded. Quantitative synthesis could not be performed due to the heterogeneity of the data (surface treatment, antibacterial assay, bacteria strain, cell viability assay, and cell type). Risk of bias assessment showed that ten studies were classified as low risk and two studies as moderate risk. The evaluated literature allowed us to conclude that: 1) The literature surveyed did not allow answering the question due to the heterogeneity of the studies; 2) Ten of the 12 studies evaluated presented surface treatments with non-cytotoxic antibacterial activity; 3) Adding nanomaterials, QPEI, BG, and CS, reduce the chances of bacterial resistance by controlling their adhesion by electrical forces.
PubMed: 36895374
DOI: 10.1016/j.heliyon.2023.e13693 -
Clinical Psychology Review Dec 2016Heart rate variability has received growing attention in the depression literature, with several recent meta-analyses indicating that lower resting heart rate... (Review)
Review
Heart rate variability has received growing attention in the depression literature, with several recent meta-analyses indicating that lower resting heart rate variability is associated with depression. However, the role of fluctuations in heart rate variability (or reactivity) in response to stress in depression remains less clear. The present review provides a systematic examination of the literature on heart rate variability reactivity to a laboratory-induced stressor task and depression, including 26 studies of reactivity in heart rate variability and clinical depression, remitted (or history of) depression, and subthreshold depression (or symptom-level depression) among adults, adolescents, and children. In addition to reviewing the findings of these studies, methodological considerations and conceptual gaps in the literature are addressed. We conclude by highlighting the importance of investigating the potential transactional relationship between heart rate variability reactivity and depression and possible mechanisms underlying this relationship.
Topics: Adolescent; Adult; Aging; Child; Depressive Disorder; Heart Rate; Humans; Stress, Psychological
PubMed: 27697746
DOI: 10.1016/j.cpr.2016.09.003 -
World Journal of Gastroenterology Sep 2016To investigate the efficacy of double-layered covered stent in the treatment of malignant oesophageal obstructions. (Meta-Analysis)
Meta-Analysis Review
AIM
To investigate the efficacy of double-layered covered stent in the treatment of malignant oesophageal obstructions.
METHODS
A systematic review and meta-analysis was performed following the PRISMA process. PubMed (Medline), EMBASE (Excerpta Medical Database), AMED (Allied and Complementary medicine Database), Scopus and online content, were searched for studies reporting on the NiTi-S polyurethane-covered double oesophageal stent for the treatment of malignant dysphagia. Weighted pooled outcomes were synthesized with a random effects model to account for clinical heterogeneity. All studies reporting the outcome of palliative management of dysphagia due to histologically confirmed malignant oesophageal obstruction using double-layered covered nitinol stent were included. The level of statistical significance was set at α = 0.05.
RESULTS
Six clinical studies comprising 250 patients in total were identified. Pooled technical success of stent insertion was 97.2% (95%CI: 94.8%-98.9%; I (2) = 5.8%). Pooled complication rate was 27.6% (95%CI: 20.7%-35.2%; I (2) = 41.9%). Weighted improvement of dysphagia on a scale of 0-5 scoring system was -2.00 [95%CI: -2.29%-(-1.72%); I (2) = 87%]. Distal stent migration was documented in 10 out of the 250 cases examined. Pooled stent migration rate was 4.7% (95%CI: 2.5%-7.7%; I (2) = 0%). Finally, tumour overgrowth was reported in 34 out of the 250 cases with pooled rate of tumour overgrowth of 11.2% (95%CI: 3.7%-22.1%; I (2) = 82.2%). No funnel plot asymmetry to suggest publication bias (bias = 0.39, P = 0.78). In the sensitivity analysis all results were largely similar between the fixed and random effects models.
CONCLUSION
The double-layered nitinol stent provides immediate relief of malignant dysphagia with low rates of stent migration and tumour overgrowth.
Topics: Adult; Aged; Aged, 80 and over; Alloys; Deglutition Disorders; Esophageal Neoplasms; Esophageal Stenosis; Female; Humans; Male; Middle Aged; Neoplasm Recurrence, Local; Statistics as Topic; Stents; Treatment Outcome
PubMed: 27678367
DOI: 10.3748/wjg.v22.i34.7841