-
American Journal of Obstetrics and... May 2023Green-stained amniotic fluid, often referred to as meconium-stained amniotic fluid, is present in 5% to 20% of patients in labor and is considered an obstetric hazard.... (Review)
Review
Green-stained amniotic fluid, often referred to as meconium-stained amniotic fluid, is present in 5% to 20% of patients in labor and is considered an obstetric hazard. The condition has been attributed to the passage of fetal colonic content (meconium), intraamniotic bleeding with the presence of heme catabolic products, or both. The frequency of green-stained amniotic fluid increases as a function of gestational age, reaching approximately 27% in post-term gestation. Green-stained amniotic fluid during labor has been associated with fetal acidemia (umbilical artery pH <7.00), neonatal respiratory distress, and seizures as well as cerebral palsy. Hypoxia is widely considered a mechanism responsible for fetal defecation and meconium-stained amniotic fluid; however, most fetuses with meconium-stained amniotic fluid do not have fetal acidemia. Intraamniotic infection/inflammation has emerged as an important factor in meconium-stained amniotic fluid in term and preterm gestations, as patients with these conditions have a higher rate of clinical chorioamnionitis and neonatal sepsis. The precise mechanisms linking intraamniotic inflammation to green-stained amniotic fluid have not been determined, but the effects of oxidative stress in heme catabolism have been implicated. Two randomized clinical trials suggest that antibiotic administration decreases the rate of clinical chorioamnionitis in patients with meconium-stained amniotic fluid. A serious complication of meconium-stained amniotic fluid is meconium aspiration syndrome. This condition develops in 5% of cases presenting with meconium-stained amniotic fluid and is a severe complication typical of term newborns. Meconium aspiration syndrome is attributed to the mechanical and chemical effects of aspirated meconium coupled with local and systemic fetal inflammation. Routine naso/oropharyngeal suctioning and tracheal intubation in cases of meconium-stained amniotic fluid have not been shown to be beneficial and are no longer recommended in obstetrical practice. A systematic review of randomized controlled trials suggested that amnioinfusion may decrease the rate of meconium aspiration syndrome. Histologic examination of the fetal membranes for meconium has been invoked in medical legal litigation to time the occurrence of fetal injury. However, inferences have been largely based on the results of in vitro experiments, and extrapolation of such findings to the clinical setting warrants caution. Fetal defecation throughout gestation appears to be a physiologic phenomenon based on ultrasound as well as in observations in animals.
Topics: Infant, Newborn; Pregnancy; Female; Humans; Meconium Aspiration Syndrome; Meconium; Amniotic Fluid; Chorioamnionitis; Pregnancy Complications; Inflammation; Heme
PubMed: 37012128
DOI: 10.1016/j.ajog.2022.11.1283 -
Ultrasound in Obstetrics & Gynecology :... Apr 2023Universal screening for cytomegalovirus (CMV) infection in pregnancy is not recommended in most countries. One of the major deterrents is the lack of effective prenatal... (Meta-Analysis)
Meta-Analysis Review
OBJECTIVE
Universal screening for cytomegalovirus (CMV) infection in pregnancy is not recommended in most countries. One of the major deterrents is the lack of effective prenatal therapy. The role of valacyclovir therapy in reducing the risk of vertical transmission, symptomatic congenital CMV infection and adverse outcome is controversial. The main aim of this systematic review and meta-analysis was to investigate the safety and effectiveness of prenatal valacyclovir therapy in pregnancies with maternal CMV infection.
METHODS
MEDLINE, EMBASE and Cochrane databases and ClinicalTrials.gov were searched. The inclusion criteria were pregnancy with confirmed maternal CMV infection, treated or untreated with valacyclovir. The primary outcome was the incidence of congenital CMV infection confirmed by a positive CMV polymerase chain reaction result of the amniotic fluid. The secondary outcomes were symptomatic and asymptomatic infection, perinatal death, termination of pregnancy, anomalies detected on follow-up ultrasound, on fetal magnetic resonance imaging or at birth, severe and mild-to-moderate symptoms due to congenital CMV infection, neurological, visual and hearing symptoms, and adverse events related to valacyclovir. Risk of bias was assessed using the revised Cochrane risk-of-bias tool for randomized trials (RoB 2) or Risk Of Bias In Non-randomized Studies of Interventions (ROBINS-I) tool, as appropriate. Head-to-head meta-analyses were used to compare the risk of each of the explored outcomes according to whether pregnancies with maternal CMV infection were treated with prenatal valacyclovir therapy.
RESULTS
Eight studies (620 women) were included. Pregnancies treated with valacyclovir had a significantly lower risk of congenital CMV infection compared with those not receiving valacyclovir (three studies; 325 fetuses; pooled odds ratio (OR), 0.37 (95% CI, 0.21-0.64); I = 0%; P < 0.001). When stratifying the analysis according to gestational age at maternal infection, the risk of vertical transmission was significantly lower in pregnancies receiving valacyclovir following first-trimester maternal infection (three studies; 184 fetuses; pooled OR, 0.34 (95% CI, 0.15-0.74); I = 20.9%; P = 0.001), while there was no significant difference between the two groups in those acquiring CMV infection in the periconceptional period or in the third trimester of pregnancy. Only one study reported on the risk of vertical transmission in women infected in the second trimester, demonstrating a lower risk of congenital infection in women taking valacyclovir, although this was based on a small number of cases. Pregnancies treated with valacyclovir therapy had an increased likelihood of asymptomatic congenital CMV infection compared with those not receiving valacyclovir (two studies; 132 fetuses; pooled OR, 2.98 (95% CI, 1.18-7.55); I = 0%; P = 0.021), while there was no significant difference between the two groups in the risk of perinatal death (P = 0.923), termination of pregnancy (P = 0.089), anomalies detected at follow-up imaging assessment during pregnancy or at birth (P = 0.934) and symptoms due to CMV infection in the newborn (P = 0.092). The occurrence of all adverse events in pregnant individuals taking valacyclovir was 3.17% (95% CI, 1.24-5.93%) (six studies; 210 women), with 1.71% (95% CI, 0.41-3.39%) experiencing acute renal failure, which resolved after discontinuation of the drug. On GRADE assessment, the quality of evidence showing that valacyclovir reduced the risk of congenital CMV infection and adverse perinatal outcome was very low.
CONCLUSIONS
Prenatal valacyclovir administration in pregnancies with maternal CMV infection reduces the risk of congenital CMV infection. Further evidence is needed to elucidate whether valacyclovir can affect the course of infection in the fetus and the risk of symptomatic fetal or neonatal infection. © 2022 International Society of Ultrasound in Obstetrics and Gynecology.
Topics: Female; Humans; Infant, Newborn; Pregnancy; Amniotic Fluid; Cytomegalovirus Infections; Infectious Disease Transmission, Vertical; Perinatal Death; Pregnancy Complications, Infectious; Prenatal Care; Valacyclovir
PubMed: 36484439
DOI: 10.1002/uog.26136 -
Ultrasound in Obstetrics & Gynecology :... Mar 2023To analyze outcomes of singleton pregnancies with idiopathic polyhydramnios through a systematic review and meta-analysis. (Meta-Analysis)
Meta-Analysis Review
OBJECTIVE
To analyze outcomes of singleton pregnancies with idiopathic polyhydramnios through a systematic review and meta-analysis.
METHODS
Electronic databases, including MEDLINE, OVID, EBSCO, Cochrane collection and Science Citation Index, were searched from 1946 to 2019. Gray literature and tables of contents of relevant journals were also screened. Prospective and retrospective studies with a control group were included. Two authors independently reviewed the abstracts retrieved from the literature search. Inclusion criteria were: studies documented in English, singleton pregnancy and idiopathic polyhydramnios determined by amniotic fluid volume assessment on ultrasound. Exclusion criteria were: maternal diabetes, fetal structural or chromosomal anomaly, alloimmunization and intrauterine fetal infection.
RESULTS
Twelve studies met the inclusion criteria, giving a total of 2392 patients with idiopathic polyhydramnios and 160 135 patients with normal amniotic fluid volume. Pregnancies complicated by idiopathic polyhydramnios were at a higher risk of neonatal death (odds ratio (OR), 8.68 (95% CI, 2.91-25.87)), intrauterine fetal demise (OR, 7.64 (95% CI, 2.50-23.38)), neonatal intensive care unit admission (OR, 1.94 (95% CI, 1.45-2.59)), 5-min Apgar score < 7 (OR, 2.21 (95% CI, 1.34-3.62)), macrosomia (OR, 2.93 (95% CI, 2.39-3.59)), malpresentation (OR, 2.73 (95% CI, 2.06-3.61)) and Cesarean delivery (OR, 2.31 (95% CI, 1.79-2.99)).
CONCLUSIONS
This study suggests that pregnancies complicated by idiopathic polyhydramnios are at increased risk of adverse outcome. Future investigations should aim to determine an amniotic fluid volume threshold above which antenatal fetal surveillance is appropriate in the management of these pregnancies. © 2022 International Society of Ultrasound in Obstetrics and Gynecology.
Topics: Infant, Newborn; Pregnancy; Humans; Female; Polyhydramnios; Pregnancy Outcome; Retrospective Studies; Prospective Studies; Amniotic Fluid
PubMed: 35723677
DOI: 10.1002/uog.24973 -
Ultrasound in Obstetrics & Gynecology :... Apr 2017To evaluate adverse pregnancy outcomes in singleton pregnancies diagnosed with oligohydramnios through a systematic review and meta-analysis of controlled trials. (Meta-Analysis)
Meta-Analysis Review
OBJECTIVE
To evaluate adverse pregnancy outcomes in singleton pregnancies diagnosed with oligohydramnios through a systematic review and meta-analysis of controlled trials.
METHODS
We searched electronic databases via OVID, EBSCO, Web of Science, Google Scholar and others from 1980 to 2015. Prospective and retrospective studies with a control group were included. Two authors independently reviewed the abstracts from the literature search. Inclusion criteria were: studies in English, singleton pregnancy, normal fetal anatomy, intact membranes and oligohydramnios determined by the amniotic fluid index (AFI) technique. We stratified the meta-analysis into two groups according to risk: high risk including studies of oligohydramnios with comorbid conditions (e.g. hypertension) and low risk including studies of isolated oligohydramnios.
RESULTS
Fifteen trials met the inclusion criteria. Nine were high-risk and six were low-risk studies, including 8067 and 27 526 women, respectively. Compared with women with normal AFI, those with isolated oligohydramnios had significantly higher rates of an infant with meconium aspiration syndrome (relative risk (RR), 2.83; 95% CI, 1.38-5.77), Cesarean delivery for fetal distress (RR, 2.16; 95% CI, 1.64-2.85) and admission to the neonatal intensive care unit (NICU) (RR, 1.71; 95% CI, 1.20-2.42). Patients with oligohydramnios and comorbidities were more likely to have an infant with low birth weight (RR, 2.35; 95% CI, 1.27-4.34). However, rates of 5-min Apgar score < 7 (RR, 1.85; 95% CI, 0.69-4.96), NICU admission (RR, 2.09; 95% CI, 0.80-5.45), meconium-stained amniotic fluid (RR, 1.32; 95% CI, 0.62-2.81) and Cesarean delivery for fetal distress (RR, 1.65; 95% CI, 0.81-3.36) were similar to those for women with normal AFI. Stillbirth rates were too low to analyze in the meta-analysis.
CONCLUSIONS
This review helps to delineate which adverse outcomes are increased with oligohydramnios in low-risk pregnancy (NICU admission, Cesarean delivery for fetal distress and meconium aspiration syndrome), but does not provide enough data to determine the optimal timing of delivery in such cases. Oligohydramnios in complicated pregnancy is associated with an increased risk of delivery of an infant with low birth weight, but this may be confounded by the comorbid condition. Therefore, in high-risk pregnancy, management should be dictated by the comorbid condition and not the presence of oligohydramnios. Copyright © 2016 ISUOG. Published by John Wiley & Sons Ltd.
Topics: Birth Weight; Clinical Trials as Topic; Female; Humans; Infant, Newborn; Oligohydramnios; Pregnancy; Pregnancy Complications; Pregnancy Outcome
PubMed: 27062200
DOI: 10.1002/uog.15929 -
Archives of Gynecology and Obstetrics Jul 2021In December 2019, a novel coronavirus disease (COVID-19) emerged in Wuhan, China, with an incredible contagion rate. However, the vertical transmission of COVID-19 is... (Review)
Review
BACKGROUND
In December 2019, a novel coronavirus disease (COVID-19) emerged in Wuhan, China, with an incredible contagion rate. However, the vertical transmission of COVID-19 is uncertain.
OBJECTIVES
This is a systematic review of published studies concerning pregnant women with confirmed COVID-19 and their neonates.
SEARCH STRATEGY
We carried out a systematic search in multiple databases, including PubMed, Web of Science, Google Scholar, Scopus, and WHO COVID-19 database using the following keywords: (Coronavirus) OR (novel coronavirus) OR (COVID-19) OR (COVID19) OR (COVID 19) OR (SARS-CoV2) OR (2019-nCoV)) and ((pregnancy) OR (pregnant) OR (vertical transmission) OR (neonate) OR (newborn) OR (placenta) OR (fetus) OR (Fetal)). The search took place in April 2020.
SELECTION CRITERIA
Original articles published in English were eligible if they included pregnant patients infected with COVID-19 and their newborns.
DATA COLLECTION AND ANALYSES
The outcomes of interest consisted of clinical manifestations of COVID-19 in pregnant patients with COVID-19 and also the effect of COVID-19 on neonatal and pregnancy outcomes.
MAIN RESULTS
37 articles involving 364 pregnant women with COVID-19 and 302 neonates were included. The vast majority of pregnant patients were in their third trimester of pregnancy, and only 45 cases were in the first or second trimester (12.4%). Most mothers described mild to moderate manifestations of COVID-19. Of 364 pregnant women, 25 were asymptomatic at the time of admission. The most common symptoms were fever (62.4%) and cough (45.3%). Two maternal deaths occurred. Some pregnant patients (12.1%) had a negative SARS-CoV-2 test but displayed clinical manifestations and abnormalities in computed tomography (CT) scan related to COVID-19. Twenty-two (6.0%) pregnant patients developed severe pneumonia. Two maternal deaths occurred from severe pneumonia and multiple organ dysfunction. Studies included a total of 302 neonates from mothers with COVID-19. Of the studies that provided data on the timing of birth, there were 65 (23.6%) preterm neonates. One baby was born dead from a mother who also died from COVID-19. Of the babies born alive from mothers with COVID-19, five newborns faced critical conditions, and two later died. A total of 219 neonates underwent nasopharyngeal specimen collection for SARS-CoV-2, of which 11 tested positive (5%). Seventeen studies examined samples of the placenta, breast milk, umbilical cord, and amniotic fluid, and all tested negative except one amniotic fluid sample.
CONCLUSIONS
A systematic review of published studies confirm that the course of COVID-19 in pregnant women resembles that of other populations. However, there is not sufficient evidence to establish an idea that COVID-19 would not complicate pregnancy.
Topics: Adult; Amniotic Fluid; COVID-19; Female; Fever; Humans; Infant, Newborn; Infectious Disease Transmission, Vertical; Mothers; Pregnancy; Pregnancy Complications, Infectious; Pregnancy Outcome; Pregnancy Trimester, Third; Pregnant Women; RNA, Viral; SARS-CoV-2
PubMed: 33797605
DOI: 10.1007/s00404-021-06049-z -
Acta Obstetricia Et Gynecologica... Jun 2019The primary aim of this systematic review was to quantify the diagnostic performance of ultrasound, magnetic resonance imaging and amniotic fluid analysis in detecting... (Meta-Analysis)
Meta-Analysis
INTRODUCTION
The primary aim of this systematic review was to quantify the diagnostic performance of ultrasound, magnetic resonance imaging and amniotic fluid analysis in detecting esophageal atresia prenatally. The secondary aim was to explore the accuracy of individual imaging signs in identifying this anomaly.
MATERIAL AND METHODS
MEDLINE, Embase and Cochrane databases were searched. The quality of studies was assessed using the revised tool for the quality assessment of diagnostic accuracy studies. Summary estimates of sensitivity, specificity, positive and negative likelihood ratios, and diagnostic odds ratio for the predictive accuracy of ultrasound, magnetic resonance imaging and amniotic fluid analysis in detecting esophageal atresia were computed using the hierarchical summary receiver operating characteristic or DerSimonian-Laird random-effect model, according to the number of studies included in each analysis. PROSPERO registration number: CRD42017055828.
RESULTS
Twenty studies (73 246 fetuses, 1760 affected by esophageal atresia) were included. Overall, prenatal ultrasound had a sensitivity of 31.7%. Only two studies reported all data for diagnostic accuracy; based on these studies, prenatal ultrasound had a sensitivity of 41.9%, a specificity of 99.9%, a positive likelihood ratio of 88.1, a negative likelihood ratio of 0.58 and a diagnostic odds ratio of 153.7. Prenatal ultrasound correctly identified 77.9% of cases with esophageal atresia and 21.9% esophageal atresia with an associated tracheo-esophageal fistula. Polyhydramnios was present in 56.3% of cases affected by esophageal atresia, and a small or absent stomach was identified in 50.0% cases. When performed following a suspicious ultrasound, fetal magnetic resonance imaging had an good overall diagnostic accuracy for esophageal atresia, with a sensitivity of 94.7%, a specificity of 89.3%, a positive likelihood ratio of 8.8, a negative likelihood ratio of 0.06 and a diagnostic odds ratio of 149.3. Finally, amniotic fluid analysis with an esophageal atresia index ≥3 had a sensitivity of 89.9% and a specificity of 99.6% in detecting esophageal atresia.
CONCLUSIONS
Ultrasound alone is a poor diagnostic tool for identifying esophageal atresia prenatally, and has a high rate of false positive diagnoses. Magnetic resonance imaging and amniotic fluid analysis have high diagnostic accuracy for esophageal atresia. We would recommend their use following a suspicious ultrasound.
Topics: Esophageal Atresia; Humans; Prenatal Diagnosis; Reproducibility of Results
PubMed: 30659586
DOI: 10.1111/aogs.13536 -
The Cochrane Database of Systematic... Sep 2017During pregnancy, fetal cells suitable for genetic testing can be obtained from amniotic fluid by amniocentesis (AC), placental tissue by chorionic villus sampling... (Review)
Review
BACKGROUND
During pregnancy, fetal cells suitable for genetic testing can be obtained from amniotic fluid by amniocentesis (AC), placental tissue by chorionic villus sampling (CVS), or fetal blood. A major disadvantage of second trimester amniocentesis is that the results are available relatively late in pregnancy (after 16 weeks' gestation). Earlier alternatives are chorionic villus sampling (CVS) and early amniocentesis, which can be performed in the first trimester of pregnancy.
OBJECTIVES
The objective of this review was to compare the safety and accuracy of all types of AC (i.e. early and late) and CVS (e.g. transabdominal, transcervical) for prenatal diagnosis.
SEARCH METHODS
We searched the Cochrane Pregnancy and Childbirth Group's Trials Register (3 March 2017), ClinicalTrials.gov, the WHO International Clinical Trials Registry Platform (ICTRP; 3 March 2017), and reference lists of retrieved studies.
SELECTION CRITERIA
All randomised trials comparing AC and CVS by either transabdominal or transcervical route.
DATA COLLECTION AND ANALYSIS
Two review authors independently assessed trials for inclusion and risk of bias, extracted data and checked them for accuracy. The quality of the evidence was assessed using the GRADE approach.
MAIN RESULTS
We included a total of 16 randomised studies, with a total of 33,555 women, 14 of which were deemed to be at low risk of bias. The number of women included in the trials ranged from 223 to 4606.Studies were categorized into six comparisons: 1. second trimester AC versus control; 2. early versus second trimester AC; 3. CVS versus second trimester AC; 4. CVS methods; 5. Early AC versus CVS; and 6. AC with or without ultrasound.One study compared second trimester AC with no AC (control) in a low risk population (women = 4606). Background pregnancy loss was around 2%. Second trimester AC compared to no testing increased total pregnancy loss by another 1%. The confidence intervals (CI) around this excess risk were relatively large (3.2% versus 2.3 %, average risk ratio (RR) 1.41, 95% CI 0.99 to 2.00; moderate-quality evidence). In the same study, spontaneous miscarriages were also higher (2.1% versus 1.3%; average RR 1.60, 95% CI 1.02 to 2.52; high-quality evidence). The number of congenital anomalies was similar in both groups (2.0% versus 2.2%, average RR 0.93, 95% CI 0.62 to 1.39; moderate-quality evidence).One study (women = 4334) found that early amniocentesis was not a safe early alternative compared to second trimester amniocentesis because of increased total pregnancy losses (7.6% versus 5.9%; average RR 1.29, 95% CI 1.03 to 1.61; high-quality evidence), spontaneous miscarriages (3.6% versus 2.5%, average RR 1.41, 95% CI 1.00 to 1.98; moderate-quality evidence), and a higher incidence of congential anomalies, including talipes (4.7% versus 2.7%; average RR 1.73, 95% CI 1.26 to 2.38; high-quality evidence).When pregnancy loss after CVS was compared with second trimester AC, there was a clinically significant heterogeneity in the size and direction of the effect depending on the technique used (transabdominal or transcervical), therefore, the results were not pooled. Only one study compared transabdominal CVS with second trimester AC (women = 2234). They found no clear difference between the two procedures in the total pregnancy loss (6.3% versus 7%; average RR 0.90, 95% CI 0.66 to 1.23, low-quality evidence), spontaneous miscarriages (3.0% versus 3.9%; average RR 0.77, 95% CI 0.49 to 1.21; low-quality evidence), and perinatal deaths (0.7% versus 0.6%; average RR 1.18, 95% CI 0.40 to 3.51; low-quality evidence). Transcervical CVS may carry a higher risk of pregnancy loss (14.5% versus 11.5%; average RR 1.40, 95% CI 1.09 to 1.81), but the results were quite heterogeneous.Five studies compared transabdominal and transcervical CVS (women = 7978). There were no clear differences between the two methods in pregnancy losses (average RR 1.16, 95% CI 0.81 to 1.65; very low-quality evidence), spontaneous miscarriages (average RR 1.68, 95% CI 0.79 to 3.58; very low-quality evidence), or anomalies (average RR 0.68, 95% CI 0.41 to 1.12; low-quality evidence). We downgraded the quality of the evidence to low due to heterogeneity between studies. Transcervical CVS may be more technically demanding than transabdominal CVS, with more failures to obtain sample (2.0% versus 1.1%; average RR 1.79, 95% CI 1.13 to 2.82, moderate-quality evidence).Overall, we found low-quality evidence for outcomes when early amniocentesis was compared to transabdominal CVS. Spontaneous miscarriage was the only outcome supported by moderate-quality evidence, resulting in more miscarriages after early AC compared with transabdominal CVS (2.3% versus 1.3%; average RR 1.73, 95% CI 1.15 to 2.60). There were no clear differences in pregnancy losses (average RR 1.15, 95% CI 0.86 to 1.54; low-quality evidence), or anomalies (average RR 1.14, 95% CI 0.57 to 2.30; very low-quality evidence).We found one study that examined AC with or without ultrasound, which evaluated a type of ultrasound-assisted procedure that is now considered obsolete.
AUTHORS' CONCLUSIONS
Second trimester amniocentesis increased the risk of pregnancy loss, but it was not possible to quantify this increase precisely from only one study, carried out more than 30 years ago.Early amniocentesis was not as safe as second trimester amniocentesis, illustrated by increased pregnancy loss and congenital anomalies (talipes). Transcervical chorionic villus sampling compared with second trimester amniocentesis may be associated with a higher risk of pregnancy loss, but results were quite heterogeneous.Diagnostic accuracy of different methods could not be assessed adequately because of incomplete karyotype data in most studies.
Topics: Amniocentesis; Chorionic Villi Sampling; Congenital Abnormalities; Female; Humans; Pregnancy; Pregnancy Trimester, First; Pregnancy Trimester, Second; Randomized Controlled Trials as Topic
PubMed: 28869276
DOI: 10.1002/14651858.CD003252.pub2 -
The Cochrane Database of Systematic... Mar 2023Mechanical methods were the first methods developed to ripen the cervix and induce labour. During recent decades they have been substituted by pharmacological methods.... (Review)
Review
BACKGROUND
Mechanical methods were the first methods developed to ripen the cervix and induce labour. During recent decades they have been substituted by pharmacological methods. Potential advantages of mechanical methods, compared with pharmacological methods may include reduction in side effects that could improve neonatal outcomes. This is an update of a review first published in 2001, last updated in 2012.
OBJECTIVES
To determine the effectiveness and safety of mechanical methods for third trimester (> 24 weeks' gestation) induction of labour in comparison with prostaglandin E2 (PGE2) (vaginal and intracervical), low-dose misoprostol (oral and vaginal), amniotomy or oxytocin.
SEARCH METHODS
For this update, we searched Cochrane Pregnancy and Childbirth's Trials Register, ClinicalTrials.gov, the WHO International Clinical Trials Registry Platform (ICTRP), and reference lists of retrieved studies (9 January 2018). We updated the search in March 2019 and added the search results to the awaiting classification section of the review.
SELECTION CRITERIA
Clinical trials comparing mechanical methods used for third trimester cervical ripening or labour induction with pharmacological methods. Mechanical methods include: (1) the introduction of a catheter through the cervix into the extra-amniotic space with balloon insufflation; (2) introduction of laminaria tents, or their synthetic equivalent (Dilapan), into the cervical canal; (3) use of a catheter to inject fluid into the extra-amniotic space (EASI). This review includes the following comparisons: (1) specific mechanical methods (balloon catheter, laminaria tents or EASI) compared with prostaglandins (different types, different routes) or with oxytocin; (2) single balloon compared to a double balloon; (3) addition of prostaglandins or oxytocin to mechanical methods compared with prostaglandins or oxytocin alone.
DATA COLLECTION AND ANALYSIS
Two review authors independently assessed trials for inclusion and assessed risk of bias. Two review authors independently extracted data and assessed the quality of the evidence using the GRADE approach.
MAIN RESULTS
This review includes a total of 112 trials, with 104 studies contributing data (22,055 women; 21 comparisons). Risk of bias of trials varied. Overall, the evidence was graded from very-low to moderate quality. All evidence was downgraded for lack of blinding and, for many comparisons, the effect estimates were too imprecise to make a valid judgement. Balloon versus vaginal PGE2: there may be little or no difference in vaginal deliveries not achieved within 24 hours (risk ratio (RR) 1.01, 95% confidence interval (CI) 0.82 to 1.26; 7 studies; 1685 women; low-quality evidence) and there probably is little or no difference in caesarean sections (RR 1.00, 95% CI 0.92 to 1.09; 28 studies; 6619 women; moderate-quality evidence) between induction of labour with a balloon catheter and vaginal PGE2. A balloon catheter probably reduces the risk of uterine hyperstimulation with fetal heart rate (FHR) changes (RR 0.35, 95% CI 0.18 to 0.67; 6 studies; 1966 women; moderate-quality evidence), serious neonatal morbidity or perinatal death (RR 0.48, 95% CI 0.25 to 0.93; 8 studies; 2757 women; moderate-quality evidence) and may slightly reduce the risk of aneonatal intensive care unit (NICU) admission (RR 0.82, 95% CI 0.65 to 1.04; 3647 women; 12 studies; low-quality evidence). It is uncertain whether there is a difference in serious maternal morbidity or death (RR 0.20, 95% CI 0.01 to 4.12; 4 studies; 1481 women) or five-minute Apgar score < 7 (RR 0.74, 95% CI 0.49 to 1.14; 4271 women; 14 studies) because the quality of the evidence was found to be very low and low, respectively. Balloon versus low-dose vaginal misoprostol: it is uncertain whether there is a difference in vaginal deliveries not achieved within 24 hours between induction of labour with a balloon catheter and vaginal misoprostol (RR 1.09, 95% CI 0.85 to 1.39; 340 women; 2 studies; low-quality evidence). A balloon catheter probably reduces the risk of uterine hyperstimulation with FHR changes (RR 0.39, 95% CI 0.18 to 0.85; 1322 women; 8 studies; moderate-quality evidence) but may increase the risk of a caesarean section (RR 1.28, 95% CI 1.02 to 1.60; 1756 women; 12 studies; low-quality evidence). It is uncertain whether there is a difference in serious neonatal morbidity or perinatal death (RR 0.58, 95% CI 0.12 to 2.66; 381 women; 3 studies), serious maternal morbidity or death (no events; 4 studies, 464 women), both very low-quality evidence, and five-minute Apgar score < 7 (RR 1.00, 95% CI 0.50 to 1.97; 941 women; 7 studies) and NICU admissions (RR 1.00, 95% CI 0.61 to 1.63; 1302 women; 9 studies) both low-quality evidence. Balloon versus low-dose oral misoprostol: a balloon catheter probably increases the risk of a vaginal delivery not achieved within 24 hours (RR 1.28, 95% CI 1.13 to 1.46; 782 women, 2 studies, and probably slightly increases the risk of a caesarean section (RR 1.17, 95% CI 1.04 to 1.32; 3178 women; 7 studies; both moderate-quality evidence) when compared to oral misoprostol. It is uncertain whether there is a difference in uterine hyperstimulation with FHR changes (RR 0.81, 95% CI 0.48 to 1.38; 2033 women; 2 studies), serious neonatal morbidity or perinatal death (RR 1.11, 95% CI 0.60 to 2.06; 2627 women; 3 studies), both low-quality evidence, serious maternal morbidity or death (RR 0.50, 95% CI 0.05 to 5.52; 2627 women; 3 studies), very low-quality evidence, five-minute Apgar scores < 7 (RR 0.71, 95% CI 0.38 to 1.32; 2693 women; 4 studies) and NICU admissions (RR 0.82, 95% CI 0.58 to 1.17; 2873 women; 5 studies) both low-quality evidence.
AUTHORS' CONCLUSIONS
Low- to moderate-quality evidence shows mechanical induction with a balloon is probably as effective as induction of labour with vaginal PGE2. However, a balloon seems to have a more favourable safety profile. More research on this comparison does not seem warranted. Moderate-quality evidence shows a balloon catheter may be slightly less effective as oral misoprostol, but it remains unclear if there is a difference in safety outcomes for the neonate. When compared to low-dose vaginal misoprostol, low-quality evidence shows a balloon may be less effective, but probably has a better safety profile. Future research could be focused more on safety aspects for the neonate and maternal satisfaction.
Topics: Female; Humans; Infant, Newborn; Pregnancy; Cesarean Section; Dinoprostone; Labor, Induced; Misoprostol; Oxytocin; Perinatal Death
PubMed: 36996264
DOI: 10.1002/14651858.CD001233.pub4 -
American Journal of Perinatology Aug 2017Risk factors for placental abruption have changed, but there has not been an updated systematic review investigating outcomes. We searched PubMed, EMBASE, Web of... (Review)
Review
Risk factors for placental abruption have changed, but there has not been an updated systematic review investigating outcomes. We searched PubMed, EMBASE, Web of Science, SCOPUS, and CINAHL for publications from January 1, 2005 through December 31, 2016. We reviewed English-language publications reporting estimated incidence and/or risk factors for maternal, labor, delivery, and perinatal outcomes associated with abruption. We excluded case studies, conference abstracts, and studies that lacked a referent/comparison group or did not clearly characterize placental abruption. A total of 123 studies were included. Abruption was associated with elevated risk of cesarean delivery, postpartum hemorrhage and transfusion, preterm birth, intrauterine growth restriction or low birth weight, perinatal mortality, and cerebral palsy. Additional maternal outcomes included relaparotomy, hysterectomy, sepsis, amniotic fluid embolism, venous thromboembolism, acute kidney injury, and maternal intensive care unit admission. Additional perinatal outcomes included acidosis, encephalopathy, severe respiratory disorders, necrotizing enterocolitis, acute kidney injury, need for resuscitation, chronic lung disease, infant death, and epilepsy. Few studies examined outcomes beyond the initial birth period, but there is evidence that both mother and child are at risk of additional adverse outcomes. There was also considerable variation in, or absence of, the reporting of abruption definitions.
Topics: Abruptio Placentae; Asphyxia Neonatorum; Blood Transfusion; Cerebral Palsy; Cesarean Section; Female; Fetal Growth Retardation; Humans; Hypoxia, Brain; Infant, Low Birth Weight; Infant, Newborn; Maternal Mortality; Perinatal Mortality; Postpartum Hemorrhage; Pregnancy; Premature Birth; Recurrence; Stillbirth
PubMed: 28329897
DOI: 10.1055/s-0037-1599149 -
Acta Obstetricia Et Gynecologica... Nov 2020Several studies acknowledge that the presence of amniotic fluid sludge (AFS) is an independent predictive factor for preterm birth. In the present systematic review, we...
INTRODUCTION
Several studies acknowledge that the presence of amniotic fluid sludge (AFS) is an independent predictive factor for preterm birth. In the present systematic review, we summarize research that focuses on the comparison of pregnancy outcomes among women with and without AFS.
MATERIAL AND METHODS
Medline, Scopus, Clinicaltrials.gov, EMBASE, Cochrane Central Register of Controlled Trials (CENTRAL), and Google Scholar databases were systematically searched from inception. Both observational and randomized controlled studies were considered eligible provided that they reported data on pregnancy outcomes among women with and without AFS. Outcomes were not meta-analyzed because of the high heterogeneity in terms of selected population and outcome reporting.
RESULTS
Seventeen studies of 2432 women were included in this review. Six studies evaluated women at high risk for preterm birth. Pregnancies complicated by AFS had a lower gestational age at delivery and increased incidence of preterm delivery at <37 weeks. Neonatal death rates and admission to the Neonatal Intensive Care Unit were also increased. Evidence in low-risk women, those with signs of preterm labor, in those carrying twins, and in women with cervical cerclage or Arabin pessary was extremely limited.
CONCLUSIONS
Women with AFS seem to deliver at an earlier gestational age, and preterm birth rates are also increased. Limited data seem to point to neonatal morbidity and mortality being increased. However, the presence of a direct association should not be assumed because the evidence is not adjusted for the presence of confounders.
Topics: Amniotic Fluid; Female; Humans; Infant; Infant Mortality; Infant, Newborn; Pregnancy; Pregnancy Outcome; Premature Birth; Risk Factors; Uterine Cervical Incompetence
PubMed: 32367525
DOI: 10.1111/aogs.13893