Blood Feb 2016Immunoassays are essential in the workup of patients with suspected heparin-induced thrombocytopenia. However, the diagnostic accuracy is uncertain with regard to... (Meta-Analysis)
Meta-Analysis Review
Immunoassays are essential in the workup of patients with suspected heparin-induced thrombocytopenia. However, the diagnostic accuracy is uncertain with regard to different classes of assays, antibody specificities, thresholds, test variations, and manufacturers. We aimed to assess diagnostic accuracy measures of available immunoassays and to explore sources of heterogeneity. We performed comprehensive literature searches and applied strict inclusion criteria. Finally, 49 publications comprising 128 test evaluations in 15 199 patients were included in the analysis. Methodological quality according to the revised tool for quality assessment of diagnostic accuracy studies was moderate. Diagnostic accuracy measures were calculated with the unified model (comprising a bivariate random-effects model and a hierarchical summary receiver operating characteristics model). Important differences were observed between classes of immunoassays, type of antibody specificity, thresholds, application of confirmation step, and manufacturers. Combination of high sensitivity (>95%) and high specificity (>90%) was found in 5 tests only: polyspecific enzyme-linked immunosorbent assay (ELISA) with intermediate threshold (Genetic Testing Institute, Asserachrom), particle gel immunoassay, lateral flow immunoassay, polyspecific chemiluminescent immunoassay (CLIA) with a high threshold, and immunoglobulin G (IgG)-specific CLIA with low threshold. Borderline results (sensitivity, 99.6%; specificity, 89.9%) were observed for IgG-specific Genetic Testing Institute-ELISA with low threshold. Diagnostic accuracy appears to be inadequate in tests with high thresholds (ELISA; IgG-specific CLIA), combination of IgG specificity and intermediate thresholds (ELISA, CLIA), high-dose heparin confirmation step (ELISA), and particle immunofiltration assay. When making treatment decisions, clinicians should be a aware of diagnostic characteristics of the tests used and it is recommended they estimate posttest probabilities according to likelihood ratios as well as pretest probabilities using clinical scoring tools.
Topics: Anticoagulants; Enzyme-Linked Immunosorbent Assay; Heparin; Humans; Immunoassay; Sensitivity and Specificity; Thrombocytopenia
PubMed: 26518436
DOI: 10.1182/blood-2015-07-661215 -
Journal of Medical Virology Jan 2023We reviewed the literature on the importance of selected anti-high-risk human papillomavirus (HR-HPV) antibodies (namely, 16/18 and early oncoproteins E6 and E7) as... (Meta-Analysis)
Meta-Analysis Review
We reviewed the literature on the importance of selected anti-high-risk human papillomavirus (HR-HPV) antibodies (namely, 16/18 and early oncoproteins E6 and E7) as potential serological markers for early detection of individuals at high risk of cervical cancer. We searched for studies in PubMed and Embase databases published from 2010 to 2020 on antibodies against HR-HPV E6 and E7 early proteins and cervical cancer. Pooled sensitivity and specificity for HPV16 and HPV18 antibodies were calculated using a bivariate hierarchical random-effects model. A total of 69 articles were identified; we included three studies with 1550 participants. For the three HPV16/18 E6 and E7 antibody tests, enzyme-linked immunosorbent assay-based assays had a sensitivity of 18% for detecting CIN2+ (95% confidence interval [CI]: 15-21) and a specificity of 96% (95% CI: 92-98), for slot-blot, sensitivity was 28.9% (95% CI: 23.3-35.1) and specificity was 72% (95% CI: 66.6-77.0) for detecting CIN2+, and for multiplex HPV serology assay based on a glutathione S-transferase, sensitivity was 16% (95% CI: 8.45-28.6) and specificity was 98% (95% CI: 97-99) for detecting invasive cervical cancer. HR-HPV16/18 E6 and E7 serological markers showed high specificity, but sensitivity was suboptimal for the detection of cervical cancer in either population screening settings or as point-of-care screening tests.
Topics: Female; Humans; Uterine Cervical Neoplasms; Papillomavirus Infections; Human papillomavirus 16; Human papillomavirus 18; Oncogene Proteins, Viral; Enzyme-Linked Immunosorbent Assay; Papillomavirus E7 Proteins; Papillomaviridae
PubMed: 35641882
DOI: 10.1002/jmv.27900 -
Kidney International Jan 2015In this study, we conducted a systematic review of the literature to re-evaluate the role of C4d in the diagnosis of acute antibody-mediated rejection of kidney... (Review)
Review
In this study, we conducted a systematic review of the literature to re-evaluate the role of C4d in the diagnosis of acute antibody-mediated rejection of kidney allografts. Electronic databases were searched until September 2013. Eligible studies allowed derivation of diagnostic tables for the performance of C4d by immunofluorescence or immunohistochemistry with comparison to histopathological features of acute antibody-mediated rejection and/or donor-specific antibody (DSA) assays. Of 3492 unique abstracts, 29 studies encompassing 3485 indication and 868 surveillance biopsies were identified. Assessment of C4d by immunofluorescence and immunohistochemistry exhibited slight to moderate agreement with glomerulitis, peritubular capillaritis, solid-phase DSA assays, DSA with glomerulitis, and DSA with peritubular capillaritis. The sensitivity and specificity of C4d varied as a function of C4d and comparator test thresholds. Prognostically, the presence of C4d was associated with inferior allograft survival compared with DSA or histopathology alone. Thus, our findings support the presence of complement-dependent and -independent phenotypes of acute antibody-mediated rejection. Whether the presence of C4d in combination with histopathology or DSA should be considered for the diagnosis of acute antibody-mediated rejection warrants further study.
Topics: Acute Disease; Antibodies; Complement C4b; Fluorescent Antibody Technique; Graft Rejection; Humans; Immunohistochemistry; Kidney Transplantation; Peptide Fragments; Prognosis
PubMed: 24827778
DOI: 10.1038/ki.2014.166 -
Frontiers in Immunology 2022The diversity of three hypervariable loops in antibody heavy chain and light chain, termed the complementarity-determining regions (CDRs), defines antibody's binding...
The diversity of three hypervariable loops in antibody heavy chain and light chain, termed the complementarity-determining regions (CDRs), defines antibody's binding affinity and specificity owing to the direct contact between the CDRs and antigens. These CDR regions typically contain tyrosine (Tyr) residues that are known to engage in both nonpolar and pi stacking interaction with antigens through their complementary aromatic ring side chains. Nearly two decades ago, sulfotyrosine residue (sTyr), a negatively charged Tyr formed by Golgi-localized membrane-bound tyrosylprotein sulfotransferases during protein trafficking, were also found in the CDR regions and shown to play an important role in modulating antibody-antigen interaction. This breakthrough finding demonstrated that antibody repertoire could be further diversified through post-translational modifications, in addition to the conventional genetic recombination. This review article summarizes the current advances in the understanding of the Tyr-sulfation modification mechanism and its application in potentiating protein-protein interaction for antibody engineering and production. Challenges and opportunities are also discussed.
Topics: Complementarity Determining Regions; Immunoglobulin Heavy Chains; Antigens; Golgi Apparatus; Tyrosine
PubMed: 36569848
DOI: 10.3389/fimmu.2022.1072702 -
BMJ Open Jun 2017To perform a meta-analysis to evaluate the diagnostic performance of the antiglycoprotein-2 (GP2) antibody for Crohn's disease (CD). (Meta-Analysis)
Meta-Analysis Review
OBJECTIVES
To perform a meta-analysis to evaluate the diagnostic performance of the antiglycoprotein-2 (GP2) antibody for Crohn's disease (CD).
METHODS
Three databases (EMBASE, ISI Web of Knowledge and PubMed) were systematically searched. There were 17 eligible studies included in the meta-analysis. A total of 2439 patients with CD and 3184 controls were involved in these studies. STATA V.11.2 and Meta-DiSc V.1.4 were used to perform the meta-analysis.
RESULTS
The area under the summary receiver operating characteristic curve was 0.68-0.72. The pooled diagnostic sensitivity of the anti-GP2 antibody ranged from 14% to 24%, and the specificity was 96%-98%.
CONCLUSIONS
The anti-GP2 antibody is a specific biomarker for CD, and further exploration of its prevalence among different clinical phenotypes of CD will provide a better understanding of its diagnostic performance.
Topics: Antibodies; Area Under Curve; Biomarkers; Crohn Disease; GPI-Linked Proteins; Humans; ROC Curve
PubMed: 28601823
DOI: 10.1136/bmjopen-2016-014843 -
Journal of Clinical Laboratory Analysis Sep 2022As a chronic systemic autoimmune disease of undetermined etiology, rheumatoid arthritis (RA) has a complex pathogenesis, which involves multiple proteins and cytokines.... (Review)
Review
BACKGROUND
As a chronic systemic autoimmune disease of undetermined etiology, rheumatoid arthritis (RA) has a complex pathogenesis, which involves multiple proteins and cytokines. The 2010 ACR/EULAR classification criteria facilitate early diagnosis of RA with reduced specificity when compared to the 1987 ACR criteria. Hence, it is imperative to identify novel serological inflammatory indicators and targets, in order to explain the complex regulatory network of RA. The present review discusses the associations of various inflammatory factors with RA and its underlying mechanism. Besides, the review also provides a novel insight into the clinical treatment of RA.
MATERIALS AND METHODS
According to the PRISMA guidelines, databases like Web of Science, Google-Scholar, Pubmed and Scopus were systematically searched for articles from January 1, 2018 to January 1, 2022 using The following 2 keywords: "rheumatoid arthritis", "Inflammatory cytokines", "ILs", "serum amyloid protein A", "matrix metalloproteinase 3", "RANKL", "Glucose-6-phosphoisomerase", "Anti-keratin antibody", "1,25-Dihydroxyvitamin D3".
RESULTS
Indicators like MMPs, ILs, glucose-6-phosphate isomerase (GPI), anti-keratin antibody (AKA) and receptor activator of nuclear factor-κB ligand (RANKL) are the current hotspots in the efficacy research of RA. The present review suggests that ILs are highly expressed in the serum and synovial tissues of RA patients. By targeted inhibition of ILs with inhibitor application, precise RA treatment can be achieved.
CONCLUSIONS
Based on these results, it can be concluded that inflammatory factors have certain guiding significance in the diagnosis and efficacy evaluation of RA. However, the mechanisms of interactions among them are rather complex, which deserve further exploration.
Topics: Arthritis, Rheumatoid; Autoantibodies; Cytokines; Early Diagnosis; Humans
PubMed: 35838016
DOI: 10.1002/jcla.24576 -
PloS One 2023Traditional diagnostic tests for schistosome infections are suboptimal, particularly when the parasite burden is low. In the present review we sought to identify...
Diagnostic performances of Schistosoma haematobium and Schistosoma mansoni recombinant proteins, peptides and chimeric proteins antibody based tests. Systematic scoping review.
BACKGROUND
Traditional diagnostic tests for schistosome infections are suboptimal, particularly when the parasite burden is low. In the present review we sought to identify recombinant proteins, peptides, and chimeric proteins with potential to be used as sensitive and specific diagnostic tools for schistosomiasis.
METHODS
The review was guided by PRISMA-ScR guidelines, Arksey and O'Malley's framework, and guidelines from the Joanna Briggs Institute. Five databases were searched: Cochrane library, PubMed, EMBASE, PsycInfo and CINAHL, alongside preprints. Identified literature were assessed by two reviewers for inclusion. A narrative summary was used to interpret the tabulated results.
RESULTS
Diagnostic performances were reported as specificities, sensitivities, and AUC. The AUC for S. haematobium recombinant antigens ranged from 0.65 to 0.98, and 0.69 to 0.96 for urine IgG ELISA. S. mansoni recombinant antigens had sensitivities ranging from 65.3% to 100% and specificities ranging from 57.4% to 100%. Except for 4 peptides which had poor diagnostic performances, most peptides had sensitivities ranging from 67.71% to 96.15% and specificities ranging from 69.23% to 100%. S. mansoni chimeric protein was reported to have a sensitivity of 86.8% and a specificity of 94.2%.
CONCLUSION
The tetraspanin CD63 antigen had the best diagnostic performance for S. haematobium. The tetraspanin CD63 antigen Serum IgG POC-ICTs had a sensitivity of 89% and a specificity of 100%. Peptide Smp_150390.1 (216-230) serum based IgG ELISA had the best diagnostic performance for S. mansoni with a sensitivity of 96.15% and a specificity of 100%. Peptides were reported to demonstrate good to excellent diagnostic performances. S. mansoni multi-peptide chimeric protein further improved the diagnostic accuracy of synthetic peptides. Together with the advantages associated with urine sampling technique, we recommend development of multi-peptide chimeric proteins urine based point of care tools.
Topics: Animals; Schistosoma haematobium; Schistosoma mansoni; Tetraspanin 30; Peptides; Blood Group Antigens; Recombinant Proteins; Recombinant Fusion Proteins; Immunoglobulin G
PubMed: 36862712
DOI: 10.1371/journal.pone.0282233 -
PLoS Medicine Aug 2011Serological (antibody detection) tests for tuberculosis (TB) are widely used in developing countries. As part of a World Health Organization policy process, we performed... (Meta-Analysis)
Meta-Analysis Review
BACKGROUND
Serological (antibody detection) tests for tuberculosis (TB) are widely used in developing countries. As part of a World Health Organization policy process, we performed an updated systematic review to assess the diagnostic accuracy of commercial serological tests for pulmonary and extrapulmonary TB with a focus on the relevance of these tests in low- and middle-income countries.
METHODS AND FINDINGS
We used methods recommended by the Cochrane Collaboration and GRADE approach for rating quality of evidence. In a previous review, we searched multiple databases for papers published from 1 January 1990 to 30 May 2006, and in this update, we add additional papers published from that period until 29 June 2010. We prespecified subgroups to address heterogeneity and summarized test performance using bivariate random effects meta-analysis. For pulmonary TB, we included 67 studies (48% from low- and middle-income countries) with 5,147 participants. For all tests, estimates were variable for sensitivity (0% to 100%) and specificity (31% to 100%). For anda-TB IgG, the only test with enough studies for meta-analysis, pooled sensitivity was 76% (95% CI 63%-87%) in smear-positive (seven studies) and 59% (95% CI 10%-96%) in smear-negative (four studies) patients; pooled specificities were 92% (95% CI 74%-98%) and 91% (95% CI 79%-96%), respectively. Compared with ELISA (pooled sensitivity 60% [95% CI 6%-65%]; pooled specificity 98% [95% CI 96%-99%]), immunochromatographic tests yielded lower pooled sensitivity (53%, 95% CI 42%-64%) and comparable pooled specificity (98%, 95% CI 94%-99%). For extrapulmonary TB, we included 25 studies (40% from low- and middle-income countries) with 1,809 participants. For all tests, estimates were variable for sensitivity (0% to 100%) and specificity (59% to 100%). Overall, quality of evidence was graded very low for studies of pulmonary and extrapulmonary TB.
CONCLUSIONS
Despite expansion of the literature since 2006, commercial serological tests continue to produce inconsistent and imprecise estimates of sensitivity and specificity. Quality of evidence remains very low. These data informed a recently published World Health Organization policy statement against serological tests. Please see later in the article for the Editors' Summary.
Topics: Antibodies, Bacterial; Antigens, Bacterial; Bias; Developing Countries; Enzyme-Linked Immunosorbent Assay; Humans; Mycobacterium tuberculosis; Sensitivity and Specificity; Serologic Tests; Tuberculosis; Tuberculosis, Pulmonary
PubMed: 21857806
DOI: 10.1371/journal.pmed.1001062 -
International Journal of Rheumatic... May 2021To evaluate the diagnostic value of anti-citrullinated α-enolase peptide 1 (anti-CEP 1) antibody in patients with rheumatoid arthritis (RA) by conducting a systematic... (Meta-Analysis)
Meta-Analysis
AIM
To evaluate the diagnostic value of anti-citrullinated α-enolase peptide 1 (anti-CEP 1) antibody in patients with rheumatoid arthritis (RA) by conducting a systematic review and meta-analysis.
METHODS
The PubMed, Web of Science, Embase, Scopus, and Cochrane Library databases were searched for relevant studies published until September 23, 2020. A bivariate mixed-effects model was used to calculate the diagnostic indices from primary data of eligible studies. We performed meta-regression and subgroup analysis to explore the sources of heterogeneity.
RESULTS
Twenty-four articles, with a total of 17 380 patients with RA and 7505 control participants, met the criteria for inclusion in the meta-analysis. The pooled sensitivity, specificity, and positive and negative likelihood ratios for the anti-CEP 1 antibody were 44% (95% CI: 38%-51%), 97% (95% CI: 96%-98%), and 14.81 (95% CI: 10.66-20.57) and 0.57 (95% CI: 0.52-0.64), respectively. The pooled positive and negative predictive values were 0.96 (95% CI: 0.95-0.97) and 0.53 (95% CI: 0.43-0.63), respectively. The area under the summary receiver operating characteristic curve was 0.86. Meta-regression indicated that the anti-CEP 1 antibody detection method may be a source of heterogeneity. The subgroup analysis of the group in which the anti-CEP 1 antibody was detected by using a commercial enzyme-linked immunosorbent assay (ELISA) kit had a sensitivity of 59% (95% CI: 50%-68%) and a specificity of 93% (95% CI: 85%-97%).
CONCLUSIONS
The anti-CEP 1 antibody had moderate RA diagnostic value with relatively low sensitivity and high specificity. An ELISA may increase the RA diagnostic sensitivity.
Topics: Anti-Citrullinated Protein Antibodies; Antibodies; Arthritis, Rheumatoid; Biomarkers, Tumor; DNA-Binding Proteins; Enzyme-Linked Immunosorbent Assay; Genetic Predisposition to Disease; Humans; Peptides, Cyclic; Phosphopyruvate Hydratase; Sensitivity and Specificity; Tumor Suppressor Proteins
PubMed: 33713557
DOI: 10.1111/1756-185X.14093 -
Orthopaedic Surgery Nov 2022The current diagnostic criteria for periprosthetic joint infection (PJI) are diverse and controversial, leading to delayed diagnosis. This study aimed to evaluate and... (Meta-Analysis)
Meta-Analysis Review
OBJECTIVE
The current diagnostic criteria for periprosthetic joint infection (PJI) are diverse and controversial, leading to delayed diagnosis. This study aimed to evaluate and unify their diagnostic accuracy and the threshold selection of serum and synovial routine tests for PJI at an early stage.
METHODS
We searched the MEDLINE and Embase databases for retrospective or prospective studies which reported preoperative-available assays (serum, synovial, or culture tests) for the diagnosis of chronic PJI among inflammatory arthritis (IA) or non-IA populations from January 1, 2000 to June 30, 2022. Threshold effective analysis was performed on synovial polymorphonuclear neutrophils (PMN%), synovial white blood cell (WBC), serum C-reactive protein (CRP), and erythrocyte sedimentation rate (ESR) to find the relevant cut-offs.
RESULTS
Two hundred and sixteen studies and information from 45,316 individuals were included in the final analysis. Synovial laboratory-based α-defensin and calprotectin had the best comprehensive sensitivity (0.91 [0.86-0.94], 0.95 [0.88-0.98]) and specificity (0.96 [0.94-0.97], 0.95 [0.89-0.98]) values. According to the threshold effect analysis, the recommended cut-offs are 70% (sensitivity 0.89 [0.85-0.92], specificity 0.90 [0.87-0.93]), 4100/μL (sensitivity 0.90 [0.87-0.93], specificity 0.97 [0.93-0.98]), 13.5 mg/L (sensitivity 0.84 [0.78-0.89], specificity 0.83 [0.73-0.89]), and 30 mm/h (sensitivity 0.79 [0.74-0.83], specificity 0.78 [0.72-0.83]) for synovial PMN%, synovial WBC, serum CRP, and ESR, respectively, and tests seem to be more reliable among non-IA patients.
CONCLUSIONS
The laboratory-based synovial α-defensin and synovial calprotectin are the two best independent preoperative diagnostic tests for PJI. A cut off of 70% for synovial PMN% and tighter cut-offs for synovial WBC and serum CRP could have a better diagnostic accuracy for non-IA patients with chronic PJI.
Topics: Humans; alpha-Defensins; Arthritis, Infectious; Arthroplasty, Replacement, Hip; C-Reactive Protein; Diagnostic Tests, Routine; Leukocyte L1 Antigen Complex; Prospective Studies; Prosthesis-Related Infections; Retrospective Studies; Synovial Fluid
PubMed: 36181336
DOI: 10.1111/os.13500