BMJ (Clinical Research Ed.) Nov 2017To compare the efficacy, safety, and cost effectiveness of direct acting oral anticoagulants (DOACs) for patients with atrial fibrillation. Systematic review, network... (Meta-Analysis)
Meta-Analysis Review
To compare the efficacy, safety, and cost effectiveness of direct acting oral anticoagulants (DOACs) for patients with atrial fibrillation. Systematic review, network meta-analysis, and cost effectiveness analysis. Medline, PreMedline, Embase, and The Cochrane Library. Published randomised trials evaluating the use of a DOAC, vitamin K antagonist, or antiplatelet drug for prevention of stroke in patients with atrial fibrillation. 23 randomised trials involving 94 656 patients were analysed: 13 compared a DOAC with warfarin dosed to achieve a target INR of 2.0-3.0. Apixaban 5 mg twice daily (odds ratio 0.79, 95% confidence interval 0.66 to 0.94), dabigatran 150 mg twice daily (0.65, 0.52 to 0.81), edoxaban 60 mg once daily (0.86, 0.74 to 1.01), and rivaroxaban 20 mg once daily (0.88, 0.74 to 1.03) reduced the risk of stroke or systemic embolism compared with warfarin. The risk of stroke or systemic embolism was higher with edoxaban 60 mg once daily (1.33, 1.02 to 1.75) and rivaroxaban 20 mg once daily (1.35, 1.03 to 1.78) than with dabigatran 150 mg twice daily. The risk of all-cause mortality was lower with all DOACs than with warfarin. Apixaban 5 mg twice daily (0.71, 0.61 to 0.81), dabigatran 110 mg twice daily (0.80, 0.69 to 0.93), edoxaban 30 mg once daily (0.46, 0.40 to 0.54), and edoxaban 60 mg once daily (0.78, 0.69 to 0.90) reduced the risk of major bleeding compared with warfarin. The risk of major bleeding was higher with dabigatran 150 mg twice daily than apixaban 5 mg twice daily (1.33, 1.09 to 1.62), rivaroxaban 20 mg twice daily than apixaban 5 mg twice daily (1.45, 1.19 to 1.78), and rivaroxaban 20 mg twice daily than edoxaban 60 mg once daily (1.31, 1.07 to 1.59). The risk of intracranial bleeding was substantially lower for most DOACs compared with warfarin, whereas the risk of gastrointestinal bleeding was higher with some DOACs than warfarin. Apixaban 5 mg twice daily was ranked the highest for most outcomes, and was cost effective compared with warfarin. The network meta-analysis informs the choice of DOACs for prevention of stroke in patients with atrial fibrillation. Several DOACs are of net benefit compared with warfarin. A trial directly comparing DOACs would overcome the need for indirect comparisons to be made through network meta-analysis. PROSPERO CRD 42013005324.
Topics: Administration, Oral; Anticoagulants; Atrial Fibrillation; Cost-Benefit Analysis; Drug Costs; Hemorrhage; Humans; Quality-Adjusted Life Years; Randomized Controlled Trials as Topic; Stroke
PubMed: 29183961
DOI: 10.1136/bmj.j5058 -
Journal of Medical Internet Research Aug 2021Significant morbidity, mortality, and financial burden are associated with cardiac rhythm abnormalities. Conventional investigative tools are often unsuccessful in... (Meta-Analysis)
Meta-Analysis Review
BACKGROUND
Significant morbidity, mortality, and financial burden are associated with cardiac rhythm abnormalities. Conventional investigative tools are often unsuccessful in detecting cardiac arrhythmias because of their episodic nature. Smartwatches have gained popularity in recent years as a health tool for the detection of cardiac rhythms.
OBJECTIVE
This study aims to systematically review and meta-analyze the diagnostic accuracy of smartwatches in the detection of cardiac arrhythmias.
METHODS
A systematic literature search of the Embase, MEDLINE, and Cochrane Library databases was performed in accordance with the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines to identify studies reporting the use of a smartwatch for the detection of cardiac arrhythmia. Summary estimates of sensitivity, specificity, and area under the curve were attempted using a bivariate model for the diagnostic meta-analysis. Studies were examined for quality using the Quality Assessment of Diagnostic Accuracy Studies 2 tool.
RESULTS
A total of 18 studies examining atrial fibrillation detection, bradyarrhythmias and tachyarrhythmias, and premature contractions were analyzed, measuring diagnostic accuracy in 424,371 subjects in total. The signals analyzed by smartwatches were based on photoplethysmography. The overall sensitivity, specificity, and accuracy of smartwatches for detecting cardiac arrhythmias were 100% (95% CI 0.99-1.00), 95% (95% CI 0.93-0.97), and 97% (95% CI 0.96-0.99), respectively. The pooled positive predictive value and negative predictive value for detecting cardiac arrhythmias were 85% (95% CI 0.79-0.90) and 100% (95% CI 1.0-1.0), respectively.
CONCLUSIONS
This review demonstrates the evolving field of digital disease detection. The current diagnostic accuracy of smartwatch technology for the detection of cardiac arrhythmias is high. Although the innovative drive of digital devices in health care will continue to gain momentum toward screening, the process of accurate evidence accrual and regulatory standards ready to accept their introduction is strongly needed.
TRIAL REGISTRATION
PROSPERO International Prospective Register of Systematic Reviews CRD42020213237; https://www.crd.york.ac.uk/prospero/display_record.php?RecordID=213237.
Topics: Atrial Fibrillation; Humans; Mass Screening; Photoplethysmography; Predictive Value of Tests
PubMed: 34448706
DOI: 10.2196/28974 -
Annales Pharmaceutiques Francaises Sep 2022Beta-blockers have long been successfully used for the treatment of both supraventricular and ventricular arrhythmias. However, differences exist between their chemical... (Review)
Review
OBJECTIVES
Beta-blockers have long been successfully used for the treatment of both supraventricular and ventricular arrhythmias. However, differences exist between their chemical structure, pharmacokinetic and pharmacodynamic properties (absorption, bioavailability, metabolism, hydrophilic or lipophilic character, selective or non-selective nature, the presence or absence of intrinsic sympathomimetic activity), which may confer different antiarrhythmic properties to different beta-blockers. The aim of this study was to analyze the current existing evidence for bisoprolol for the treatment of both supraventricular and ventricular arrhythmias.
MATERIAL AND METHODS
Using the keywords "bisoprolol" and "arrhythmias" or "atrial fibrillation" or "ventricular tachycardia" or "premature ventricular complexes" or "ventricular fibrillation", the Medline database was searched for articles in English or French until April 2020 assessing the role of bisoprolol in the treatment of arrhythmias. Data was then analyzed according to the type of arrhythmia treated and the quality of evidence using the GRADE approach.
RESULTS
A total of 325 studies were identified, of which 28 were considered relevant to the current topic. Among these studies, 19 assessed the role of bisoprolol for the treatment of supraventricular arrhythmias, 8 its role in treating ventricular arrhythmias and 1 its role in supraventricular and ventricular arrhythmias. The quality of evidence varied from low (7 studies) to high (5 studies).
CONCLUSION
Current evidence exists supporting the use of bisoprolol for the treatment of supraventricular arrhythmias, especially for rate control during atrial fibrillation. Evidence also exists for its efficacy in the treatment of ventricular arrhythmias, both in primary and in secondary prevention.
Topics: Adrenergic beta-Antagonists; Atrial Fibrillation; Bisoprolol; Humans
PubMed: 35093388
DOI: 10.1016/j.pharma.2022.01.007 -
European Journal of Preventive... Sep 2017Background In contemporary atrial fibrillation trials most deaths are cardiac related, whereas stroke and bleeding represent only a small subset of deaths. We aimed to... (Meta-Analysis)
Meta-Analysis Review
Background In contemporary atrial fibrillation trials most deaths are cardiac related, whereas stroke and bleeding represent only a small subset of deaths. We aimed to evaluate the long-term risk of cardiac events and all-cause mortality in individuals with atrial fibrillation compared to no atrial fibrillation. Design A systematic review and meta-analysis of studies published between 1 January 2006 and 21 October 2016. Methods Four databases were searched. Studies had follow-up of at least 500 stable patients for either cardiac endpoints or all-cause mortality for 12 months or longer. Publication bias was evaluated and random effects models were used to synthesise the results. Heterogeneity between studies was examined by subgroup and meta-regression analyses. Results A total of 15 cohort studies was included. Analyses indicated that atrial fibrillation was associated with an increased risk of myocardial infarction (relative risk (RR) 1.54, 95% confidence interval (CI) 1.26-1.85), all-cause mortality (RR 1.95, 95% CI 1.50-2.54) and heart failure (RR 4.62, 95% CI 3.13-6.83). Coronary heart disease at baseline was associated with a reduced risk of myocardial infarction and explained 57% of the heterogeneity. A prospective cohort design accounted for 25% of all-cause mortality heterogeneity. Due to there being fewer than 10 studies, sources of heterogeneity were inconclusive for heart failure. Conclusions Atrial fibrillation seems to be associated with an increased risk of subsequent myocardial infarction in patients without coronary heart disease and an increased risk of, all-cause mortality and heart failure in patients with and without coronary heart disease.
Topics: Aged; Atrial Fibrillation; Cause of Death; Coronary Disease; Female; Heart Failure; Humans; Incidence; Male; Middle Aged; Myocardial Infarction; Odds Ratio; Prevalence; Prognosis; Risk Assessment; Risk Factors; Time Factors
PubMed: 28617620
DOI: 10.1177/2047487317715769 -
JAMA May 2018Vasopressin is an alternative to catecholamine vasopressors for patients with distributive shock-a condition due to excessive vasodilation, most frequently from severe... (Comparative Study)
Comparative Study Meta-Analysis Review
Association of Vasopressin Plus Catecholamine Vasopressors vs Catecholamines Alone With Atrial Fibrillation in Patients With Distributive Shock: A Systematic Review and Meta-analysis.
IMPORTANCE
Vasopressin is an alternative to catecholamine vasopressors for patients with distributive shock-a condition due to excessive vasodilation, most frequently from severe infection. Blood pressure support with a noncatecholamine vasopressor may reduce stimulation of adrenergic receptors and decrease myocardial oxygen demand. Atrial fibrillation is common with catecholamines and is associated with adverse events, including mortality and increased length of stay (LOS).
OBJECTIVES
To determine whether treatment with vasopressin + catecholamine vasopressors compared with catecholamine vasopressors alone was associated with reductions in the risk of adverse events.
DATA SOURCES
MEDLINE, EMBASE, and CENTRAL were searched from inception to February 2018. Experts were asked and meta-registries searched to identify ongoing trials.
STUDY SELECTION
Pairs of reviewers identified randomized clinical trials comparing vasopressin in combination with catecholamine vasopressors to catecholamines alone for patients with distributive shock.
DATA EXTRACTION AND SYNTHESIS
Two reviewers abstracted data independently. A random-effects model was used to combine data.
MAIN OUTCOMES AND MEASURES
The primary outcome was atrial fibrillation. Other outcomes included mortality, requirement for renal replacement therapy (RRT), myocardial injury, ventricular arrhythmia, stroke, and LOS in the intensive care unit and hospital. Measures of association are reported as risk ratios (RRs) for clinical outcomes and mean differences for LOS.
RESULTS
Twenty-three randomized clinical trials were identified (3088 patients; mean age, 61.1 years [14.2]; women, 45.3%). High-quality evidence supported a lower risk of atrial fibrillation associated with vasopressin treatment (RR, 0.77 [95% CI, 0.67 to 0.88]; risk difference [RD], -0.06 [95% CI, -0.13 to 0.01]). For mortality, the overall RR estimate was 0.89 (95% CI, 0.82 to 0.97; RD, -0.04 [95% CI, -0.07 to 0.00]); however, when limited to trials at low risk of bias, the RR estimate was 0.96 (95% CI, 0.84 to 1.11). The overall RR estimate for RRT was 0.74 (95% CI, 0.51 to 1.08; RD, -0.07 [95% CI, -0.12 to -0.01]). However, in an analysis limited to trials at low risk of bias, RR was 0.70 (95% CI, 0.53 to 0.92, P for interaction = .77). There were no significant differences in the pooled risks for other outcomes.
CONCLUSIONS AND RELEVANCE
In this systematic review and meta-analysis, the addition of vasopressin to catecholamine vasopressors compared with catecholamines alone was associated with a lower risk of atrial fibrillation. Findings for secondary outcomes varied.
Topics: Atrial Fibrillation; Catecholamines; Drug Therapy, Combination; Female; Humans; Length of Stay; Male; Publication Bias; Shock; Vasoconstrictor Agents; Vasopressins
PubMed: 29801010
DOI: 10.1001/jama.2018.4528 -
Ageing Research Reviews Aug 2022Frailty is a clinical syndrome characterized by a reduced physiologic reserve, increased vulnerability to stressors and an increased risk of adverse outcomes. People... (Meta-Analysis)
Meta-Analysis Review
Frailty is a clinical syndrome characterized by a reduced physiologic reserve, increased vulnerability to stressors and an increased risk of adverse outcomes. People with atrial fibrillation (AF) are often burdened by frailty due to biological, clinical, and social factors. The prevalence of frailty, its management and association with major outcomes in AF patients are still not well quantified. We systematically searched PubMed and EMBASE, from inception to September 13th, 2021, for studies reporting the prevalence of frailty in AF patients. The study was registered in PROSPERO (CRD42021235854). 33 studies were included in the systematic review (n = 1,187,651 patients). The frailty pooled prevalence was 39.7 % (95 %CI=29.9 %-50.5 %, I =100 %), while meta-regression analyses showed it is influenced by age, history of stroke, and geographical location. Meta-regression analyses showed that OAC prescription was influenced by study-level mean age, baseline thromboembolic risk, and study setting. Frail AF patients were associated with a higher risk of all-cause death (OR=5.56, 95 %CI=3.46-8.94), ischemic stroke (OR=1.59, 95 %CI=1.00-2.52), and bleeding (OR=1.64, 95 %CI=1.11-2.41), when compared to robust individuals. In this systematic review and meta-analysis, the prevalence of frailty was high in patients with AF. Frailty may influence the prognosis and management of AF patients, thus requiring person-tailored interventions in a holistic or integrated approach to AF care.
Topics: Anticoagulants; Atrial Fibrillation; Frailty; Humans; Prevalence; Risk Factors; Stroke
PubMed: 35659945
DOI: 10.1016/j.arr.2022.101652 -
Academic Emergency Medicine : Official... Feb 2023The objective was to evaluate the comparative effectiveness and safety of pharmacological and nonpharmacological management options for atrial fibrillation/atrial... (Meta-Analysis)
Meta-Analysis Review
OBJECTIVE
The objective was to evaluate the comparative effectiveness and safety of pharmacological and nonpharmacological management options for atrial fibrillation/atrial flutter with rapid ventricular response (AFRVR) in patients with acute decompensated heart failure (ADHF) in the acute care setting.
METHODS
This study was a systematic review of observational studies or randomized clinical trials (RCT) of adult patients with AFRVR and concomitant ADHF in the emergency department (ED), intensive care unit, or step-down unit. The primary effectiveness outcome was successful rate or rhythm control. Safety outcomes were adverse events, such as symptomatic hypotension and venous thromboembolism.
RESULTS
A total of 6577 unique articles were identified. Five studies met inclusion criteria: one RCT in the inpatient setting and four retrospective studies, two in the ED and the other three in the inpatient setting. In the RCT of diltiazem versus placebo, 22 patients (100%) in the treatment group had a therapeutic response compared to 0/15 (0%) in the placebo group, with no significant safety differences between the two groups. For three of the observational studies, data were limited. One observation study showed no difference between metoprolol and diltiazem for successful rate control, but worsening heart failure symptoms occurred more frequently in those receiving diltiazem compared to metoprolol (19 patients [33%] vs. 10 patients [15%], p = 0.019). A single study included electrical cardioversion (one patient exposed with failure to convert to sinus rhythm) as nonpharmacological management. The overall risk of bias for included studies ranged from serious to critical. Missing data and heterogeneity of definitions for effectiveness and safety outcomes precluded the combination of results for quantitative meta-analysis.
CONCLUSIONS
High-level evidence to inform clinical decision making regarding effective and safe management of AFRVR in patients with ADHF in the acute care setting is lacking.
Topics: Adult; Humans; Atrial Fibrillation; Atrial Flutter; Diltiazem; Metoprolol; Anti-Arrhythmia Agents; Heart Failure; Randomized Controlled Trials as Topic; Observational Studies as Topic
PubMed: 36326565
DOI: 10.1111/acem.14618 -
JAMA Cardiology Jun 2021Early rhythm control of atrial fibrillation (AF) with either antiarrhythmic drugs (AADs) or catheter ablation has been reported to improve cardiovascular outcomes... (Meta-Analysis)
Meta-Analysis
IMPORTANCE
Early rhythm control of atrial fibrillation (AF) with either antiarrhythmic drugs (AADs) or catheter ablation has been reported to improve cardiovascular outcomes compared with usual care; however, the optimal therapeutic modality to achieve early rhythm control is unclear.
OBJECTIVE
To assess the safety and efficacy of AF ablation as first-line therapy when compared with AADs in patients with paroxysmal AF.
DATA SOURCES
PubMed/MEDLINE, Scopus, Google Scholar, and various major scientific conference sessions from January 1, 2000, through November 23, 2020.
STUDY SELECTION
Randomized clinical trials (RCTs) published in English that had at least 12 months of follow-up and compared clinical outcomes of ablation vs AADs as first-line therapy in adults with AF. The quality of individual studies was assessed using the Cochrane risk of bias tool. Six RCTs met inclusion criteria, including 1212 patients.
DATA EXTRACTION AND SYNTHESIS
Two investigators independently extracted data. Reporting was performed in compliance with the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-analysis) guidelines. Analysis was performed using a random-effects model with the Mantel-Haenszel method, and results are presented as 95% CIs.
MAIN OUTCOMES AND MEASURES
Main outcomes were safety and efficacy of AF ablation as first-line therapy when compared with AADs. Trials were evaluated as having low risk of selection and attrition biases, high risk of performance bias, and with unclear risk for detection biases due to unblinding and open-label designs.
RESULTS
A total of 6 RCTs involving 1212 patients with AF were included (609 were randomized to AF ablation and 603 to drug therapy; mean [SD] age, 56 [11] years). Compared with AADs, catheter ablation use was associated with reductions in recurrent atrial arrhythmia (32.3% vs 53%; risk ratio [RR], 0.62; 95% CI, 0.51-0.74; P < .001; I2 = 40%), with a number needed to treat with ablation to prevent 1 arrhythmia of 5. Use of ablation was also associated with reduced symptomatic atrial arrhythmia (11.8% vs 26.4%; RR, 0.44; 95% CI, 0.27-0.72; P = .001; I2 = 54%) and hospitalization (5.6% vs 18.7%; RR, 0.32; 95% CI, 0.19-0.53; P < .001) with no significant difference in serious adverse events between the groups (4.2% vs 2.8%; RR, 1.52; 95% CI, 0.81-2.85; P = .19).
CONCLUSIONS AND RELEVANCE
In this meta-analysis of randomized clinical trials including first-line therapy of patients with paroxysmal AF, catheter ablation compared with antiarrhythmic drugs was associated with reductions in recurrence of atrial arrhythmias and hospitalizations, with no difference in major adverse events.
Topics: Anti-Arrhythmia Agents; Atrial Fibrillation; Catheter Ablation; Hospitalization; Humans; Randomized Controlled Trials as Topic
PubMed: 33909022
DOI: 10.1001/jamacardio.2021.0852 -
Arquivos Brasileiros de Cardiologia Jul 2022Catheter ablation is a well-established therapy for rhythm control in patients who are refractory or intolerant to anti-arrhythmic drugs (AAD). Less is known about the... (Meta-Analysis)
Meta-Analysis
BACKGROUND
Catheter ablation is a well-established therapy for rhythm control in patients who are refractory or intolerant to anti-arrhythmic drugs (AAD). Less is known about the efficacy of catheter ablation compared with AAD as a first-line strategy for rhythm control in atrial fibrillation (AF).
OBJECTIVES
We aimed to perform a systematic review and meta-analysis of catheter ablation vs. AAD in patients naïve to prior rhythm control therapies.
METHODS
PubMed, EMBASE, and Cochrane databases were searched for randomized controlled trials that compared catheter ablation to AAD for initial rhythm control in symptomatic AF and reported the outcomes of (1) recurrent atrial tachyarrhythmias (ATs); (2) symptomatic AF; (3) hospitalizations; and (4) symptomatic bradycardia. Heterogeneity was examined with I2statistics. P values of < 0.05 were considered statistically significant.
RESULTS
We included five trials with 994 patients, of whom 502 (50.5%) underwent catheter ablation. Mean follow-up ranged from one to five years. Recurrences of AT (OR 0.36; 95% CI 0.25-0.52; p<0.001) and symptomatic AF (OR 0.32; 95% CI 0.18-0.57; p<0.001), and hospitalizations (OR 0.25; 95% CI 0.15-0.42; p<0.001) were significantly less frequent in patients treated with catheter ablation compared with AAD. Symptomatic bradycardia was not significantly different between groups (OR 0.55; 95% CI 0.18-1.65; p=0.28). Significant pericardial effusions or tamponade occurred in eight of 464 (1.7%) patients in the catheter ablation group.
CONCLUSION
These findings suggest that catheter ablation has superior efficacy to AAD as an initial rhythm control strategy in patients with symptomatic AF.
Topics: Anti-Arrhythmia Agents; Atrial Fibrillation; Catheter Ablation; Heart Atria; Humans; Recurrence; Treatment Outcome
PubMed: 35830118
DOI: 10.36660/abc.20210477 -
Archives of Cardiovascular Diseases Jan 2021Recently, smart devices have been used for medical purposes, particularly to screen for atrial fibrillation. However, current data on the diagnostic performance of these... (Meta-Analysis)
Meta-Analysis
BACKGROUND
Recently, smart devices have been used for medical purposes, particularly to screen for atrial fibrillation. However, current data on the diagnostic performance of these devices are scarce.
AIMS
We performed a systemic review and meta-analysis to assess the accuracy of atrial fibrillation diagnosis by smart gadgets/wearable devices.
METHODS
We comprehensively searched the MEDLINE, EMBASE and Cochrane databases for all works since the inception of each database until January 2020. Included in this review were published observational studies of the diagnostic accuracy of smartphones or smartwatches in detecting atrial fibrillation. We calculated the area under the summary receiver operating characteristic curves and pooled sensitivities and specificities.
RESULTS
Participants in our study were from the general population or were patients with underlying atrial fibrillation. In the overall analyses, the areas under the summary receiver operating characteristic curves were 0.96 and 0.94 for smartphones and smartwatches, respectively. Smartphones had a sensitivity of 94% and a specificity of 96%, and smartwatches showed similar diagnostic accuracy, with a specificity of 94% and a sensitivity of 93%. In subgroup analyses, we found no difference in diagnostic accuracy between photoplethysmography and single-lead electrocardiography.
CONCLUSIONS
This study suggests that smart devices have similar diagnostic accuracies. Regarding atrial fibrillation detection methods, there was also no difference between photoplethysmography and single-lead electrocardiography. However, further studies are warranted to determine their clinical implications in atrial fibrillation management.
Topics: Action Potentials; Aged; Aged, 80 and over; Atrial Fibrillation; Female; Heart Conduction System; Heart Rate; Humans; Male; Middle Aged; Mobile Applications; Predictive Value of Tests; Reproducibility of Results; Smartphone; Telemetry; Wearable Electronic Devices; Wireless Technology
PubMed: 32921618
DOI: 10.1016/j.acvd.2020.05.015