Global Heart 2023Bystander cardiopulmonary resuscitation (CPR) and using an automated external defibrillator (AED) can improve out-of-hospital cardiac arrest survival. However, bystander...
Factors and Barriers on Cardiopulmonary Resuscitation and Automated External Defibrillator Willingness to Use among the Community: A 2016-2021 Systematic Review and Data Synthesis.
BACKGROUND
Bystander cardiopulmonary resuscitation (CPR) and using an automated external defibrillator (AED) can improve out-of-hospital cardiac arrest survival. However, bystander CPR and AED rates remained consistently low. The goal of this systematic review was to assess factors influencing community willingness to perform CPR and use an AED for out-of-hospital cardiac arrest survival (OHCA) victims, as well as its barriers.
METHODS
The review processes (PROSPERO: CRD42021257851) were conducted following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) review protocol; formulation of review questions; systematic search strategy based on identification, screening, and eligibility using established databases including Scopus, Web of Science, and Medline Complete via EBSCOhost; quality appraisal; and data extraction and analysis. There is identification of full-text journal articles that were published between 2016 and 2021 and written in English.
RESULTS
Of the final 13 articles, there are six identified factors associated with willingness to perform CPR and use an AED, including socio-demographics, training, attitudes, perceived norms, self-efficacy, and legal obligation. Younger age, men, higher level of education, employed, married, having trained in CPR and AED in the previous 5 years, having received CPR education on four or more occasions, having a positive attitude and perception toward CPR and AED, having confidence to perform CPR and to apply an AED, and legal liability protection under emergency medical service law were reasons why one would be more likely to indicate a willingness to perform CPR and use an AED. The most reported barriers were fear of litigation and injuring a victim.
CONCLUSIONS
There is a need to empower all the contributing factors and reduce the barrier by emphasizing the importance of CPR and AEDs. The role played by all stakeholders should be strengthened to ensure the success of intervention programs, and indirectly, that can reduce morbidity and mortality among the community from OHCA.
Topics: Child, Preschool; Humans; Male; Cardiopulmonary Resuscitation; Databases, Factual; Educational Status; Emergency Medical Services; Out-of-Hospital Cardiac Arrest
PubMed: 37649652
DOI: 10.5334/gh.1255 -
Cureus Aug 2023Sudden cardiac death (SCD) is a condition that accounts for a high percentage of cardiovascular fatalities, with ventricular tachyarrhythmias being the most common... (Review)
Review
Sudden cardiac death (SCD) is a condition that accounts for a high percentage of cardiovascular fatalities, with ventricular tachyarrhythmias being the most common cause. There are signs and symptoms of SCD that occur spontaneously without any warning and are deadly. Despite preventative efforts focusing on the use of subcutaneous implanted cardioverter defibrillators (S-ICD) in the highest-risk population categories, a high number of SCDs occur in the normal population and in people who do not have a documented cardiac condition. Therefore, primary prevention for SCD should be a more viable strategy for the general population, considering measures in the form of preventive medicine such as knowing more about any genetic predisposition, family history of any fatal arrhythmia, continuous surveillance after any syncope with unknown causes, etc. However, little data about SCD risk factors are known in comparison with other well-known diseases like ischemic heart disease and stroke. In search of medical databases for relevant medical literature, we looked at PubMed/Medline, the Cochrane Library, and Google Scholar. Thirteen publications were discovered after the papers were located, assessed, and qualifying criteria were applied. The finished articles were done to give an overview of SCD. Some others have shown that the major predisposition for SCD is related to the male gender, which increases the incidence if they have a family history of SCD. We described the importance of obstructive sleep apnea (OSA) as a comorbid condition. Patients with S-ICD and young athletes with a history of ventricular arrhythmia showed us that the predisposition for SCD can be higher than in the normal population. Based on the above, we concluded that more study is required to establish the most important approach for each of the risk factors mentioned in this systematic review in order to apply them in daily practice and have more knowledge about how to apply preventive and therapeutic medicine to the population at risk and the ones that already develop the disease.
PubMed: 37664320
DOI: 10.7759/cureus.42859 -
Journal of Clinical Medicine May 2023Subcutaneous implantable cardioverter defibrillators (S-ICDs) have emerged in recent years as a valid alternative to traditional transvenous ICDs (TV-ICDs). Therefore,... (Review)
Review
BACKGROUND AND PURPOSE
Subcutaneous implantable cardioverter defibrillators (S-ICDs) have emerged in recent years as a valid alternative to traditional transvenous ICDs (TV-ICDs). Therefore, the number of S-ICD implantations is rising, leading to a consequent increase in S-ICD-related complications sometimes requiring complete device removal. Thus, the aim of this systematic review is to gather all the available literature on S-ICD lead extraction (SLE), with particular reference to the type of indication, techniques, complications and success rate.
METHODS
Studies were identified by searching electronic databases (Medline via PubMed, Scopus and Web of Science) from inception to 21 November 2022. The search strategy adopted was developed using the following key words: subcutaneous, S-ICD, defibrillator, ICD, extraction, explantation. Studies were included if they met both of the following criteria: (1) inclusion of patients with S-ICD; (2) inclusion of patients who underwent SLE.
RESULTS
Our literature search identified 238 references. Based on the abstract evaluation, 38 of these citations were considered potentially eligible for inclusion, and their full texts were analyzed. We excluded 8 of these studies because no SLE was performed. Eventually, 30 studies were included, with 207 patients who underwent SLE. Overall, the majority of SLEs were performed for non-infective causes (59.90%). Infection of the device (affecting either the lead or the pocket) was the cause of SLE in 38.65% of cases. Indication data were not available in 3/207 cases. The mean dwelling time was 14 months. SLEs were performed using manual traction or with the aid of a tool designed for transvenous lead extraction (TLE), including either a rotational or non-powered mechanical dilator sheath.
CONCLUSIONS
SLE is performed mainly for non-infective causes. Techniques vary greatly across different studies. Dedicated tools for SLE might be developed in the future and standard approaches should be defined. In the meantime, authors are encouraged to share their experience and data to further refine the existing variegated approaches.
PubMed: 37297905
DOI: 10.3390/jcm12113710 -
Journal of Arrhythmia Feb 2018The evidence to support implantable cardioverter defibrillator (ICD) in subjects with nonischemic cardiomyopathy (NICM) for primary prevention of sudden cardiac death... (Review)
Review
The evidence to support implantable cardioverter defibrillator (ICD) in subjects with nonischemic cardiomyopathy (NICM) for primary prevention of sudden cardiac death (SCD) is not robust. This meta-analysis intends to assess the impact of routine ICD implantation for primary prevention of mortality due to SCD in NICM based on all the published randomized clinical trials (RCTs). Six RCTs were selected using PubMed/Medline, EMBASE, and CENTRAL from inception to December 2016. Outcomes were calculated as random-effects relative risk (RR) and risk difference (RD) with 95% confidence interval (CI). Patients were randomized to ICD arm and control arm (usual care, medical treatment, and anti-arrhythmic drugs). ICD significantly reduced all-cause mortality in NICM patients (RR, 0.74, 95% CI, 0.56-0.97, = .03, I = 40). Mortality benefit was achieved due to a significant reduction in sudden cardiac death (SCD) (RR, 0.47, 95% CI, 0.30-0.73, < .001, I = 0). There were no statistical differences between two groups with regard to risk of noncardiac mortality, non-SCD, cardiac arrest, cardiac transplant, sustained ventricular tachycardia (VT), and VT requiring medical treatment. Our results support efficacy of ICDs at reducing all-cause mortality due to a reduction in SCD.
PubMed: 29721108
DOI: 10.1002/joa3.12017 -
Efficacy and safety of the subcutaneous implantable cardioverter defibrillator: a systematic review.Heart (British Cardiac Society) Sep 2017Subcutaneous implantable cardioverter defibrillators (S-ICDs) are considered an alternative to conventional transvenous ICDs (TV-ICDs) in patients not requiring pacing. (Review)
Review
BACKGROUND
Subcutaneous implantable cardioverter defibrillators (S-ICDs) are considered an alternative to conventional transvenous ICDs (TV-ICDs) in patients not requiring pacing.
METHODS
We searched MEDLINE and EMBASE for studies evaluating efficacy and safety outcomes in S-ICD patients. Outcomes were pooled across studies.
RESULTS
Sixteen studies were included with 5380 participants (mean age range 33-56 years). Short-term follow-up data were available for 1670 subjects. The most common complication was pocket infection, affecting 2.7%. Other complications included delayed wound healing (0.6%) and wound discomfort (0.8%). 3.8% of S-ICDs were explanted, most commonly for pocket infection. Mortality rates in hospital (0.4%) and during follow-up (3.4% from 12 studies reporting) were low. Incidence of ventricular arrhythmia varied from 0% to 12%. Overall shock efficacy exceeded 96%. Inappropriate shocks affected 4.3% and was most commonly caused by T-wave oversensing.
CONCLUSIONS
Although long-term randomised data are lacking, observational data suggest similar shock efficacy and short-term complication rates between the S-ICD and TV-ICD.
Topics: Arrhythmias, Cardiac; Death, Sudden, Cardiac; Defibrillators, Implantable; Equipment Design; Humans
PubMed: 28687562
DOI: 10.1136/heartjnl-2016-310852 -
Pacing and Clinical Electrophysiology :... Nov 2018Patients go without pacemaker, defibrillator, and cardiac resynchronization therapies (devices) each year due to the prohibitive costs of devices. (Meta-Analysis)
Meta-Analysis
BACKGROUND
Patients go without pacemaker, defibrillator, and cardiac resynchronization therapies (devices) each year due to the prohibitive costs of devices.
OBJECTIVE
We sought to examine data available from studies regarding contemporary risks of reused devices in comparison with new devices.
METHODS
We searched online indexing sites to identify recent studies. Peer-reviewed manuscripts reporting infection, malfunction, premature battery depletion, and device-related death with reused devices were included. The primary study outcome was the composite risk of infection, malfunction, premature battery depletion, and death. Secondary outcomes were the individual risks.
RESULTS
Nine observational studies (published 2009-2017) were identified totaling 2,302 devices (2,017 pacemakers, 285 defibrillators). Five controlled trials were included in meta-analysis (2,114 devices; 1,258 new vs 856 reused). All device reuse protocols employed interrogation to confirm longevity and functionality, disinfectant therapy, and, usually, additional biocidal agents, packaging, and ethylene oxide gas sterilization. Demographic characteristics, indications for pacing, and median follow-up were similar. There were no device-related deaths reported and no statistically significant difference in risk between new versus reused devices for the primary outcome (2.23% vs 3.86% respectively, P = 0.807, odds ratio = 0.76). There were no significant differences seen in the secondary outcomes for the individual risks of infection, malfunction, and premature battery depletion.
CONCLUSIONS
Device reuse utilizing modern protocols did not significantly increase risk of infection, malfunction, premature battery depletion, or device-related death in observational studies. These data provide rationale for proceeding with a prospective multicenter noninferiority randomized control trial.
Topics: Defibrillators, Implantable; Device Removal; Equipment Failure; Equipment Reuse; Humans; Pacemaker, Artificial; Risk Factors
PubMed: 30191580
DOI: 10.1111/pace.13488 -
Cureus Nov 2023Implantable cardioverter defibrillators (ICD) have been recommended as an effective therapy in treating sudden cardiac deaths. This study evaluates the safety and... (Review)
Review
Implantable cardioverter defibrillators (ICD) have been recommended as an effective therapy in treating sudden cardiac deaths. This study evaluates the safety and efficacies of ICDs in detecting arrhythmias. Different ICDs, such as the transvenous cardioverter defibrillator (TV-ICD) and the subcutaneous implantable cardioverter defibrillator (S-ICD), are used. This systematic review identified Embase, PubMed, Medical Literature Analysis and Retrieval System Online (MEDLINE), and Web of Science as the primary electronic databases for research. Supplementation of the available articles for the review was done using Google Scholar. The population, exposure, control, outcome, and studies (PECOS) criteria were used in this study. The quality of the included studies was assessed using the Critical Appraisal Skills Program (CASP) standard checklist. Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines were used in this systematic review. Two researchers conducted the extraction of data. A pre-designed Excel worksheet (Microsoft, Redmond, Washington) was used in the recording of extracted data. Eight studies were identified for use in this systematic review. Safety of the ICDs was observed with the minimum number of reported inappropriate shocks. Studies conducted identified that women had a lower number of incidences when a long detection setting by sex was conducted. Strategic programming of ICDs was noted as effective in lowering the levels of mortality. Studies claimed that the reduction of inappropriate shocks were important in the reduction of myocardial damage, which resulted in the mortality rate among the patients decreasing. Having high cutoff rates and long intervals for detection in ICD programming was noted to help in reducing ICD therapy intervention among patients. Differences among the male and female populations were inconsequential in the efficacy and safety of ICDs. Their effectiveness in sensitivity, pacing success, and defibrillation success were high and very significant. ICDs were safe in their use in the detection of arrhythmias.
PubMed: 38074043
DOI: 10.7759/cureus.48471 -
BMJ Clinical Evidence Nov 2014Acute atrial fibrillation is rapid, irregular, and chaotic atrial activity of recent onset. Various definitions of acute atrial fibrillation have been used in the... (Review)
Review
INTRODUCTION
Acute atrial fibrillation is rapid, irregular, and chaotic atrial activity of recent onset. Various definitions of acute atrial fibrillation have been used in the literature, but for the purposes of this review we have included studies where atrial fibrillation may have occurred up to 7 days previously. Risk factors for acute atrial fibrillation include increasing age, cardiovascular disease, alcohol, diabetes, and lung disease. Acute atrial fibrillation increases the risk of stroke and heart failure. The condition resolves spontaneously within 24 to 48 hours in more than 50% of people; however, many people will require interventions to control heart rate or restore sinus rhythm.
METHODS AND OUTCOMES
We conducted a systematic review and aimed to answer the following clinical questions: What are the effects of interventions to prevent embolism, for conversion to sinus rhythm, and to control heart rate in people with recent-onset atrial fibrillation (within 7 days) who are haemodynamically stable? We searched: Medline, Embase, The Cochrane Library, and other important databases up to April 2014 (Clinical Evidence reviews are updated periodically; please check our website for the most up-to-date version of this review). We included harms alerts from relevant organisations such as the US Food and Drug Administration (FDA) and the UK Medicines and Healthcare products Regulatory Agency (MHRA).
RESULTS
We found 26 studies that met our inclusion criteria. We performed a GRADE evaluation of the quality of evidence for interventions.
CONCLUSIONS
In this systematic review, we present information relating to the effectiveness and safety of the following interventions: amiodarone, antithrombotic treatment before cardioversion, atenolol, bisoprolol, carvedilol, digoxin, diltiazem, direct current cardioversion, flecainide, metoprolol, nebivolol, propafenone, sotalol, timolol, and verapamil.
Topics: Acute Disease; Anti-Arrhythmia Agents; Atrial Fibrillation; Electric Countershock; Humans; Safety
PubMed: 25430048
DOI: No ID Found -
Heart Failure Reviews Jan 2023A subgroup of patients with noncompaction cardiomyopathy (NCCM) is at increased risk of ventricular arrhythmias and sudden cardiac death (SCD). In selected patients with... (Meta-Analysis)
Meta-Analysis Review
A subgroup of patients with noncompaction cardiomyopathy (NCCM) is at increased risk of ventricular arrhythmias and sudden cardiac death (SCD). In selected patients with NCCM, implantable cardioverter-defibrillator (ICD) therapy could be advantageous for preventing SCD. Currently, there is no complete overview of outcome and complications after ICD therapy in patients with NCCM. This study sought to present an overview using pooled data of currently available studies. Embase, MEDLINE, Web of Science, and Cochrane databases were searched and returned 915 studies. After a thorough examination, 12 studies on outcome and complications after ICD therapy in patients with NCCM were included. There were 275 patients (mean age 38.6 years; 47% women) with NCCM and ICD implantation. Most of the patients received an ICD for primary prevention (66%). Pooled analysis demonstrates that the appropriate ICD intervention rate was 11.95 per 100 person-years and the inappropriate ICD intervention rate was 4.8 per 100 person-years. The cardiac mortality rate was 2.37 per 100 person-years. ICD-related complications occurred in 10% of the patients, including lead malfunction and revision (4%), lead displacement (3%), infection (2%), and pneumothorax (2%). Patients with NCCM who are at increased risk of SCD may significantly benefit from ICD therapy, with a high appropriate ICD therapy rate of 11.95 per 100 person-years and a low cardiac mortality rate of 2.37 per 100 person-years. Inappropriate therapy rate of 4.8 per 100 person-years and ICD-related complications were not infrequent and may lead to patient morbidity.
Topics: Humans; Female; Adult; Male; Defibrillators, Implantable; Cardiomyopathies; Arrhythmias, Cardiac; Death, Sudden, Cardiac; Treatment Outcome; Risk Factors
PubMed: 35689132
DOI: 10.1007/s10741-022-10250-w -
Annals of Cardiothoracic Surgery Jul 2017Since the introduction of the implantable cardioverter-defibrillator (ICD) in patients with hypertrophic cardiomyopathy (HCM), the incidence of sudden cardiac death... (Review)
Review
BACKGROUND
Since the introduction of the implantable cardioverter-defibrillator (ICD) in patients with hypertrophic cardiomyopathy (HCM), the incidence of sudden cardiac death (SCD) has been significantly reduced. Given its widespread use, it is important to identify the outcomes associated with ICD use in patients with HCM. The present paper is a systematic review and meta-analysis of the rates of appropriate and inappropriate interventions, mortality, and device complications in HCM patients with an ICD.
METHODS
We conducted a systematic review and meta-analysis on 27 studies reporting outcomes and complications after ICD implantation in patients with HCM. ICD interventions, device complications, and mortality were extracted for analysis.
RESULTS
A total of 3,797 patients with HCM and ICD implantation were included (mean age, 44.5 years; 63% male), of which 83% of patients had an ICD for primary prevention of SCD. The cardiac mortality was 0.9% (95% CI: 0.7-1.3) per year and non-cardiac mortality was 0.8% (95% CI: 0.6-1.2) per year. Annualized appropriate intervention rate was 4.8% and annualized inappropriate intervention was 4.9%. The annual incidence of lead malfunction, lead displacement and infection was 1.4%, 1.3%, and 1.1%, respectively.
CONCLUSIONS
ICD use in patients with HCM produces low rates of cardiac and non-cardiac mortality, and an appropriate intervention rate of 4.8% per year. However, moderate rates of inappropriate intervention and device complications warrant careful patient selection in order to optimize the risk to benefit ratio in this select group of patients.
PubMed: 28944170
DOI: 10.21037/acs.2017.07.05