International Journal of Oral Science Dec 2013The objective of this systematic review was to assess tooth wear against ceramic crowns in posterior region in vitro and in vivo. An electronic PubMed search was... (Review)
Review
The objective of this systematic review was to assess tooth wear against ceramic crowns in posterior region in vitro and in vivo. An electronic PubMed search was conducted to identify studies on tooth wear against ceramic crowns in posterior region. The selected studies were analyzed in regard to type of crowns, natural antagonist, measuring protocol and outcome. From a yield of 1 000 titles, 43 articles were selected for full-text analysis; finally, no in vitro and only five in vivo studies met the inclusion criteria. As there is heterogeneity in design, used measuring method, ceramics and analysis-form, a meta-analysis was not possible. Results of these studies are very controversial which makes a scientifically valid comparison impossible. This review indicated that some all-ceramic crowns are as wear friendly as metal-ceramic crowns. Up to now, it has been impossible to associate tooth wear with any specific causal agent. The role of ceramic surface treatment that might be responsible for the changing in rate of tooth wear seems undetermined as yet through clinical trials. The literature reveals that studies on this topic are subject to a substantial amount of bias. Therefore, additional clinical studies, properly designed to diminish bias, are warranted.
Topics: Crowns; Dental Enamel; Dental Porcelain; Humans; Metal Ceramic Alloys; Surface Properties; Tooth Crown; Tooth Wear
PubMed: 24136675
DOI: 10.1038/ijos.2013.73 -
Clinical Oral Implants Research Sep 2009The objective of this systematic review was to assess the 5-year survival rates and incidences of complications associated with ceramic abutments and to compare them... (Comparative Study)
Comparative Study Review
OBJECTIVES
The objective of this systematic review was to assess the 5-year survival rates and incidences of complications associated with ceramic abutments and to compare them with those of metal abutments.
METHODS
An electronic Medline search complemented by manual searching was conducted to identify randomized-controlled clinical trials, and prospective and retrospective studies providing information on ceramic and metal abutments with a mean follow-up time of at least 3 years. Patients had to have been examined clinically at the follow-up visit. Assessment of the identified studies and data abstraction was performed independently by three reviewers. Failure rates were analyzed using standard and random-effects Poisson regression models to obtain summary estimates of 5-year survival proportions.
RESULTS
Twenty-nine clinical and 22 laboratory studies were selected from an initial yield of 7136 titles and data were extracted. The estimated 5-year survival rate of ceramic abutments was 99.1% [95% confidence interval (CI): 93.8-99.9%] and 97.4% (95% CI: 96-98.3%) for metal abutments. The estimated cumulative incidence of technical complications after 5 years was 6.9% (95% CI: 3.5-13.4%) for ceramic abutments and 15.9% (95% CI: 11.6-21.5%) for metal abutments. Abutment screw loosening was the most frequent technical problem, occurring at an estimated cumulative incidence after 5 years of 5.1% (95% CI: 3.3-7.7%). All-ceramic crowns supported by ceramic abutments exhibited similar annual fracture rates as metal-ceramic crowns supported by metal abutments. The cumulative incidence of biological complications after 5 years was estimated at 5.2% (95% CI: 0.4-52%) for ceramic and 7.7% (95% CI: 4.7-12.5%) for metal abutments. Esthetic complications tended to be more frequent at metal abutments. A meta-analysis of the laboratory data was impossible due to the non-standardized test methods of the studies included.
CONCLUSION
The 5-year survival rates estimated from annual failure rates appeared to be similar for ceramic and metal abutments. The information included in this review did not provide evidence for differences of the technical and biological outcomes of ceramic and metal abutments. However, the information for ceramic abutments was limited in the number of studies and abutments analyzed as well as the accrued follow-up time. Standardized methods for the analysis of abutment strength are needed.
Topics: Alveolar Bone Loss; Animals; Crowns; Dental Abutments; Dental Porcelain; Dental Prosthesis, Implant-Supported; Dental Restoration Failure; Dental Stress Analysis; Denture, Partial, Fixed; Gingival Recession; Gold Alloys; Humans; Survival Analysis; Titanium
PubMed: 19663946
DOI: 10.1111/j.1600-0501.2009.01787.x -
Iranian Journal of Pharmaceutical... 2019An important field of bone tissue engineering (BTE) concerns the design and fabrication of smart scaffolds capable of inducing cellular interactions and differentiation... (Review)
Review
An important field of bone tissue engineering (BTE) concerns the design and fabrication of smart scaffolds capable of inducing cellular interactions and differentiation of osteo-progenitor cells. One of these additives that has gained growing attention is metallic ions as therapeutic agents (MITAs). The specific biological advantage that these ions bring to scaffolds as well as other potential mechanical, and antimicrobial enhancements may vary depending on the ion entity, fabrication method, and biomaterials used. Therefore, this article provides an overview on current status of application of MITAs in BTE and the remaining challenges in the field. Electronic databases, including PubMed, Scopus, Science direct and Cochrane library were searched for studies on MITAs treatments for BTE. We searched for articles in English from January-2000 to October-2019. Abstracts, letters, conference papers and reviews, studies, studies on alloys and studies investigating effects other than enhancement of new bone formation (NBF) were excluded. A detailed summary of relevant metallic ions with specific scaffold material and design, cell type, animal model and defect type, the implantation period, measured parameters and obtained qualitative and quantitative results is presented. No ideal material or fabrication method suited to deliver MITAs can yet be agreed upon, but an investigation into various systems and their drawbacks or potential advantages can lead the future research. A tendency to enhance NBF with MITAs can be observed in the studies. However, this needs to be validated with further studies comparing various ions with each other in the same animal model using critical-sized defects.
PubMed: 32802092
DOI: 10.22037/ijpr.2020.112641.13894 -
The Angle Orthodontist Jan 2010To evaluate the quantitative effects on torque expression of varying the slot size of stainless steel orthodontic brackets and the dimension of stainless steel wire, and... (Review)
Review
OBJECTIVE
To evaluate the quantitative effects on torque expression of varying the slot size of stainless steel orthodontic brackets and the dimension of stainless steel wire, and to analyze the limitations of the experimental methods used.
MATERIALS AND METHODS
In vitro studies measuring torque expression in conventional and self-ligating stainless steel brackets with a torque-measuring device, with the use of straight stainless steel orthodontic wire without second-order mechanics and without loops, coils, or auxiliary wires, were sought through a systematic review process.
RESULTS
Eleven articles were selected. Direct comparison of different studies was limited by differences in the measuring devices used and in the parameters measured. On the basis of the selected studies, in a 0.018 inch stainless steel bracket slot, the engagement angle ranges from 31 degrees with a 0.016 x 0.016 inch stainless steel archwire to 4.6 degrees with a 0.018 x 0.025 inch stainless steel archwire. In a 0.022 inch stainless steel bracket slot, the engagement angle ranges from 18 degrees with a 0.018 x 0.025 inch stainless steel archwire to 6 degrees with a 0.021 x 0.025 inch stainless steel archwire. Active stainless steel self-ligating brackets demonstrate an engagement angle of approximately 7.5 degrees, whereas passive stainless steel self-ligating brackets show an engagement angle of approximately 14 degrees with 0.019 x 0.025 inch stainless steel wire in a 0.022 inch slot.
CONCLUSIONS
The engagement angle depends on archwire dimension and edge shape, as well as on bracket slot dimension, and is variable and larger than published theoretical values. Clinically effective torque can be achieved in a 0.022 inch bracket slot with archwire torsion of 15 to 31 degrees for active self-ligating brackets and of 23 to 35 degrees for passive self-ligating brackets with a 0.019 x 0.025 inch stainless steel wire.
Topics: Dental Alloys; Humans; Materials Testing; Orthodontic Appliance Design; Orthodontic Brackets; Orthodontic Wires; Stainless Steel; Surface Properties; Torque; Torsion, Mechanical
PubMed: 19852662
DOI: 10.2319/080508-352.1 -
Antibiotics (Basel, Switzerland) Jun 2023Few studies have been able to elucidate the correlation of factors determining the strength of interaction between bacterial cells and substrate at the molecular level.... (Review)
Review
Few studies have been able to elucidate the correlation of factors determining the strength of interaction between bacterial cells and substrate at the molecular level. The aim was to answer the following question: What biophysical factors should be considered when analyzing the bacterial adhesion strength on titanium surfaces and its alloys for implants quantified by atomic force microscopy? This review followed PRISMA. The search strategy was applied in four databases. The selection process was carried out in two stages. The risk of bias was analyzed. One thousand four hundred sixty-three articles were found. After removing the duplicates, 1126 were screened by title and abstract, of which 57 were selected for full reading and 5 were included; 3 had a low risk of bias and 2 moderated risks of bias. (1) The current literature shows the preference of bacteria to adhere to surfaces of the same hydrophilicity. However, this fact was contradicted by this systematic review, which demonstrated that hydrophobic bacteria developed hydrogen bonds and adhered to hydrophilic surfaces; (2) the application of surface treatments that induce the reduction of areas favorable for bacterial adhesion interfere more in the formation of biofilm than surface roughness; and (3) bacterial colonization should be evaluated in time-dependent studies as they develop adaptation mechanisms, related to time, which are obscure in this review.
PubMed: 37370313
DOI: 10.3390/antibiotics12060994 -
The Cochrane Database of Systematic... Oct 2019Dental implants are available in different materials, shapes and with different surface characteristics. In particular, numerous implant designs and surface... (Review)
Review
BACKGROUND
Dental implants are available in different materials, shapes and with different surface characteristics. In particular, numerous implant designs and surface modifications have been developed for improving clinical outcome. This is an update of a Cochrane review first published in 2002, and previously updated in 2003, 2005 and 2007.
OBJECTIVES
Primary: to compare the clinical effects of different root-formed osseointegrated dental implant types for replacing missing teeth for the following specific comparisons: implants with different surface preparations, but having similar shape and material; implants with different shapes, but having similar surface preparation and material; implants made of different materials, but having similar surface preparation and shape; different implant types differing in surface preparation, shape, material or a combination of these.Secondary: to compare turned and roughened dental implants for occurrence of early implant failure (before prosthetic loading) and occurrence of peri-implantitis.
SEARCH METHODS
We searched the following electronic databases: the Cochrane Oral Health Group's Trials Register (to 17 January 2014), the Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library 2013, Issue 12), MEDLINE via OVID (1946 to 17 January 2014) and EMBASE via OVID (1980 to 17 January 2014). We placed no restrictions on the language or date of publication when searching the electronic databases.
SELECTION CRITERIA
We included any randomised controlled trial (RCT) comparing osseointegrated dental implants of different materials, shapes and surface properties having a follow-up in function of at least one year. Outcome measures were success of the implants, radiographic peri-implant marginal bone levels changes and incidence of peri-implantitis.
DATA COLLECTION AND ANALYSIS
At least two review authors independently conducted screening, risk of bias assessment and data extraction of eligible trials in duplicate. We expressed results using fixed-effect models (if up to three studies were present in a meta-analysis) or random-effects models (when there were more than three studies) using mean differences (MD) for continuous outcomes and risk ratios (RR) for dichotomous outcomes with 95% confidence intervals (CI). We reported the following endpoints: one, three, five and 10 years after functional loading.
MAIN RESULTS
We identified 81 different RCTs. We included 27 of these RCTs, reporting results from 1512 participants and 3230 implants in the review. We compared 38 different implant types with a follow-up ranging from one to 10 years. All implants were made of commercially pure titanium or its alloys, and had different shapes and surface preparations. We judged two trials to be at low risk of bias, 10 to be at unclear risk of bias and 15 to be at high risk of bias. On a 'per participant' rather than 'per implant' basis, we found no significant differences between various implant types for implant failures. The only observed statistically significant difference for the primary objective regarded more peri-implant bone loss at Nobel Speedy Groovy implants when compared with NobelActive implants (MD -0.59 mm; 95% CI -0.74 to -0.44, different implant shapes). The only observed statistically significant difference for the secondary objective was that implants with turned (smoother) surfaces had a 20% reduction in risk to be affected by peri-implantitis than implants with rough surfaces three years after loading (RR 0.80; 95% CI 0.67 to 0.96). There was a tendency for implants with turned surfaces to fail early more often than implants with roughened surfaces.
AUTHORS' CONCLUSIONS
Based on the results of the included RCTs, we found no evidence showing that any particular type of dental implant had superior long-term success. There was limited evidence showing that implants with relatively smooth (turned) surfaces were less prone to lose bone due to chronic infection (peri-implantitis) than implants with much rougher surfaces (titanium-plasma-sprayed). These findings were based on several RCTs, often at high risk of bias, with few participants and relatively short follow-up periods.
PubMed: 31600407
DOI: 10.1002/14651858.CD003815.pub5 -
Medicina (Kaunas, Lithuania) Sep 2022The aim of the study was to systematically review the overall outcomes of studies comparing the misfit of yttria-stabilized zirconia (Y-TZP) CAD-CAM implant-supported... (Review)
Review
The aim of the study was to systematically review the overall outcomes of studies comparing the misfit of yttria-stabilized zirconia (Y-TZP) CAD-CAM implant-supported frameworks with frameworks fabricated with other materials and techniques. An electronic literature search of English literature was performed using Google Scholar, Scopus, Web of Science, MEDLINE (OVID), EMBASE, and PubMed, using predetermined inclusion criteria. Specific terms were utilized in conducting a search from the inception of the respective database up to May 2022. After the search strategy was applied, the data were extracted and the results were analyzed. The focused question was: Is the misfit of the implant-supported zirconia CAD-CAM framework lower than that of non-Y-TZP implant-supported fixed restorations? Eleven articles were included for qualitative assessment and critical appraisal in this review. In the included studies, Y-TZP CAD-CAM implant-supported frameworks were compared to Titanium (Ti), Ni-Cr, Co-Cr, PEEK and high-density polymer, and cast and CAD-CAM frameworks. The studies used scanning electron microscopy, one-screw tests, digital or optical microscopy, 3D virtual assessment, and replica techniques for analyzing the misfit of frameworks. Six studies showed comparable misfits among the Y-TZP CAD-CAM frameworks and the controls. Three studies showed higher misfits for the Y-TZP CAD-CAM frameworks, whereas two studies reported lower misfits for Y-TZP CAD-CAM implant frameworks compared to controls. Y-TZP CAD-CAM implant-supported frameworks have comparable misfits to other implant-supported frameworks. However, due to heterogeneity in the methodologies of the included studies, the overall numerical misfit of the frameworks assessed in the reviewed studies is debatable.
Topics: Humans; Titanium; Zirconium; Computer-Aided Design; Polymers
PubMed: 36295507
DOI: 10.3390/medicina58101347 -
Brazilian Oral Research 2019The objective of this systematic review and meta-analysis was to evaluate the effect of welding techniques on implant-supported prostheses and determine whether they... (Meta-Analysis)
Meta-Analysis
The objective of this systematic review and meta-analysis was to evaluate the effect of welding techniques on implant-supported prostheses and determine whether they contribute to a better adaptation compared with a one-piece cast. A search was conducted using the PubMed/MEDLINE, Embase, and Cochrane Library databases, and articles published until November 2017 were obtained from these databases. This review followed the PRISMA criteria and is registered on the PROSPERO platform (CRD42017081865). The PICO question was "Do welding procedures in one-piece cast implant-supported frameworks influence implant/abutment-framework marginal misfits?" Eleven studies were selected for a qualitative analysis, and seven studies were selected for a quantitative analysis. A total of 189 specimens were fabricated using different materials (cp-Ti, Ni-Cr, Cr-Co, and noble alloys), and welding techniques such as laser welding, conventional welding, tungsten inert gas, and brazing were applied. A vertical marginal misfit was measured using an optical microscope, a stereomicroscope, and/or a scanning electron microscopy. The qualitative analysis in the studies demonstrated a positive effect of the welding techniques on the adaptation of the infrastructures. The meta-analysis confirmed the results (p < 0.00001; MD: -36.14; 95%CI: -48.69 to -23.59). Within the limitations of this study and regarding the heterogeneity of the samples, we conclude that the soldering point technique is effective for obtaining relatively low values of marginal misfit, with laser welding as the most effective technique. However, additional studies were recommended due to the heterogeneity of different variables (alloys, connection, and misfit evaluation) in the included studies.
Topics: Dental Casting Technique; Dental Marginal Adaptation; Dental Prosthesis Design; Dental Prosthesis, Implant-Supported; Dental Soldering; Humans; Prosthesis Fitting; Welding
PubMed: 31778474
DOI: 10.1590/1807-3107bor-2019.vol33.0110 -
Journal of Oral & Maxillofacial Research 2021There is a concern whether the enhancement on implant surface roughness is responsible for higher biofilm formation, which acts as an aetiological factor for... (Review)
Review
OBJECTIVES
There is a concern whether the enhancement on implant surface roughness is responsible for higher biofilm formation, which acts as an aetiological factor for peri-implant diseases. The aim of the present systematic review was to answer the following question: "Are rough surfaces more susceptible to early biofilm formation when compared to smoother surfaces on titanium specimens?".
MATERIAL AND METHODS
The research was performed on PubMed, Web of Science and Scopus, up to August 2021. Eligibility criteria included studies that analysed human biofilm formation on titanium specimens with distinct surface roughness (smooth vs minimally, moderate, or rough) over the experimental times of 1 or 3 days. Roughness average (Ra) and biofilm analysis parameters were extracted from selected articles. Risk of bias was evaluated using the Checklist for Quasi-Experimental Studies.
RESULTS
Of 5286 papers, 5 were included and analysed. Smooth titanium surfaces included machined and anodized titanium/Ti-6Al-4V; machined and acid etched TiZr. Minimally, moderately, or rough surfaces comprised titanium and titanium alloys (TiZr, Ti-6Al-4V), that received surface treatments (anodization, acid-etching, blasting, hydroxyapatite-coating). No statistically significant difference on biofilm formation on rough and smooth titanium surfaces was reported by 3 studies, while more contamination on rough titanium surfaces was stated by 2 investigations. An isolated smooth surface has also been associated to higher contamination. Moderate to high quality methodological assessment of studies were identified.
CONCLUSIONS
It is not possible to assume that rough surfaces are more susceptible to early biofilm formation than smooth titanium surfaces. Additional studies are required to study this multifarious interaction.
PubMed: 35222868
DOI: 10.5037/jomr.2021.12401 -
BMJ (Clinical Research Ed.) Nov 2011To determine comparative safety and effectiveness of combinations of bearing surfaces of hip implants. (Comparative Study)
Comparative Study Review
OBJECTIVE
To determine comparative safety and effectiveness of combinations of bearing surfaces of hip implants.
DESIGN
Systematic review of clinical trials, observational studies, and registries.
DATA SOURCES
Medline, Embase, Cochrane Controlled Trials Register, reference lists of articles, annual reports of major registries, summaries of safety and effectiveness for pre-market application and mandated post-market studies at the United States Food and Drug Administration.
STUDY SELECTION
Criteria for inclusion were comparative studies in adults reporting information for various combinations of bearings (such as metal on metal and ceramic on ceramic). Data search, abstraction, and analyses were independently performed and confirmed by at least two authors. Qualitative data syntheses were performed.
RESULTS
There were 3139 patients and 3404 hips enrolled in 18 comparative studies and over 830 000 operations in national registries. The mean age range in the trials was 42-71, and 26-88% were women. Disease specific functional outcomes and general quality of life scores were no different or they favoured patients receiving metal on polyethylene rather than metal on metal in the trials. While one clinical study reported fewer dislocations associated with metal on metal implants, in the three largest national registries there was evidence of higher rates of implant revision associated with metal on metal implants compared with metal on polyethylene. One trial reported fewer revisions with ceramic on ceramic compared with metal on polyethylene implants, but data from national registries did not support this finding.
CONCLUSIONS
There is limited evidence regarding comparative effectiveness of various hip implant bearings. Results do not indicate any advantage for metal on metal or ceramic on ceramic implants compared with traditional metal on polyethylene or ceramic on polyethylene bearings.
Topics: Ceramics; Chromium Alloys; Female; Hip Prosthesis; Humans; Joint Diseases; Male; Polyethylene; Prosthesis Design; Recovery of Function; Reoperation; Safety; Treatment Outcome
PubMed: 22127517
DOI: 10.1136/bmj.d7434