-
The Cochrane Database of Systematic... Jul 2018Initial arch wires are the first arch wires to be inserted into the fixed appliance at the beginning of orthodontic treatment and are used mainly for the alignment of... (Meta-Analysis)
Meta-Analysis Review
BACKGROUND
Initial arch wires are the first arch wires to be inserted into the fixed appliance at the beginning of orthodontic treatment and are used mainly for the alignment of teeth by correcting crowding and rotations. With a number of different types of orthodontic arch wires available for initial tooth alignment, it is important to understand which wire is most efficient, as well as which wires cause least amount of root resorption and pain during the initial aligning stage of treatment. This is an update of the review entitledInitial arch wires for alignment of crooked teeth with fixed orthodontic braces, which was first published in 2010.
OBJECTIVES
To assess the effects of initial arch wires for the alignment of teeth with fixed orthodontic braces, in terms of the rate of tooth alignment, amount of root resorption accompanying tooth movement, and intensity of pain experienced by patients during the initial alignment stage of treatment.
SEARCH METHODS
Cochrane Oral Health's Information Specialist searched the following databases: Cochrane Oral Health's Trials Register (to 5 October 2017), the Cochrane Central Register of Controlled Trials (CENTRAL) (the Cochrane Library, 2017, Issue 9), MEDLINE Ovid (1946 to 5 October 2017), and Embase Ovid (1980 to 5 October 2017. The US National Institutes of Health Trials Registry (ClinicalTrials.gov) and the World Health Organization International Clinical Trials Registry Platform were searched for ongoing trials. No restrictions were placed on the language or date of publication when searching the electronic databases.
SELECTION CRITERIA
We included randomised controlled trials (RCTs) of initial arch wires to align teeth with fixed orthodontic braces. We included only studies involving participants with upper or lower, or both, full arch fixed orthodontic appliances.
DATA COLLECTION AND ANALYSIS
Two review authors were responsible for study selection, 'Risk of bias' assessment and data extraction. We resolved disagreements by discussion between the review authors. We contacted corresponding authors of included studies to obtain missing information. We assessed the quality of the evidence for each comparison and outcome as high, moderate, low or very low, according to GRADE criteria.
MAIN RESULTS
For this update, we found three new RCTs (228 participants), bringing the total to 12 RCTs with 799 participants. We judged three studies to be at high risk of bias, and three to be at low risk of bias; six were unclear. None of the studies reported the adverse outcome of root resorption. The review assessed six comparisons.1. Multistrand stainless steel versus superelastic nickel-titanium (NiTi) arch wires. There were five studies in this group and it was appropriate to undertake a meta-analysis of two of them. There is insufficient evidence from these studies to determine whether there is a difference in rate of alignment between multistrand stainless steel and superelastic NiTi arch wires (mean difference (MD) -7.5 mm per month, 95% confidence interval (CI) -26.27 to 11.27; 1 study, 48 participants; low-quality evidence). The findings for pain at day 1 as measured on a 100 mm visual analogue scale suggested that there was no meaningful difference between the interventions (MD -2.68 mm, 95% CI -6.75 to 1.38; 2 studies, 127 participants; moderate-quality evidence).2. Multistrand stainless steel versus thermoelastic NiTi arch wires. There were two studies in this group, but it was not appropriate to undertake a meta-analysis of the data. There is insufficient evidence from the studies to determine whether there is a difference in rate of alignment between multistrand stainless steel and thermoelastic NiTi arch wires (low-quality evidence). Pain was not measured.3. Conventional NiTi versus superelastic NiTi arch wires. There were three studies in this group, but it was not appropriate to undertake a meta-analysis of the data. There is insufficient evidence from these studies to determine whether there is any difference between conventional and superelastic NiTi arch wires with regard to either alignment or pain (low- to very low-quality evidence).4. Conventional NiTi versus thermoelastic NiTi arch wires. There were two studies in this group, but it was not appropriate to undertake a meta-analysis of the data. There is insufficient evidence from these studies to determine whether there is a difference in alignment between conventional and thermoelastic NiTi arch wires (low-quality evidence). Pain was not measured.5. Single-strand superelastic NiTi versus coaxial superelastic NiTi arch wires. There was only one study (24 participants) in this group. There is moderate-quality evidence that coaxial superelastic NiTi can produce greater tooth movement over 12 weeks (MD -6.76 mm, 95% CI -7.98 to -5.55). Pain was not measured.6. Superelastic NiTi versus thermoelastic NiTi arch wires. There were three studies in this group, but it was not appropriate to undertake a meta-analysis of the data. There is insufficient evidence from these studies to determine whether there is a difference in alignment or pain between superelastic and thermoelastic NiTi arch wires (low-quality evidence).
AUTHORS' CONCLUSIONS
Moderate-quality evidence shows that arch wires of coaxial superelastic nickel-titanium (NiTi) can produce greater tooth movement over 12 weeks than arch wires made of single-strand superelastic NiTi. Moderate-quality evidence also suggests there may be no difference in pain at day 1 between multistrand stainless steel arch wires and superelastic NiTi arch wires. Other than these findings, there is insufficient evidence to determine whether any particular arch wire material is superior to any other in terms of alignment rate, time to alignment, pain and root resorption.
Topics: Alloys; Dental Alloys; Humans; Orthodontic Brackets; Orthodontic Wires; Randomized Controlled Trials as Topic; Root Resorption; Tooth Movement Techniques; Toothache
PubMed: 30064155
DOI: 10.1002/14651858.CD007859.pub4 -
Materials (Basel, Switzerland) Jul 2019Sterilization is a fundamental step in the reuse of endodontic instruments. The sterilization procedure involves disinfection, cleaning, washing, drying, packaging, and... (Review)
Review
Sterilization is a fundamental step in the reuse of endodontic instruments. The sterilization procedure involves disinfection, cleaning, washing, drying, packaging, and sterilization by heat. Heat sterilization can lead to changes in the physical and mechanical properties of dental instruments. These changes can affect the external surfaces via micropitting, corrosion, a reduction in cutting capacity, and/or an influence on the resistance to cyclic fatigue or to torsional fatigue. In this study, we examined the modification of the torsional properties of endodontic instruments after hot sterilization, and compared the properties with instruments not subjected to hot sterilization cycles in terms of resistance to torsional fatigue and deflection angle in NiTi and steel instruments. The following work was performed based on the PRISMA indications. Studies were identified through bibliographic research using electronic databases. A total of 725 records were identified in the PubMed and Scopus databases. A total of 685 records remained after exclusion by year of publication (1979 to 2019). With the application of the eligibility criteria (all articles pertaining to the issue of sterilization in endodontics), we found 146 articles, which decreased to 130 articles after elimination of duplications. There were 45 articles that studied the influences of sterilization procedures on the physical and mechanical characteristics of the instruments, and 12 that measured parameters related to resistance to torsional fatigue. Applying the inclusion and exclusion criteria resulted in a total of eight articles for quantitative analysis. The meta-analysis results show a pejorative effect of torsional fatigue for NiTi instruments subjected to heat sterilization compared to the non-sterilized control.
PubMed: 31288384
DOI: 10.3390/ma12132190 -
The Saudi Dental Journal Feb 2023The aim of this systematic review was to present the current knowledge on the influence of laser surface treatment on the adhesion of bacteria to titanium and its alloys. (Review)
Review
OBJECTIVE
The aim of this systematic review was to present the current knowledge on the influence of laser surface treatment on the adhesion of bacteria to titanium and its alloys.
DESIGN
This review was structured according to PRISMA guidelines for systematic reviews and -analyses, and registered on the Open Science Framework platform (https://doi.org/10.17605/OSF.IO/FTA3W). Article searches were performed in 4 databases: PubMed, Scopus, Embase, and Science Direct. In addition, a manual search was performed in the reference lists of the selected articles. The selection of articles was performed by two reviewers. The articles found were screened for eligibility using the previously established inclusion and exclusion criteria. The methodological quality of the studies was assessed using the Joanna Briggs Institute (JBI) Critical Assessment Checklist for Quasi-Experimental Studies (non-randomized experimental studies).
RESULTS
Most of the studies evaluated showed that surface treatment by laser irradiation can affect the adhesion of bacteria to titanium surfaces and that this is directly related to changes in surface properties such as chemical composition, morphology, roughness, and wettability, as well as the type of bacterial species involved.
CONCLUSIONS
The studies considered in this systematic review have shown that surface treatment by laser irradiation is a promising technique to reduce the adhesion of bacteria on the surface of titanium implants.
PubMed: 36942202
DOI: 10.1016/j.sdentj.2023.01.004 -
The Cochrane Database of Systematic... Apr 2013Initial arch wires are the first arch wires to be inserted into the fixed appliance at the beginning of orthodontic treatment and are used mainly for the alignment of... (Meta-Analysis)
Meta-Analysis Review
BACKGROUND
Initial arch wires are the first arch wires to be inserted into the fixed appliance at the beginning of orthodontic treatment and are used mainly for the alignment of teeth by correcting crowding and rotations. With a number of different types of orthodontic arch wires available for initial tooth alignment, it is important to understand which wire is most efficient, as well as which wires cause the least amount of root resorption and pain during the initial aligning stage of treatment. This is an update of the review 'Initial arch wires for alignment of crooked teeth with fixed orthodontic braces' first published in the Cochrane Database of Systematic Reviews 2010, Issue 4.
OBJECTIVES
To assess the effects of initial arch wires for alignment of teeth with fixed orthodontic braces in relation to alignment speed, root resorption and pain intensity.
SEARCH METHODS
We searched the following electronic databases: the Cochrane Oral Health Group's Trials Register (to 2 August 2012), CENTRAL (The Cochrane Library 2012, Issue 7), MEDLINE via OVID (1950 to 2 August 2012) and EMBASE via OVID (1980 to 2 August 2012). We also searched the reference lists of relevant articles. There was no restriction with regard to publication status or language of publication. We contacted all authors of included studies to identify additional studies.
SELECTION CRITERIA
We included randomised controlled trials (RCTs) of initial arch wires to align teeth with fixed orthodontic braces. Only studies involving participants with upper and/or lower full arch fixed orthodontic appliances were included.
DATA COLLECTION AND ANALYSIS
Two review authors were responsible for study selection, validity assessment and data extraction. All disagreements were resolved by discussion amongst the review team. Corresponding authors of included studies were contacted to obtain missing information.
MAIN RESULTS
Nine RCTs with 571 participants were included in this review. All trials were at high risk of bias and a number of methodological limitations were identified. All trials had at least one potentially confounding factor (such as bracket type, slot size, ligation method, extraction of teeth) which is likely to have influenced the outcome and was not controlled in the trial. None of the trials reported the important adverse outcome of root resorption.Three groups of comparisons were made.(1) Multistrand stainless steel initial arch wires compared to superelastic nickel titanium (NiTi) initial arch wires. There were four trials in this group, with different comparisons and outcomes reported at different times. No meta-analysis was possible. There is insufficient evidence from these trials to determine whether or not there is a difference in either rate of alignment or pain between stainless steel and NiTi initial arch wires.(2) Conventional (stabilised) NiTi initial arch wires compared to superelastic NiTi initial arch wires. There were two trials in this group, one reporting the outcome of alignment over 6 months and the other reporting pain over 1 week. There is insufficient evidence from these trials to determine whether or not there is any difference between conventional (stabilised) and superelastic NiTi initial arch wires with regard to either alignment or pain.(3) Single-strand superelastic NiTi initial arch wires compared to other NiTi (coaxial, copper NiTi (CuNiTi) or thermoelastic) initial arch wires. The three trials in this comparison each compared a different product against single-strand superelastic NiTi. There is very weak unreliable evidence, based on one very small study (n = 24) at high risk of bias, that coaxial superelastic NiTi may produce greater tooth movement over 12 weeks, but no information on associated pain or root resorption. This result should be interpreted with caution until further research evidence is available. There is insufficient evidence to determine whether or not there is a difference between either thermoelastic or CuNiTi and superelastic NiTi initial arch wires.
AUTHORS' CONCLUSIONS
There is no reliable evidence from the trials included in this review that any specific initial arch wire material is better or worse than another with regard to speed of alignment or pain. There is no evidence at all about the effect of initial arch wire materials on the important adverse effect of root resorption. Further well-designed and conducted, adequately-powered, RCTs are required to determine whether the performance of initial arch wire materials as demonstrated in the laboratory, makes a clinically important difference to the alignment of teeth in the initial stage of orthodontic treatment in patients.
Topics: Dental Alloys; Humans; Orthodontic Brackets; Orthodontic Wires; Randomized Controlled Trials as Topic; Root Resorption; Tooth Movement Techniques; Toothache
PubMed: 23633347
DOI: 10.1002/14651858.CD007859.pub3 -
PloS One 2013The use of metal-on-metal (MoM) total hip arthroplasty (THA) increased in the last decades. A release of metal products (i.e. particles, ions, metallo-organic compounds)... (Review)
Review
INTRODUCTION
The use of metal-on-metal (MoM) total hip arthroplasty (THA) increased in the last decades. A release of metal products (i.e. particles, ions, metallo-organic compounds) in these implants may cause local and/or systemic adverse reactions. Metal ion concentrations in body fluids are surrogate measures of metal exposure.
OBJECTIVE
To systematically summarize and critically appraise published studies concerning metal ion concentrations after MoM THA.
METHODS
Systematic review of clinical trials (RCTs) and epidemiological studies with assessment of metal ion levels (cobalt, chromium, titanium, nickel, molybdenum) in body fluids after implantation of metalliferous hip replacements. Systematic search in PubMed and Embase in January 2012 supplemented by hand search. Standardized abstraction of pre- and postoperative metal ion concentrations stratified by type of bearing (primary explanatory factor), patient characteristics as well as study quality characteristics (secondary explanatory factors).
RESULTS
Overall, 104 studies (11 RCTs, 93 epidemiological studies) totaling 9.957 patients with measurement of metal ions in body fluids were identified and analyzed. Consistently, median metal ion concentrations were persistently elevated after implantation of MoM-bearings in all investigated mediums (whole blood, serum, plasma, erythrocytes, urine) irrespective of patient characteristics and study characteristics. In several studies very high serum cobalt concentrations above 50 µg/L were measured (detection limit typically 0.3 µg/L). Highest metal ion concentrations were observed after treatment with stemmed large-head MoM-implants and hip resurfacing arthroplasty.
DISCUSSION
Due to the risk of local and systemic accumulation of metallic products after treatment with MoM-bearing, risk and benefits should be carefully balanced preoperatively. The authors support a proposed "time out" for stemmed large-head MoM-THA and recommend a restricted indication for hip resurfacing arthroplasty. Patients with implanted MoM-bearing should receive regular and standardized monitoring of metal ion concentrations. Further research is indicated especially with regard to potential systemic reactions due to accumulation of metal products.
Topics: Arthroplasty, Replacement, Hip; Body Fluids; Chromium Alloys; Cobalt; Humans; Metals; Molybdenum; Nickel; Postoperative Complications; Titanium
PubMed: 23950923
DOI: 10.1371/journal.pone.0070359 -
Materials (Basel, Switzerland) Aug 2020Complex dental components which are individually tailored to the patient can be obtained due to new additive manufacturing technology. This paper reviews the metallic... (Review)
Review
Complex dental components which are individually tailored to the patient can be obtained due to new additive manufacturing technology. This paper reviews the metallic powders used in dental applications, the fabrication process (build orientation, process parameters) and post-processing processes (stress relieving, surface finishing). A review of the literature was performed using PubMed, ScienceDirect, Mendeley and Google Scholar. Over eighty articles were selected based on relevance to this review. This paper attempts to include the latest research from 2010 until 2020, however, older manuscripts (10 articles) were also selected. Over 1200 records were identified through the search; these were screened for title and/or summary. Over eighty articles were selected based on relevance to this review. In order to obtain a product which can be used in clinical applications, the appropriate manufacturing parameters should be selected. A discussion was made on optimal selective laser melting (SLM) parameters in dentistry. In addition, this paper includes a critical review of applied thermal treatment methods for Co-Cr alloys used in dentistry.
PubMed: 32785055
DOI: 10.3390/ma13163524 -
The Journal of Evidence-based Dental... Mar 2018This systematic review evaluated the effectiveness of nickel-titanium (NiTi) rotary files compared to stainless-steel (SST) hand files. (Meta-Analysis)
Meta-Analysis
INTRODUCTION
This systematic review evaluated the effectiveness of nickel-titanium (NiTi) rotary files compared to stainless-steel (SST) hand files.
METHODS
An electronic search was performed on Medline, EMBASE, CENTRAL and Scopus databases up to February 2016. An additional hand searching was performed in 13 journals. The studies were classified according to study type and the outcome variables. Two reviewers independently applied eligibility criteria, extracted data, and three reviewers independently assessed the quality of the evidence of each included study according to The Cochrane Collaboration's procedures. A meta-analysis was performed whenever it was possible.
RESULTS
The electronic and hand search strategies yielded 1155 references of studies after removal of duplicates. Four clinical studies (two prospective and two retrospective studies) and 18 in vitro studies (on extracted teeth) were included for the qualitative synthesis after full-text evaluation of the eligible studies. The overall level of methodological quality of the studies included can be considered inadequate. Only one clinical study was judged at low risk of bias, whereas most non-clinical studies had a low risk of bias. Three meta-analyses, based on a very limited number of studies, could be performed. Each meta-analysis contained two studies. Of these, one meta-analysis was based on clinical studies.
CONCLUSIONS
The results of this systematic review suggested that NiTi rotary instruments were associated with lower canal transportation and apical extrusion when compared to SST hand files, whereas both groups had similar outcomes in terms of success of therapy, amount of residual bacteria, and cleansing ability after treatment. However, due to the limited evidence available, these results should be interpreted with caution. Consequently, more randomized control trials using standardized protocols are needed in order to provide more solid recommendations.
Topics: Dental Alloys; Dental Instruments; Humans; Nickel; Prospective Studies; Retrospective Studies; Root Canal Preparation; Root Canal Therapy; Stainless Steel; Titanium
PubMed: 29478682
DOI: 10.1016/j.jebdp.2017.08.001 -
Journal of Orthopaedic Surgery and... Feb 2022Titanium and its alloys have been widely employed for bone tissue repair and implant manufacturing. The rapid development of three-dimensional (3D) printing technology...
BACKGROUND
Titanium and its alloys have been widely employed for bone tissue repair and implant manufacturing. The rapid development of three-dimensional (3D) printing technology has allowed fabrication of porous titanium scaffolds with controllable microstructures, which is considered to be an effective method for promoting rapid bone formation and decreasing bone absorption. The purpose of this systematic review was to evaluate the osteogenic potential of 3D-printed porous Ti6Al4V (Ti64) scaffold for repairing long bone defects in animal models and to investigate the influential factors that might affect its osteogenic capacity.
METHODS
Electronic literature search was conducted in the following databases: PubMed, Web of Science, and Embase up to September 2021. The SYRCLE's tool and the modified CAMARADES list were used to assess the risk of bias and methodological quality, respectively. Due to heterogeneity of the selected studies in relation to protocol and outcomes evaluated, a meta-analysis could not be performed.
RESULTS
The initial search revealed 5858 studies. Only 46 animal studies were found to be eligible based on the inclusion criteria. Rabbit was the most commonly utilized animal model. A pore size of around 500-600 µm and porosity of 60-70% were found to be the most ideal parameters for designing the Ti64 scaffold, where both dodecahedron and diamond pores optimally promoted osteogenesis. Histological analysis of the scaffold in a rabbit model revealed that the maximum bone area fraction reached 59.3 ± 8.1% at weeks 8-10. Based on micro-CT assessment, the maximum bone volume fraction was found to be 34.0 ± 6.0% at weeks 12.
CONCLUSIONS
Ti64 scaffold might act as a promising medium for providing sufficient mechanical support and a stable environment for new bone formation in long bone defects. Trail registration The study protocol was registered in the PROSPERO database under the number CRD42020194100.
Topics: Alloys; Animals; Bone and Bones; Osteogenesis; Porosity; Printing, Three-Dimensional; Rabbits; Tissue Engineering; Tissue Scaffolds; Titanium
PubMed: 35109907
DOI: 10.1186/s13018-022-02960-6 -
Frontiers in Bioengineering and... 2023Bioactive glasses (BGs) are ideal biomaterials in the field of bio-restoration due to their excellent biocompatibility. Titanium alloys are widely used as a bone graft...
Bioactive glasses (BGs) are ideal biomaterials in the field of bio-restoration due to their excellent biocompatibility. Titanium alloys are widely used as a bone graft substitute material because of their excellent corrosion resistance and mechanical properties; however, their biological inertness makes them prone to clinical failure. Surface modification of titanium alloys with bioactive glass can effectively combine the superior mechanical properties of the substrate with the biological properties of the coating material. In this review, the relevant articles published from 2013 to the present were searched in four databases, namely, Web of Science, PubMed, Embase, and Scopus, and after screening, 49 studies were included. We systematically reviewed the basic information and the study types of the included studies, which comprise experiments, animal tests, and clinical trials. In addition, we summarized the applied coating technologies, which include pulsed laser deposition (PLD), electrophoretic deposition, dip coating, and magnetron sputtering deposition. The superior biocompatibility of the materials in terms of cytotoxicity, cell activity, hemocompatibility, anti-inflammatory properties, bioactivity, and their good bioactivity in terms of osseointegration, osteogenesis, angiogenesis, and soft tissue adhesion are discussed. We also analyzed the advantages of the existing materials and the prospects for further research. Even though the current research status is not extensive enough, it is still believed that BG-coated Ti implants have great clinical application prospects.
PubMed: 38033819
DOI: 10.3389/fbioe.2023.1269223 -
Hua Xi Kou Qiang Yi Xue Za Zhi = Huaxi... Jun 2018This review aims to assess the relationship between initial archwire materials and pain at the initial stage of orthodontic treatment. (Meta-Analysis)
Meta-Analysis
OBJECTIVE
This review aims to assess the relationship between initial archwire materials and pain at the initial stage of orthodontic treatment.
METHODS
On October 1, 2017, seven databases were searched electronically for studies oninitial archwire materials and pain at the initial stage of orthodontic treatment. Quality assessment was performed with bias risk assessment tools suggested by Cochrane's handbook. Data extraction of included studies was also carried out. Network Meta- analysis was conducted using R 3.4.2 (with JAGS 4.3.0), GeMTC 0.14.3, and STATA 11.0.
RESULTS
Five studies with 330 participants were included, comparing four different materials: multi-stranded stainless steel, conventional nickel-titanium, super-elastic nickel-titanium, and thermal heat-activated nickel-titanium. Two studies were at low risk of bias, one was at high risk of bias, and the remaining two were at unclear risk of bias. Network Meta-analysis results showed no statistical differences of pain among the four initial archwire materials at day 1 and day 7. However, the most painless material was most likely to be thermal heat-activated nickel-titanium on rank probability.
CONCLUSIONS
On statistical probability, thermal heat-activated nickel-titanium initial arch wires is most likely to cause the least pain at the initial stage of orthodontic treatment, compared with other materials.
Topics: Dental Alloys; Humans; Materials Testing; Network Meta-Analysis; Nickel; Orthodontic Appliance Design; Orthodontic Brackets; Orthodontic Wires; Pain; Stainless Steel; Surface Properties; Titanium
PubMed: 29984932
DOI: 10.7518/hxkq.2018.03.013