Journal of Orthopaedic Surgery and... Aug 2023With the increasing prevalence of osteoarthritis of the hip and knee, total joint replacement, the end-stage treatment, provides pain relief and restoration of function,... (Meta-Analysis)
Meta-Analysis Review
OBJECTIVE
With the increasing prevalence of osteoarthritis of the hip and knee, total joint replacement, the end-stage treatment, provides pain relief and restoration of function, but is often associated with massive blood loss. Tranexamic acid (TXA) has been reported to reduce perioperative blood loss in hip or knee arthroplasty. However, the optimal dose of TXA administration remains controversial. Therefore, we performed a meta-analysis combining data from 5 trials comparing the efficacy and safety of one fixed dose of 1 g intravenously administered TXA with two doses of 1 g each administered intravenously for hip or knee arthroplasty.
METHODS
PubMed, Medline, Embase, Web of Science, and The Cochrane Library were searched from January 2000 to February 2023. Our meta-analysis included randomized controlled trials and cohort studies comparing the efficacy and safety of different doses of intravenous TXA (IV-TXA) for THA or TKA. The observation endpoints included total blood loss, postoperative hemoglobin drop, blood transfusion rate, length of hospital stay, incidence of deep venous thrombosis (DVT), and incidence of pulmonary embolism (PE). Meta-analysis was performed according to Cochrane's guidelines and PRISMA statement. The Danish RevMan5.3 software was used for data merging.
RESULTS
Five cohort studies involving 5542 patients met the inclusion criteria. Our meta-analysis showed that the two groups were significantly higher in total blood loss (mean difference (MD) = - 65.60, 95% confidence interval (CI) [- 131.46, 0.26], P = 0.05); blood transfusion rate (risk difference (RD) = 0.00, 95% CI [- 0.01, 0.02], P = 0.55); postoperative hemoglobin (MD = 0.02, 95% CI [- 0.09, 0.13], P = 0.31); postoperative hospital stay days (MD = - 0.13), 95% CI [- 0.35, 0.09], P = 0.25); DVT (RD = 0.00, 95% CI [- 0.00, 0.01], P = 0.67); PE (RD = 0.00, 95% CI [- 0.01, 0.00], P = 0.79). There was some inherent heterogeneity due to variance in sample size across each major study.
CONCLUSION
1 dose of 1 g and 2 doses of 1 g IV-TXA each time have similar effects on reducing blood loss, blood transfusion rate, postoperative hemoglobin level, and postoperative hospital stay after TKA or THA, without increasing the risk of postoperative complications risk. For patients at high risk of thromboembolic events, one dose of 1 g TXA throughout surgery may be preferred. However, higher-quality RCT is needed to explore the optimal protocol dose to recommend the widespread use of TXA in total joint arthroplasty. Trial registration We conducted literature selection, eligibility criteria evaluation, data extraction and analysis on the research program registered in Prospero (CRD42023405387) on March 16, 2023.
Topics: Humans; Tranexamic Acid; Antifibrinolytic Agents; Arthroplasty, Replacement, Knee; Venous Thrombosis; Blood Loss, Surgical; Arthroplasty, Replacement, Hip; Administration, Intravenous; Pulmonary Embolism; Hemoglobins
PubMed: 37563702
DOI: 10.1186/s13018-023-03929-9 -
Foot and Ankle Surgery : Official... Dec 2022Total ankle arthroplasty (TAA) is increasingly used as a treatment for end-stage ankle arthropathy. However, TAA may be more sensitive to complications, failure and... (Meta-Analysis)
Meta-Analysis Review
BACKGROUND
Total ankle arthroplasty (TAA) is increasingly used as a treatment for end-stage ankle arthropathy. However, TAA may be more sensitive to complications, failure and subsequent re-operations compared to ankle arthrodesis. The aim of this systematic review and meta-analysis is to generate an overview of complications of TAA surgery.
METHODS
PubMed, EMBASE and the Cochrane library were searched between 2000 and 2020 to identify all papers reporting on complications in TAA surgery. Meta-analysis was conducted based on type of complication in TAA surgery. Pooled estimates of complications were calculated using a random effects model. Risk of bias and quality was assessed using the Cochrane risk of bias and ROBINS-I tools. The confidence in estimates was rated and described according to the recommendations of the GRADE working group.
RESULTS
One hundred twenty-seven studies were included in this systematic review. All combined, they reported on 16.964 TAAs with an average follow-up of 47.99 ± 29.18 months. Complications with highest reported pooled incidence were intra-operative fracture 0.06 (95 %CI 0.04-0.08) (GRADE Very low) and impingement 0.06 (95 %CI 0.04-0.08) (GRADE low) respectively.
CONCLUSION
Reported complication incidence of TAA surgery is still high and remains a significant clinical problem that can be severely hampering long-term clinical survival of the prosthesis. The results of this systematic review and meta-analysis can help guide surgeons in informing their patient about complication risks. Implementation of more stringent patient selection criteria might contribute to diminishing TAA complication rates.
Topics: Humans; Retrospective Studies; Arthroplasty, Replacement, Ankle; Arthrodesis; Ankle Joint; Reoperation; Treatment Outcome
PubMed: 35872118
DOI: 10.1016/j.fas.2022.07.004 -
Journal of Orthopaedic Surgery and... Dec 2023Extended reality (XR), including virtual reality, augmented reality (AR), and mixed reality, has been used to help achieve accurate acetabular cup placement in total hip... (Meta-Analysis)
Meta-Analysis
BACKGROUND
Extended reality (XR), including virtual reality, augmented reality (AR), and mixed reality, has been used to help achieve accurate acetabular cup placement in total hip arthroplasty (THA). This study aimed to compare the differences between XR-assisted and conventional THA.
METHODS
In this systematic review and meta-analysis, electronic databases including PubMed, Embase, Web of Science, Cochrane Central Register of Controlled Trials (CENTRAL), and clinicaltrials.gov were searched for studies from inception to September 10, 2023. The outcomes were accuracy of inclination and anteversion, duration of surgery, and intraoperative blood loss. Meta-analysis was performed using Review Manager 5.4 software.
RESULTS
A total of five studies with 396 patients were included in our study. The pooled results indicated AR-assisted THA had better accuracy of inclination and anteversion than conventional THA (SMD = - 0.51, 95% CI [- 0.96 to - 0.07], P = 0.02; SMD = - 0.96, 95% CI [- 1.19 to - 0.72], P < 0.00001), but duration of surgery and intraoperative blood loss were similar in the two groups.
CONCLUSION
This systematic review and meta-analysis found that AR-assisted THA had better accuracy of inclination and anteversion than conventional THA, but the duration of surgery and intraoperative blood loss were similar in the two groups. Based on the pooled results, we suggested that AR can provide more precise acetabular cup placement than conventional methods in THA.
Topics: Humans; Arthroplasty, Replacement, Hip; Augmented Reality; Blood Loss, Surgical; Acetabulum; Surgery, Computer-Assisted; Hip Prosthesis
PubMed: 38042852
DOI: 10.1186/s13018-023-04421-0 -
The Journal of Rheumatology Sep 2011Studies have suggested higher rates of perioperative and postoperative complications in smokers compared to nonsmokers. The objective of this systematic review was to... (Review)
Review
OBJECTIVE
Studies have suggested higher rates of perioperative and postoperative complications in smokers compared to nonsmokers. The objective of this systematic review was to assess the association of smoking and postoperative outcomes following total hip arthroplasty (THA) or total knee arthroplasty (TKA).
METHODS
A search of 6 databases (The Cochrane Library, Scopus, Proquest Dissertation abstracts, CINAHL, Ovid Medline, and Embase) was performed by a Cochrane librarian. All titles and abstracts were screened by 2 independent reviewers with expertise in performing systematic reviews. Studies were included if they were fully published reports that included smoking and any perioperative or postoperative clinical outcome in patients with TKA or THA.
RESULTS
A total of 21 studies were included for the review, of which 6 provided multivariable-adjusted analyses, 14 univariate analyses, and one statistical modeling. For most outcomes, results from 1-2 studies could be pooled. Current smokers were significantly more likely to have any postoperative complication (risk ratio 1.24, 95% CI 1.01 to 1.54) and death (risk ratio 1.63, 95% CI 1.06 to 2.51) compared to nonsmokers. Former smokers were significantly more likely to have any post-operative complication (risk ratio 1.32, 95% CI 1.05 to 1.66) and death (risk ratio 1.69, 95% CI 1.08 to 2.64) compared to nonsmokers.
CONCLUSION
This systematic review found that smoking is associated with significantly higher risk of postoperative complication and mortality following TKA or THA. Studies examining longterm consequences of smoking on implant survival and complications are needed. Smoking cessation may improve outcomes after THA or TKA.
Topics: Arthroplasty, Replacement, Hip; Arthroplasty, Replacement, Knee; Comorbidity; Humans; Postoperative Complications; Smoking; Treatment Outcome
PubMed: 21632674
DOI: 10.3899/jrheum.101221 -
Knee Surgery, Sports Traumatology,... Oct 2016There are few evidence-based recommendations on the most effective methods for diagnosing prosthetic joint infections (PJIs), and the potency of tests in relation to... (Review)
Review
PURPOSE
There are few evidence-based recommendations on the most effective methods for diagnosing prosthetic joint infections (PJIs), and the potency of tests in relation to each other also remains vague. This systematic review aimed to (1) identify systematic reviews reporting accuracies of available approaches for diagnosing PJI, (2) critically appraise their quality and bias, and (3) compare the available approaches in terms of accuracy for diagnosing PJI.
METHODS
PubMed and EMBASE databases were searched for meta-analyses reporting accuracies of different diagnostic modalities for PJIs. Thirteen systematic reviews met the inclusion and exclusion criteria, and their data were extracted and tabulated by two reviewers in duplicate and independent manners.
RESULTS
The 13 articles reported diagnostic accuracy from 278 clinical studies comprising 27,754 patients and evaluating 13 diagnostic tests grouped into 7 broad categories. Implant sonication had the highest positive likelihood ratio (17.2), followed by bacteriology (15.3) and synovial fluid differentiated cytology (13.3). The highest negative likelihood ratio was for interleukin (IL)-6 serum marker (0.03) followed by synovial fluid cytology and differentiation (0.12 and 0.13, respectively).
CONCLUSION
The diagnostic tests that are most likely to rule out PJI include serum IL-6, serum C-reactive protein, and synovial fluid cytology. On the other hand, the diagnostic test that is most likely to confirm PJI is implant sonication. Nuclear imaging showed low overall accuracy as diagnostic tests for PJI. The findings of this study could enable clinicians to confirm or rule out PJIs using the most accurate, rapid, least invasive, and cost-effective tools available, thereby enabling fast treatment before formation of resistant biofilms and degradation of patient conditions.
LEVEL OF EVIDENCE
Systematic review, Level IV.
Topics: Arthroplasty, Replacement; Bacterial Typing Techniques; C-Reactive Protein; Humans; Interleukin-6; Joint Prosthesis; Likelihood Functions; Prosthesis-Related Infections; Synovial Fluid
PubMed: 27377905
DOI: 10.1007/s00167-016-4230-y -
Clinical Orthopaedics and Related... Aug 2011Highly crosslinked polyethylene (HXLPE) was introduced to reduce wear and osteolysis in total joint arthroplasty. While many studies report wear and osteolysis... (Review)
Review
BACKGROUND
Highly crosslinked polyethylene (HXLPE) was introduced to reduce wear and osteolysis in total joint arthroplasty. While many studies report wear and osteolysis associated with HXLPE, analytical techniques, clinical study design and followup, HXLPE formulation and implant design characteristics, and patient populations differ substantially among investigations, complicating a unified perspective.
QUESTIONS/PURPOSES
Literature on first-generation HXLPE was summarized. We systematically reviewed the radiographic wear data and incidence of osteolysis for HXLPE in hip and knee arthroplasty.
METHODS
PubMed identified 391 studies; 28 met inclusion criteria for a weighted-averages analysis of two-dimensional femoral head penetration rates. To determine the incidence of osteolysis, we estimated a pooled odds ratio using a random-effects model.
RESULTS
Weighted-averages analyses of femoral head penetration rates in HXLPE liners and conventional UHMWPE liners resulted, respectively, in a mean two-dimensional linear penetration rate of 0.042 mm/year based on 28 studies (n=1503 hips) and 0.137 mm/year based on 18 studies (n=695 hips). The pooled odds ratio for the risk of osteolysis in HXLPE versus conventional liners was 0.13 (95% confidence interval, 0.06-0.27) among studies with minimum 5-year followup. We identified two clinical studies of HXLPE in TKA, preventing systematic analysis of outcomes.
CONCLUSIONS
HXLPE liner studies consistently report lower femoral head penetration and an 87% lower risk of osteolysis. Reduction in femoral head penetration or osteolysis risk is not established for large-diameter (>32 mm) metallic femoral heads or ceramic femoral heads of any size. Few studies document the clinical performance of HXLPE in knees.
Topics: Arthroplasty, Replacement, Hip; Arthroplasty, Replacement, Knee; Cross-Linking Reagents; Femur Head; Hip Prosthesis; Humans; Knee Prosthesis; Materials Testing; Osteolysis; Polyethylenes; Prosthesis Design; Prosthesis Failure
PubMed: 21431461
DOI: 10.1007/s11999-011-1872-4 -
BMC Musculoskeletal Disorders Feb 2018The effects of tranexamic acid (TXA) in the setting of shoulder arthroplasty are unclear. The objective of this study was to examine the effects of TXA in reducing the... (Meta-Analysis)
Meta-Analysis Review
BACKGROUND
The effects of tranexamic acid (TXA) in the setting of shoulder arthroplasty are unclear. The objective of this study was to examine the effects of TXA in reducing the need for blood transfusions and blood loss in patients undergoing primary total shoulder arthroplasty (TSA) and reverse total shoulder arthroplasty (RTSA).
METHODS
We conducted a systematic review and meta-analysis of randomized controlled trials (RCTs) and retrospective cohort studies (RCS) that compared outcomes of patients who did and did not receive TXA during TSA or RTSA. We searched Cochrane Central Register of Controlled Trials, EMBASE, and MEDLINE for relevant studies. We assessed the risk of bias of the included studies and calculated pooled risk estimates. The primary outcome was transfusion rate, and secondary outcomes were changes in hemoglobin, estimated total blood loss (ETBL), blood loss via drainage, operative time, hospital stay, overall complications, and thromboembolic events.
RESULTS
We identified 3 RCTs and 3 RCS including 677 patients with 680 shoulders (343 TXA and 337 non-TXA). The random-effects model meta-analysis showed that TXA group had a lower transfusion rate (risk ratio (RR) 0.34, 95% CI 0.14 to 0.79), less change in hemoglobin (mean difference (MD) -0.64 g/dl, 95% CI -0.81 to - 0.46), and reduced ETBL (MD -249.24 ml, 95% CI -338.74 to - 159.74). In patients with RTSA, the TXA group had a lower transfusion rate (RR 0.28, 95% CI 0.14 to 0.79), less ETBL (MD -249.15 ml, 95% CI -426.60 to - 71.70), less change in hemoglobin (MD - 0.64 g/dl, 95% CI -0.86 to - 0.42), and less blood loss via drainage (MD - 84.56 ml, 95% CI -145.72.14 to - 23.39) than non-TXA group.
CONCLUSIONS
The use of TXA in primary shoulder arthroplasty appears safe, and can reduce transfusion rate, changes in hemoglobin, and perioperative total blood loss, especially in patients with RTSA.
LEVEL OF EVIDENCE
Systematic Review and meta-analysis, III.
Topics: Antifibrinolytic Agents; Arthroplasty, Replacement, Shoulder; Blood Loss, Surgical; Blood Transfusion; Humans; Randomized Controlled Trials as Topic; Tranexamic Acid
PubMed: 29454385
DOI: 10.1186/s12891-018-1972-3 -
Journal of Orthopaedic Surgery (Hong... 2023(MAC) prosthetic joint infection (PJI) has been rarely reported.
BACKGROUND
(MAC) prosthetic joint infection (PJI) has been rarely reported.
METHODS
This study aimed to investigate the epidemiology and outcomes of MAC PJI. A systematic review of the literature regarding the MAC infection following total joint arthroplasty including hip and knee joint was performed. Multiple databases were searched for published English-written articles up to May 2023. Studies that reported cases of PJI by MAC were reviewed.
RESULTS
A total of 17 patients were identified and analyzed from 11 published studies. All patients presented with joint symptom of pain or swelling prior to the diagnosis and MAC was confirmed by culture. The most of the patients (16/17 patients, 94.1%) were noted to have underlying medical condition(s) that might have affected immunity. Treatment consisted of anti-MAC medication therapy only in two patients and anti-MAC medication therapy plus surgery in 15 patients. Among the patients who underwent surgery, 14 patients (82.3%) had removal of the prosthesis including seven patients who had two-stage surgery to have reimplantation of the prosthesis. No relapse of MAC infection was reported despite of one case of relapse of infection caused by different pyogenic bacteria. The rate of overall mortality was 29.4%, however, identified attributable mortality due to MAC infection was low (5.9%).
CONCLUSION
PJI by MAC is a rare disease. However, MAC needs to be considered in the differential diagnosis in immunocompromised patients presenting with symptoms of PJI. Two-stage exchange arthroplasty may result in successful treatment outcomes without higher risks of relapse of infection if undertaken in association with appropriate active anti-MAC antibiotic therapy.
Topics: Humans; Mycobacterium avium Complex; Arthroplasty, Replacement, Knee; Arthroplasty, Replacement, Hip; Mycobacterium avium-intracellulare Infection; Prostheses and Implants; Anti-Bacterial Agents; Arthritis, Infectious; Recurrence; Prosthesis-Related Infections; Retrospective Studies
PubMed: 37878458
DOI: 10.1177/10225536231199392 -
The Knee Dec 2023In recent years, kinematic alignment (KA) is becoming a valid alternative to mechanical alignment (MA) in total knee arthroplasty (TKA). However, to avoid early... (Review)
Review
BACKGROUND
In recent years, kinematic alignment (KA) is becoming a valid alternative to mechanical alignment (MA) in total knee arthroplasty (TKA). However, to avoid early failures, the restricted kinematic alignment (rKA) approach has been developed to restore native knee kinematics without reproducing extreme knee phenotype. This systematic review aims to evaluate clinical and radiological outcomes between rKA and MA for TKA.
METHODS
A systematic literature search was conducted following PRISMA guidelines on Pubmed, Scopus and Cochrane Library. The following search string was adopted: (((restricted kinematic) AND (mechanical)) AND (alignment)) AND (knee). We included studies that analyzed rKA versus MA in terms of clinical outcomes and complications with a minimum of 6 months of follow up. The following rKA- and MA-related data were evaluated: patient-reported outcome scores (PROMs), radiographic analysis of lower limb alignment, and complications. Criteria from the Methodological Index for Non-Randomized Studies were used to assess the methodological quality of the articles.
RESULTS
This systematic review included seven clinical studies with a total of 892 knees (471 for MA group and 421 for rKA group, respectively). Overall, post-operative PROMs were similar between rKA and MA. Moreover, rKA reached better results regarding Forgotten Joint Score and post-operative patient satisfaction. Finally, no higher complication rate was observed with the rKA approach.
CONCLUSION
The rKA aims to restore native knee kinematics, avoiding extreme deformities. Clinical outcomes are not inferior or even better for rKA compared with MA, without increasing the risk of short-middle-term implant failure. However, there is a high heterogeneity regarding the 'restricted' protocols used.
Topics: Humans; Biomechanical Phenomena; Arthroplasty, Replacement, Knee; Knee Joint; Lower Extremity; Radiography; Osteoarthritis, Knee; Knee Prosthesis
PubMed: 37925804
DOI: 10.1016/j.knee.2023.10.003 -
PloS One 2019The number of periprosthetic joint infections (PJI) after total knee arthroplasty (TKA) is increasing annually. Animal models have been used to clarify their clinical... (Meta-Analysis)
Meta-Analysis
BACKGROUND
The number of periprosthetic joint infections (PJI) after total knee arthroplasty (TKA) is increasing annually. Animal models have been used to clarify their clinical characteristics and the infection mechanism of pathogenic bacteria, However, since the prosthesis design of animal models is not uniform, it is difficult to simulate the environment of clinical PJI.
OBJECTIVES
To retrospect the progress on the prosthesis design of animal models of PJI after TKA and to summarize the criteria for evaluating a clinically representative model of PJI.
METHODS
This systematic review was reported on the basis of Systematic Reviews and Meta-Analyzes (PRISMA). Pubmed, EMbase, Cochrane Library, Web of Science, Wanfang Data and China National Knowledge Infrastructure were researched for animal models of PJI after TKA from database establishment to April 2019 according to Chinese and English retrieval words, including "periprosthetic joint infections and total knee arthroplasty," "periprosthetic joint infections and model," "periprosthetic joint infections and biofilm," and "total knee arthroplasty and model."
RESULTS
A total of 12 quantitative studies were enrolled in our study finally: 8 representative studies described prosthesis designs used in PJI animal models, 4 studies described prosthesis designs in non-infected animal models which were suitable for infection models. The major problems need to be dealed with were prosthesis, installation location, material, the function of separating the articular and medullary cavity, fixation manner, and the procedure of preserving the posterior cruciate ligament.
CONCLUSION
A highly representative design of the animal prosthesis of PJI should meet the following criteria: the surface of the prosthesis is smooth with the formation of biofilm, composed of titanium-6Al-4V or cobalt-chromium-molybdenum alloy; prosthesis can bear weight and is highly stable; and it can connect the joint cavity and medullary cavity simultaneously. To reach a more reliable conclusion, further experiments and improvements are required.
Topics: Animals; Arthritis, Infectious; Arthroplasty, Replacement, Knee; Disease Models, Animal; Humans; Printing, Three-Dimensional; Prosthesis Design; Prosthesis-Related Infections; Radiography; Retrospective Studies
PubMed: 31581252
DOI: 10.1371/journal.pone.0223402