Respiration; International Review of... 2022Prolonged mechanical ventilation (PMV) and weaning failure are factors associated with prolonged hospital length of stay and increased morbidity and mortality. In...
INTRODUCTION
Prolonged mechanical ventilation (PMV) and weaning failure are factors associated with prolonged hospital length of stay and increased morbidity and mortality. In addition to the burden these places on patients and their families, it also imposes high costs on the public health system. The aim of this systematic review was to identify risk factors for PMV and weaning failure.
METHODS
The study was conducted according to PRISMA guidelines. After a comprehensive search of the COCHRANE Library, CINHAL, Web of Science, MEDLINE, and the LILACS Database a PubMed request was made on June 8, 2020. Studies that examined risk factors for PMV, defined as mechanical ventilation ≥96 h, weaning failure, and prolonged weaning in German and English were considered eligible; reviews, meta-analyses, and studies in very specific patient populations whose results are not necessarily applicable to the majority of ICU patients as well as pediatric studies were excluded from the analysis. This systematic review was registered in the PROSPERO register under the number CRD42021271038.
RESULTS
Of 532 articles identified, 23 studies with a total of 23,418 patients met the inclusion criteria. Fourteen studies investigated risk factors of PMV including prolonged weaning, 9 studies analyzed risk factors of weaning failure. The concrete definitions of these outcomes varied considerably between studies. For PMV, a variety of risk factors were identified, including comorbidities, site of intubation, various laboratory or blood gas parameters, ventilator settings, functional parameters, and critical care scoring systems. The risk of weaning failure was mainly related to age, previous home mechanical ventilation (HMV), cause of ventilation, and preexisting underlying diseases. Elevated PaCO2 values during spontaneous breathing trials were indicative of prolonged weaning and weaning failure.
CONCLUSION
A direct comparison of risk factors was not possible because of the heterogeneity of the studies. The large number of different definitions and relevant parameters reflects the heterogeneity of patients undergoing PMV and those discharged to HMV after unsuccessful weaning. Multidimensional scores are more likely to reflect the full spectrum of patients ventilated in different ICUs than single risk factors.
Topics: Child; Critical Care; Humans; Intensive Care Units; Respiration, Artificial; Time Factors; Ventilator Weaning
PubMed: 35977525
DOI: 10.1159/000525604 -
Respiratory Care Feb 2022Artificial airway suctioning is a key component of airway management and a core skill for clinicians charged with assuring airway patency. Suctioning of the artificial...
Artificial airway suctioning is a key component of airway management and a core skill for clinicians charged with assuring airway patency. Suctioning of the artificial airway is a common procedure performed worldwide on a daily basis. As such, it is imperative that clinicians are familiar with the most-effective and efficient methods to perform the procedure. We conducted a systematic review to assist in the development of evidence-based recommendations that pertain to the care of patients with artificial airways. From our systematic review, we developed guidelines and recommendations that addressed questions related to the indications, complications, timing, duration, and methods of artificial airway suctioning. By using a modified version of the RAND/UCLA Appropriateness Method, the following recommendations for suctioning were developed for neonatal, pediatric, and adult patients with an artificial airway: (1) breath sounds, visual secretions in the artificial airway, and a sawtooth pattern on the ventilator waveform are indicators for suctioning pediatric and adult patients, and an acute increase in airway resistance may be an indicator for suctioning in neonates; (2) as-needed only, rather than scheduled, suctioning is sufficient for neonatal and pediatric patients; (3) both closed and open suction systems may be used to safely and effectively remove secretions from the artificial airway of adult patients; (4) preoxygenation should be performed before suctioning in pediatric and adult patients; (5) the use of normal saline solution should generally be avoided during suctioning; (6) during open suctioning, sterile technique should be used; (7) suction catheters should occlude < 70% of the endotracheal tube lumen in neonates and < 50% in pediatric and adult patients, and suction pressure should be kept below -120 mm Hg in neonatal and pediatric patients and -200 mm Hg in adult patients; (8) suction should be applied for a maximum of 15 s per suctioning procedure; (9) deep suctioning should only be used when shallow suctioning is ineffective; (10) routine bronchoscopy for secretion removal is not recommended; and (11) devices used to clear endotracheal tubes may be used when airway resistance is increased due to secretion accumulation.
Topics: Adult; Airway Management; Child; Humans; Infant, Newborn; Intubation, Intratracheal; Respiration, Artificial; Suction; Ventilators, Mechanical
PubMed: 35078900
DOI: 10.4187/respcare.09548 -
The Cochrane Database of Systematic... Dec 2020Ventilator-associated pneumonia (VAP) is defined as pneumonia developing in people who have received mechanical ventilation for at least 48 hours. VAP is a potentially... (Meta-Analysis)
Meta-Analysis
BACKGROUND
Ventilator-associated pneumonia (VAP) is defined as pneumonia developing in people who have received mechanical ventilation for at least 48 hours. VAP is a potentially serious complication in these patients who are already critically ill. Oral hygiene care (OHC), using either a mouthrinse, gel, swab, toothbrush, or combination, together with suction of secretions, may reduce the risk of VAP in these patients.
OBJECTIVES
To assess the effects of oral hygiene care (OHC) on incidence of ventilator-associated pneumonia in critically ill patients receiving mechanical ventilation in hospital intensive care units (ICUs).
SEARCH METHODS
Cochrane Oral Health's Information Specialist searched the following databases: Cochrane Oral Health's Trials Register (to 25 February 2020), the Cochrane Central Register of Controlled Trials (CENTRAL) (the Cochrane Library, 2020, Issue 1), MEDLINE Ovid (1946 to 25 February 2020), Embase Ovid (1980 to 25 February 2020), LILACS BIREME Virtual Health Library (1982 to 25 February 2020) and CINAHL EBSCO (1937 to 25 February 2020). We also searched the VIP Database (January 2012 to 8 March 2020). The US National Institutes of Health Trials Registry (ClinicalTrials.gov) and the World Health Organization International Clinical Trials Registry Platform were searched for ongoing trials. No restrictions were placed on the language or date of publication when searching the electronic databases.
SELECTION CRITERIA
We included randomised controlled trials (RCTs) evaluating the effects of OHC (mouthrinse, gel, swab, toothbrush or combination) in critically ill patients receiving mechanical ventilation for at least 48 hours.
DATA COLLECTION AND ANALYSIS
At least two review authors independently assessed search results, extracted data and assessed risk of bias in included studies. We contacted study authors for additional information. We reported risk ratio (RR) for dichotomous outcomes and mean difference (MD) for continuous outcomes, using the random-effects model of meta-analysis when data from four or more trials were combined.
MAIN RESULTS
We included 40 RCTs (5675 participants), which were conducted in various countries including China, USA, Brazil and Iran. We categorised these RCTs into five main comparisons: chlorhexidine (CHX) mouthrinse or gel versus placebo/usual care; CHX mouthrinse versus other oral care agents; toothbrushing (± antiseptics) versus no toothbrushing (± antiseptics); powered versus manual toothbrushing; and comparisons of other oral care agents used in OHC (other oral care agents versus placebo/usual care, or head-to-head comparisons between other oral care agents). We assessed the overall risk of bias as high in 31 trials and low in two, with the rest being unclear. Moderate-certainty evidence from 13 RCTs (1206 participants, 92% adults) shows that CHX mouthrinse or gel, as part of OHC, probably reduces the incidence of VAP compared to placebo or usual care from 26% to about 18% (RR 0.67, 95% confidence intervals (CI) 0.47 to 0.97; P = 0.03; I = 66%). This is equivalent to a number needed to treat for an additional beneficial outcome (NNTB) of 12 (95% CI 7 to 128), i.e. providing OHC including CHX for 12 ventilated patients in intensive care would prevent one patient developing VAP. There was no evidence of a difference between interventions for the outcomes of mortality (RR 1.03, 95% CI 0.80 to 1.33; P = 0.86, I = 0%; 9 RCTs, 944 participants; moderate-certainty evidence), duration of mechanical ventilation (MD -1.10 days, 95% CI -3.20 to 1.00 days; P = 0.30, I = 74%; 4 RCTs, 594 participants; very low-certainty evidence) or duration of intensive care unit (ICU) stay (MD -0.89 days, 95% CI -3.59 to 1.82 days; P = 0.52, I = 69%; 5 RCTs, 627 participants; low-certainty evidence). Most studies did not mention adverse effects. One study reported adverse effects, which were mild, with similar frequency in CHX and control groups and one study reported there were no adverse effects. Toothbrushing (± antiseptics) may reduce the incidence of VAP (RR 0.61, 95% CI 0.41 to 0.91; P = 0.01, I = 40%; 5 RCTs, 910 participants; low-certainty evidence) compared to OHC without toothbrushing (± antiseptics). There is also some evidence that toothbrushing may reduce the duration of ICU stay (MD -1.89 days, 95% CI -3.52 to -0.27 days; P = 0.02, I = 0%; 3 RCTs, 749 participants), but this is very low certainty. Low-certainty evidence did not show a reduction in mortality (RR 0.84, 95% CI 0.67 to 1.05; P = 0.12, I = 0%; 5 RCTs, 910 participants) or duration of mechanical ventilation (MD -0.43, 95% CI -1.17 to 0.30; P = 0.25, I = 46%; 4 RCTs, 810 participants).
AUTHORS' CONCLUSIONS
Chlorhexidine mouthwash or gel, as part of OHC, probably reduces the incidence of developing ventilator-associated pneumonia (VAP) in critically ill patients from 26% to about 18%, when compared to placebo or usual care. We did not find a difference in mortality, duration of mechanical ventilation or duration of stay in the intensive care unit, although the evidence was low certainty. OHC including both antiseptics and toothbrushing may be more effective than OHC with antiseptics alone to reduce the incidence of VAP and the length of ICU stay, but, again, the evidence is low certainty. There is insufficient evidence to determine whether any of the interventions evaluated in the studies are associated with adverse effects.
Topics: Adult; Child; Chlorhexidine; Critical Illness; Humans; Incidence; Intensive Care Units; Length of Stay; Mouthwashes; Oral Hygiene; Pneumonia, Ventilator-Associated; Randomized Controlled Trials as Topic; Respiration, Artificial; Toothbrushing
PubMed: 33368159
DOI: 10.1002/14651858.CD008367.pub4 -
Intensive Care Medicine Jun 2020The accuracy of the signs and tests that clinicians use to diagnose ventilator-associated pneumonia (VAP) and initiate antibiotic treatment has not been well... (Meta-Analysis)
Meta-Analysis Review
The accuracy of the signs and tests that clinicians use to diagnose ventilator-associated pneumonia (VAP) and initiate antibiotic treatment has not been well characterized. We sought to characterize and compare the accuracy of physical examination, chest radiography, endotracheal aspirate (ETA), bronchoscopic sampling cultures (protected specimen brush [PSB] and bronchoalveolar lavage [BAL]), and CPIS > 6 to diagnose VAP. We searched six databases from inception through September 2019 and selected English-language studies investigating accuracy of any of the above tests for VAP diagnosis. Reference standard was histopathological analysis. Two reviewers independently extracted data and assessed study quality. We included 25 studies (1639 patients). The pooled sensitivity and specificity of physical examination findings for VAP were poor: fever (66.4% [95% confidence interval [CI]: 40.7-85.0], 53.9% [95% CI 34.5-72.2]) and purulent secretions (77.0% [95% CI 64.7-85.9], 39.0% [95% CI 25.8-54.0]). Any infiltrate on chest radiography had a sensitivity of 88.9% (95% CI 73.9-95.8) and specificity of 26.1% (95% CI 15.1-41.4). ETA had a sensitivity of 75.7% (95% CI 51.5-90.1) and specificity of 67.9% (95% CI 40.5-86.8). Among bronchoscopic sampling methods, PSB had a sensitivity of 61.4% [95% CI 43.7-76.5] and specificity of 76.5% [95% CI 64.2-85.6]; while BAL had a sensitivity of 71.1% [95% CI 49.9-85.9] and specificity of 79.6% [95% CI 66.2-85.9]. CPIS > 6 had a sensitivity of 73.8% (95% CI 50.6-88.5) and specificity of 66.4% (95% CI 43.9-83.3). Classic clinical indicators had poor accuracy for diagnosis of VAP. Reliance upon these indicators in isolation may result in misdiagnosis and potentially unnecessary antimicrobial use.
Topics: Adult; Bronchoalveolar Lavage; Bronchoalveolar Lavage Fluid; Critical Illness; Humans; Pneumonia, Ventilator-Associated; Respiration, Artificial; Sensitivity and Specificity
PubMed: 32306086
DOI: 10.1007/s00134-020-06036-z -
Medicine Jun 2022The ABCDE (Awakening and Breathing Coordination of daily sedation and ventilator removal trials, Delirium monitoring and management, and Early mobility and exercise) and... (Meta-Analysis)
Meta-Analysis
BACKGROUND
The ABCDE (Awakening and Breathing Coordination of daily sedation and ventilator removal trials, Delirium monitoring and management, and Early mobility and exercise) and ABCDEF (Assessment, prevent and manage pain, Both spontaneous awakening and spontaneous breathing trials, Choice of analgesia and sedation, assess, prevent and manage Delirium, Early mobility and exercise, Family engagement) care bundles consist of small sets of evidence-based interventions and are part of the science behind Intensive Care Unit (ICU) liberation. This review sought to analyse the process of implementation of ABCDE and ABCDEF care bundles in ICUs, identifying barriers, facilitators and changes in perception and attitudes of healthcare professionals; and to estimate care bundle effectiveness and safety.
METHODS
We selected qualitative and quantitative studies addressing the implementation of ABCDE and ABCDEF bundles in the ICU, identified on MEDLINE, Embase, CINAHL, The Cochrane Library, Web of Science, Epistemonikos, PsycINFO, Virtual Health Library and Open Grey, without restriction on language or date of publication, up to June 2018. The outcomes measured were ICU and hospital length of stay; mechanical ventilation time; incidence and prevalence of delirium or coma; level of agitation and sedation; early mobilization; mortality in ICU and hospital; change in perception, attitude or behaviour of the stakeholders; and change in knowledge of health professionals. Two reviewers independently selected the studies, performed data extraction, and assessed risk of bias and methodological quality. A meta-analysis of random effects was performed.
RESULTS
Twenty studies were included, 13 of which had a predominantly qualitative and 7 a quantitative design (31,604 participants). The implementation strategies were categorized according to the taxonomy developed by the Cochrane Effective Practice and Organization of Care Group and eighty strategies were identified. The meta-analysis results showed that implementation of the bundles may reduce length of ICU stay, mechanical ventilation time, delirium, ICU and hospital mortality, and promoted early mobilization in critically-ill patients.
CONCLUSIONS
: This study can contribute to the planning and execution of the implementation process of ABCDE and ABCDEF care bundles in ICUs. However, the effectiveness and safety of these bundles need to be corroborated by further studies with greater methodological rigor.
PROTOCOL REGISTRATION
PROSPERO CRD42019121307.
Topics: Critical Care; Critical Illness; Delirium; Humans; Intensive Care Units; Patient Care Bundles
PubMed: 35758388
DOI: 10.1097/MD.0000000000029499 -
Critical Care (London, England) May 2023Several measurements have been used to predict the success of weaning from mechanical ventilation; however, their efficacy varies in different studies. In recent years,... (Meta-Analysis)
Meta-Analysis Review
BACKGROUND
Several measurements have been used to predict the success of weaning from mechanical ventilation; however, their efficacy varies in different studies. In recent years, diaphragmatic ultrasound has been used for this purpose. We conducted a systematic review and meta-analysis to evaluate the effectiveness of diaphragmatic ultrasound in predicting the success of weaning from mechanical ventilation.
METHODS
Two investigators independently searched PUBMED, TRIP, EMBASE, COCHRANE, SCIENCE DIRECT, and LILACS for articles published between January 2016 and July 2022. The methodological quality of the studies was assessed using the Quality Assessment of Diagnostic Accuracy Studies-2 tool; additionally, the certainty of the evidence is evaluated using the GRADE (Grading of Recommendations Assessment, Development, and Evaluation) methodology. Sensitivity and specificity analysis was performed for diaphragmatic excursion and diaphragmatic thickening fraction; positive and negative likelihood ratios and diagnostic odds ratios (DOR) with their confidence intervals (95% CI) were calculated by random effects analysis, summary receiver operating characteristic curve was estimated. Sources of heterogeneity were explored by subgroup analysis and bivariate meta-regression.
RESULTS
Twenty-six studies were included, of which 19 were included in the meta-analysis (1204 patients). For diaphragmatic excursion, sensitivity was 0.80 (95% CI 0.77-0.83), specificity 0.80 (95% CI 0.75-0.84), area under the summary receiver operating characteristic curve 0.87 and DOR 17.1 (95% CI 10.2-28.6). For the thickening fraction, sensitivity was 0.85 (95% CI 0.82-0.87), specificity 0.75 (95% CI 0.69-0.80), area under the summary receiver operating characteristic curve 0.87 and DOR 17.2 (95% CI 9.16-32.3). There was heterogeneity among the included studies. When performing a subgroup analysis and excluding studies with atypical cutoff values, sensitivity and specificity increased for diaphragmatic thickening fraction; sensitivity increased and specificity decreased for diaphragmatic excursion; when comparing studies using pressure support (PS) versus T-tube, there was no significant difference in sensitivity and specificity; bivariate meta-regression analysis shows that patient position at the time of testing was a factor of heterogeneity in the included studies.
CONCLUSIONS
Measurement of diaphragmatic excursion and diaphragmatic thickening fraction predict the probability of successful weaning from mechanical ventilation with satisfactory diagnostic accuracy; however, significant heterogeneity was evident in the different included studies. Studies of high methodological quality in specific subgroups of patients in intensive care units are needed to evaluate the role of diaphragmatic ultrasound as a predictor of weaning from mechanical ventilation.
Topics: Humans; Respiration, Artificial; Ventilator Weaning; Sensitivity and Specificity; ROC Curve; Intensive Care Units; Diaphragm; Ultrasonography
PubMed: 37147688
DOI: 10.1186/s13054-023-04430-9 -
Anaesthesiology Intensive Therapy 2022Proper timing for discontinuation of mechanical ventilation is of great importance, especially in patients with previous weaning failures. Different indices obtained by... (Meta-Analysis)
Meta-Analysis Review
Proper timing for discontinuation of mechanical ventilation is of great importance, especially in patients with previous weaning failures. Different indices obtained by ultra-sonographic evaluation of the diaphragm muscle have improved determination of weaning success. The aim of the present systematic review was to evaluate and compare the accuracy of the diagnostic indices obtained by ultrasonographic examination, including diaphragm thickening fraction (DTF), diaphragmatic excursion (DE) and the rapid shallow breathing index (RSBI). A systematic literature search (Web of Science, MEDLINE, Embase and Google Scholar) was performed to identify original articles assessing diaphragm muscle features including excursion and thickening fraction. A total of 2738 citations were retrieved initially; available data of 19 cohort studies (1114 patients overall) were included in the meta-analysis, subdivided into groups based on the ultrasonographic examination type. Our results showed the superiority of the diagnostic accuracy of the DTF in comparison to the DE and the RSBI. Data on the combination of the different indices are limited. Diaphragmatic ultrasound is a cheap and feasible tool for diaphragm function evaluation. Moreover, DTF in the assessment of weaning outcome provides more promising outcomes, which should be evaluated more meti-culously in future randomised trials.
Topics: Diaphragm; Humans; Prospective Studies; Respiration, Artificial; Ultrasonography; Ventilator Weaning
PubMed: 35792111
DOI: 10.5114/ait.2022.117273 -
The Cochrane Database of Systematic... Aug 2021Systemic corticosteroids are used to treat people with COVID-19 because they counter hyper-inflammation. Existing evidence syntheses suggest a slight benefit on... (Review)
Review
BACKGROUND
Systemic corticosteroids are used to treat people with COVID-19 because they counter hyper-inflammation. Existing evidence syntheses suggest a slight benefit on mortality. So far, systemic corticosteroids are one of the few treatment options for COVID-19. Nonetheless, size of effect, certainty of the evidence, optimal therapy regimen, and selection of patients who are likely to benefit most are factors that remain to be evaluated.
OBJECTIVES
To assess whether systemic corticosteroids are effective and safe in the treatment of people with COVID-19, and to keep up to date with the evolving evidence base using a living systematic review approach.
SEARCH METHODS
We searched the Cochrane COVID-19 Study Register (which includes PubMed, Embase, CENTRAL, ClinicalTrials.gov, WHO ICTRP, and medRxiv), Web of Science (Science Citation Index, Emerging Citation Index), and the WHO COVID-19 Global literature on coronavirus disease to identify completed and ongoing studies to 16 April 2021.
SELECTION CRITERIA
We included randomised controlled trials (RCTs) that evaluated systemic corticosteroids for people with COVID-19, irrespective of disease severity, participant age, gender or ethnicity. We included any type or dose of systemic corticosteroids. We included the following comparisons: systemic corticosteroids plus standard care versus standard care (plus/minus placebo), dose comparisons, timing comparisons (early versus late), different types of corticosteroids and systemic corticosteroids versus other active substances. We excluded studies that included populations with other coronavirus diseases (severe acute respiratory syndrome or Middle East respiratory syndrome), corticosteroids in combination with other active substances versus standard care, topical or inhaled corticosteroids, and corticosteroids for long-COVID treatment.
DATA COLLECTION AND ANALYSIS
We followed standard Cochrane methodology. To assess the risk of bias in included studies, we used the Cochrane 'Risk of bias' 2 tool for RCTs. We rated the certainty of evidence using the GRADE approach for the following outcomes: all-cause mortality, ventilator-free days, new need for invasive mechanical ventilation, quality of life, serious adverse events, adverse events, and hospital-acquired infections.
MAIN RESULTS
We included 11 RCTs in 8075 participants, of whom 7041 (87%) originated from high-income countries. A total of 3072 participants were randomised to corticosteroid arms and the majority received dexamethasone (n = 2322). We also identified 42 ongoing studies and 16 studies reported as being completed or terminated in a study registry, but without results yet. Hospitalised individuals with a confirmed or suspected diagnosis of symptomatic COVID-19 Systemic corticosteroids plus standard care versus standard care plus/minus placebo We included 10 RCTs (7989 participants), one of which did not report any of our pre-specified outcomes and thus our analysis included outcome data from nine studies. All-cause mortality (at longest follow-up available): systemic corticosteroids plus standard care probably reduce all-cause mortality slightly in people with COVID-19 compared to standard care alone (median 28 days: risk difference of 30 in 1000 participants fewer than the control group rate of 275 in 1000 participants; risk ratio (RR) 0.89, 95% confidence interval (CI) 0.80 to 1.00; 9 RCTs, 7930 participants; moderate-certainty evidence). Ventilator-free days: corticosteroids may increase ventilator-free days (MD 2.6 days more than control group rate of 4 days, 95% CI 0.67 to 4.53; 1 RCT, 299 participants; low-certainty evidence). Ventilator-free days have inherent limitations as a composite endpoint and should be interpreted with caution. New need for invasive ventilation: the evidence is of very low certainty. Because of high risk of bias arising from deaths that occurred before ventilation we are uncertain about the size and direction of the effects. Consequently, we did not perform analysis beyond the presentation of descriptive statistics. Quality of life/neurological outcome: no data were available. Serious adverse events: we included data on two RCTs (678 participants) that evaluated systemic corticosteroids compared to standard care (plus/minus placebo); for adverse events and hospital-acquired infections, we included data on five RCTs (660 participants). Because of high risk of bias, heterogeneous definitions, and underreporting we are uncertain about the size and direction of the effects. Consequently, we did not perform analysis beyond the presentation of descriptive statistics (very low-certainty evidence). Different types, dosages or timing of systemic corticosteroids We identified one study that compared methylprednisolone with dexamethasone. The evidence for mortality and new need for invasive mechanical ventilation is very low certainty due to the small number of participants (n = 86). No data were available for the other outcomes. We did not identify comparisons of different dosages or timing. Outpatients with asymptomatic or mild disease Currently, there are no studies published in populations with asymptomatic infection or mild disease.
AUTHORS' CONCLUSIONS
Moderate-certainty evidence shows that systemic corticosteroids probably slightly reduce all-cause mortality in people hospitalised because of symptomatic COVID-19. Low-certainty evidence suggests that there may also be a reduction in ventilator-free days. Since we are unable to adjust for the impact of early death on subsequent endpoints, the findings for ventilation outcomes and harms have limited applicability to inform treatment decisions. Currently, there is no evidence for asymptomatic or mild disease (non-hospitalised participants). There is an urgent need for good-quality evidence for specific subgroups of disease severity, for which we propose level of respiratory support at randomisation. This applies to the comparison or subgroups of different types and doses of corticosteroids, too. Outcomes apart from mortality should be measured and analysed appropriately taking into account confounding through death if applicable. We identified 42 ongoing and 16 completed but not published RCTs in trials registries suggesting possible changes of effect estimates and certainty of the evidence in the future. Most ongoing studies target people who need respiratory support at baseline. With the living approach of this review, we will continue to update our search and include eligible trials and published data.
Topics: Adrenal Cortex Hormones; COVID-19; Humans; Immunization, Passive; Randomized Controlled Trials as Topic; Respiration, Artificial; SARS-CoV-2; COVID-19 Drug Treatment
PubMed: 34396514
DOI: 10.1002/14651858.CD014963 -
The Cochrane Database of Systematic... Oct 2015Adults in intensive care units (ICUs) often suffer from a lack of sleep or frequent sleep disruptions. Non-pharmacological interventions can improve the duration and... (Meta-Analysis)
Meta-Analysis Review
BACKGROUND
Adults in intensive care units (ICUs) often suffer from a lack of sleep or frequent sleep disruptions. Non-pharmacological interventions can improve the duration and quality of sleep and decrease the risk of sleep disturbance, delirium, post-traumatic stress disorder (PTSD), and the length of stay in the ICU. However, there is no clear evidence of the effectiveness and harms of different non-pharmacological interventions for sleep promotion in adults admitted to the ICU.
OBJECTIVES
To assess the efficacy of non-pharmacological interventions for sleep promotion in critically ill adults in the ICU.To establish whether non-pharmacological interventions are safe and clinically effective in improving sleep quality and reducing length of ICU stay in critically ill adults.To establish whether non-pharmacological interventions are cost effective.
SEARCH METHODS
We searched the Cochrane Central Register of Controlled Trials (CENTRAL, 2014, Issue 6), MEDLINE (OVID, 1950 to June 2014), EMBASE (1966 to June 2014), CINAHL (Cumulative Index to Nursing and Allied Health Literature, 1982 to June 2014), Institute for Scientific Information (ISI) Web of Science (1956 to June 2014), CAM on PubMed (1966 to June 2014), Alt HealthWatch (1997 to June 2014), PsycINFO (1967 to June 2014), the China Biological Medicine Database (CBM-disc, 1979 to June 2014), and China National Knowledge Infrastructure (CNKI Database, 1999 to June 2014). We also searched the following repositories and registries to June 2014: ProQuest Dissertations & Theses Global, the US National Institutes of Health Ongoing Trials Register (www.clinicaltrials.gov), the metaRegister of Controlled Trials (ISRCTN Register) (www.controlled-trials.com), the Chinese Clinical Trial Registry (www.chictr.org.cn), the Clinical Trials Registry-India (www.ctri.nic.in), the Grey Literature Report from the New York Academy of Medicine Library (www.greylit.org), OpenGrey (www.opengrey.eu), and the World Health Organization International Clinical Trials Registry platform (www.who.int/trialsearch). We handsearched critical care journals and reference lists and contacted relevant experts to identify relevant unpublished data.
SELECTION CRITERIA
We included all randomized controlled trials (RCT) and quasi-RCTs that evaluated the effects of non-pharmacological interventions for sleep promotion in critically ill adults (aged 18 years and older) during admission to critical care units or ICUs.
DATA COLLECTION AND ANALYSIS
Two authors independently screened the search results and assessed the risk of bias in selected trials. One author extracted the data and a second checked the data for accuracy and completeness. Where possible, we combined results in meta-analyses using mean differences and standardized mean differences for continuous outcomes and risk ratios for dichotomous outcomes. We used post-test scores in this review.
MAIN RESULTS
We included 30 trials, with a total of 1569 participants, in this review. We included trials of ventilator mode or type, earplugs or eye masks or both, massage, relaxation interventions, foot baths, music interventions, nursing interventions, valerian acupressure, aromatherapy, and sound masking. Outcomes included objective sleep outcomes, subjective sleep quality and quantity, risk of delirium, participant satisfaction, length of ICU stay, and adverse events. Clinical heterogeneity (e.g., participant population, outcomes measured) and research design limited quantitative synthesis, and only a small number of studies were available for most interventions. The quality of the evidence for an effect of non-pharmacological interventions on any of the outcomes examined was generally low or very low. Only three trials, all of earplugs or eye masks or both, provided data suitable for two separate meta-analyses. These meta-analyses, each of two studies, showed a lower incidence of delirium during ICU stay (risk ratio 0.55, 95% confidence interval (CI) 0.38 to 0.80, P value = 0.002, two studies, 177 participants) and a positive effect of earplugs or eye masks or both on total sleep time (mean difference 2.19 hours, 95% CI 0.41 to 3.96, P value = 0.02, two studies, 116 participants); we rated the quality of the evidence for both of these results as low.There was also some low quality evidence that music (350 participants; four studies) may improve subjective sleep quality and quantity, but we could not pool the data. Similarly, there was some evidence that relaxation techniques, foot massage, acupressure, nursing or social intervention, and sound masking can provide small improvements in various subjective measures of sleep quality and quantity, but the quality of the evidence was low. The effects of non-pharmacological interventions on objective sleep outcomes were inconsistent across 16 studies (we rated the quality of the evidence as very low): the majority of studies relating to the use of earplugs and eye masks found no benefit; results from six trials of ventilator modes suggested that certain ventilator settings might offer benefits over others, although the results of the individual trials did not always agree with each other. Only one study measured length of stay in the ICU and found no significant effect of earplugs plus eye masks. No studies examined the effect of any non-pharmacological intervention on mortality, risk of post-traumatic stress disorder, or cost-effectiveness; the included studies did not clearly report adverse effects, although there was very low quality evidence that ventilator mode influenced the incidence of central apnoeas and patient-ventilator asynchronies.
AUTHORS' CONCLUSIONS
The quality of existing evidence relating to the use of non-pharmacological interventions for promoting sleep in adults in the ICU was low or very low. We found some evidence that the use of earplugs or eye masks or both may have beneficial effects on sleep and the incidence of delirium in this population, although the quality of the evidence was low. Further high-quality research is needed to strengthen the evidence base.
Topics: Adult; Delirium; Ear Protective Devices; Eye Protective Devices; Humans; Intensive Care Units; Length of Stay; Music; Randomized Controlled Trials as Topic; Sleep; Sleep Wake Disorders; Ventilators, Mechanical
PubMed: 26439374
DOI: 10.1002/14651858.CD008808.pub2 -
The Cochrane Database of Systematic... Oct 2017Damage caused by lung overdistension (volutrauma) has been implicated in the development of bronchopulmonary dysplasia (BPD). Modern neonatal ventilation modes can... (Meta-Analysis)
Meta-Analysis Review
BACKGROUND
Damage caused by lung overdistension (volutrauma) has been implicated in the development of bronchopulmonary dysplasia (BPD). Modern neonatal ventilation modes can target a set tidal volume as an alternative to traditional pressure-limited ventilation (PLV) using a fixed inflation pressure. Volume-targeted ventilation (VTV) aims to produce a more stable tidal volume in order to reduce lung damage and stabilise the partial pressure of carbon dioxide (pCO).
OBJECTIVES
To determine whether VTV compared with PLV leads to reduced rates of death and death or BPD in newborn infants and to determine whether use of VTV affected outcomes including air leak, cranial ultrasound findings and neurodevelopment.
SEARCH METHODS
We used the standard search strategy of Cochrane Neonatal to search the Cochrane Central Register of Controlled Trials (CENTRAL 2016, Issue 12), MEDLINE via PubMed (1966 to 13 January 2017), Embase (1980 to 13 January 2017) and CINAHL (1982 to 13 January 2017). We also searched clinical trials databases, conference proceedings and the reference lists of retrieved articles for randomised controlled trials and quasi-randomised trials. We contacted the principal investigators of studies to obtain supplementary information.
SELECTION CRITERIA
Randomised and quasi-randomised trials comparing VTV versus PLV in infants of less than 44 weeks' postmenstrual age and reporting clinically relevant outcomes.
DATA COLLECTION AND ANALYSIS
We assessed risk of bias for each trial using Cochrane methodology. We evaluated quality of evidence for each outcome using GRADE criteria. We tabulated mortality, rates of BPD, short-term clinical outcomes and long-term developmental outcomes.
STATISTICS
for categorical outcomes, we calculated typical estimates for risk ratios (RR), risk differences (RD) and number needed to treat for an additional beneficial outcome (NNTB). For continuous variables, we calculated typical estimates for mean differences (MD). We used 95% confidence intervals (CI) and assumed a fixed-effect model for meta-analysis.
MAIN RESULTS
Twenty randomised trials met our inclusion criteria; 16 parallel trials (977 infants) and four cross-over trials (88 infants). No studies were blinded and the quality of evidence for outcomes assessed varied from moderate to low.We found no difference in the primary outcome, death before hospital discharge, between VTV modes versus PLV modes (typical RR 0.75, 95% CI 0.53 to 1.07; low quality evidence). However, there was moderate quality evidence that the use of VTV modes resulted in a reduction in the primary outcome, death or BPD at 36 weeks' gestation (typical RR 0.73, 95% CI 0.59 to 0.89; typical NNTB 8, 95% CI 5 to 20) and the following secondary outcomes: rates of pneumothorax (typical RR 0.52, 95% CI 0.31 to 0.87; typical NNTB 20, 95% CI 11 to 100), mean days of mechanical ventilation (MD -1.35 days, 95% CI -1.83 to -0.86), rates of hypocarbia (typical RR 0.49, 95% CI 0.33 to 0.72; typical NNTB 3, 95% CI 2 to 5), rates of grade 3 or 4 intraventricular haemorrhage (typical RR 0.53, 95% CI 0.37 to 0.77; typical NNTB 11, 95% CI 7 to 25) and the combined outcome of periventricular leukomalacia with or without grade 3 or 4 intraventricular haemorrhage (typical RR 0.47, 95% CI 0.27 to 0.80; typical NNTB 11, 95% CI 7 to 33). VTV modes were not associated with any increased adverse outcomes.
AUTHORS' CONCLUSIONS
Infants ventilated using VTV modes had reduced rates of death or BPD, pneumothoraces, hypocarbia, severe cranial ultrasound pathologies and duration of ventilation compared with infants ventilated using PLV modes. Further studies are needed to identify whether VTV modes improve neurodevelopmental outcomes and to compare and refine VTV strategies.
Topics: Bronchopulmonary Dysplasia; Humans; Infant, Newborn; Infant, Premature; Intermittent Positive-Pressure Ventilation; Pressure; Randomized Controlled Trials as Topic; Tidal Volume
PubMed: 29039883
DOI: 10.1002/14651858.CD003666.pub4