Plastic and Reconstructive Surgery.... May 2023Orbital fractures constitute a significant percentage of all midface injuries. Here, we present a contemporary evidence-based review of the major surgical approaches for... (Review)
Review
UNLABELLED
Orbital fractures constitute a significant percentage of all midface injuries. Here, we present a contemporary evidence-based review of the major surgical approaches for orbital wall fractures and analyze the literature to compare all major surgical procedures and their complication rates.
METHOD
A systematic review was conducted to compare surgical approaches (subciliary, transcaruncular, transconjunctival, subtarsal, and endoscopic) and postoperative complications in patients who underwent surgical fixation of orbital wall fractures. A database search in PubMed (PubMed Central, MEDLINE and Bookshelf) was performed for all articles containing the terms "orbital," "wall," "fracture," and "surgery" with different combinations.
RESULTS
A total of 950 articles were obtained and 25 articles were included, representing an analysis of 1137 fractures. The most frequent surgical approach was the endoscopic (33.3%) followed by the external surgical approaches, specifically transconjunctival (32.8%), subciliary (13.5%), subtarsal (11.5%), and transcaruncular (8.9%). The transconjunctival approach had a statistically significantly higher rate of complications (36.19%), followed by the subciliary (21.4%), and endoscopic approach (20.2%, < 0.0001). The subtarsal approach had a statistically significantly lower rate of complications (8.2%) followed by the transcaruncular approach (14.0%, < 0.0001).
CONCLUSION
The subtarsal and transcaruncular approaches were observed to have the lowest rates of complications, whereas the transconjunctival, subciliary, and endoscopic approaches were reported to have higher rates of complications.
PubMed: 37197012
DOI: 10.1097/GOX.0000000000004967 -
International Journal of Oral and... Jun 2022Computed tomography (CT) is commonly used for the diagnosis, treatment planning, and prognosis of pure orbital fractures of the orbital floor and medial wall. The aim of... (Review)
Review
Computed tomography (CT) is commonly used for the diagnosis, treatment planning, and prognosis of pure orbital fractures of the orbital floor and medial wall. The aim of this study was to systematically review the current literature in order to establish an overview of CT parameters relevant to the choice of treatment and (long-term) clinical outcome for patients treated operatively and conservatively. The PRISMA guidelines were followed. Databases were searched using the terms 'orbital fracture' and 'computed tomography'. Studies evaluating the relationship between CT parameters and the treatment decision or clinical outcome (enophthalmos, diplopia, and/or limitation of ocular movement) were included. The search yielded 4448 results of which 31 were included (except for three, all were retrospective). The systematic use of CT imaging in orbital fractures of the floor and the medial wall can be of great value in the treatment decision and prediction of (long-term) clinical outcomes for both conservatively and surgically treated patients. The following parameters were found to be the most relevant: fracture size, fracture location, orbital volume, soft tissue involvement, and craniocaudal dimension. Although some show great individual potential, it is likely that incorporating all parameters into an algorithm will provide the best predictive power and thus would be the most practically applicable tool.
Topics: Diplopia; Enophthalmos; Humans; Orbital Fractures; Retrospective Studies; Tomography, X-Ray Computed; Treatment Outcome
PubMed: 34696942
DOI: 10.1016/j.ijom.2021.10.001 -
Journal of Stomatology, Oral and... Jun 2024This systematic review and meta-analysis aimed to review the recent literature on the technical accuracy of surgical navigation for patient-specific reconstruction of... (Meta-Analysis)
Meta-Analysis
OBJECTIVE
This systematic review and meta-analysis aimed to review the recent literature on the technical accuracy of surgical navigation for patient-specific reconstruction of orbital fractures using a patient-specific implant, and to compare surgical navigation with conventional techniques.
MATERIALS AND METHODS
A systematic literature search was conducted in PubMed (Medline), Embase, Web of Science, and Cochrane (Core Collection) databases on May 16, 2023. Literature comparing surgical navigation with a conventional method using postoperative three-dimensional computed tomography imaging was collected. Only articles that studied at least one of the following outcomes were included: technical accuracy (angular accuracy, linear accuracy, volumetric accuracy, and degree of enophthalmos), preoperative and perioperative times, need for revision, complications, and total cost of the intervention. MINORS criteria were used to evaluate the quality of the articles.
RESULTS
After screening 3733 articles, 696 patients from 27 studies were included. A meta-analysis was conducted to evaluate volumetric accuracy and revision rates. Meta-analysis proved a significant better volumetric accuracy (0.93 cm ± 0.47 cm) when surgical navigation was used compared with conventional surgery (2.17 cm ± 1.35 cm). No meta-analysis of linear accuracy, angular accuracy, or enophthalmos was possible due to methodological heterogeneity. Surgical navigation had a revision rate of 4.9%, which was significantly lower than that of the conventional surgery (17%). Costs were increased when surgical navigation was used.
CONCLUSION
Studies with higher MINORS scores demonstrated enhanced volumetric precision compared with traditional approaches. Surgical navigation has proven effective in reducing revision rates compared to conventional approaches, despite increased costs.
Topics: Humans; Orbital Fractures; Surgery, Computer-Assisted; Plastic Surgery Procedures; Tomography, X-Ray Computed; Imaging, Three-Dimensional
PubMed: 37951500
DOI: 10.1016/j.jormas.2023.101683 -
Oral and Maxillofacial Surgery Jun 2023The purpose of this study is to execute an evidence-based review answering the following question (PICO): "Do patient-specific implants (PSI), manufactured or designed... (Meta-Analysis)
Meta-Analysis Review
The purpose of this study is to execute an evidence-based review answering the following question (PICO): "Do patient-specific implants (PSI), manufactured or designed using computer-assisted technology, improve outcomes (orbital volume change, enophthalmos, diplopia, and operative duration) compared to conventional methods in orbital reconstruction following traumatic orbital injury in the adult patient population?" We performed a systematic review and meta-analysis in accordance with PRISMA guidelines. Inclusion criteria included any comparative paper whereby computer-assisted technology was used in the prefabrication or design process of implants for use in post-traumatic orbital reconstruction. Paediatric patient populations were excluded. Eight databases were systematically searched for relevant studies. Risk of bias was assessed through the NOS and RoB2 tools. Random-effects models were used to identify differences in outcomes between groups where possible. Analysis was performed using R 4.0.0. Eleven of 4784 identified studies were included, comprising 628 adult patients, with 302 and 326 patients in the patient-specific and conventional groups, respectively. Weighted mean difference between unaffected and post-operative orbital volume was 0.32 ml (SD 0.75) and 0.95 ml (SD 1.03) for patient-specific and conventional groups, respectively. Significant improvement was identified in post-operative orbital volume reconstitution with the use of PSI, compared to conventional implants, in 3 of the 5 reporting studies. Equally, post-operative enophthalmos trended towards lower severity in the patient-specific group, with 11.2% of patients affected in the patient-specific group and 19.2% in the conventional group, and operative duration was significantly reduced with the use of PSI in 3 of the 6 reporting studies. Despite a tendency to favour PSI, no statistically significant differences in key outcomes were identified on meta-analysis. Although there is some encouraging data to support improved outcomes with the use of patient-specific orbital implants in post-traumatic reconstruction, there is, at present, no statistically significant evidence to objectively support their use over conventional implants based on the currently available comparative studies. Based on the results of this study, the choice of implant used should, thus, be left to the discretion of the surgeon.
Topics: Adult; Child; Humans; Enophthalmos; Orbit; Dental Implants; Orbital Fractures
PubMed: 35589881
DOI: 10.1007/s10006-022-01074-x -
Journal of Clinical Medicine May 2023This study aimed to perform a systematic review and meta-analysis to compare pre-shaped implants on a patient-specific 3D-printed (3DP) model to manual free-hand shaping... (Review)
Review
Is the Pre-Shaping of an Orbital Implant on a Patient-Specific 3D-Printed Model Advantageous Compared to Conventional Free-Hand Shaping? A Systematic Review and Meta-Analysis.
This study aimed to perform a systematic review and meta-analysis to compare pre-shaped implants on a patient-specific 3D-printed (3DP) model to manual free-hand shaping (MFS) for orbital wall reconstruction. The PRISMA protocol was followed in this study, and the review was registered in the PROSPERO database (CRD42021261594). A search was conducted in MEDLINE (PubMed), Embase, Cochrane Library, Clinicaltrials.gov, Google Scholar, and the grey literature. Ten articles were included, and six outcomes were analyzed. In total, 281 patients were in the 3DP group and 283 were in the MFS group. The studies had an overall high risk of bias. 3DP models resulted in a better accuracy of fit, anatomical angle reproduction, and defect area coverage. The correction of orbital volume was also superior with statistical significance. There was a higher percentage of the correction of enophthalmos and diplopia in the 3DP group. Intraoperative bleeding and hospital stay were reduced in the 3DP group. The meta-analysis of operative time showed a reduction in the average operative time by 23.58 min (95% CI: -43.98 to -3.19), which was statistically significant (t(6) = -2.8299, = 0.0300). The 3DP models appear advantageous for an accurate orbital wall reconstruction, with fewer complications than those for conventional free-hand-shaped implants.
PubMed: 37240532
DOI: 10.3390/jcm12103426 -
Annals of Medicine and Surgery (2012) Feb 2024Fractures of the orbit are common injuries within the maxillofacial skeleton, and can often result in restrictions to ocular movement, diplopia, and enophthalmous if... (Review)
Review
INTRODUCTION
Fractures of the orbit are common injuries within the maxillofacial skeleton, and can often result in restrictions to ocular movement, diplopia, and enophthalmous if herniation of globe content occurs. Various studies have demonstrated the use of autologous cartilage grafts in the reconstruction of orbital fractures.
METHODS
A systematic review protocol was registered with PROSPERO, and reported in accordance with the Preferred Reporting for Items for Systematic Reviews and Meta-Analyses. Comprehensive electronic search strategies of four databases were developed. Studies were screened according to the inclusion and exclusion criteria by two independent reviewers.
RESULTS
Seven thousand one hundred seventy-one articles were identified following a comprehensive literature search. These articles were filtered for relevance and duplication, which reduced the number of articles to 16. A total of 259 patients underwent orbital reconstruction with the use of autologous cartilage. Conchal cartilage was harvested in 148 patients, auricular cartilage in 22 patients, nasoseptal cartilage in 72 patients, and costal cartilage in 17 patients. Thirty, seven, twelve, and four complications were observed in patients where cartilage was harvested from the concha, auricle, nasoseptum and rib, respectively. Most common complications included diplopia (=23), infra-orbital para/anaesthesia (=27), and enophthalmos (=7). No failure of graft or donor site morbidity were observed in the studies.
CONCLUSION
Autogenous materials such as cartilage can be used as an alternative for orbital reconstruction. Cartilage was considered by the authors to provide adequate structural support to the orbital contents, and that it was easy to harvest, shape, and position.
PubMed: 38333240
DOI: 10.1097/MS9.0000000000001598 -
Journal of Clinical Medicine Aug 2023This systematic review summarizes recent literature on the use of extended reality, including augmented reality (AR), mixed reality (MR), and virtual reality (VR), in... (Review)
Review
BACKGROUND
This systematic review summarizes recent literature on the use of extended reality, including augmented reality (AR), mixed reality (MR), and virtual reality (VR), in preoperative planning for orbital fractures.
METHODS
A systematic search was conducted in PubMed, Embase, Web of Science and Cochrane on 6 April 2023. The included studies compared extended reality with conventional planning techniques, focusing on computer-aided surgical simulation based on Computed Tomography data, patient-specific implants (PSIs), fracture reconstruction of the orbital complex, and the use of extended reality. Outcomes analyzed were technical accuracy, planning time, operative time, complications, total cost, and educational benefits.
RESULTS
A total of 6381 articles were identified. Four articles discussed the educational use of VR, while one clinical prospective study examined AR for assisting orbital fracture management.
CONCLUSION
AR was demonstrated to ameliorate the accuracy and precision of the incision and enable the better identification of deep anatomical tissues in real time. Consequently, intraoperative imaging enhancement helps to guide the orientation of the orbital reconstruction plate and better visualize the precise positioning and fixation of the PSI of the fractured orbital walls. However, the technical accuracy of 2-3 mm should be considered. VR-based educational tools provided better visualization and understanding of craniofacial trauma compared to conventional 2- or 3-dimensional images.
PubMed: 37629251
DOI: 10.3390/jcm12165203 -
Journal of Stomatology, Oral and... Nov 2022This systematic review aims to investigate the effect of virtual planning on the treatment of zygomaticomaxillary complex (ZMC) traumatology followed by intraoperative...
OBJECTIVE
This systematic review aims to investigate the effect of virtual planning on the treatment of zygomaticomaxillary complex (ZMC) traumatology followed by intraoperative navigation. Furthermore, clinical outcomes following intraoperative navigation surgery or conventional surgery will be compared.
MATERIALS AND METHODS
A systematic literature search was conducted in PubMed, Embase, Web-of-Science, and Cochrane on January 1st, 2022. Inclusion criteria were articles using preoperative three-dimensional (3D) virtual planning combined with intraoperative navigation or comparing these 3D methods with conventional methods. Furthermore, at least one of the following outcomes needed to be included in the article: technical accuracy of the procedure, preoperative planning time, operative time, number of fixation points, patient satisfaction, complications, or total costs of the intervention.
RESULTS
Following the screening of 4478 articles, 17 were included. Five articles appeared to indicate a significantly better technical linear accuracy, one article reported better accuracy for rotation and two articles showed better accuracy in restoring orbital volume when using navigation. Nine articles investigated operative time with varying results. Seven articles calculated the additional costs, of which three concluded no extra cost while the others indicated high additional costs or questionable cost-effectiveness.
CONCLUSION
Virtual planning and intraoperative navigation technologies have the potential to assist maxillofacial trauma surgeons in reducing ZMC fractures significantly more accurately and restoring the facial contour in a less invasive manner at an acceptable cost.
REGISTRATION
The protocol for this systematic review (CRD42020216717) was registered in the International Prospective Register of Systematic Reviews (PROSPERO).
Topics: Humans; Zygomatic Fractures
PubMed: 35809796
DOI: 10.1016/j.jormas.2022.07.003 -
Journal of Clinical Medicine Jul 2023To assess the difference between preformed anatomically shaped osteosynthesis plates and patient-specific implants versus conventional flat plates for the treatment of... (Review)
Review
PURPOSE
To assess the difference between preformed anatomically shaped osteosynthesis plates and patient-specific implants versus conventional flat plates for the treatment of skeletal fractures in terms of anatomical reduction, operation time, approach, patient outcomes, and complications.
MATERIAL AND METHODS
MEDLINE (1950 to February 2023), EMBASE (1966 to February 2023), and the Cochrane Central Register of Controlled Trials (inception to February 2023) databases were searched. Eligible studies were randomised clinical trials, prospective controlled clinical trials, and prospective and retrospective cohort studies ( ≥ 10). Inclusion criteria were studies reporting the outcomes of preformed anatomically shaped osteosynthesis plates and patient-specific implants versus conventional flat plates after treating skeletal fractures. Outcome measures included anatomical reduction, stability, operation time, hospitalisation days, patients' outcomes, and complications. Two independent reviewers assessed the abstracts and analysed the complete texts and methodologies of the included studies.
RESULTS
In total, 21 out of the 5181 primarily selected articles matched the inclusion criteria. A meta-analysis revealed a significant difference in operation time in favour of the preformed anatomical plates and patient-specific implants versus conventional plates. Significant differences in operation time were found for the orbital (95% CI: -50.70-7.49, = 0.008), upper limb (95% CI: -17.91-6.13, < 0.0001), and lower limb extremity groups (95% CI: -20.40-15.11, < 0.00001). The mean difference in the rate of anatomical reduction in the lower limb extremity group (95% CI: 1.04-7.62, = 0.04) was also in favour of using preformed anatomical plates and patient-specific implants versus conventional plates.
CONCLUSIONS
This systematic review showed a significant mean difference in surgery time favouring the use of preformed anatomical plates and patient-specific implants for orbital, upper, and lower limb extremity fractures. Additionally, preformed anatomical plates and patient-specific implants in the lower limb group result in a significantly higher rate of anatomical reduction versus conventional flat plates.
PubMed: 37510776
DOI: 10.3390/jcm12144661