BMC Medical Informatics and Decision... Nov 2022With the availability of several similar medical devices performing the same function, choosing one for reimbursement is not easy, especially if purchased for a large...
BACKGROUND
With the availability of several similar medical devices performing the same function, choosing one for reimbursement is not easy, especially if purchased for a large number of patients. The objective of this project was to create a multicriteria decision analysis (MCDA) tool, that captures and compares all implantable medical devices' attributes, to provide an objective method for choosing among the available options in Egypt.
METHOD
We conducted a systematic review and expert interviews, to identify the relevant criteria for inclusion in the tool. Subsequently, a workshop was conducted, that involved experts in procuring and tendering medical devices. Experts chose the criteria, ranked them, assigned weights and scoring functions for each criterion, and then created the draft tool. A pilot phase followed; then, another workshop was conducted to fine-tune the tool. We readjusted the tool based on experts' experience with the draft tool.
RESULTS
The final tool included eight criteria, arranged according to their weightage: technical characteristics (29.4%), country of origin (19.5%), use in reference countries (14.9%), supply reliability (11.7%), previous use in tenders (9.0%), instant replacement within product variety (6.9%), pharmacovigilance (4.6%), and refund or replacement (4.0%). Each medical device was assessed on these eight criteria to achieve a final score, that was compared to the alternative devices' scores. Price is not included in the MCDA tool, but it will be added in the financial evaluation phase.
CONCLUSION
Decisionmakers could use the MCDA tool, to make evidence-based and objective decisions for purchasing implantable devices, in the Egyptian public sector. Post price evaluation, the product with the best value will be chosen for reimbursement.
HIGHLIGHTS
We created an MCDA tool to help decision makers choose between alternative implantable medical devices in Egypt. The MCDA tool includes eight criteria, where price is evaluated as a separate step. "Technical characteristics" and "country of origin" criteria carried the highest weights, thus representing approximately 50% of the decision.
Topics: Humans; Decision Support Techniques; Egypt; Reproducibility of Results; Public Sector; Prostheses and Implants
PubMed: 36352382
DOI: 10.1186/s12911-022-02025-y -
The Cochrane Database of Systematic... Apr 2013The delivery of combination contraceptive steroids from a transdermal contraceptive patch or a contraceptive vaginal ring offers potential advantages over the... (Meta-Analysis)
Meta-Analysis Review
BACKGROUND
The delivery of combination contraceptive steroids from a transdermal contraceptive patch or a contraceptive vaginal ring offers potential advantages over the traditional oral route. The transdermal patch and vaginal ring could require a lower dose due to increased bioavailability and improved user compliance.
OBJECTIVES
To compare the contraceptive effectiveness, cycle control, compliance (adherence), and safety of the contraceptive patch or the vaginal ring versus combination oral contraceptives (COCs).
SEARCH METHODS
Through February 2013, we searched MEDLINE, POPLINE, CENTRAL, LILACS, ClinicalTrials.gov, and ICTRP for trials of the contraceptive patch or the vaginal ring. Earlier searches also included EMBASE. For the initial review, we contacted known researchers and manufacturers to identify other trials.
SELECTION CRITERIA
We considered randomized controlled trials comparing a transdermal contraceptive patch or a contraceptive vaginal ring with a COC.
DATA COLLECTION AND ANALYSIS
Data were abstracted by two authors and entered into RevMan. For dichotomous variables, the Peto odds ratio (OR) with 95% confidence intervals (CI) was calculated. For continuous variables, the mean difference was computed. We also assessed the quality of evidence for this review.
MAIN RESULTS
We found 18 trials that met our inclusion criteria. Of six patch studies, five examined the marketed patch containing norelgestromin plus ethinyl estradiol (EE); one studied a patch in development that contains levonorgestrel (LNG) plus EE. Of 12 vaginal ring trials, 11 examined the same marketing ring containing etonogestrel plus EE; one studied a ring being developed that contains nesterone plus EE.Contraceptive effectiveness was not significantly different for the patch or ring versus the comparison COC. Compliance data were limited. Patch users showed better compliance than COC users in three trials. For the norelgestromin plus EE patch, ORs were 2.05 (95% CI 1.83 to 2.29) and 2.76 (95% CI 2.35 to 3.24). In the levonorgestrel plus EE patch report, patch users were less likely to have missed days of therapy (OR 0.36; 95% CI 0.25 to 0.51). Of four vaginal ring trials, one found ring users had more noncompliance (OR 3.99; 95% CI 1.87 to 8.52), while another showed more compliance with the regimen (OR 1.67; 95% CI 1.04 to 2.68).More patch users discontinued early than COC users. ORs from two meta-analyses were 1.59 (95% CI 1.26 to 2.00) and 1.56 (95% CI 1.18 to 2.06) and another trial showed OR 2.57 (95% CI 0.99 to 6.64). Patch users also had more discontinuation due to adverse events than COC users. Users of the norelgestromin-containing patch reported more breast discomfort, dysmenorrhea, nausea, and vomiting. In the levonorgestrel-containing patch trial, patch users reported less vomiting, headaches, and fatigue.Of 11 ring trials with discontinuation data, two showed the ring group discontinued less than the COC group: OR 0.32 (95% CI 0.16 to 0.66) and OR 0.52 (95% CI 0.31 to 0.88). Ring users were less likely to discontinue due to adverse events in one study (OR 0.32; 95% CI 0.15 to 0.70). Compared to the COC users, ring users had more vaginitis and leukorrhea but less vaginal dryness. Ring users also reported less nausea, acne, irritability, depression, and emotional lability than COC users.For cycle control, only one trial study showed a significant difference. Women in the patch group were less likely to have breakthrough bleeding and spotting. Seven ring studies had bleeding data; four trials showed the ring group generally had better cycle control than the COC group.
AUTHORS' CONCLUSIONS
Effectiveness was not significantly different for the methods compared. Pregnancy data were available from half of the patch trials but two-thirds of ring trials. The patch could lead to more discontinuation than the COC. The patch group had better compliance than the COC group. Compliance data came from half of the patch studies and one-third of the ring trials. Patch users had more side effects than the COC group. Ring users generally had fewer adverse events than COC users but more vaginal irritation and discharge.The quality of the evidence for this review was considered low for the patch and moderate for the ring. The main reasons for downgrading were lack of information on the randomization sequence generation or allocation concealment, the outcome assessment methods, high losses to follow up, and exclusions after randomization.
Topics: Consumer Behavior; Contraceptive Agents, Female; Contraceptive Devices, Female; Contraceptives, Oral, Combined; Drug Implants; Female; Humans; Medication Adherence; Menstrual Cycle; Pregnancy; Randomized Controlled Trials as Topic
PubMed: 23633314
DOI: 10.1002/14651858.CD003552.pub4 -
European Heart Journal Oct 2015The evaluation for European Union market approval of coronary stents falls under the Medical Device Directive that was adopted in 1993. Specific requirements for the... (Review)
Review
Report of a European Society of Cardiology-European Association of Percutaneous Cardiovascular Interventions task force on the evaluation of coronary stents in Europe: executive summary.
The evaluation for European Union market approval of coronary stents falls under the Medical Device Directive that was adopted in 1993. Specific requirements for the assessment of coronary stents are laid out in supplementary advisory documents. In response to a call by the European Commission to make recommendations for a revision of the advisory document on the evaluation of coronary stents (Appendix 1 of MEDDEV 2.7.1), the European Society of Cardiology (ESC) and the European Association of Percutaneous Cardiovascular Interventions (EAPCI) established a Task Force to develop an expert advisory report. As basis for its report, the ESC-EAPCI Task Force reviewed existing processes, established a comprehensive list of all coronary drug-eluting stents that have received a CE mark to date, and undertook a systematic review of the literature of all published randomized clinical trials evaluating clinical and angiographic outcomes of coronary artery stents between 2002 and 2013. Based on these data, the TF provided recommendations to inform a new regulatory process for coronary stents. The main recommendations of the task force include implementation of a standardized non-clinical assessment of stents and a novel clinical evaluation pathway for market approval. The two-stage clinical evaluation plan includes recommendation for an initial pre-market trial with objective performance criteria (OPC) benchmarking using invasive imaging follow-up leading to conditional CE-mark approval and a subsequent mandatory, large-scale randomized trial with clinical endpoint evaluation leading to unconditional CE-mark. The data analysis from the systematic review of the Task Force may provide a basis for determination of OPC for use in future studies. This paper represents an executive summary of the Task Force's report.
Topics: Absorbable Implants; Cardiac Imaging Techniques; Cardiology; Checklist; Consumer Product Safety; Coronary Artery Disease; Drug-Eluting Stents; Equipment Design; Europe; Humans; Percutaneous Coronary Intervention; Societies, Medical; United States
PubMed: 26071600
DOI: 10.1093/eurheartj/ehv203 -
International Journal of Implant... Jul 2018The literature states that Strontium (Sr) is able to simultaneously stimulate bone formation and suppress bone resorption. Recent animal studies suggest that the... (Review)
Review
The literature states that Strontium (Sr) is able to simultaneously stimulate bone formation and suppress bone resorption. Recent animal studies suggest that the systemic administration of Sr, in the form of strontium ranelate (SRAN), would enhance the osseointegration of implants. The purpose of the present study was to undertake a systematic review on animal studies evaluating the systemic administration of Sr to enhance the osseointegration of titanium implants and the remodeling of bone grafts. The MEDLINE (PubMed) and Scopus bibliographic databases were searched from 1950 to October 2017 for reports on the use of systemic and non-radioactive Sr to enhance the osseointegration of titanium implants and the remodeling of bone grafts in animals. The search strategy was restricted to English language publications using the combined terms: "strontium" and "implant or graft or biomaterial or bone substitute". Five studies were included, all related to the systemic administration of Sr in the form SRAN, and its effects on osseointegration of titanium implants. No studies on the use of SRAN-based therapy to enhance the remodeling of bone grafts were found. The studies differed notably with respect to the study population (healthy female rats, healthy male rats, and female rats with induced osteoporosis) and SRAN dose (ranging from 500 to 1000 mg/kg/day). Results were diverse, but a tendency suggesting positive influence of systemic SRAN administration on the osseointegration of titanium implants was observed. No major side-effects due to strontium administration were reported. Systemic Sr administration, in the form of SRAN, seems to enhance peri-implant bone quality and implant osseointegration in animals, however, at a moderate extent. Further studies, evaluating both the effects of this drug on implant osseointegration and the risk/benefit of its use, are needed to provide a rationale of this therapeutic approach.
PubMed: 30014305
DOI: 10.1186/s40729-018-0132-8 -
The Cochrane Database of Systematic... Mar 2017Premenstrual syndrome (PMS) is a psychological and somatic disorder of unknown aetiology, with symptoms typically including irritability, depression, mood swings,... (Meta-Analysis)
Meta-Analysis Review
BACKGROUND
Premenstrual syndrome (PMS) is a psychological and somatic disorder of unknown aetiology, with symptoms typically including irritability, depression, mood swings, bloating, breast tenderness and sleep disturbances. About 3% to 10% of women who experience these symptoms may also meet criteria for premenstrual dysphoric disorder (PMDD). PMS symptoms recur during the luteal phase of the menstrual cycle and reduce by the end of menstruation. PMS results from ovulation and may be due to ovarian steroid interactions relating to neurotransmitter dysfunction. Premenstrual disorders have a devastating effect on women, their families and their work.Several treatment options have been suggested for PMS, including pharmacological and surgical interventions. The treatments thought to be most effective tend to fall into one of two categories: suppressing ovulation or correcting a speculated neuroendocrine anomaly.Transdermal oestradiol by patch, gel or implant effectively stops ovulation and the cyclical hormonal changes which produce the cyclical symptoms. These preparations are normally used for hormone therapy and contain lower doses of oestrogen than found in oral contraceptive pills. A shortened seven-day course of a progestogen is required each month for endometrial protection but can reproduce premenstrual syndrome-type symptoms in these women.
OBJECTIVES
To determine the effectiveness and safety of non-contraceptive oestrogen-containing preparations in the management of PMS.
SEARCH METHODS
On 14 March 2016, we searched the following databases: the Cochrane Gynaecology and Fertility Group (CGF) Specialised Register; Cochrane Central Register of Studies (CRSO); MEDLINE; Embase; PsycINFO; CINAHL; ClinicalTrials.gov; metaRegister of Controlled trials (mRCT); and the World Health Organization (WHO) International Clinical Trials Registry Platform (ICTRP) Search Portal. In addition, we checked the reference lists of articles retrieved.
SELECTION CRITERIA
We included published and unpublished randomized placebo or active controlled trials on the efficacy of the use of non-contraceptive oestrogen-containing preparations in the management of premenstrual syndrome in women of reproductive age with PMS diagnosed by at least two prospective cycles without current psychiatric disorder.
DATA COLLECTION AND ANALYSIS
Two review authors independently selected studies, assessed risk of bias, extracted data on premenstrual symptoms and adverse effects and entered data into Review Manager 5 software. Where possible, intention-to-treat or modified intention-to-treat analysis was used. Studies were pooled using a fixed-effect model, analysing cross-over trials as parallel trials. Standardised mean differences (SMDs) with 95% confidence intervals (CIs) were calculated for premenstrual symptom scores. Risk ratios (RRs) with 95% confidence intervals (CIs) were calculated for dichotomous outcomes. The overall quality of the evidence was assessed using the GRADE working group methods.
MAIN RESULTS
The search resulted in 524 potentially relevant articles. Five eligible randomized controlled trials (RCTs) were identified (305 women). Trials using oral tablets, transdermal patches and implants were identified. No trial used gels.One small cross-over trial (11 women, effective sample size 22 women considering cross-over trials) compared oral luteal-phase oestrogen versus placebo. Data were very low quality and unsuitable for analysis, but study authors reported that the intervention was ineffective and might aggravate the symptoms of PMS. They also reported that there were no adverse events.Three studies compared continuous oestrogen with progestogen versus placebo (with or without progestogen). These trials were of reasonable quality, although with a high risk of attrition bias and an unclear risk of bias due to potential carry-over effects in two cross-over trials. Continuous oestrogen had a small to moderate positive effect on global symptom scores (SMD -0.34, 95% CI -0.59 to -0.10, P = 0.005, 3 RCTs, 158 women, effective sample size 267 women, I² = 63%, very low quality evidence). The evidence was too imprecise to determine if the groups differed in withdrawal rates due to adverse effects (RR 0.64, 95% CI 0.26 to 1.58, P = 0.33, 3 RCTs, 196 women, effective sample size 284 women, I² = 0%, very low quality evidence). Similarly, the evidence was very imprecise in measures of specific adverse events, with large uncertainties around the true value of the relative risk. None of the studies reported on long-term risks such as endometrial cancer or breast cancer.One study compared patch dosage (100 vs 200 µg oestrogen, with progestogen in both arms) and had a high risk of performance bias, detection bias and attrition bias. The study did not find evidence that dosage affects global symptoms but there was much uncertainty around the effect estimate (SMD -1.55, 95% CI -8.88 to 5.78, P = 0.68, 1 RCT, 98 women, very low quality evidence). The evidence on rates of withdrawal for adverse events was too imprecise to draw any conclusions (RR 0.70, 95% CI 0.34 to 1.46, P = 0.34, 1 RCT, 107 women, low-quality evidence). However, it appeared that the 100 µg dose might be associated with a lower overall risk of adverse events attributed to oestrogen (RR 0.51, 95% Cl 0.26 to 0.99, P = 0.05, 1 RCT, 107 women, very low quality evidence) with a large uncertainty around the effect estimate.The overall quality of the evidence for all comparisons was very low, mainly due to risk of bias (specifically attrition), imprecision, and statistical and clinical heterogeneity.
AUTHORS' CONCLUSIONS
We found very low quality evidence to support the effectiveness of continuous oestrogen (transdermal patches or subcutaneous implants) plus progestogen, with a small to moderate effect size. We found very low quality evidence from a study based on 11 women to suggest that luteal-phase oral unopposed oestrogen is probably ineffective and possibly detrimental for controlling the symptoms of PMS. A comparison between 200 µg and 100 µg doses of continuous oestrogen was inconclusive with regard to effectiveness, but suggested that the lower dose was less likely to cause side effects. Uncertainty remains regarding safety, as the identified studies were too small to provide definite answers. Moreover, no included trial addressed adverse effects that might occur beyond the typical trial duration of 2-8 months. This suggests the choice of oestrogen dose and mode of administration could be based on an individual woman's preference and modified according to the effectiveness and tolerability of the chosen regimen.
Topics: Administration, Oral; Drug Implants; Drug Therapy, Combination; Estrogens; Female; Humans; Luteal Phase; Premenstrual Dysphoric Disorder; Premenstrual Syndrome; Progestins; Randomized Controlled Trials as Topic; Transdermal Patch
PubMed: 28257559
DOI: 10.1002/14651858.CD010503.pub2 -
The Cochrane Database of Systematic... Sep 2015Central retinal vein occlusion (CRVO) is a common retinal vascular abnormality associated with conditions such as hypertension, diabetes, glaucoma, and a wide variety of... (Meta-Analysis)
Meta-Analysis Review
BACKGROUND
Central retinal vein occlusion (CRVO) is a common retinal vascular abnormality associated with conditions such as hypertension, diabetes, glaucoma, and a wide variety of hematologic disorders. Macular edema (ME) represents an important vision-threatening complication of CRVO. Intravitreal steroids (IVS), such as triamcinolone acetonide, have been utilized to treat macular edema stemming from a variety of etiologies and may be a treatment option for CRVO-ME.
OBJECTIVES
To explore the effectiveness and safety of intravitreal steroids in the treatment of CRVO-ME.
SEARCH METHODS
We searched CENTRAL (which contains the Cochrane Eyes and Vision Group Trials Register) (2014 Issue 10), Ovid MEDLINE, Ovid MEDLINE In-Process and Other Non-Indexed Citations, Ovid MEDLINE Daily, Ovid OLDMEDLINE (January 1946 to November 2014), EMBASE (January 1980 to November 2014), the metaRegister of Controlled Trials (mRCT) (www.controlled-trials.com), ClinicalTrials.gov (www.clinicaltrials.gov) and the World Health Organization (WHO) International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en). We did not use any date or language restrictions in the electronic searches for trials. We last searched the electronic databases on 13 November 2014. For all included primary studies, we used The Science Citation Index (3 December 2014) and manually reviewed reference lists to identify other possible relevant trials.
SELECTION CRITERIA
We included randomized controlled trials (RCTs) that compared intravitreal steroids, of any dosage and duration of treatment of at least six months, with observation for the treatment of CRVO-ME.
DATA COLLECTION AND ANALYSIS
Two review authors independently screened titles and abstracts identified from the electronic searches and assessed full-text articles from potentially eligible trials. Two review authors independently assessed trial characteristics, risk of bias, and extracted data from included trials. We contacted investigators of included trials for desired data not provided in the trial reports.
MAIN RESULTS
We included two RCTs that enrolled a total of 708 participants with CRVO-ME. SCORE compared triamcinolone acetonide intravitreal injections (n = 165) with observation (n = 72); GENEVA compared dexamethasone intravitreal implants (n = 290) with sham injections (n = 147). We observed characteristics indicative of high risk of bias due to incomplete outcome data in SCORE and selective outcome reporting in GENEVA. Loss to follow-up was high with 10% in the steroid groups and almost twice as much (17%) in the observation group. GENEVA enrolled participants with both branch and central retinal vein occlusion, but did not present subgroup data for the CRVO-ME population. A qualitative assessment of the results from GENEVA indicated that the dexamethasone implant was not associated with improvement in visual acuity after six months among participants with CRVO-ME. Although the SCORE investigators reported that participants treated with 1 mg (n = 82) or 4 mg (n = 83) triamcinolone intravitreal injections were five times more likely to have gained 15 letters or more in visual acuity compared with participants in the observation group (1 mg; risk ratio (RR): 5.27; 95% confidence interval (CI) 1.62 to 17.15; 4 mg RR 4.92; 95% CI 1.50 to 16.10) by the eighth-month follow-up examination, the average visual acuity decreased in all three groups. However, eyes treated with triamcinolone lost fewer letters than participants in the observation group at 8 months (1 mg mean difference (MD): 8.70 letters, 95% CI 1.86 to 15.54; 4 mg MD: 9.80 letters, 95% CI 3.32 to 16.28). A higher incidence of adverse events was noted with IVS therapy when compared with observation alone. As many as 20% to 35% of participants experienced an adverse event in the IVS groups compared with 8% of participants in the observation group of the SCORE study. The GENEVA investigators reported 63% in the treatment arm versus 43% in the observation arm experienced an adverse event. The most commonly encountered adverse events were elevated intraocular pressure, progression of cataracts, and retinal neovascularization. We graded the quality of evidence as low due to study limitations, imprecision of treatment estimates, and selective outcome reporting.
AUTHORS' CONCLUSIONS
The two RCTs reviewed herein provide insufficient evidence to determine the benefits of IVS for individuals with CRVO-ME. The improvement in visual acuity noted in the SCORE trial should be interpreted with caution as outcome data were missing for a large proportion of the observation group. Adverse events were observed more often with IVS treatment compared with observation/no treatment.
Topics: Dexamethasone; Humans; Intravitreal Injections; Macular Edema; Randomized Controlled Trials as Topic; Retinal Vein Occlusion; Steroids; Triamcinolone; Visual Acuity; Watchful Waiting
PubMed: 26352007
DOI: 10.1002/14651858.CD007324.pub3 -
The Cochrane Database of Systematic... Nov 2020Diabetic macular edema (DME) is secondary to leakage from diseased retinal capillaries with thickening of central retina, and is an important cause of poor central... (Meta-Analysis)
Meta-Analysis
BACKGROUND
Diabetic macular edema (DME) is secondary to leakage from diseased retinal capillaries with thickening of central retina, and is an important cause of poor central visual acuity in people with diabetic retinopathy. Intravitreal steroids have been used to reduce retinal thickness and improve vision in people with DME.
OBJECTIVES
To assess the effectiveness and safety of intravitreal steroid therapy compared with other treatments for DME.
SEARCH METHODS
We searched the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, and Embase on 15 May, 2019. We also searched reference lists, Science Citation Index, conference proceedings, and relevant trial registers. We conducted a top up search on 21 October, 2020.
SELECTION CRITERIA
We included randomized controlled trials that evaluated any type of intravitreal steroids as monotherapy against any other intervention (e.g. observation, laser photocoagulation, anti-vascular endothelial growth factor (antiVEGF) for DME.
DATA COLLECTION AND ANALYSIS
Two review authors independently assessed study eligibility and risk of bias and extracted data. Where appropriate, we performed meta-analyses.
MAIN RESULTS
We included 10 trials (4348 participants, 4505 eyes). These trials compared intravitreal steroid therapies versus other treatments, including intravitreal antiVEGF therapy, laser photocoagulation, and sham injection. Most trials had an overall unclear or high risk of bias. One trial (701 eyes ) compared intravitreal dexamethasone implant 0.7mg with sham. We found moderate-certainty evidence that dexamethasone leads to slightly more improvement of visual acuity than sham at 12 months (mean difference [MD] -0.08 logMAR, 95% confidence interval [CI] -0.12 to -0.05 logMAR). Regarding improvement of three or more lines of visual acuity, there was moderate-certainty evidence in favor of dexamethasone at 12 months, but the CI covered the null value (risk ratio (RR) 1.39, 95% CI 0.91 to 2.12). Regarding adverse events, dexamethasone increased by about four times the risk of cataract progression and the risk of using intraocular pressure (IOP)-lowering medications compared to sham (RR 3.89, 95% CI 2.75 to 5.50 and RR 4.54, 95% CI 3.19 to 6.46, respectively; moderate-certainty evidence); about 4 in 10 participants treated with dexamethasone needed IOP-lowering medications. Two trials (451 eyes) compared intravitreal dexamethasone implant 0.7mg with intravitreal antiVEGF (bevacizumab and ranibizumab). There was moderate-certainty evidence that visual acuity improved slightly less with dexamethasone compared with antiVEGF at 12 months (MD 0.07 logMAR, 95% CI 0.04 to 0.09 logMAR; 2 trials; 451 participants/eyes; I = 0%). The RR of gain of three or more lines of visual acuity was inconsistent between trials, with one trial finding no evidence of a difference between dexamethasone and bevacizumab at 12 months (RR 0.99, 95% CI 0.70 to 1.40; 1 trial; 88 eyes), and the other, larger trial finding the chances of vision gain were half with dexamethasone compared with ranibizumab (RR 0.50, 95% CI 0.32 to 0.79; 1 trial; 432 participants). The certainty of evidence was low. Cataract progression and the need for IOP-lowering medications increased more than 4 times with dexamethasone implant compared to antiVEGF (moderate-certainty evidence). One trial (560 eyes) compared intravitreal fluocinolone implant 0.19mg with sham. There was moderate-certainty evidence that visual acuity improved slightly more with fluocinolone at 12 months (MD -0.04 logMAR, 95% CI -0.06 to -0.01 logMAR). There was moderate-certainty evidence that an improvement in visual acuity of three or more lines was more common with fluocinolone than with sham at 12 months (RR 1.79, 95% CI 1.16 to 2.78). Fluocinolone also increased the risk of cataract progression (RR 1.63, 95% CI 1.35 to 1.97; participants = 335; moderate-certainty evidence), which occurred in about 8 in 10 participants, and the use of IOP-lowering medications (RR 2.72, 95% CI 1.87 to 3.98; participants = 558; moderate-certainty evidence), which were needed in 2 to 3 out of 10 participants. One small trial with 43 participants (69 eyes) compared intravitreal triamcinolone acetonide injection 4 mg with sham. There may be a benefit in visual acuity at 24 months (MD -0.11 logMAR, 95% CI -0.20 to -0.03 logMAR), but the certainty of evidence is low. Differences in adverse effects were poorly reported in this trial. Two trials (615 eyes) compared intravitreal triamcinolone acetonide injection 4mg with laser photocoagulation and reached discordant results. The smaller trial (31 eyes followed up to 9 months) found more visual acuity improvement with triamcinolone (MD -0.18 logMAR, 95% CI -0.29 to -0.07 logMAR), but a larger, multicenter trial (584 eyes, 12-month follow-up) found no evidence of a difference regarding change in visual acuity (MD 0.02 logMAR, 95% CI -0.03 to 0.07 logMAR) or gain of three or more lines of visual acuity (RR 0.85, 95% CI 0.55 to 1.30) (overall low-certainty evidence). Cataract progression was about three times more likely (RR 2.68, 95% CI 2.21 to 3.24; moderate-certainty evidence) and the use of IOP-lowering medications was about four times more likely (RR 3.92, 95% CI 2.59 to 5.96; participants = 627; studies = 2; I = 0%; moderate-certainty evidence) with triamcinolone. About 1 in 3 participants needed IOP-lowering medication. One small trial (30 eyes) compared intravitreal triamcinolone acetonide injection 4mg with intravitreal antiVEGF (bevacizumab or ranibizumab). Visual acuity may be worse with triamcinolone at 12 months (MD 0.18 logMAR, 95% CI 0.10 to 0.26 logMAR); the certainty of evidence is low. Adverse effects were poorly reported in this trial. Four trials reported data on pseudophakic participants, for whom cataract is not a concern. These trials found no decrease in visual acuity in the second treatment year due to cataract progression.
AUTHORS' CONCLUSIONS
Intravitreal steroids may improve vision in people with DME compared to sham or control. Effects were small, about one line of vision or less in most comparisons. More evidence is available for dexamethasone or fluocinolone implants when compared to sham, and the evidence is limited and inconsistent for the comparison of dexamethasone with antiVEGF treatment. Any benefits should be weighed against IOP elevation, the use of IOP-lowering medication and, in phakic patients, the progression of cataract. The need for glaucoma surgery is also increased, but remains rare.
Topics: Anti-Inflammatory Agents; Bevacizumab; Bias; Confidence Intervals; Dexamethasone; Diabetic Retinopathy; Drug Implants; Fluocinolone Acetonide; Glucocorticoids; Humans; Intravitreal Injections; Macular Edema; Randomized Controlled Trials as Topic; Ranibizumab; Steroids; Triamcinolone; Vascular Endothelial Growth Factor A; Visual Acuity; Vitreous Body
PubMed: 33206392
DOI: 10.1002/14651858.CD005656.pub3 -
Journal of Taibah University Medical... Oct 2017Bisphosphonates (BPs) are a class of drugs that are used to treat osteoporosis. It has been suggested that BP coatings on dental implants have a positive effect on new... (Review)
Review
OBJECTIVES
Bisphosphonates (BPs) are a class of drugs that are used to treat osteoporosis. It has been suggested that BP coatings on dental implants have a positive effect on new bone formation. The purpose of this review is to analyse the currently available data concerning the clinical and experimental efficacy of BP-releasing titanium implants such that their potential in clinical oral implant dentistry may be ascertained.
METHODS
Based on a literature review, a focused research question was constructed: what is the effect of a BP-releasing coating on the osseointegration of titanium dental implant? The databases of PubMED/MEDLINE; ISI Web of Knowledge; Embase and Google Scholar were searched electronically using the keywords 'dental implant'; 'bisphosphonate' and 'titanium.' The quality; general characteristics and outcomes of each study were summarized and analysed systematically.
RESULTS
A total of eleven articles fulfilled the criteria to be included in this review. Eight studies were experimental; two studies were clinical; and one study was experimental and clinical. In nine studies (82%), BP-coated implants resulted in higher osseointegration, as indicated by higher resonance frequency values, removal torque, bone-implant contact and new bone formation. In two studies (18%), there was no difference between the osseointegration of BP-coated implants and controls.
CONCLUSIONS
Bisphosphonates-loaded implants may have a positive effect on osseointegration. However, more well-designed clinical studies are required to demonstrate their osseoconductive effects.
PubMed: 31435266
DOI: 10.1016/j.jtumed.2017.05.007 -
The Cochrane Database of Systematic... Feb 2017Despite multi-modal analgesic techniques, acute postoperative pain remains an unmet health need, with up to three quarters of people undergoing surgery reporting... (Review)
Review
BACKGROUND
Despite multi-modal analgesic techniques, acute postoperative pain remains an unmet health need, with up to three quarters of people undergoing surgery reporting significant pain. Liposomal bupivacaine is an analgesic consisting of bupivacaine hydrochloride encapsulated within multiple, non-concentric lipid bi-layers offering a novel method of sustained-release analgesia.
OBJECTIVES
To assess the analgesic efficacy and adverse effects of liposomal bupivacaine infiltration at the surgical site for the management of postoperative pain.
SEARCH METHODS
On 13 January 2016 we searched CENTRAL, MEDLINE, MEDLINE In-Process, Embase, ISI Web of Science and reference lists of retrieved articles. We obtained clinical trial reports and synopses of published and unpublished studies from Internet sources, and searched clinical trials databases for ongoing trials.
SELECTION CRITERIA
Randomised, double-blind, placebo- or active-controlled clinical trials in people aged 18 years or over undergoing elective surgery, at any surgical site, were included if they compared liposomal bupivacaine infiltration at the surgical site with placebo or other type of analgesia.
DATA COLLECTION AND ANALYSIS
Two review authors independently considered trials for inclusion, assessed risk of bias, and extracted data. We performed data analysis using standard statistical techniques as described in the Cochrane Handbook for Systematic Reviews of Interventions, using Review Manager 5.3. We planned to perform a meta-analysis and produce a 'Summary of findings' table for each comparison however there were insufficient data to ensure a clinically meaningful answer. As such we have produced two 'Summary of findings' tables in a narrative format. Where possible we assessed the quality of evidence using GRADE.
MAIN RESULTS
We identified nine studies (10 reports, 1377 participants) that met inclusion criteria. Four Phase II dose-escalating/de-escalating trials, designed to evaluate and demonstrate efficacy and safety, presented pooled data that we could not use. Of the remaining five parallel-arm studies (965 participants), two were placebo controlled and three used bupivacaine hydrochloride local anaesthetic infiltration as a control. Using the Cochrane tool, we judged most studies to be at unclear risk of bias overall; however, two studies were at high risk of selective reporting bias and four studies were at high risk of bias due to size (fewer than 50 participants per treatment arm).Three studies (551 participants) reported the primary outcome cumulative pain intensity over 72 hours following surgery. Compared to placebo, liposomal bupivacaine was associated with a lower cumulative pain score between the end of the operation (0 hours) and 72 hours (one study, very low quality). Compared to bupivacaine hydrochloride, two studies showed no difference for this outcome (very low quality evidence), however due to differences in the surgical population and surgical procedure (breast augmentation versus knee arthroplasty) we did not perform a meta-analysis.No serious adverse events were reported to be associated with the use of liposomal bupivacaine and none of the five studies reported withdrawals due to drug-related adverse events (moderate quality evidence).One study reported a lower mean pain score at 12 hours associated with liposomal bupivacaine compared to bupivacaine hydrochloride, but not at 24, 48 or 72 hours postoperatively (very low quality evidence).Two studies (382 participants) reported a longer time to first postoperative opioid dose compared to placebo (low quality evidence).Two studies (325 participants) reported the total postoperative opioid consumption over the first 72 hours: one study reported a lower cumulative opioid consumption for liposomal bupivacaine compared to placebo (very low quality evidence); one study reported no difference compared to bupivacaine hydrochloride (very low quality evidence).Three studies (492 participants) reported the percentage of participants not requiring postoperative opioids over initial 72 hours following surgery. One of the two studies comparing liposomal bupivacaine to placebo demonstrated a higher number of participants receiving liposomal bupivacaine did not require postoperative opioids (very low quality evidence). The other two studies, one versus placebo and one versus bupivacaine hydrochloride, found no difference in opioid requirement (very low quality evidence). Due to significant heterogeneity between the studies (I = 92%) we did not pool the results.All the included studies reported adverse events within 30 days of surgery, with nausea, constipation and vomiting being the most common. Of the five parallel-arm studies, none performed or reported health economic assessments or patient-reported outcomes other than pain.Using GRADE, the quality of evidence ranged from moderate to very low. The major limitation was the sparseness of data for outcomes of interest. In addition, a number of studies had a high risk of bias resulting in further downgrading.
AUTHORS' CONCLUSIONS
Liposomal bupivacaine at the surgical site does appear to reduce postoperative pain compared to placebo, however, at present the limited evidence does not demonstrate superiority to bupivacaine hydrochloride. There were no reported drug-related serious adverse events and no study withdrawals due to drug-related adverse events. Overall due to the low quality and volume of evidence our confidence in the effect estimate is limited and the true effect may be substantially different from our estimate.
Topics: Anesthetics, Local; Arthroplasty, Replacement, Knee; Bupivacaine; Humans; Liposomes; Mammaplasty; Pain Measurement; Pain, Postoperative; Randomized Controlled Trials as Topic
PubMed: 28146271
DOI: 10.1002/14651858.CD011419.pub2 -
Cancers Apr 2022This systematic review investigated circulating methylated tumor DNA in bronchial lavage fluid for diagnosing lung cancer. PROSPERO registration CRD42022309470. PubMed,... (Review)
Review
This systematic review investigated circulating methylated tumor DNA in bronchial lavage fluid for diagnosing lung cancer. PROSPERO registration CRD42022309470. PubMed, Embase, Medline, and Web of Science were searched on 9 March 2022. Studies of adults with lung cancer or undergoing diagnostic workup for suspected lung cancer were included if they used bronchial lavage fluid, analyzed methylated circulating tumor DNA, and reported the diagnostic properties. Sensitivity, specificity, and lung cancer prevalence were summarized in forest plots. Risk of bias was assessed using the QUADAS-2 tool. A total of 25 studies were included. All were case-control studies, most studies used cell pellet for analysis by quantitative PCR. Diagnostic sensitivity ranged from 0% for a single gene to 97% for a four-gene panel. Specificity ranged from 8% for a single gene to 100%. The studies employing a gene panel decreased the specificity, and no gene panel had a perfect specificity of 100%. In conclusion, methylated circulating tumor DNA can be detected in bronchial lavage, and by employing a gene panel the sensitivity can be increased to clinically relevant levels. The available evidence regarding applicability in routine clinical practice is limited. Prospective, randomized clinical trials are needed to determine the further usefulness of this biomarker.
PubMed: 35565384
DOI: 10.3390/cancers14092254