-
European Journal of Preventive... Aug 2016Pulse palpation has been recommended as the first step of screening to detect atrial fibrillation. We aimed to determine and compare the accuracy of different methods... (Meta-Analysis)
Meta-Analysis Review
BACKGROUND
Pulse palpation has been recommended as the first step of screening to detect atrial fibrillation. We aimed to determine and compare the accuracy of different methods for detecting pulse irregularities caused by atrial fibrillation.
METHODS
We systematically searched MEDLINE, EMBASE, CINAHL and LILACS until 16 March 2015. Two reviewers identified eligible studies, extracted data and appraised quality using the QUADAS-2 instrument. Meta-analysis, using the bivariate hierarchical random effects method, determined average operating points for sensitivities, specificities, positive and negative likelihood ratios (PLR, NLR); we constructed summary receiver operating characteristic plots.
RESULTS
Twenty-one studies investigated 39 interventions (n = 15,129 pulse assessments) for detecting atrial fibrillation. Compared to 12-lead electrocardiography (ECG) diagnosed atrial fibrillation, blood pressure monitors (BPMs; seven interventions) and non-12-lead ECGs (20 interventions) had the greatest accuracy for detecting pulse irregularities attributable to atrial fibrillation (BPM: sensitivity 0.98 (95% confidence interval (CI) 0.92-1.00), specificity 0.92 (95% CI 0.88-0.95), PLR 12.1 (95% CI 8.2-17.8) and NLR 0.02 (95% CI 0.00-0.09); non-12-lead ECG: sensitivity 0.91 (95% CI 0.86-0.94), specificity 0.95 (95% CI 0.92-0.97), PLR 20.1 (95% CI 12-33.7), NLR 0.09 (95% CI 0.06-0.14)). There were similar findings for smartphone applications (six interventions) although these studies were small in size. The sensitivity and specificity of pulse palpation (six interventions) were 0.92 (95% CI 0.85-0.96) and 0.82 (95% CI 0.76-0.88), respectively (PLR 5.2 (95% CI 3.8-7.2), NLR 0.1 (95% CI 0.05-0.18)).
CONCLUSIONS
BPMs and non-12-lead ECG were most accurate for detecting pulse irregularities caused by atrial fibrillation; other technologies may therefore be pragmatic alternatives to pulse palpation for the first step of atrial fibrillation screening.
Topics: Atrial Fibrillation; Electrocardiography; Heart Rate; Humans; Palpation; ROC Curve
PubMed: 26464292
DOI: 10.1177/2047487315611347 -
The Cochrane Database of Systematic... Mar 2020Meibomian gland dysfunction (MGD) is the major cause of evaporative dry eye disease, which is the more prevalent form of dry eye disease. Intense pulsed light (IPL)... (Meta-Analysis)
Meta-Analysis
BACKGROUND
Meibomian gland dysfunction (MGD) is the major cause of evaporative dry eye disease, which is the more prevalent form of dry eye disease. Intense pulsed light (IPL) therapy, involving treatment of the skin near the eyelids, has emerged as a potential treatment for MGD.
OBJECTIVES
To evaluate the effectiveness and safety of intense pulsed light (IPL) for the management dry eye disease resulting from meibomian gland dysfunction (MGD).
SEARCH METHODS
We searched CENTRAL, MEDLINE (Ovid), Embase Ovid and three trial registers for eligible clinical trials on 1 August 2019. There were no restrictions on publication status, date or language.
SELECTION CRITERIA
We included randomised controlled trials (RCTs) studying the effectiveness or safety of IPL for treating MGD.
DATA COLLECTION AND ANALYSIS
Our outcomes of interest were the change from baseline in subjective dry eye symptoms, adverse events, changes to lipid layer thickness, tear break-up time (TBUT), tear osmolarity, eyelid irregularity, eyelid telangiectasia, meibomian gland orifice plugging, meibomian gland dropout, corneal sodium fluorescein staining and conjunctival lissamine green staining. Two review authors independently screened abstracts and full-text articles, extracted data from eligible RCTs and judged the risk of bias using the Cochrane tool. We reached consensus on any disagreements by discussion. We summarised the overall certainty of the evidence using the GRADE Working Group approach.
MAIN RESULTS
We included three RCTs, one from New Zealand, one from Japan and one from China, published between 2015 and 2019. Together, these trials enrolled 114 adults (228 eyes). Two studies used a paired-eye (inter-eye comparison) design to evaluate the effects of a sham (control) IPL treatment relative to an actual IPL treatment. One study randomised individuals to either an IPL intervention combined with meibomian gland expression (MGX), or MGX alone (standard therapy). The study follow-up periods ranged from 45 days to nine months. None of the trials were at low risk of bias in all seven domains. The first authors of two included studies were in receipt of funding from patents or the manufacturers of IPL devices. The funding sources and declaration of interests were not given in the report of the third included trial. All three trials evaluated the effect of IPL on dry eye symptoms, quantified using the Standard Patient Evaluation of Eye Dryness (SPEED) questionnaire. Pooling data from two trials that used a paired-eye design, the summary estimate for these studies indicated little to no reduction in dry eye symptoms with IPL relative to a sham intervention (mean difference (MD) -0.33 units, 95% confidence interval (CI) -2.56 to 1.89; I² = 0%; 2 studies, 144 eyes). The other study was not pooled as it had a unit-of-analysis error, but reported a reduction in symptoms in favour of IPL (MD -4.60, 95% CI -6.72 to -2.48; 84 eyes). The body of evidence for this outcome was of very low certainty, so we are uncertain about the effect of IPL on dry eye symptoms. There were no relevant combinable data for any of the other secondary outcomes, thus the effect of IPL on clinical parameters relevant to dry eye disease are currently unclear. For sodium fluorescein TBUT, two studies indicated that there may be an improvement in favour of IPL (MD 2.02 seconds, 95% CI 0.87 to 3.17; MD 2.40 seconds, 95% CI 2.27 to 2.53; 172 eyes total; low-certainty evidence). We are uncertain of the effect of IPL on non-invasive tear break-up time (MD 5.51 seconds, 95% CI 0.79 to 10.23; MD 3.20, 95% CI 3.09 to 3.31 seconds; two studies; 140 eyes total; very low-certainty evidence). For tear osmolarity, one study indicated that there may be an improvement in favour of IPL (MD -7.00 mOsmol/L, 95% -12.97 to -1.03; 56 eyes; low-certainty evidence). We are uncertain of the effect of IPL on meibomian gland orifice plugging (MD -1.20 clinical units, 95% CI -1.24 to -1.16; 84 eyes; very low-certainty evidence). We are uncertain of the effect of IPL on corneal sodium fluorescein staining. One study reported no evidence of a difference between the IPL and sham intervention arms at three months of follow-up (P = 0.409), and a second study reported data favouring IPL (MD -1.00 units, 95% CI -1.07 to -0.93 units; 172 eyes in total; very low-certainty evidence). We considered the incidence of adverse events at the study endpoint, as a measure of safety. As most trials did not specifically report adverse events, the safety of IPL as a treatment for MGD could also not be determined with any certainty. Very low-certainty results from individual studies suggest some adverse effects that may be experienced by participants, include mild pain and burning, and the potential for partially losing eyelashes (due to clinician error).
AUTHORS' CONCLUSIONS
This systematic review finds a scarcity of RCT evidence relating to the effectiveness and safety of IPL as a treatment for MGD. Whether IPL is of value for modifying the symptoms or signs of evaporative dry eye disease is currently uncertain. Due to a lack of comprehensive reporting of adverse events, the safety profile of IPL in this patient population is also unclear. The current limitations in the evidence base should be considered by clinicians using this intervention to treat MGD, and outlined to individuals potentially undergoing this procedure with the intent of treating dry eye disease. The results of the 14 RCTs currently in progress will be of major importance for establishing a more definitive answer regarding the effectiveness and safety of IPL for treating MGD. We intend to update this review when results from these trials become available.
Topics: Dry Eye Syndromes; Humans; Intense Pulsed Light Therapy; Meibomian Gland Dysfunction; Randomized Controlled Trials as Topic
PubMed: 32182637
DOI: 10.1002/14651858.CD013559 -
The Cochrane Database of Systematic... Jan 2020Infants in the neonatal intensive care unit (NICU) are subjected to stress, including sound of high intensity. The sound environment in the NICU is louder than most home... (Meta-Analysis)
Meta-Analysis
BACKGROUND
Infants in the neonatal intensive care unit (NICU) are subjected to stress, including sound of high intensity. The sound environment in the NICU is louder than most home or office environments and contains disturbing noises of short duration and at irregular intervals. There are competing auditory signals that frequently challenge preterm infants, staff and parents. The sound levels in NICUs often exceed the maximum acceptable level of 45 decibels (dB), recommended by the American Academy of Pediatrics. Hearing impairment is diagnosed in 2% to 10% of preterm infants versus 0.1% of the general paediatric population. Noise may cause apnoea, hypoxaemia, alternation in oxygen saturation, and increased oxygen consumption secondary to elevated heart and respiratory rates and may, therefore, decrease the amount of calories available for growth. Elevated levels of speech are needed to overcome the noisy environment in the NICU, thereby increasing the negative impacts on staff, newborns, and their families. High noise levels are associated with an increased rate of errors and accidents, leading to decreased performance among staff. The aim of interventions included in this review is to reduce sound levels to 45 dB or less. This can be achieved by lowering the sound levels in an entire unit, treating the infant in a section of a NICU, in a 'private' room, or in incubators in which the sound levels are controlled, or reducing the sound levels that reaches the individual infant by using earmuffs or earplugs. By lowering the sound levels that reach the neonate, the resulting stress on the cardiovascular, respiratory, neurological, and endocrine systems can be diminished, thereby promoting growth and reducing adverse neonatal outcomes.
OBJECTIVES
Primary objective To determine the effects of sound reduction on growth and long-term neurodevelopmental outcomes of neonates. Secondary objectives 1. To evaluate the effects of sound reduction on short-term medical outcomes (bronchopulmonary dysplasia, intraventricular haemorrhage, periventricular leukomalacia, retinopathy of prematurity). 2. To evaluate the effects of sound reduction on sleep patterns at three months of age. 3. To evaluate the effects of sound reduction on staff performance. 4. To evaluate the effects of sound reduction in the neonatal intensive care unit (NICU) on parents' satisfaction with the care.
SEARCH METHODS
We searched the Cochrane Central Register of Controlled Trials (The Cochrane Library), MEDLINE, EMBASE, CINAHL, abstracts from scientific meetings, clinical trials registries (clinicaltrials.gov; controlled-trials.com; and who.int/ictrp), Pediatric Academic Societies Annual meetings 2000 to 2014 (Abstracts2View), reference lists of identified trials, and reviews to November 2014.
SELECTION CRITERIA
Preterm infants (< 32 weeks' postmenstrual age (PMA) or < 1500 g birth weight) cared for in the resuscitation area, during transport, or once admitted to a NICU or a stepdown unit.
DATA COLLECTION AND ANALYSIS
We performed data collection and analyses according to the Cochrane Neonatal Review Group.
MAIN RESULTS
One small, high quality study assessing the effects of silicone earplugs versus no earplugs qualified for inclusion. The original inclusion criteria in our protocol stipulated an age of < 48 hours at the time of initiating sound reduction. We made a deviation from our protocol and included this study in which some infants would have been > 48 hours old. There was no significant difference in weight at 34 weeks postmenstrual age (PMA): mean difference (MD) 111 g (95% confidence interval (CI) -151 to 374 g) (n = 23). There was no significant difference in weight at 18 to 22 months corrected age between the groups: MD 0.31 kg, 95% CI -1.53 to 2.16 kg (n = 14). There was a significant difference in Mental Developmental Index (Bayley II) favouring the silicone earplugs group at 18 to 22 months corrected age: MD 14.00, 95% CI 3.13 to 24.87 (n = 12), but not for Psychomotor Development Index (Bayley II) at 18 to 22 months corrected age: MD -2.16, 95% CI -18.44 to 14.12 (n =12).
AUTHORS' CONCLUSIONS
To date, only 34 infants have been enrolled in a randomised controlled trial (RCT) testing the effectiveness of reducing sound levels that reach the infants' ears in the NICU. Based on the small sample size of this single trial, we cannot make any recommendations for clinical practice. Larger, well designed, conducted and reported trials are needed.
Topics: Ear Protective Devices; Employee Performance Appraisal; Health Personnel; Humans; Infant, Newborn; Infant, Premature; Infant, Very Low Birth Weight; Intensive Care Units, Neonatal; Noise; Randomized Controlled Trials as Topic; Sound; Stress, Physiological
PubMed: 31986231
DOI: 10.1002/14651858.CD010333.pub3 -
BMJ Clinical Evidence Nov 2014Acute atrial fibrillation is rapid, irregular, and chaotic atrial activity of recent onset. Various definitions of acute atrial fibrillation have been used in the... (Review)
Review
INTRODUCTION
Acute atrial fibrillation is rapid, irregular, and chaotic atrial activity of recent onset. Various definitions of acute atrial fibrillation have been used in the literature, but for the purposes of this review we have included studies where atrial fibrillation may have occurred up to 7 days previously. Risk factors for acute atrial fibrillation include increasing age, cardiovascular disease, alcohol, diabetes, and lung disease. Acute atrial fibrillation increases the risk of stroke and heart failure. The condition resolves spontaneously within 24 to 48 hours in more than 50% of people; however, many people will require interventions to control heart rate or restore sinus rhythm.
METHODS AND OUTCOMES
We conducted a systematic review and aimed to answer the following clinical questions: What are the effects of interventions to prevent embolism, for conversion to sinus rhythm, and to control heart rate in people with recent-onset atrial fibrillation (within 7 days) who are haemodynamically stable? We searched: Medline, Embase, The Cochrane Library, and other important databases up to April 2014 (Clinical Evidence reviews are updated periodically; please check our website for the most up-to-date version of this review). We included harms alerts from relevant organisations such as the US Food and Drug Administration (FDA) and the UK Medicines and Healthcare products Regulatory Agency (MHRA).
RESULTS
We found 26 studies that met our inclusion criteria. We performed a GRADE evaluation of the quality of evidence for interventions.
CONCLUSIONS
In this systematic review, we present information relating to the effectiveness and safety of the following interventions: amiodarone, antithrombotic treatment before cardioversion, atenolol, bisoprolol, carvedilol, digoxin, diltiazem, direct current cardioversion, flecainide, metoprolol, nebivolol, propafenone, sotalol, timolol, and verapamil.
Topics: Acute Disease; Anti-Arrhythmia Agents; Atrial Fibrillation; Electric Countershock; Humans; Safety
PubMed: 25430048
DOI: No ID Found -
The Cochrane Database of Systematic... Sep 2021This is an updated version of a Cochrane Review previously published in 2019. Catamenial epilepsy describes worsening seizures in relation to the menstrual cycle and may... (Review)
Review
BACKGROUND
This is an updated version of a Cochrane Review previously published in 2019. Catamenial epilepsy describes worsening seizures in relation to the menstrual cycle and may affect around 40% of women with epilepsy. Vulnerable days of the menstrual cycle for seizures are perimenstrually (C1 pattern), at ovulation (C2 pattern), and during the luteal phase (C3 pattern). A reduction in progesterone levels premenstrually and reduced secretion during the luteal phase is implicated in catamenial C1 and C3 patterns. A reduction in progesterone has been demonstrated to reduce sensitivity to the inhibitory neurotransmitter in preclinical studies, hence increasing risk of seizures. A pre-ovulatory surge in oestrogen has been implicated in the C2 pattern of seizure exacerbation, although the exact mechanism by which this surge increases risk is uncertain. Current treatment practices include the use of pulsed hormonal (e.g. progesterone) and non-hormonal treatments (e.g. clobazam or acetazolamide) in women with regular menses, and complete cessation of menstruation using synthetic hormones (e.g. medroxyprogesterone (Depo-Provera) or gonadotropin-releasing hormone (GnRH) analogues (triptorelin and goserelin)) in women with irregular menses. Catamenial epilepsy and seizure exacerbation is common in women with epilepsy. Women may not receive appropriate treatment for their seizures because of uncertainty regarding which treatment works best and when in the menstrual cycle treatment should be taken, as well as the possible impact on fertility, the menstrual cycle, bone health, and cardiovascular health. This review aims to address these issues to inform clinical practice and future research.
OBJECTIVES
To evaluate the efficacy and tolerability of hormonal and non-hormonal treatments for seizures exacerbated by the menstrual cycle in women with regular or irregular menses. We synthesised the evidence from randomised and quasi-randomised controlled trials of hormonal and non-hormonal treatments in women with catamenial epilepsy of any pattern.
SEARCH METHODS
We searched the following databases on 20 July 2021 for the latest update: Cochrane Register of Studies (CRS Web) and MEDLINE Ovid (1946 to 19 July 2021). CRS Web includes randomised controlled trials (RCTs) or quasi-RCTs from PubMed, Embase, ClinicalTrials.gov, the World Health Organization International Clinical Trials Registry Platform, the Cochrane Central Register of Controlled Trials (CENTRAL), and the specialised registers of Cochrane Review Groups including Cochrane Epilepsy. We used no language restrictions. We checked the reference lists of retrieved studies for additional reports of relevant studies.
SELECTION CRITERIA
We included RCTs and quasi-RCTs of blinded or open-label design that randomised participants individually (i.e. cluster-randomised trials were excluded). We included cross-over trials if each treatment period was at least 12 weeks in length and the trial had a suitable wash-out period. We included the following types of interventions: women with any pattern of catamenial epilepsy who received a hormonal or non-hormonal drug intervention in addition to an existing antiepileptic drug regimen for a minimum treatment duration of 12 weeks.
DATA COLLECTION AND ANALYSIS
We extracted data on study design factors and participant demographics for the included studies. The primary outcomes of interest were: proportion seizure-free, proportion of responders (at least 50% decrease in seizure frequency from baseline), and change in seizure frequency. Secondary outcomes included: number of withdrawals, number of women experiencing adverse events of interest (seizure exacerbation, cardiac events, thromboembolic events, osteoporosis and bone health, mood disorders, sedation, menstrual cycle disorders, and fertility issues), and quality of life outcomes.
MAIN RESULTS
Following title, abstract, and full-text screening, we included eight full-text articles reporting on four double-blind, placebo-controlled RCTs. We included two cross-over RCTs of pulsed norethisterone, and two parallel RCTs of pulsed progesterone recruiting a total of 192 women aged between 13 and 45 years with catamenial epilepsy. We found no RCTs for non-hormonal treatments of catamenial epilepsy or for women with irregular menses. Meta-analysis was not possible for the primary outcomes, therefore we undertook a narrative synthesis. For the two RCTs evaluating norethisterone versus placebo (24 participants), there were no reported treatment differences for change in seizure frequency. Outcomes for the proportion seizure-free and 50% responders were not reported. For the two RCTs evaluating progesterone versus placebo (168 participants), the studies reported conflicting results for the primary outcomes. One progesterone RCT reported no significant difference between progesterone 600 mg/day taken on day 14 to 28 and placebo with respect to 50% responders, seizure freedom rates, and change in seizure frequency for any seizure type. The other progesterone RCT reported a decrease in seizure frequency from baseline in the progesterone group that was significantly higher than the decrease in seizure frequency from baseline in the placebo group. The results of secondary efficacy outcomes showed no significant difference between groups in the pooled progesterone RCTs in terms of treatment withdrawal for any reason (pooled risk ratio (RR) 1.56, 95% confidence interval (CI) 0.81 to 3.00, P = 0.18, I = 0%) or treatment withdrawals due to adverse events (pooled RR 2.91, 95% CI 0.53 to 16.17, P = 0.22, I = 0%). No treatment withdrawals were reported from the norethisterone RCTs. The RCTs reported limited information on adverse events, although one progesterone RCT reported no significant difference in the number of women experiencing adverse events (diarrhoea, dyspepsia, nausea, vomiting, fatigue, nasopharyngitis, dizziness, headache, and depression). No studies reported on quality of life. We judged the evidence for outcomes related to the included progesterone RCTs to be of low to moderate certainty due to risk of bias, and for outcomes related to the included norethisterone RCTs to be of very low certainty due to serious imprecision and risk of bias.
AUTHORS' CONCLUSIONS
This review provides very low-certainty evidence of no treatment difference between norethisterone and placebo, and moderate- to low-certainty evidence of no treatment difference between progesterone and placebo for catamenial epilepsy. However, as all the included studies were underpowered, important clinical effects cannot be ruled out. Our review highlights an overall deficiency in the literature base on the effectiveness of a wide range of other hormonal and non-hormonal interventions currently being used in practice, particularly for those women who do not have regular menses. Further clinical trials are needed in this area.
Topics: Adolescent; Adult; Anticonvulsants; Epilepsy; Fatigue; Female; Humans; Menstruation; Middle Aged; Randomized Controlled Trials as Topic; Seizures; Young Adult
PubMed: 34528245
DOI: 10.1002/14651858.CD013225.pub3 -
BMJ Clinical Evidence Feb 2011Acute atrial fibrillation is rapid, irregular, and chaotic atrial activity of less than 48 hours' duration. Risk factors for acute atrial fibrillation include increasing... (Review)
Review
INTRODUCTION
Acute atrial fibrillation is rapid, irregular, and chaotic atrial activity of less than 48 hours' duration. Risk factors for acute atrial fibrillation include increasing age, cardiovascular disease, alcohol, diabetes, and lung disease. Acute atrial fibrillation increases the risk of stroke and heart failure. The condition resolves spontaneously within 24 to 48 hours in over 50% of people; however, many people will require interventions to control heart rate or restore sinus rhythm.
METHODS AND OUTCOMES
We conducted a systematic review and aimed to answer the following clinical questions: What are the effects of interventions to prevent embolism, for conversion to sinus rhythm, and to control heart rate in people with recent-onset atrial fibrillation (within 7 days) who are haemodynamically stable? We searched: Medline, Embase, The Cochrane Library, and other important databases up to April 2010 (Clinical Evidence reviews are updated periodically; please check our website for the most up-to-date version of this review). We included harms alerts from relevant organisations such as the US Food and Drug Administration (FDA) and the UK Medicines and Healthcare products Regulatory Agency (MHRA).
RESULTS
We found 30 systematic reviews, RCTs, or observational studies that met our inclusion criteria. We performed a GRADE evaluation of the quality of evidence for interventions.
CONCLUSIONS
In this systematic review we present information relating to the effectiveness and safety of the following interventions: amiodarone, antithrombotic treatment before cardioversion, digoxin, diltiazem, direct current cardioversion, flecainide, propafenone, quinidine, sotalol, timolol, and verapamil.
Topics: Amiodarone; Anti-Arrhythmia Agents; Atrial Fibrillation; Humans; Propafenone; Sotalol
PubMed: 21718559
DOI: No ID Found -
Health Technology Assessment... Jan 2020Atrial fibrillation (AF) is the most common type of cardiac arrhythmia and is associated with an increased risk of stroke and congestive heart failure. Lead-I...
BACKGROUND
Atrial fibrillation (AF) is the most common type of cardiac arrhythmia and is associated with an increased risk of stroke and congestive heart failure. Lead-I electrocardiogram (ECG) devices are handheld instruments that can be used to detect AF at a single time point in people who present with relevant signs or symptoms.
OBJECTIVE
To assess the diagnostic test accuracy, clinical impact and cost-effectiveness of using single time point lead-I ECG devices for the detection of AF in people presenting to primary care with relevant signs or symptoms, and who have an irregular pulse compared with using manual pulse palpation (MPP) followed by a 12-lead ECG in primary or secondary care.
DATA SOURCES
MEDLINE, MEDLINE Epub Ahead of Print and MEDLINE In-Process & Other Non-Indexed Citations, EMBASE, PubMed, Cochrane Databases of Systematic Reviews, Cochrane Central Database of Controlled Trials, Database of Abstracts of Reviews of Effects and the Health Technology Assessment Database.
METHODS
The systematic review methods followed published guidance. Two reviewers screened the search results (database inception to April 2018), extracted data and assessed the quality of the included studies. Summary estimates of diagnostic accuracy were calculated using bivariate models. An economic model consisting of a decision tree and two cohort Markov models was developed to evaluate the cost-effectiveness of lead-I ECG devices.
RESULTS
No studies were identified that evaluated the use of lead-I ECG devices for patients with signs or symptoms of AF. Therefore, the diagnostic accuracy and clinical impact results presented are derived from an asymptomatic population (used as a proxy for people with signs or symptoms of AF). The summary sensitivity of lead-I ECG devices was 93.9% [95% confidence interval (CI) 86.2% to 97.4%] and summary specificity was 96.5% (95% CI 90.4% to 98.8%). One study reported limited clinical outcome data. Acceptability of lead-I ECG devices was reported in four studies, with generally positive views. The de novo economic model yielded incremental cost-effectiveness ratios (ICERs) per quality-adjusted life-year (QALY) gained. The results of the pairwise analysis show that all lead-I ECG devices generated ICERs per QALY gained below the £20,000-30,000 threshold. Kardia Mobile (AliveCor Ltd, Mountain View, CA, USA) is the most cost-effective option in a full incremental analysis.
LIMITATIONS
No published data evaluating the diagnostic accuracy, clinical impact or cost-effectiveness of lead-I ECG devices for the population of interest are available.
CONCLUSIONS
Single time point lead-I ECG devices for the detection of AF in people with signs or symptoms of AF and an irregular pulse appear to be a cost-effective use of NHS resources compared with MPP followed by a 12-lead ECG in primary or secondary care, given the assumptions used in the base-case model.
FUTURE WORK
Studies assessing how the use of lead-I ECG devices in this population affects the number of people diagnosed with AF when compared with current practice would be useful.
STUDY REGISTRATION
This study is registered as PROSPERO CRD42018090375.
FUNDING
The National Institute for Health Research Health Technology Assessment programme.
Topics: Atrial Fibrillation; Cost-Benefit Analysis; Electrocardiography; Heart Failure; Humans; Mass Screening; Models, Economic; Predictive Value of Tests; Primary Health Care; Pulse; Quality-Adjusted Life Years; Stroke; Technology Assessment, Biomedical
PubMed: 31933471
DOI: 10.3310/hta24030 -
PloS One 2019Atrial fibrillation (AF) is the most common type of cardiac arrhythmia and is associated with increased risk of stroke and congestive heart failure. Lead-I...
Lead-I ECG for detecting atrial fibrillation in patients attending primary care with an irregular pulse using single-time point testing: A systematic review and economic evaluation.
BACKGROUND
Atrial fibrillation (AF) is the most common type of cardiac arrhythmia and is associated with increased risk of stroke and congestive heart failure. Lead-I electrocardiogram (ECG) devices are handheld instruments that can detect AF at a single-time point.
PURPOSE
To assess the diagnostic test accuracy, clinical impact and cost effectiveness of single-time point lead-I ECG devices compared with manual pulse palpation (MPP) followed by a 12-lead ECG for the detection of AF in symptomatic primary care patients with an irregular pulse.
METHODS
Electronic databases (MEDLINE, MEDLINE Epub Ahead of Print and MEDLINE In-Process, EMBASE, PubMed and Cochrane Databases of Systematic Reviews, Cochrane Central Database of Controlled Trials, Database of Abstracts of Reviews of Effects, Health Technology Assessment Database) were searched to March 2018. Two reviewers screened the search results, extracted data and assessed study quality. Summary estimates of diagnostic accuracy were calculated using bivariate models. Cost-effectiveness was evaluated using an economic model consisting of a decision tree and two cohort Markov models.
RESULTS
Diagnostic accuracy The diagnostic accuracy (13 publications reporting on nine studies) and clinical impact (24 publications reporting on 19 studies) results are derived from an asymptomatic population (used as a proxy for people with signs or symptoms of AF). The summary sensitivity of lead-I ECG devices was 93.9% (95% confidence interval [CI]: 86.2% to 97.4%) and summary specificity was 96.5% (95% CI: 90.4% to 98.8%). Cost effectiveness The de novo economic model yielded incremental cost effectiveness ratios (ICERs) per quality adjusted life year (QALY) gained. The results of the pairwise analysis show that all lead-I ECG devices generate ICERs per QALY gained below the £20,000-£30,000 threshold. Kardia Mobile is the most cost effective option in a full incremental analysis. Lead-I ECG tests may identify more AF cases than the standard diagnostic pathway. This comes at a higher cost but with greater patient benefit in terms of mortality and quality of life.
LIMITATIONS
No published data evaluating the diagnostic accuracy, clinical impact or cost effectiveness of lead-I ECG devices for the target population are available.
CONCLUSIONS
The use of single-time point lead-I ECG devices in primary care for the detection of AF in people with signs or symptoms of AF and an irregular pulse appears to be a cost effective use of NHS resources compared with MPP followed by a 12-lead ECG, given the assumptions used in the base case model.
REGISTRATION
The protocol for this review is registered on PROSPERO as CRD42018090375.
Topics: Aged; Aged, 80 and over; Atrial Fibrillation; Cost-Benefit Analysis; Electrocardiography; Female; Humans; Male; Markov Chains; Middle Aged; Primary Health Care; Pulse
PubMed: 31869370
DOI: 10.1371/journal.pone.0226671 -
Ultrasound in Obstetrics & Gynecology :... Dec 2022Fetal heart-rate irregularities occur in 1-2% of pregnancies and are usually caused by premature atrial contractions (PAC). Although PAC are considered benign, they may... (Meta-Analysis)
Meta-Analysis Review
OBJECTIVE
Fetal heart-rate irregularities occur in 1-2% of pregnancies and are usually caused by premature atrial contractions (PAC). Although PAC are considered benign, they may be associated with cardiac defects and tachyarrhythmia. We aimed to determine the incidence of congenital heart defects (CHDs) and complications in fetuses with PAC.
METHODS
This was a systematic review and meta-analysis conducted in accordance with the PRISMA statement for reporting items for systematic reviews and meta-analyses. MEDLINE and EMBASE were searched from 1990 to June 2021 to identify studies on fetuses with PAC. The primary outcome was CHD; secondary outcomes were complications using the endpoints supraventricular tachyarrhythmia (SVT), cardiac failure and intrauterine fetal demise. Meta-analysis of proportions was performed, subdivided into high-risk and low-risk populations based on reason for referral. Pooled incidences with 95% CIs were calculated.
RESULTS
Of 2443 unique articles identified, 19 cohort studies including 2260 fetuses were included. The pooled incidence of CHD in fetuses with PAC was 2.8% (95% CI, 1.5-4.1%), when 0.6% is the incidence expected in the general population. The pooled incidence of CHD was 7.2% (95% CI, 3.5-10.9%) in the high-risk population and 0.9% (95% CI, 0.0-2.0%) in the low-risk population. SVT occurred in 1.4% (95% CI, 0.6-3.4%) of fetuses diagnosed with PAC. Cardiac failure was described in 16 fetuses (1.4% (95% CI, 0.5-3.5%)), of which eight were CHD-related. Intrauterine fetal demise occurred in four fetuses (0.9% (95% CI, 0.5-1.7%)) and was related to CHD in two cases.
CONCLUSIONS
Our findings suggest that the risk of CHD in fetuses with PAC is 4-5 times higher than that in the general population. CHD was present more frequently in the high-risk population. Consequently, an advanced ultrasound examination to diagnose PAC correctly and exclude CHD is recommended. Complications of PAC are rare but can result in fetal demise, thus weekly fetal heart-rate monitoring remains advisable to enable early detection of SVT and to prevent cardiac failure. © 2022 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.
Topics: Pregnancy; Female; Humans; Fetal Diseases; Premature Birth; Fetal Death; Atrial Premature Complexes; Fetus; Tachycardia; Arrhythmias, Cardiac; Heart Failure
PubMed: 35763619
DOI: 10.1002/uog.26017 -
The Cochrane Database of Systematic... Jun 2016Atrial fibrillation (AF), the most common arrhythmia in clinical practice, is a leading cause of morbidity and mortality. Screening for AF in asymptomatic patients has... (Review)
Review
BACKGROUND
Atrial fibrillation (AF), the most common arrhythmia in clinical practice, is a leading cause of morbidity and mortality. Screening for AF in asymptomatic patients has been proposed as a way of reducing the burden of the disease by detecting people who would benefit from prophylactic anticoagulation therapy before the onset of symptoms. However, for screening to be an effective intervention, it must improve the detection of AF and provide benefit for those detected earlier as a result of screening.
OBJECTIVES
This review aims to answer the following questions.Does systematic screening increase the detection of AF compared with routine practice? Which combination of screening population, strategy and test is most effective for detecting AF compared with routine practice? What safety issues and adverse events may be associated with individual screening programmes? How acceptable is the intervention to the target population? What costs are associated with systematic screening for AF?
SEARCH METHODS
We searched the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE (Ovid) and EMBASE (Ovid) up to 11 November 2015. We searched other relevant research databases, trials registries and websites up to December 2015. We also searched reference lists of identified studies for potentially relevant studies, and we contacted corresponding authors for information about additional published or unpublished studies that may be relevant. We applied no language restrictions.
SELECTION CRITERIA
Randomised controlled trials comparing screening for AF with routine practice in people 40 years of age and older were eligible. Two review authors (PM and CT) independently selected trials for inclusion.
DATA COLLECTION AND ANALYSIS
Two review authors (PM and CT) independently assessed risk of bias and extracted data. We used odds ratios (ORs) and 95% confidence intervals (CIs) to present results for the primary outcome, which is a dichotomous variable. As we identified only one study for inclusion, we performed no meta-analysis. We used the GRADE (Grades of Recommendation, Assessment, Development and Evaluation Working Group) method to assess the quality of the evidence and GRADEPro to create a 'Summary of findings' table.
MAIN RESULTS
One cluster-randomised controlled trial met the inclusion criteria for this review. This study compared systematic screening (by invitation to have an electrocardiogram (ECG)) and opportunistic screening (pulse palpation during a general practitioner (GP) consultation for any reason, followed by an ECG if pulse was irregular) versus routine practice (normal case finding on the basis of clinical presentation) in people 65 years of age or older.Results show that both systematic screening and opportunistic screening of people over 65 years of age are more effective than routine practice (OR 1.57, 95% CI 1.08 to 2.26; and OR 1.58, 95% CI 1.10 to 2.29, respectively; both moderate-quality evidence). We found no difference in the effectiveness of systematic screening and opportunistic screening (OR 0.99, 95% CI 0.72 to 1.37; low-quality evidence). A subgroup analysis found that systematic screening and opportunistic screening were more effective in men (OR 2.68, 95% CI 1.51 to 4.76; and OR 2.33, 95% CI 1.29 to 4.19, respectively) than in women (OR 0.98, 95% CI 0.59 to 1.62; and OR 1.2, 95% CI 0.74 to 1.93, respectively). No adverse events associated with screening were reported.The incremental cost per additional case detected by opportunistic screening was GBP 337, compared with GBP 1514 for systematic screening. All cost estimates were based on data from the single included trial, which was conducted in the UK between 2001 and 2003.
AUTHORS' CONCLUSIONS
Evidence suggests that systematic screening and opportunistic screening for AF increase the rate of detection of new cases compared with routine practice. Although these approaches have comparable effects on the overall AF diagnosis rate, the cost of systematic screening is significantly greater than the cost of opportunistic screening from the perspective of the health service provider. Few studies have investigated effects of screening in other health systems and in younger age groups; therefore, caution needs to be exercised in relation to transferability of these results beyond the setting and population in which the included study was conducted.Additional research is needed to examine the effectiveness of alternative screening strategies and to investigate the effects of the intervention on risk of stroke for screened versus non-screened populations.
Topics: Aged; Asymptomatic Diseases; Atrial Fibrillation; Electrocardiography; Female; Humans; Male; Mass Screening; Palpation; Pulse; Randomized Controlled Trials as Topic
PubMed: 27258214
DOI: 10.1002/14651858.CD009586.pub3