JACC. Cardiovascular Interventions Dec 2021The aims of this study were to evaluate the rate and time course of delayed total atrioventricular block (DT-AVB) after transcatheter aortic valve replacement (TAVR)...
OBJECTIVES
The aims of this study were to evaluate the rate and time course of delayed total atrioventricular block (DT-AVB) after transcatheter aortic valve replacement (TAVR) using continuous electrocardiographic monitoring by implantable loop recorders and to identify potential predictors.
BACKGROUND
DT-AVB has been defined as onset more than 2 days after TAVR or after hospital discharge and is reported in 10% to 15% of patients at 30-day follow-up. To date, there is no standardized diagnostic and therapeutic algorithm to manage TAVR patients at risk for DT-AVB.
METHODS
Consecutive patients undergoing TAVR and simultaneous electrophysiologic testing without persistent or recurrent total atrioventricular block within 48 hours after the procedure underwent loop recorder implantation for full disclosure of atrioventricular conduction during 12-month follow-up.
RESULTS
DT-AVB occurred in 7 of 59 patients (11.9%), with onset between 2 days and 3 months after the procedure. Both prolongation of the PQ interval between baseline and day 2 after TAVR (OR: 1.04; 95% CI: 1.01-1.09); P = 0.032) and prolongation of the HV interval during the procedure (OR: 1.07; 95% CI: 1.02-1.14; P = 0.015) significantly predicted the onset of DT-AVB.
CONCLUSIONS
TAVR was associated with a considerable rate of DT-AVB of nearly 12% in this series. Prolongation of the PQ interval between baseline and day 2 and intraprocedural prolongation of the HV interval were significant predictors of DT-AVB.
Topics: Aortic Valve; Aortic Valve Stenosis; Atrioventricular Block; Electrocardiography; Humans; Risk Factors; Transcatheter Aortic Valve Replacement; Treatment Outcome
PubMed: 34949397
DOI: 10.1016/j.jcin.2021.09.003 -
Scandinavian Journal of Immunology Sep 2010Foetal echocardiographic ultrasound techniques still remain the dominating modality for diagnosing foetal atrioventricular block (AVB). Foetal electrocardiography might... (Review)
Review
Foetal echocardiographic ultrasound techniques still remain the dominating modality for diagnosing foetal atrioventricular block (AVB). Foetal electrocardiography might become a valuable tool to measure time intervals, but magnetocardiography is unlikely to get a place in clinical practice. Assuming that AVB is a gradually progressing and preventable disease, starting during a critical period in mid-gestation with a less abnormal atrioventricular conduction before progressing to a complete irreversible AVB (CAVB), echocardiographic methods to detect first-degree AVB have been developed. The time intervals obtained with these techniques are all based on the identification of mechanical or hemodynamic events as markers of atrial (A) and ventricular (V) depolarizations and will accordingly include both electrical and mechanical components. Prospective observational studies have demonstrated a transient prolongation of AV time intervals in anti-Ro/SSA antibody-exposed foetuses, but it has not succeeded to identify a degree of AV time prolongation predicting irreversible cardiac damage and progression to CAVB. Causes of sustained bradycardia include CAVB, 2:1 AVB, sinus bradycardia and blocked atrial bigeminy (BAB). Using foetal echocardiographic techniques and a systematic approach, a correct diagnosis can be made in almost every case. Sinus bradycardia and CAVB are usually easy to diagnose, but BAB has a tendency to be sustained and shows a high degree of resemblance with 2:1 AVB when diagnosed during mid-gestational. As BAB resolves without treatment and 2:1 AVB may respond to treatment with fluorinated steroids, a correct diagnosis becomes an issue of major importance to avoid unnecessary treatment of harmless and spontaneously reversing conditions.
Topics: Atrioventricular Block; Echocardiography, Doppler; Fetal Diseases; Heart Function Tests; Humans
PubMed: 20696017
DOI: 10.1111/j.1365-3083.2010.02434.x -
JACC. Cardiovascular Interventions May 2023Long-term right ventricular pacing (VP) has been related to negative left ventricular remodeling and heart failure (HF), but there is a lack of evidence regarding the...
BACKGROUND
Long-term right ventricular pacing (VP) has been related to negative left ventricular remodeling and heart failure (HF), but there is a lack of evidence regarding the prognostic impact on transcatheter aortic valve replacement (TAVR) patients.
OBJECTIVES
The aim of the PACE-TAVI registry is to evaluate the association of high percentage of VP with adverse outcomes in patients with pacemaker implantation after TAVR.
METHODS
PACE-TAVI is an international multicenter registry of all consecutive TAVR patients who underwent permanent pacemaker implantation for conduction disturbances in the first 30 days after the procedure. Patients were divided into 2 subgroups according to the percentage of VP (<40% vs ≥40%) at pacemaker interrogation. The primary endpoint was the composite of cardiovascular mortality or hospitalization for HF.
RESULTS
A total of 377 patients were enrolled, 158 with VP <40% and 219 with VP ≥40%. After multivariable adjustment, VP ≥40% was associated with a higher incidence of the primary endpoint (HR: 2.76; 95% CI: 1.39-5.51; P = 0.004), first HF hospitalization (HR: 3.37; 95% CI: 1.50-7.54; P = 0.003), and cardiovascular death (HR: 3.77; 95% CI: 1.02-13.88; P = 0.04), while the incidence of all-cause death was not significantly different (HR: 2.17; 95% CI: 0.80-5.90; P = 0.13). Patients with VP ≥ 40% showed a higher New York Heart Association functional class both at 1 year (P = 0.009) and at last available follow-up (P = 0.04) and a nonsignificant reduction of left ventricular ejection fraction (P = 0.18) on 1-year echocardiography, while patients with VP <40% showed significant improvement (P = 0.009).
CONCLUSIONS
In TAVR patients undergoing permanent pacemaker implantation, a high percentage of right VP at follow-up is associated with an increased risk for cardiovascular death and HF hospitalization. These findings suggest the opportunity to minimize right VP through dedicated algorithms in post-TAVR patients without complete atrioventricular block and to evaluate a more physiological VP modality in patients with persistent complete atrioventricular block.
Topics: Humans; Transcatheter Aortic Valve Replacement; Atrioventricular Block; Stroke Volume; Cardiac Pacing, Artificial; Aortic Valve Stenosis; Risk Factors; Ventricular Function, Left; Treatment Outcome; Pacemaker, Artificial; Aortic Valve
PubMed: 37164607
DOI: 10.1016/j.jcin.2023.02.003 -
Clinical Cardiology Mar 2018
Topics: Atrioventricular Block; Atrioventricular Node; Electrocardiography; Heart Rate; Humans
PubMed: 29460961
DOI: 10.1002/clc.22874 -
Europace : European Pacing,... Aug 2023Left bundle branch area pacing (LBBAP) is a potential alternative to His bundle pacing. This study aimed to investigate the impact of different septal locations of...
AIMS
Left bundle branch area pacing (LBBAP) is a potential alternative to His bundle pacing. This study aimed to investigate the impact of different septal locations of pacing leads on the diversity of QRS morphology during non-selective LBBAP.
METHODS AND RESULTS
Non-selective LBBAP and left ventricular septal pacing (LVSP) were achieved in 50 and 21 patients with atrioventricular block, respectively. The electrophysiological properties of LBBAP and their relationship with the lead location were investigated. QRS morphology and axis showed broad variations during LBBAP. Echocardiography demonstrated a widespread distribution of LBBAP leads in the septum. During non-selective LBBAP, the qR-wave in lead V1 indicated that the primary location for pacing lead was the inferior septum (93%). The non-selective LBBAP lead was deployed deeper than the LVSP lead in the inferior septum. The Qr-wave in lead V1 with the inferior axis in aVF suggested pacing lead placement in the anterior septum. The penetration depth of the non-selective LBBAP lead in the anterior septum was significantly shallower than that in the inferior septum (72 ± 11 and 87 ± 8%, respectively). In lead V6, the deep S-wave indicated the time lag between the R-wave peak and the latest ventricular activation in the coronary sinus trunk, with pacemaker leads deployed closer to the left ventricular apex.
CONCLUSION
Different QRS morphologies and axes were linked to the location of the non-selective LBBAP lead in the septum. Various lead deployments are feasible for LBBAP, allowing diversity in the conduction system capture in patients with atrioventricular block.
Topics: Humans; Atrioventricular Block; Ventricular Septum; Heart Conduction System; Heart Ventricles; Cardiac Conduction System Disease
PubMed: 37748089
DOI: 10.1093/europace/euad241 -
European Heart Journal Jun 2021
Topics: Atrioventricular Block; Humans; Pacemaker, Artificial; Physicians; Prognosis
PubMed: 33693637
DOI: 10.1093/eurheartj/ehab130 -
Medical Ultrasonography May 2021Congenital atrioventricular block (CAVB) is an immunological condition, secondary to the transfer of maternal Ig G antibodies from seropositive mothers. Although the...
AIM
Congenital atrioventricular block (CAVB) is an immunological condition, secondary to the transfer of maternal Ig G antibodies from seropositive mothers. Although the presence of these antibodies is high among pregnant women, the preva-lence of this fetal pathology is low. The aim of this paper is to analyze a series of cases with intrauterine diagnosis of CAVB and to present their follow-up protocol.
MATERIAL AND METHOD
In the period between 2013-2020, five fetuses were diagnosed and followed up in the Pediatric Cardiology Clinic. In each of the cases, assessment of the hemodynamic status was done by calculation of the fetal cardiovascular profile score (CVPS). In the last cases the follow-up protocol was supplemented with longitudinal speckle tracking evaluation of the ventricular function.
RESULTS
In the present series, intrauterine death occurred in one case; in another case resumption of atrioventricular conduction was observed. Epicardial pacemaker implantation was required in three of the patients.
CONCLUSION
Completing the evaluation of ventricular function with the longitudinal speckle tracking method in fetuses and newborn patients with congenital atrioventricular block may play an important role in establish-ing therapeutic behavior.
Topics: Atrioventricular Block; Female; Humans; Infant, Newborn; Pacemaker, Artificial; Pregnancy; Prenatal Diagnosis
PubMed: 33626113
DOI: 10.11152/mu-2723 -
American Journal of Physiology. Heart... Sep 2021Ventricular arrhythmias, consisting of single ectopic beats (sEB), multiple EB (mEB), and torsades de pointes (TdP, defined as ≥5 beats with QRS vector twisting around...
Ventricular arrhythmias, consisting of single ectopic beats (sEB), multiple EB (mEB), and torsades de pointes (TdP, defined as ≥5 beats with QRS vector twisting around isoelectric line) can be induced in the anesthetized chronic atrioventricular block (CAVB) dog by dofetilide ( blocker). The interplay between temporal dispersion of repolarization, quantified as short-term variability (STV), and spatial dispersion of repolarization (SDR) in the initiation and perpetuation of these arrhythmias remains unclear. Five inducible (≥3 TdPs/10 min) CAVB dogs underwent one mapping experiment and were observed for 10 min from the start of dofetilide infusion (0.025 mg/kg, 5 min). An intracardiac decapolar electrogram (EGM) catheter and 30 intramural cardiac needles in the left ventricle (LV) were introduced. STV was derived from 31 consecutive activation recovery intervals (ARIs) on the intracardiac EGM, using the formula: [Formula: see text]. The mean SDR in the LV was determined as the three-dimensional repolarization time differences between the intramural cardiac needles. Moments of measurement included baseline (BL) and after dofetilide infusion before first ) sEB (occurrence at 100 ± 35 s), ) mEB (224 ± 96 s), and ) non-self-terminating TdP (454 ± 298 s). STV increased from 2.15 ± 0.32 ms at BL to 3.73 ± 0.99 ms* before the first sEB and remained increased without further significant progression to mEB (4.41 ± 0.45 ms*) and TdP (5.07 ± 0.84 ms*) (* < 0.05 compared with BL). SDR did not change from 31 ± 11 ms at BL to 43 ± 13 ms before sEB but increased significantly before mEB (68 ± 7 ms*) and to TdP (86 ± 9 ms*) ( < 0.05 compared with sEB). An increase in STV contributes to the initiation of sEB, whereas an increase in SDR is important for the perpetuation of non-self-terminating TdPs. This study compared two well-established electrophysiological parameters, being temporal and spatial dispersion of repolarization, and provided new insights into their interplay in the arrhythmogenesis of torsades de pointes arrhythmias. Although it confirmed that an increase in temporal dispersion of repolarization contributes to the initiation of single ectopic beats, it showed that an increase in spatial dispersion of repolarization is important for the perpetuation of non-self-terminating torsades de pointes arrhythmias.
Topics: Action Potentials; Animals; Atrioventricular Block; Dogs; Female; Male; Models, Cardiovascular; Reaction Time; Torsades de Pointes
PubMed: 34355987
DOI: 10.1152/ajpheart.00945.2020 -
Annals of Noninvasive Electrocardiology... May 2013First-degree atrioventricular (AV) block is a delay within the AV conduction system and is defined as a prolongation of the PR interval beyond the upper limit of what is... (Review)
Review
First-degree atrioventricular (AV) block is a delay within the AV conduction system and is defined as a prolongation of the PR interval beyond the upper limit of what is considered normal (generally 0.20 s). Up until recently, first-degree AV block was considered an entirely benign condition. In fact, some complain that it is a misnomer since there is only delay and no actual block in the AV conduction system (usually within the AV node). However, it has long been acknowledged that extreme forms of first-degree AV block (typically a PR interval exceeding 0.30 s) can cause symptoms due to inadequate timing of atrial and ventricular contractions, similar to the so-called pacemaker syndrome. Consequently, the current guidelines state that permanent pacemaker implantation is reasonable for first-degree AV block with symptoms similar to those of pacemaker syndrome or with hemodynamic compromise, but also stresses that there is little evidence to suggest that pacemakers improve survival in patients with isolated first-degree AV block. Recent reports suggest that it may be time to revisit the impact of first-degree AV block. Also, several findings in post hoc analyses of randomized device trials give important insights in possible treatment options. The present review aims to provide an update on the current knowledge concerning the impact of first-degree AV block and also to address the issue of pacing in patients with this condition.
Topics: Atrioventricular Block; Cardiac Pacing, Artificial; Coronary Disease; Heart Conduction System; Heart Failure; Humans; Incidence; Risk Factors
PubMed: 23714079
DOI: 10.1111/anec.12062 -
BMC Cardiovascular Disorders Nov 2023This article summarizes the treatment experience for congenital complete atrioventricular block (CCAVB) in newborns and infants, and discusses the necessity and...
BACKGROUND
This article summarizes the treatment experience for congenital complete atrioventricular block (CCAVB) in newborns and infants, and discusses the necessity and feasibility of treating CCAVB with permanent pacemaker implantation in this population.
METHODS
In this study, the clinical data and follow-up results of nine children admitted at our center with CCAVB from January 2005 to March 2023 were retrospectively analyzed. Among them, two children received early implantation of permanent pacemakers (within 1 year of age), two children received non-early implantation (1 year or older), and the remaining five children received no pacemaker implantation. CCAVB diagnosis was confirmed by clinical symptoms and clinical examinations, including electrocardiography and echocardiography before surgery. After surgery, the pacing and sensing functions of the pacemaker were observed using electrocardiography, echocardiography, and pacing threshold monitoring. A comprehensive assessment of the treatment efficacy was conducted, encompassing improvements in clinical symptoms, growth and development, as well as the absence of any additional potential complications. The children who did not receive pacemaker implantation were followed up.
RESULTS
Among the four children who successfully received pacemaker implantation, one child who received non-early implantation died. For the remaining three children, the threshold level, amplitude, impedance, and minute ventilation sensor function of the pacemaker were good during the follow-up period, with a heart rate at the pacing rate. The growth and development of the aforementioned patients who received pacemaker implantation demonstrated adherence to the percentile curve, and their motor and cognitive development remained unaffected. However, among the children who did not undergo pacemaker implantation, two experienced death, while three were lost to follow-up, thereby limiting the evaluation of their long-term outcomes.
CONCLUSIONS
Early implantation of an epicardial pacemaker at an early stage in newborns and infants diagnosed with CCAVB can significantly improve clinical symptoms without affecting their growth and development. These data are in line with current literature and suggest that early implantation of an epicardial pacemaker in newborns and infants diagnosed with CCAVB but further studies are needed.
Topics: Child; Humans; Infant; Infant, Newborn; Child, Preschool; Retrospective Studies; Atrioventricular Block; Cardiac Pacing, Artificial; Follow-Up Studies; Pacemaker, Artificial
PubMed: 37990158
DOI: 10.1186/s12872-023-03620-1