Cureus Feb 2022Introduction Implantation of cardiac implantable electronic devices (CIEDs) is an art of science. As the volume of implantation has increased worldwide, so has the rate...
Introduction Implantation of cardiac implantable electronic devices (CIEDs) is an art of science. As the volume of implantation has increased worldwide, so has the rate of complications. Infection, fibrosis, lead and device erosion, lead displacement, right ventricle perforation, lead fracture, and insulation break are the common complications in the implantation process. This exposes the patient for reopening and threatens the implantation for further complication due to infection, fibrosis of veins, failure to retrieve the implanted wire, and failure to re-implant the device on the same site. We slightly changed our implantation technique to preserve the implantation site for future implantation and reduce the rate of complication in the index implantation. Methods This randomized control trial was conducted from January 2016 to September 2019 at Hayatabad Medical Complex Peshawar, Pakistan. A consecutive sampling technique was used to obtain a sample size of 602 patients keeping a 95% confidence interval and a 5% margin error. We adopted a strategy to take prick, for implantation of devices, inside the pocket, which reduces the number of sutures, hastens the procedure, prevents erosion, and minimizes the chance of subclavian crush syndrome and insulation break. We also selected the minimum possible length of leads. This will possibly decrease the chances of cumbersome fibrosis around the lead and device and will make future implantation convenient. Results There was a total of 602 procedures in the study period. About 253 (42%) procedures were done in the newly adopted strategy and 349 (58%) were performed in the conventional way. Our complication rate grossly reduces in the novel way of implantation in which we took our prick inside the pocket. Conclusion A slight modification in the implantation of CIEDs not only prevents the rate of complication in the index implantation but will also possibly preserve the site for future implantation.
PubMed: 35350505
DOI: 10.7759/cureus.22259 -
World Journal of Cardiology Mar 2022Cardiovascular implantable electronic devices (CIEDs) are implanted in an increasing number of patients each year, which has led to an increase in the risk of CIED...
BACKGROUND
Cardiovascular implantable electronic devices (CIEDs) are implanted in an increasing number of patients each year, which has led to an increase in the risk of CIED infection. Antibacterial CIED envelopes locally deliver antibiotics to the implant site over a short-term period and have been shown to reduce the risk of implant site infection. These envelopes are derived from either biologic or non-biologic materials. There is a paucity of data examining patient risk profiles and outcomes from using these envelope materials in the clinical setting and comparing these results to patients receiving no envelope with their CIED implantation.
AIM
To evaluate risk profiles and outcomes of patients who underwent CIED procedures with an antibacterial envelope or no envelope.
METHODS
After obtaining Internal Review Board approval, the records of consecutive patients who underwent a CIED implantation procedure by a single physician between March 2017 and December 2019 were retrospectively collected from our hospital. A total of 248 patients within this period were identified and reviewed through 12 mo of follow up. The CIED procedures used either no envelope ( = 57), a biologic envelope (CanGaroo, Aziyo Biologics) that was pre-hydrated by the physician with vancomycin and gentamicin ( = 89), or a non-biologic envelope (Tyrx™, Medtronic) that was coated with a resorbable polymer containing the drug substances rifampin and minocycline by the manufacturer ( = 102). Patient selection for receiving either no envelope or an envelope (and which envelope to use) was determined by the treating physician. Statistical analyses were performed between the 3 groups (CanGaroo, Tyrx, and no envelope), and also between the No Envelope and Any Envelope groups by an independent, experienced biostatistician.
RESULTS
On average, patients who received any envelope (biologic or non-biologic) were younger (70.7 ± 14.0 74.9 ± 10.6, = 0.017), had a greater number of infection risk factors (81.2% 49.1%, < 0.001), received more high-powered devices (37.2% 5.8%, = 0.004), and were undergoing more reoperative procedures (47.1% 0.0%, < 0.001) than patients who received no envelope. Between the two envelopes, biologic envelopes tended to be used more often in higher risk patients (84.3% 78.4%) and reoperative procedures (62.9% 33.3%) than non-biologic envelopes. The rate of CIED implant site pocket infection was low (any envelope 0.5% no envelope 0.0%) and was statistically equivalent between the two envelope groups. Other reported adverse events (lead dislodgement, lead or pocket revision, device migration or erosion, twiddler's syndrome, and erythema/fever) were low and statistically equivalent between groups (biologic 2.2%, non-biologic 3.9%, no envelope 1.8%).
CONCLUSION
CIED infection rates for biologic and non-biologic antibacterial envelopes are similar. Antibacterial envelopes may benefit patients who are higher risk for infection, however additional studies are warranted to confirm this.
PubMed: 35432770
DOI: 10.4330/wjc.v14.i3.177 -
Indian Pacing and Electrophysiology... 2020Insertable cardiac monitors (ICMs) are often used for long-term monitoring of cardiac rhythm. The Medtronic's LINQ Reveal ™ is a new generation wireless, automated,...
BACKGROUND
Insertable cardiac monitors (ICMs) are often used for long-term monitoring of cardiac rhythm. The Medtronic's LINQ Reveal ™ is a new generation wireless, automated, and patient responsive subcutaneous ECG monitoring device. Despite several advantages to its small size we have noted an unusually high incidence of extrusion at our center.
METHODS
& Results: We conducted a retrospective case analysis to review Reveal LINQs implanted at our center. All devices were inserted using the provided insertion tools. Patients with extruded devices were identified and details regarding the site and technique of insertion, incision closure, use of peri-operative antibiotics, and follow-up details were collected. 81 patients underwent 85 Reveal LINQ implants at a tertiary care University Hospital referral center. The most common reason for implant was suspected arrhythmia with or without structural heart disease or unexplained syncope. There were 4 spontaneous extrusions occurring within 7-24 days after insertion with an incidence rate of 4.7%. One extruded device was anchored to subcutaneous tissue, and no pocket/device infections or hematomas were noted.
CONCLUSIONS
Device migration and erosion through skin are important potential adverse events for the Reveal LINQ implantable loop recorder. This study reports an unexpectedly high rate of extrusion without infection. The authors suggest that the depth of the incision is the main factor impacting extrusions. Larger studies are recommended, however, and a proposed measure to avoid spontaneous extrusion is the design of a longer manufacturer's blade in order to increase the depth of the incision and insertion.
PubMed: 32298763
DOI: 10.1016/j.ipej.2020.04.005 -
Indian Journal of Otolaryngology and... Dec 2019The tympanic membrane retraction pocket is a pathological invagination of tympanic membrane into the middle ear space. The most common sites for formation of retraction...
The tympanic membrane retraction pocket is a pathological invagination of tympanic membrane into the middle ear space. The most common sites for formation of retraction pocket are pars flaccida and postero-superior parts. Decision about the procedure and the timing of the treatment of retraction pockets is debatable and depends on the functional and anatomic condition of the ear. To evaluate the results of the technique of two handed endoscopic management of retraction pockets with sliced tragal cartilage. Prospective Non Randomized Clinical Study. The study included 41 ears operated with the technique of two handed endoscopic cartilage tympanoplasty for retraction pockets with endoscope holders from November 2013 to May 2016 with a follow up period ranging from 22 to 53 months. Cases of cholesteatoma and tympanic membrane perforation were excluded from the study. Pre and postoperative symptoms and air-bone gaps were recorded. The average preoperative air-bone gap in the study group was 24.53 ± 4.326 dB. 28 ears were of pars tensa retractions (stage II-4, stage III-15, and stage IV-9) and 13 were pars flaccida retractions (stage III-8 and stage IV-5). 24 ears had ossicular erosion. The follow up revealed that, the results of two handed endoscopic sliced cartilage tympanoplasty for retraction pockets were stable and there was no recurrence of the retraction and the post-operative air-bone-gap closure was achieved to 13.62 ± 4.78, 14.13 ± 5.91 dB, 14.32 ± 3.46 and 14.57 ± 3.88 dB at 6 months, 1 year, 2 years, 3 years respectively. Though, indications for surgery are based mostly on anatomic status and observation of behaviour of retraction pocket over time, we recommend early management of retraction pockets by the technique of endoscopic sliced tragal cartilage tympanoplasty with tragal cartilage of 0.5 mm thickness using endoscope holder. : Level 4.
PubMed: 31750111
DOI: 10.1007/s12070-019-01682-2 -
Frontiers in Cardiovascular Medicine 2022A pocket hematoma is a well-recognized complication that occurs after pacemaker or defibrillator implantation. It is associated with increased pocket infection and...
BACKGROUND
A pocket hematoma is a well-recognized complication that occurs after pacemaker or defibrillator implantation. It is associated with increased pocket infection and hospital stay. Patients suffering from atrial fibrillation and undergoing cardiovascular electronic implantable device (CIED) surgery are widely prescribed and treated with direct oral anticoagulants (DOACs). In this study, the use of a novel compression device was evaluated to examine its ability to decrease the incidence of pocket hematomas following device implantation with uninterrupted DOACs.
METHODS
A total of 204 participants who received DOACs and underwent CIED implantation were randomized into an experimental group (novel compression device) and a control group (elastic adhesive tape with a sandbag). The primary outcome was pocket hematoma, and the secondary outcomes were skin erosions and patient comfort score. Grade 3 hematoma was defined as a hematoma that required anticoagulation therapy interruption, re-operation, or prolonged hospital stay.
RESULTS
The baseline characteristics of both groups had no significant differences. The incidence of grades 1 and 2 hematomas was significantly lower in the compression device group than in the conventional pressure dressing group (7.8 vs. 23.5 and 2.0 vs. 5.9%, respectively; < 0.01). Grade 3 hematoma occurred in 2 of 102 patients in the experimental group and 7 of 102 patients in the control group (2.0 vs. 6.9%; = 0.03). The incidence rates of skin erosion were significantly lower, and the patient comfort score was much higher in the compression device group than in the control group ( < 0.01). Multivariable logistic regression analysis showed that the use of novel compression device was a significant protective factor for pocket hematoma (OR = 0.42; 95% CI, 0.29-0.69, = 0.01).
CONCLUSIONS
The incidence of pocket hematomas and skin erosions significantly decreases when the proposed compression device is used for patients undergoing device implantation with uninterrupted DOACs. Thus, the length of hospital stay and re-operation rate can be reduced, and patient comfort can be improved.
CLINICAL TRIAL REGISTRATION
http://www.chictr.org.cn, identifier: ChiCTR2100049430.
PubMed: 35282349
DOI: 10.3389/fcvm.2022.817453 -
British Dental Journal Jun 2016Background Reducing sugar consumption is a primary focus of current global public health policy. Achieving 5% of total energy from free sugars will be difficult...
Background Reducing sugar consumption is a primary focus of current global public health policy. Achieving 5% of total energy from free sugars will be difficult acknowledging the concentration of free sugars in sugar sweetened beverages, confectionery and as hidden sugars in many savoury items. The expansion of the novelty sweet market in the UK has significant implications for children and young adults as they contribute to dental caries, dental erosion and obesity.Objective To identify the most available types of novelty sweets within the high school fringe in Cardiff, UK and to assess their price range and where and how they were displayed in shops.Subjects and methods Shops within a ten minute walking distance around five purposively selected high schools in the Cardiff aea representing different levels of deprivation were visited. Shops in Cardiff city centre and three supermarkets were also visited to identify the most commonly available novelty sweets.Results The ten most popular novelty sweets identified in these scoping visits were (in descending order): Brain Licker, Push Pop, Juicy Drop, Lickedy Lips, Big Baby Pop, Vimto candy spray, Toxic Waste, Tango candy spray, Brain Blasterz Bitz and Mega Mouth candy spray. Novelty sweets were located on low shelves which were accessible to all age-groups in 73% (14 out of 19) of the shops. Novelty sweets were displayed in the checkout area in 37% (seven out of 19) shops. The price of the top ten novelty sweets ranged from 39p to £1.Conclusion A wide range of acidic and sugary novelty sweets were easily accessible and priced within pocket money range. Those personnel involved in delivering dental and wider health education or health promotion need to be aware of recent developments in children's confectionery. The potential effects of these novelty sweets on both general and dental health require further investigation.
Topics: Adolescent; Beverages; Candy; Commerce; Dental Caries; Food; Humans; Oral Health; Schools; Wales
PubMed: 27283564
DOI: 10.1038/sj.bdj.2016.412 -
Archives of Plastic Surgery Jan 2017Skin erosion is a dire complication of implantable cardiac pacemakers and defibrillators. Classical treatments involve removal of the entire generator and lead systems,...
BACKGROUND
Skin erosion is a dire complication of implantable cardiac pacemakers and defibrillators. Classical treatments involve removal of the entire generator and lead systems, however, these may result in fatal complications. In this study, we present our experience with a simplified salvage technique for exposed implantable cardiac electronic devices (ICEDs) without removing the implanted device, in an attempt to reduce the risks and complication rates associated with this condition.
METHODS
The records of 10 patients who experienced direct ICED exposure between January 2012 and December 2015 were retrospectively reviewed. The following surgical procedure was performed in all patients: removal of skin erosion and capsule, creation of a new pocket at least 1.0-1.5 cm inferior to its original position, migration of the ICED to the new pocket, and insertion of closed-suction drainage. Patients with gross local sepsis or septicemia were excluded from this study.
RESULTS
Seven patients had cardiac pacemakers and the other 3 had implantable cardiac defibrillators. The time from primary ICED placement to exposure ranged from 0.3 to 151 months (mean, 29 months. Postoperative follow-up in this series ranged from 8 to 31 months (mean follow-up, 22 months). Among the 10 patients, none presented with any signs of overt infection or cutaneous lesions, except 1 patient with hematoma on postoperative day 5. The hematoma was successfully treated by surgical removal and repositioning of the closed-suction drainage.
CONCLUSIONS
Based on our experience, salvage of exposed ICEDs is possible without removing the device in selected patients.
PubMed: 28194346
DOI: 10.5999/aps.2017.44.1.42 -
Health and Human Rights Dec 2019Through focusing on the neoliberal "Health Transformation Programme" launched in 2003 in Turkey, I show how reproductive law can be modified by neoliberal mechanisms...
Through focusing on the neoliberal "Health Transformation Programme" launched in 2003 in Turkey, I show how reproductive law can be modified by neoliberal mechanisms that are implemented with neoconservative policies and pressures. The paper builds on original data collected in 2014 and 2015 through focus groups and interviews with health practitioners in family health centers and women receiving reproductive care in Izmir, Diyarbakir, Van, and Gaziantep. The data analysis informed by writings on the debt economy by Maurizio Lazzarato and Bifo Berardi and transnational feminist theory demonstrate that neoliberal mechanisms of "dismantling the public" interact with pronatalist policies and pressures to erode women's reproductive rights in Turkey. This has resulted in (1) indebtedness of women through out-of-pocket payments for contraception and abortion, (2) indebtedness of providers through performance measures, (3) reduction in the quality of reproductive care, and (4) reduction in access to reproductive care itself (contraception, counseling, and abortion). There is a need to pay attention to neoliberal mechanisms and the legal framings of reproductive rights to fully understand the limitations of law and counter the neoliberal and conservative assaults on women's sexual and reproductive rights.
Topics: Abortion, Induced; Adult; Contraception; Female; Focus Groups; Health Expenditures; Health Services Accessibility; Health Surveys; Humans; Interviews as Topic; Politics; Pregnancy; Reproductive Rights; Turkey; Women's Rights
PubMed: 31885436
DOI: No ID Found -
Scientific Reports Nov 2022The effect of gas-entrapping polydimethylsiloxane (PDMS) microstructures on the dynamics of cavitation bubbles laser-induced next to the PDMS surface is investigated and...
The effect of gas-entrapping polydimethylsiloxane (PDMS) microstructures on the dynamics of cavitation bubbles laser-induced next to the PDMS surface is investigated and compared against the cavitation dynamics next to a flat smooth boundary. Local pressure gradients produced by a cavitation bubble cause the air pockets entrapped in the PDMS microstructures to expand and oscillate, leading to a repulsion of the cavitation bubble. The microstructures were fabricated as boxed crevices via a simple and scalable laser ablation technique on cast acrylic, allowing for testing of variable structure sizes and reusable molds. The bubble dynamics were observed using high speed photography and the surrounding flows were visualized and quantified using particle tracking velocimetry. Smaller entrapped air pockets showed an enhanced ability to withstand deactivation at three stand-off distances and over 50 subsequent cavitation events. This investigation provides insight into the potential to direct the collapse of a cavitation bubble away from a surface to mitigate erosion or to enhance microfluidic mixing in low Reynolds number flows.
PubMed: 36437305
DOI: 10.1038/s41598-022-24746-w -
Genetics, Selection, Evolution : GSE Jul 2020Assessment of genetic diversity and population structure provides important control metrics to avoid genetic erosion, inbreeding depression and crossbreeding between...
BACKGROUND
Assessment of genetic diversity and population structure provides important control metrics to avoid genetic erosion, inbreeding depression and crossbreeding between exotic and locally-adapted cattle breeds since these events can have deleterious consequences and eventually lead to extinction. Historically, the Alpine Arc represents an important pocket of cattle biodiversity with a large number of autochthonous breeds that provide a fundamental source of income for the entire regional economy. By using genotype data from medium-density single nucleotide polymorphism (SNP) arrays, we performed a genome-wide comparative study of 23 cattle populations from the Alpine Arc and three cosmopolitan breeds.
RESULTS
After filtering, we obtained a final genotyping dataset consisting of 30,176 SNPs for 711 individuals. The local breeds showed high or intermediate values of genetic diversity compared to the highly selected cosmopolitan breeds. Patterns of genetic differentiation, multidimensional scaling, admixture analysis and the constructed phylogenetic tree showed convergence, which indicates the presence of gene flow among the breeds according to both geographic origin and historical background. Among the most differentiated breeds, we identified the modern Brown cattle. In spite of admixture events, several local breeds have preserved distinctive characteristics, which is probably due to differences in genetic origin and geographic location.
CONCLUSIONS
This study represents one of the most comprehensive genome-wide analysis of the Alpine cattle breeds to date. Using such a large dataset that includes the majority of the local breeds found in this region, allowed us to expand knowledge on the evaluation and status of Alpine cattle biodiversity. Our results indicate that although many of the analyzed local breeds are listed as endangered, they still harbor a large amount of genetic diversity, even when compared to some cosmopolitan breeds. This finding, together with the reconstruction of the phylogeny and the relationships between these Alpine Arc cattle breeds, provide crucial insights not only into the improvement of genetic stocks but also into the implementation of future conservation strategies.
Topics: Animals; Cattle; Evolution, Molecular; Genotype; Phylogeny; Polymorphism, Single Nucleotide
PubMed: 32664855
DOI: 10.1186/s12711-020-00559-1