Hellenic Journal of Cardiology : HJC =... 2016Cardiac rhythm management devices (CRMDs) have proven their clinical effectiveness for patients with heart rhythm disorders. Little is known about safety and...
INTRODUCTION
Cardiac rhythm management devices (CRMDs) have proven their clinical effectiveness for patients with heart rhythm disorders. Little is known about safety and complication rates during the implantation of these devices. This study demonstrated the complication rates related to CRMD implantation, and estimated the additional hospital stay and cost associated with the management of complications.
METHODS
During a period of one year, a total of 464 consecutive recipients underwent CRMD implantation and were followed for 2 years. Finally, data were analyzed for 398 patients who completed the two-year follow up, resulting in a total of 796 patient-years.
RESULTS
Of the 201 patients with initial pacemaker (PM) implantations, 6 (2.99%) had seven complications (5 patients had lead dislodgement, 1 of them twice), and 1 patient developed pocket infection. Of the 117 PM replacements, 1 (0.85%) patient developed a complication (pocket erosion). Two patients with complications (1 with an initial PM and 1 with a replacement) died before completing the follow up for reasons unrelated to cardiac causes. There were no complications in either initial implantations (69 patients) or replacements (11 patients) of implantable cardioverter-defibrillators. The average prolongation of the hospital stay was 7 days, ranging from 1 to 35 days, resulting in 17,411 of total additional direct hospital costs.
CONCLUSION
This study found relatively low rates of complications in patients undergoing CRMD implantation, initial or replacement, in our center, compared with other studies. The additional hospitalization days and costs attributable to these complications depend on the nature of the complication.
Topics: Arrhythmias, Cardiac; Cost of Illness; Defibrillators, Implantable; Female; Humans; Length of Stay; Male; Pacemaker, Artificial; Postoperative Complications; Prospective Studies; Surveys and Questionnaires; Treatment Outcome
PubMed: 26856199
DOI: 10.1016/s1109-9666(16)30016-1 -
The Pan African Medical Journal 2013Permanent pacemaker implantation is available in Nigeria. There is however no national registry or framework for pacemaker data collection. A pacemaker database has been...
INTRODUCTION
Permanent pacemaker implantation is available in Nigeria. There is however no national registry or framework for pacemaker data collection. A pacemaker database has been developed in our institution and the results are analyzed in this study.
METHODS
The study period was between January 2008 and December 2012. Patient data was extracted from a prospectively maintained database which was designed to include the fields of the European pacemaker patient identification code.
RESULTS
Of the 51 pacemaker implants done, there were 29 males (56.9%) and 22 females (43.1%). Mean age was 68.2±12.7 years. Clinical indications were syncopal attacks in 25 patients (49%), dizzy spells in 15 patients (29.4%), bradycardia with no symptoms in 10 patients (17.7%) and dyspnoea in 2 patients (3.9%). The ECG diagnosis was complete heart block in 27 patients (53%), second degree heart block in 19 patients (37.2%) and sick sinus syndrome with bradycardia in 5 patients (9.8%). Pacemaker modes used were ventricular pacing in 29 patients (56.9%) and dual chamber pacing in 22 patients (43.1%). Files have been closed in 20 patients (39.2%) and 31 patients (60.8%) are still being followed up with median follow up of 26 months, median of 5 visits and 282 pacemaker checks done. Complications seen during follow up were 3 lead displacements (5.9%), 3 pacemaker infections (5.9%), 2 pacemaker pocket erosions (3.9%), and 1 pacemaker related death (2%). There were 5 non-pacemaker related deaths (9.8%).
CONCLUSION
Pacemaker data has been maintained for 5 years. We urge other implanting institutions in Nigeria to maintain similar databases and work towards establishment of a national pacemaker registry.
Topics: Aged; Aged, 80 and over; Bradycardia; Databases, Factual; Female; Follow-Up Studies; Health Services Needs and Demand; Hospitals, Teaching; Humans; Male; Middle Aged; Nigeria; Pacemaker, Artificial; Prosthesis Implantation; Retrospective Studies
PubMed: 24498465
DOI: 10.11604/pamj.2013.16.16.2644 -
PloS One 2014Foliar tissue samples of cultivated daylilies (Hemerocallis hybrids) showing the symptoms of a newly emergent foliar disease known as 'spring sickness' were investigated...
Foliar tissue samples of cultivated daylilies (Hemerocallis hybrids) showing the symptoms of a newly emergent foliar disease known as 'spring sickness' were investigated for associated fungi. The cause(s) of this disease remain obscure. We isolated repeatedly a fungal species which proved to be member of the genus Botrytis, based on immunological tests. DNA sequence analysis of these isolates, using several different phyogenetically informative genes, indicated that they represent a new Botrytis species, most closely related to B. elliptica (lily blight, fire blight) which is a major pathogen of cultivated Lilium. The distinction of the isolates was confirmed by morphological analysis of asexual sporulating cultures. Pathogenicity tests on Hemerocallis tissues in vitro demonstrated that this new species was able to induce lesions and rapid tissue necrosis. Based on this data, we infer that this new species, described here as B. deweyae, is likely to be an important contributor to the development of 'spring sickness' symptoms. Pathogenesis may be promoted by developmental and environmental factors that favour assault by this necrotrophic pathogen. The emergence of this disease is suggested to have been triggered by breeding-related changes in cultivated hybrids, particularly the erosion of genetic diversity. Our investigation confirms that emergent plant diseases are important and deserve close monitoring, especially in intensively in-bred plants.
Topics: Base Sequence; Botrytis; DNA, Intergenic; Genes, Mating Type, Fungal; Hemerocallis; Molecular Sequence Data; Phylogeny; Plant Diseases; Plant Leaves; Sequence Alignment; Sequence Analysis, DNA; Spores, Fungal; Sterilization
PubMed: 24887415
DOI: 10.1371/journal.pone.0089272 -
British Heart Journal Jun 1995To evaluate the incidence of intraoperative and early postoperative complications (up to two months after implant) of endocardial permanent pacemaker insertion in all... (Comparative Study)
Comparative Study
OBJECTIVE
To evaluate the incidence of intraoperative and early postoperative complications (up to two months after implant) of endocardial permanent pacemaker insertion in all patients under-going a first implant at a referral centre.
METHODS
Prospective evaluation of all endocardial pacemaker implantation procedures performed from April 1992 to January 1994 carried out by completion of standard audit form at implant. Patients' demographic data, medical history, details of pacemaker hardware used, and any complications were noted. Follow up information was also collected prospectively onto standard forms at pacemaker outpatient clinic.
SETTING
United Kingdom tertiary referral cardiothoracic centre.
PATIENTS
1088 consecutive patients underwent implantation of their first endocardial permanent pacemaker from April 1992 to January 1994. Implant and follow up data were available for 1059 (97.3%) patients at analysis. The median (range) age was 77 years (16-99); 51.2 % were male.
RESULTS
Dual chamber units were implanted in 54.1% of patients, single chamber atrial in 5.2%, and ventricular in 40.7%. A temporary pacing lead was present at implant in 22.9% of patients. Most (93.6%) implants were performed via the subclavian vein. Immediate complications were rare: eight (0.8%) patients developed pneumothorax requiring medical treatment and 11 (1.0%) an insignificant pneumothorax. There was no significant difference in the pneumothorax rate for dual chamber (DDD) compared with single chamber systems. Arterial puncture without sequelae was documented in 2.7% of attempts at subclavian vein cannulation. A total of 35 patients (3.3%) required reoperation; the reoperation rate for dual chamber (3.5%) was similar to that for single chamber (3.1%) systems. Electrode displacement (n = 15, 1.4%) was the most common reason for reoperation. Atrial lead displacement (n = 10, 1.6% of atrial leads) was significantly more common than ventricular lead displacement (n = 5, 0.5% of ventricular leads, P = 0.047). There was no difference in electrode displacement rates for dual (1.6%) compared with single (1.2%) chamber systems. Pacemaker pocket infection led to reoperation in 10 patients (six dual, four single chamber, P = not significant) and was significantly more common in patients who had a temporary pacing lead in place at implant (2.9%) than in those who did not (0.4%, P = 0.0014). Five patients (0.5%) required reoperation for generator erosion (two dual, three single chamber, P = not significant). and a further five for drainage of haematoma or a serous fluid collection (three dual, two single chamber, P = not significant). Complications that did not require reoperation were also rare. Undersensing occurred in 10 patients (0.9%). Atrial undersensing (n = 8) was significantly more common than ventricular undersensing (n = 2, P = 0.017). All patients were successfully treated by reprogramming of sensitivity. Superficial wound infection was treated successfully with antibiotics in nine patients (six dual, three single chamber, P = not significant). Three patients with DDD generators developed sustained atrial fibrillation: two required reprogramming to VVI mode and one required cardioversion.
CONCLUSIONS
Permanent pacing in a large tertiary referral centre with experienced operators carries a low risk. Infection rates are low, < 1% overall but significantly higher in patients who undergo temporary pacing before implantation. Lead displacement and undersensing are more likely to occur with atrial than ventricular leads. The overall complication rate for dual chamber pacing, however, is no higher than for single chamber pacing.
Topics: Adolescent; Adult; Aged; Aged, 80 and over; Equipment Failure; Female; Follow-Up Studies; Humans; Incidence; Intraoperative Complications; Male; Middle Aged; Pacemaker, Artificial; Pneumothorax; Postoperative Complications; Prospective Studies; Prosthesis Design; Reoperation; Surgical Wound Infection
PubMed: 7626359
DOI: 10.1136/hrt.73.6.571 -
British Heart Journal Nov 1981A prospective trial was conducted to assess the value of prophylactic antibiotic treatment in preventing postoperative infection of permanent transvenous pacemaker... (Clinical Trial)
Clinical Trial
A prospective trial was conducted to assess the value of prophylactic antibiotic treatment in preventing postoperative infection of permanent transvenous pacemaker systems. Four hundred and thirty-one patients were randomly allocated to treatment (234) or no-treatment (197) groups. Treated patients received systemic benzylpenicillin and flucloxacillin just before operation and one and six hours afterwards. Nine primary generator pocket infections occurred without evidence of wound dehiscence or skin erosion. Seven infections were in untreated patients and two in treated patients. Antibiotic prophylaxis diminishes the risk of infection after pacemaker implantations.
Topics: Adult; Aged; Anti-Bacterial Agents; Bacterial Infections; Drug Combinations; Floxacillin; Humans; Middle Aged; Pacemaker, Artificial; Penicillin G; Premedication; Prospective Studies; Time Factors
PubMed: 7317219
DOI: 10.1136/hrt.46.5.539 -
Ear, Nose, & Throat Journal Sep 2015
Topics: Adult; Chorda Tympani Nerve; Female; Hearing Loss, Conductive; Humans; Incus; Otitis Media with Effusion; Otoscopy; Tympanoplasty
PubMed: 26401664
DOI: 10.1177/014556131509400901 -
Health Care Financing Review Dec 1981Between 1950 and 1980, the physician fee component of the Consumer Price Index (CPI) rose 488 percent. In contrast, an index of physician fees adjusted for 1) overall... (Comparative Study)
Comparative Study
Between 1950 and 1980, the physician fee component of the Consumer Price Index (CPI) rose 488 percent. In contrast, an index of physician fees adjusted for 1) overall inflation, and 2) the declining proportion which is paid out-of-pocket by the patient, declined over the same 30-year period. This last observation, pointing to the erosion of the market, is important for structuring price competition for physician services. For insured patients, out-of-pocket payments arise from deductibles, coinsurance and limits, each of which is briefly discussed in this article. Following a review of Medicare Part B physician reimbursement, the paper shows that limits can be used to strengthen the incentive which insured patients have to search for less expensive medical care.
Topics: Community Participation; Deductibles and Coinsurance; Fees, Medical; Insurance, Physician Services; Medicare; United States
PubMed: 10309559
DOI: No ID Found