Current Pediatric Reviews 2017To identify the anthropometric variables in equations/reference values of impulse oscillometry system (IOS) parameters in preschoolers, children and adolescents. (Review)
Review
BACKGROUND
To identify the anthropometric variables in equations/reference values of impulse oscillometry system (IOS) parameters in preschoolers, children and adolescents.
METHOD
Systematic search on the databases MEDLINE/Ovid, SCOPUS and SciELO using the key words "preschool, child and adolescent", "impulse oscillometry", "reference values" and its variations.
RESULTS
This review considered a total of 13 articles. The studies presented height, weight, sex and age as the variables correlated to oscillometric parameters. Most studies do not present the correlation values of analyzed variables, and only a few presented the results considering gender differences. The coefficients of determination of the equations were low, specially for the samples including preschoolers. Height was identified as the most influent predictive variable to IOS parameters in the studied age group.
CONCLUSION
Anthropometric variables, especially height, plays an important role determining reference values/equations for oscillometric parameters, however, the data acquisition method should be standardized.
Topics: Adolescent; Anthropometry; Child; Child, Preschool; Female; Humans; Male; Oscillometry; Reference Values
PubMed: 28637400
DOI: 10.2174/1573396313666170622075940 -
European Respiratory Review : An... Sep 2022Respiratory oscillometry is gaining global attention over traditional pulmonary function tests for its sensitivity in detecting small airway obstructions. However, its... (Review)
Review
Respiratory oscillometry is gaining global attention over traditional pulmonary function tests for its sensitivity in detecting small airway obstructions. However, its use in clinical settings as a diagnostic tool is limited because oscillometry lacks globally accepted reference values. In this scoping review, we systematically assessed the differences between selected oscillometric reference equations with the hypothesis that significant heterogeneity existed between them. We searched bibliographic databases, registries and references for studies that developed equations for healthy adult populations according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. A widely used Caucasian model was used as the standard reference and compared against other models using Bland-Altman and Lin's concordance correlational analyses. We screened 1202 titles and abstracts, and after a full-text review of 67 studies, we included 10 in our analyses. Of these, three models had a low-to-moderate agreement with the reference model, particularly those developed from non-Caucasian populations. Although the other six models had a moderate-to-high agreement with the standard model, there were still significant sex-specific variations. This is the first systematic analysis of the heterogeneity between oscillometric reference models and warrants the validation of appropriate equations in clinical applications of oscillometry to avoid diagnostic errors.
Topics: Female; Humans; Male; Oscillometry; Reference Values; Respiratory Function Tests
PubMed: 35831009
DOI: 10.1183/16000617.0021-2022 -
Physiological Measurement Sep 2022: Accurate and reliable blood pressure (BP) measurement is important for the prevention and treatment of hypertension. The oscillometric-based automatic office blood... (Review)
Review
: Accurate and reliable blood pressure (BP) measurement is important for the prevention and treatment of hypertension. The oscillometric-based automatic office blood pressure measurement (AOBPM) is widely used in hospitals and clinics, but measurement errors are common in BP measurements. There is a lack of systematic review of the sources of measurement errors.: A systematic review of all existing research on sources of AOBPM errors. A search strategy was designed in six online databases, and all the literature published before October 2021 was selected. Those studies that used the AOBPM device to measure BP from the upper arm of subjects were included.: A total of 1365 studies were screened, and 224 studies were included in this final review. They investigated 22 common error sources with clinical AOBPM. Regarding the causes of BP errors, this review divided them into the following categories: the activities before measurement, patient's factors, measurement environment, measurement procedure, and device settings. 13 sources caused increased systolic and diastolic BP (SBP and DBP), 2 sources caused the decrease in SBP and DBP, only 1 source had no significant effect on BPs, and the other errors had a non-uniform effect (either increase or decrease in BPs). The error ranges for SBP and DBP were -14 to 33 mmHg and -6 to 19 mmHg, respectively.: The measurement accuracy of AOBPM is susceptible to the influence of measurement factors. Interpreting BP readings need to be treated with caution in clinical measurements. This review made comprehensive evidence for the need for standardized BP measurements and provided guidance for clinical practitioners when measuring BP with AOBPM devices.
Topics: Blood Pressure; Blood Pressure Determination; Humans; Hypertension; Oscillometry; Sphygmomanometers
PubMed: 35952651
DOI: 10.1088/1361-6579/ac890e -
Journal of Hypertension Feb 2017The phase-out of mercury from clinical settings calls for valid alternatives to assess blood pressure (BP) in children. Aneroid devices provide a mercury-free... (Meta-Analysis)
Meta-Analysis Review
BACKGROUND
The phase-out of mercury from clinical settings calls for valid alternatives to assess blood pressure (BP) in children. Aneroid devices provide a mercury-free alternative to BP measurements by auscultation, whereas oscillometric (automated) devices are increasingly becoming the norm in clinical practice due to their ease of use. The aim of this systematic review and meta-analysis was to investigate the accuracy of oscillometric and aneroid BP devices compared with the mercury sphygmomanometer for the measurement of BP in children.
METHODS
We systematically searched four electronic databases (MEDLINE, Embase, CINAHL, and Web of Science) and relevant journals for eligible articles published before 30 July 2015. We screened 1415 articles, and two authors independently reviewed 92 full-text articles.
RESULTS
We included 29 articles (38 studies) with 26 879 children. Random-effects model meta-analyses revealed that oscillometric devices yield higher measurements of SBP than auscultation with a mercury sphygmomanometer (pooled effect estimate 2.53 mmHg; 95% CI 0.57-4.50; P < 0.05); the pooled effect estimate for SBP was smaller in studies that 'passed' validation protocols (1.76 mmHg; 95% CI 0.61-2.81; n = 12). There was no significant difference for DBP (pooled effect estimate 1.55 mmHg; 95% CI -0.20 to 3.31). There was heterogeneity between studies, explained in part by differences in manufacturer, study setting and observer training. Only three studies compared BP using aneroid and mercury devices and found comparable results.
CONCLUSION
Oscillometric devices may serve as a suitable alternative to auscultation for initial BP screening in the pediatric population.
Topics: Auscultation; Blood Pressure; Blood Pressure Determination; Child; Humans; Oscillometry; Reproducibility of Results; Sphygmomanometers
PubMed: 27870656
DOI: 10.1097/HJH.0000000000001178 -
Pediatric Pulmonology Nov 2016The bronchodilator response (BDR) is frequently used to support diagnostic and therapeutic decision-making for children who wheeze. However, there is little... (Review)
Review
BACKGROUND
The bronchodilator response (BDR) is frequently used to support diagnostic and therapeutic decision-making for children who wheeze. However, there is little evidence-based guidance describing the role of BDR testing in preschool children and it is unclear whether published cut-off values, which are derived from adult data, can be applied to this population.
METHODS
We searched MEDLINE, EMBASE, Web of Science, and Cochrane databases (inception-September 2015) for studies reporting response to a bronchodilator in healthy preschool children, response following placebo inhalation, and the diagnostic efficacy of BDR compared with a clinical diagnosis of asthma/recurrent wheezing.
FINDINGS
We included 14 studies. Thirteen studies provided BDR data from healthy preschool children. Two studies reported response to placebo in preschool children with asthma/recurrent wheezing. Twelve studies compared BDR measurements from preschool children with asthma/recurrent wheeze to those from healthy children and seven of these studies reported diagnostic efficacy. Significant differences between the BDR measured in healthy preschool children compared with that in children with asthma/recurrent wheeze were demonstrated in some, but not all studies. Techniques such as interrupter resistance, oscillometry, and plethysmography were more consistently successfully completed than spirometry. Between study heterogeneity precluded determination of an optimum technique.
INTERPRETATION
There is little evidence to suggest spirometry-based BDR can be used in the clinical assessment of preschool children who wheeze. Further evaluation of simple alternative techniques is required. Future studies should recruit children in whom airways disease is suspected and should evaluate the ability of BDR testing to predict treatment response. Pediatr Pulmonol. 2016;51:1242-1250. © 2016 Wiley Periodicals, Inc.
Topics: Administration, Inhalation; Asthma; Bronchodilator Agents; Child, Preschool; Humans; Oscillometry; Respiratory Sounds; Spirometry
PubMed: 27273556
DOI: 10.1002/ppul.23459 -
Paediatric Respiratory Reviews Jun 2017Diagnosis and management of asthma often relies mostly on symptoms because spirometry is not always reliable in some age groups, such as preschoolers. It is unclear... (Review)
Review
Diagnosis and management of asthma often relies mostly on symptoms because spirometry is not always reliable in some age groups, such as preschoolers. It is unclear whether impulse oscillometry (IOS) can supplement or replace spirometry. Available reports suggest that IOS has been applied with success in asthmatic children and adolescents to assess exacerbations, level of control, severity and response to treatment in the short and long term. Very few studies using adequate sample sizes and methods have been performed comparing the accuracy of IOS to spirometry for the diagnosis of asthma. Our systematic review found only four studies that met the eligibility criteria. However, no meta-analysis was possible with the available data. Consequently, this review helps to identify research gaps involving IOS, highlighting opportunities for future studies.
Topics: Adolescent; Asthma; Child; Dimensional Measurement Accuracy; Forced Expiratory Volume; Humans; Oscillometry; Respiratory Function Tests
PubMed: 27825614
DOI: 10.1016/j.prrv.2016.09.002 -
Anaesthesiology Intensive Therapy 2022Mean arterial pressure (MAP) is a key haemodynamic variable monitored in critically ill patients. The advantages of oscillometric noninvasive blood pressure (NIBP)... (Meta-Analysis)
Meta-Analysis Review
Mean arterial pressure (MAP) is a key haemodynamic variable monitored in critically ill patients. The advantages of oscillometric noninvasive blood pressure (NIBP) measurement are its easy and fast methodology; however, the accuracy and the precision of this measurement in critically ill patients is constantly debated. We performed a systematic review and meta-analysis of observational studies comparing oscillometric NIBP methods with invasive arterial pressure (IAP) measurements. We included studies of adult critically ill patients, which evaluated MAP in the same patient by both NIBP and IAP at any site. We included only studies comparing simultaneous measurements of arterial pressure by NIBP and IAP, reporting their results using mean difference and SD of agreement. The main outcome was to define the bias of the MAP measured by NIBP over the IAP measurement. The quality of the studies was analysed by the QUADAS 2 tool. Seven studies and 1593 patients were included in the main analysis. The oscillometric NIBP method had a mean value of -1.50 mmHg when compared with IAP (95% CI: -3.34 to 0.35; I2 = 96% for random effects model, P < 0.01). The limits of agreement for MAP varied between -14.6 mmHg and +40.3 mmHg. NIBP had an adequate accuracy regarding MAP measurements by oscillometry. Limits of agreement may thus narrow the clinical applicability in scenarios in which there is a need for a more precise management of blood pressure.
Topics: Adult; Humans; Blood Pressure; Blood Pressure Determination; Oscillometry; Critical Illness; Arterial Pressure
PubMed: 36734453
DOI: 10.5114/ait.2022.123120 -
International Journal of Clinical... Sep 2017Peripheral arterial disease (PAD) remains underdiagnosed and undertreated, partly because of limitations in the Doppler ankle-brachial index (ABI), the non-invasive gold... (Meta-Analysis)
Meta-Analysis Review
INTRODUCTION
Peripheral arterial disease (PAD) remains underdiagnosed and undertreated, partly because of limitations in the Doppler ankle-brachial index (ABI), the non-invasive gold standard.
OBJECTIVE
This systematic review and meta-analysis aims to compare the diagnostic accuracy of the oscillometric ABI and the Doppler ABI, and to examine the influence of two approaches to analysis: legs vs subjects and inclusion of oscillometric errors as PAD equivalents vs exclusion.
METHODS
Systematic searches in EMBASE, MEDLINE, Web of Science and the Cochrane Library databases were performed, from inception to February 2017. Random-effects models were computed with the Moses-Littenberg constant. Hierarchical summary receiver operating characteristic curves (HSROC) were used to summarise the overall test performance.
RESULTS
Twenty studies (1263 subjects and 3695 legs) were included in the meta-analysis. The pooled diagnostic odds ratio (dOR) for the oscillometric ABI was 32.49 (95% CI: 19.6-53.8), with 65% sensitivity (95% CI: 57-74) and 96% specificity (95%CI: 93-99). In the subgroup analysis, the "per subjects" group showed a better performance than the "per legs" group (dOR 36.44 vs 29.03). Similarly, an analysis considering oscillometric errors as PAD equivalents improved diagnostic performance (dOR 31.48 vs 28.29). The time needed for the oscillometric ABI was significantly shorter than that required for the Doppler ABI (5.90 vs 10.06 minutes, respectively).
CONCLUSIONS AND RELEVANCE
The oscillometric ABI showed an acceptable diagnostic accuracy and feasibility, potentially making it a useful tool for PAD diagnosis. We recommend considering oscillometric errors as PAD equivalents, and a "per subject" instead of a "per leg" approach, in order to improve sensitivity. Borderline oscillometric ABI values in diabetic population should raise concern of PAD.
Topics: Ankle Brachial Index; Humans; Lower Extremity; Odds Ratio; Oscillometry; Peripheral Arterial Disease; ROC Curve; Sensitivity and Specificity
PubMed: 28851093
DOI: 10.1111/ijcp.12994 -
Children (Basel, Switzerland) Sep 2021Spirometry is considered the gold standard method for monitoring lung function of patients with cystic fibrosis (CF) but it requires patients' cooperation and therefore... (Review)
Review
Spirometry is considered the gold standard method for monitoring lung function of patients with cystic fibrosis (CF) but it requires patients' cooperation and therefore it is not useful for the majority of preschool-aged children. Oscillometry is an alternative modality for lung function monitoring that requires minimal cooperation and can be applied in children as young as 3 years of age. Furthermore, it generates lesser aerosol compared to spirometry, an issue that is of considerable importance in the COVID-19 era. The aim of this review was to present the existing clinical data regarding the application of oscillometry in children and adolescents with CF. The method seems to have acceptable feasibility and repeatability. However, there is conflicting data regarding the correlation of oscillometry values with the clinical symptoms of CF patients either in clinically stable or in exacerbation periods. Furthermore, it is not clear to what extent oscillometry measurements correlate with the spirometry indices. Based on current evidence, spirometry cannot be substituted by oscillometry in the monitoring of the respiratory status of children and adolescents with CF.
PubMed: 34682122
DOI: 10.3390/children8100857 -
BMJ Open Respiratory Research Dec 2020Asthma is a common, heterogeneous disease that is characterised by chronic airway inflammation and variable expiratory airflow limitation. Current guidelines use...
BACKGROUND
Asthma is a common, heterogeneous disease that is characterised by chronic airway inflammation and variable expiratory airflow limitation. Current guidelines use spirometric measures for asthma assessment. This systematic review aimed to assess whether the most commonly reported tests of small airways function could contribute to the diagnosis of asthma.
METHODS
Standard systematic review methodology was used, and a range of electronic databases was searched (Embase, MEDLINE, CINAHL, CENTRAL, Web of Science, DARE). Studies that included physiological tests of small airways function to diagnose asthma in adults were included, with no restrictions on language or date. The risk of bias and quality assessment tools used were Agency for Healthcare Research and Quality tool for cross-sectional studies and Quality Assessment of Diagnostic Accuracy Studies 2 for diagnostic test accuracy (DTA) studies.
RESULTS
7072 studies were identified and 10 studies met review criteria. 7 included oscillation techniques and 5 included maximal mid-expiratory flow (MMEF). Studies were small and of variable quality. In oscillometry, total resistance (R5) and reactance at 5 Hz (X5) was altered in asthma compared with healthy controls. The percentage predicted of MMEF was lower in patients with asthma compared with controls in all studies and lower than the % predicted forced expiratory volume in 1 s. In DTA of oscillometry, R5 showed a sensitivity between 69% and 72% and specificity between 61% and 86%.
CONCLUSION
There were differences in the results of physiological tests of small airway function in patients with asthma compared with controls. However, studies are small and heterogeneous. Further studies are needed to assess the effectiveness of these tests on a larger scale, including studies to determine which test methodology is the most useful in asthma.
Topics: Adult; Asthma; Cross-Sectional Studies; Diagnostic Tests, Routine; Forced Expiratory Volume; Humans; Spirometry; United States
PubMed: 33371011
DOI: 10.1136/bmjresp-2020-000770