-
Autoimmunity Reviews Feb 2018Early diagnosis of Takayasu's Arteritis (TAK) and detection of disease activity may reduce the risk of vascular complications. The objective of this study was to... (Meta-Analysis)
Meta-Analysis Review
BACKGROUND
Early diagnosis of Takayasu's Arteritis (TAK) and detection of disease activity may reduce the risk of vascular complications. The objective of this study was to determine the effectiveness of imaging modalities for the management of TAK.
METHODS
MEDLINE and EMBASE were searched for studies of patients undergoing various imaging modalities for TAK diagnosis or to assess disease activity. We excluded case reports, reviews and case series with <10 patients. The methodologic quality was assessed using the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2). Random effects meta-analyses with inverse-variance weighting were performed.
RESULTS
From the 1126 citations screened, 57 studies met our inclusion criteria. Many of the studies were of small sample size (average N=27), cross-sectional design and low methodological quality. Ultrasound (US) had a lower pooled sensitivity (SN) of 81% (95% CI: 69-89%) than Magnetic Resonance Angiography (MRA) with SN=92% (95% CI: 88-95%) for TAK diagnosis (by clinical criteria and/or X-Ray angiography). Both had high specificities (SP) of >90% for TAK diagnosis. Fewer studies investigated computed tomography angiography (CTA), but SN and SP for TAK diagnosis was high (>90%). The utility of vessel wall thickening and enhancement by MRA and CTA to predict disease activity varied across studies. The pooled SN and SP of F-fluorodeoxyglucose-Positron Emission Tomography (FDG-PET) for disease activity was 81% (95% CI: 69-89%) and 74% (95% CI: 55-86%), respectively.
CONCLUSION
US, CTA and/or MRA are effective for the diagnosis of TAK. The utility of these imaging modalities for assessing disease activity remains unclear.
Topics: Adult; Cross-Sectional Studies; Humans; Middle Aged; Positron-Emission Tomography; Takayasu Arteritis; Tomography, X-Ray Computed
PubMed: 29313811
DOI: 10.1016/j.autrev.2017.11.021 -
European Radiology Apr 2020Skeletal muscle metastases (SMM) are a rare entity, mainly detected at autopsy. Nevertheless, radiological and nuclear medicine imaging can contribute to the diagnosis...
AIM OF THE STUDY
Skeletal muscle metastases (SMM) are a rare entity, mainly detected at autopsy. Nevertheless, radiological and nuclear medicine imaging can contribute to the diagnosis with a significant impact on the treatment and prognosis of neoplastic patients. This study aimed to systematically review the features of SMM at imaging considering the primary tumors and the sites of occurrence.
MATERIALS AND METHODS
We conducted a systematic search of three electronic database (i.e., PubMed, Science Direct, and Web of Science) up to May 2019, without any language or time interval restriction. Two reviewers performed the search and selection process, data extraction, and synthesis. We resolved disagreements by consensus and/or involving a third reviewer. The included studies have been classified according to the Oxford Centre for Evidence Based Medicine (CEBM) grading system.
RESULTS
Out of 8598 and 1077 articles respectively for radiological and hybrid imaging, 29 papers were included. According to CEBM, twelve were level 4. Computed tomography (CT) is mainly applied and, despite the existence of CT and magnetic resonance-based classifications, these are rarely used. Positron emission tomography/CT allowed the detection of small and subtle lesion also in the extremities. Muscles of the trunk were mostly affected and mainly respiratory tumors are associated with this type of metastatic spread.
CONCLUSION
Radiological and hybrid imaging allow a precise characterization of SMM. However, a more systematic approach, including also the application of available classification systems, may increase the diagnostic accuracy for this rare type of metastases.
KEY POINTS
• Skeletal muscle metastases have heterogeneous characteristics at imaging but mostly abscess-like features and high metabolic activity are described. • Skeletal muscle metastases mainly affect the muscles of the trunk. • Pulmonary, urological, and gastrointestinal cancers are the most frequent cause of skeletal muscle metastases.
Topics: Gastrointestinal Neoplasms; Humans; Lung Neoplasms; Magnetic Resonance Imaging; Multimodal Imaging; Muscle Neoplasms; Muscle, Skeletal; Neoplasms, Unknown Primary; Positron Emission Tomography Computed Tomography; Positron-Emission Tomography; Prognosis; Tomography, X-Ray Computed; Torso; Urologic Neoplasms
PubMed: 31834507
DOI: 10.1007/s00330-019-06555-4 -
Academic Radiology Nov 2021Hyposmia/anosmia is common among patients with coronavirus disease-2019 (COVID-19). Various imaging modalities have been used to assess olfactory dysfunction in...
RATIONALE AND OBJECTIVES
Hyposmia/anosmia is common among patients with coronavirus disease-2019 (COVID-19). Various imaging modalities have been used to assess olfactory dysfunction in COVID-19. In this systematic review, we sought to categorize and summarize the imaging data in COVID-19-induced anosmia.
MATERIAL AND METHODS
Eligible articles were included after a comprehensive review using online databases including Google scholar, Scopus, PubMed, Web of science and Elsevier. Duplicate results, conference abstracts, reviews, and studies in languages other than English were excluded.
RESULTS
In total, 305 patients undergoing MRI/functional MRI (177), CT of paranasal sinuses (129), and PET/CT or PET/MRI scans (14) were included. Out of a total of 218 findings reported on MRI, 80 were reported on early (≤ 1 month) and 85 on late (>1 month) imaging in relation to the onset of anosmia. Overall, OB morphology and T2-weighted or FLAIR signal intensity were normal in 68/218 (31.2%), while partial or complete opacification of OC was observed in 60/218 (27.5%). T2 hyperintensity in OB was detected in 11/80 (13.75%) and 18/85 (21.17%) on early and late imaging, respectively. Moreover, OB atrophy was reported in 1/80 (1.25%) on early and in 9/85 (10.58%) on late imaging. Last, among a total of 129 CT scans included, paranasal sinuses were evalualted in 88 (68.21%), which were reported as normal in most cases (77/88, [87.5%]).
CONCLUSION
In this systematic review, normal morphology and T2/FLAIR signal intensity in OB and OC obstruction were the most common findings in COVID-19-induced anosmia, while paranasal sinuses were normal in most cases. OC obstruction is the likely mechanism for olfactory dysfunction in COVID-19. Abnormalities in OB signal intensity and OB atrophy suggest that central mechanisms may also play a role in late stage in COVID-19-induced anosmia.
Topics: COVID-19; Humans; Magnetic Resonance Imaging; Olfaction Disorders; Positron Emission Tomography Computed Tomography; SARS-CoV-2
PubMed: 34548231
DOI: 10.1016/j.acra.2021.08.010 -
Clinical Endocrinology Sep 2023Minimally invasive parathyroidectomy (MIP) is the standard of care for primary hyperparathyroidism (PHPT). Four dimensional computed tomography(4DCT) and F-18... (Meta-Analysis)
Meta-Analysis
Comparison of 4D computed tomography and F-18 fluorocholine PET for localisation of parathyroid lesions in primary hyperparathyroidism: A systematic review and meta-analysis.
Minimally invasive parathyroidectomy (MIP) is the standard of care for primary hyperparathyroidism (PHPT). Four dimensional computed tomography(4DCT) and F-18 Fluorocholine positron emission tomography/computed tomography (FCH PET/CT) localize adenomas accurately to perform MIP. We aimed to conduct a systematic review and metanalysis to evaluate the diagnostic performance of 4DCT and FCH PET/CT scan for quadrant wise localisation in PHPT patients and to do head-to-head comparison between these two modalities. DESIGN, PATIENTS AND MEASUREMENT : After searching through PubMed and EMBASE databases, 46 studies (using histology as a gold standard) of 4DCT and FCH PET/CT were included. RESULTS: Total number of patients included were 1651 and 952 for 4DCT scan (studies n = 26) and FCH PET/CT scan (studies n = 24) respectively. In per patient analysis, FCH PET/CT and 4DCT had pooled sensitivities of 92% (88-94) and 85% (73-92) respectively and in per lesion analysis, 90% (86-93) and 79% (71-84), respectively. In the subgroup with negative conventional imaging/persistent PHPT, FCH PET/CT had comparable sensitivity to 4DCT (84% [74-90] vs. 72% [46-88]). As per patient wise analysis, FCH PET/CT had better detection rates than 4DCT ([92.4 vs. 76.85], odds ratio -3.89 [1.6-9.36] p = .0024) in the subpopulation where both FCH PET/CT and 4DCT were reported. CONCLUSION: Both 4DCT and FCH PET/CT scan performed well in newly diagnosed patients, patients with persistent disease and in those with inconclusive conventional imaging results. FCH PET/CT scan had a higher pooled sensitivity than 4DCT in detecting patients with PHPT in head to head comparison.
Topics: Humans; Positron Emission Tomography Computed Tomography; Four-Dimensional Computed Tomography; Hyperparathyroidism, Primary; Parathyroid Glands; Choline
PubMed: 36593125
DOI: 10.1111/cen.14875 -
The Lancet. Infectious Diseases Jan 2017Sensitivity and specificity of the modified Duke criteria for native valve endocarditis are both suboptimal, at approximately 80%. Diagnostic accuracy for intracardiac... (Review)
Review
Sensitivity and specificity of the modified Duke criteria for native valve endocarditis are both suboptimal, at approximately 80%. Diagnostic accuracy for intracardiac prosthetic material-related infection is even lower. Non-invasive imaging modalities could potentially improve diagnosis of infective endocarditis; however, their diagnostic value is unclear. We did a systematic literature review to critically appraise the evidence for the diagnostic performance of these imaging modalities, according to PRISMA and GRADE criteria. We searched PubMed, Embase, and Cochrane databases. 31 studies were included that presented original data on the performance of electrocardiogram (ECG)-gated multidetector CT angiography (MDCTA), ECG-gated MRI, F-fluorodeoxyglucose (F-FDG) PET/CT, and leucocyte scintigraphy in diagnosis of native valve endocarditis, intracardiac prosthetic material-related infection, and extracardiac foci in adults. We consistently found positive albeit weak evidence for the diagnostic benefit of F-FDG PET/CT and MDCTA. We conclude that additional imaging techniques should be considered if infective endocarditis is suspected. We propose an evidence-based diagnostic work-up for infective endocarditis including these non-invasive techniques.
Topics: Cardiac-Gated Single-Photon Emission Computer-Assisted Tomography; Computed Tomography Angiography; Electrocardiography; Endocarditis; Fluorodeoxyglucose F18; Humans; Sensitivity and Specificity
PubMed: 27746163
DOI: 10.1016/S1473-3099(16)30141-4 -
International Journal of Molecular... Jun 2023Various papers have introduced the use of positron emission tomography (PET) with [Ga]Ga-radiolabeled fibroblast-activation protein inhibitor (FAPi) radiopharmaceuticals... (Meta-Analysis)
Meta-Analysis Review
Various papers have introduced the use of positron emission tomography (PET) with [Ga]Ga-radiolabeled fibroblast-activation protein inhibitor (FAPi) radiopharmaceuticals in different subtypes of gastric cancer (GC). Our aim was to assess the diagnostic performance of this novel molecular imaging technique in GC with a systematic review and meta-analysis. A straightforward literature search of papers concerning the diagnostic performance of FAP-targeted PET imaging was performed. Original articles evaluating this novel molecular imaging examination in both newly diagnosed GC patients and GC patients with disease relapse were included. The systematic review included nine original studies, and eight of them were also eligible for meta-analysis. The quantitative synthesis provided pooled detection rates of 95% and 97% for the assessment of primary tumor and distant metastases, respectively, and a pooled sensitivity and specificity of 74% and 89%, respectively, for regional lymph node metastases. Significant statistical heterogeneity among the included studies was found only in the analysis of the primary tumor detection rate (I = 64%). Conclusions: Beyond the limitations of this systematic review and meta-analysis (i.e., all the included studies were conducted in Asia, and using [F]FDG PET/CT as a comparator of the index test), the quantitative data provided demonstrate the promising diagnostic performance of FAP-targeted PET imaging in GC. Nevertheless, more prospective multicentric studies are needed to confirm the excellent performances of FAP-targeted PET in this cluster of patients.
Topics: Humans; Positron Emission Tomography Computed Tomography; Stomach Neoplasms; Prospective Studies; Neoplasm Recurrence, Local; Positron-Emission Tomography; Radiopharmaceuticals; Fluorodeoxyglucose F18; Gallium Radioisotopes
PubMed: 37373285
DOI: 10.3390/ijms241210136 -
Health Technology Assessment... Sep 2014Cardiac magnetic resonance imaging (CMR) is increasingly used to assess patients for myocardial viability prior to revascularisation. This is important to ensure that... (Review)
Review
Systematic review and modelling of the cost-effectiveness of cardiac magnetic resonance imaging compared with current existing testing pathways in ischaemic cardiomyopathy.
BACKGROUND
Cardiac magnetic resonance imaging (CMR) is increasingly used to assess patients for myocardial viability prior to revascularisation. This is important to ensure that only those likely to benefit are subjected to the risk of revascularisation.
OBJECTIVES
To assess current evidence on the accuracy and cost-effectiveness of CMR to test patients prior to revascularisation in ischaemic cardiomyopathy; to develop an economic model to assess cost-effectiveness for different imaging strategies; and to identify areas for further primary research.
DATA SOURCES
Databases searched were: MEDLINE including MEDLINE In-Process & Other Non-Indexed Citations Initial searches were conducted in March 2011 in the following databases with dates: MEDLINE including MEDLINE In-Process & Other Non-Indexed Citations via Ovid (1946 to March 2011); Bioscience Information Service (BIOSIS) Previews via Web of Science (1969 to March 2011); EMBASE via Ovid (1974 to March 2011); Cochrane Database of Systematic Reviews via The Cochrane Library (1996 to March 2011); Cochrane Central Register of Controlled Trials via The Cochrane Library 1998 to March 2011; Database of Abstracts of Reviews of Effects via The Cochrane Library (1994 to March 2011); NHS Economic Evaluation Database via The Cochrane Library (1968 to March 2011); Health Technology Assessment Database via The Cochrane Library (1989 to March 2011); and the Science Citation Index via Web of Science (1900 to March 2011). Additional searches were conducted from October to November 2011 in the following databases with dates: MEDLINE including MEDLINE In-Process & Other Non-Indexed Citations via Ovid (1946 to November 2011); BIOSIS Previews via Web of Science (1969 to October 2011); EMBASE via Ovid (1974 to November 2011); Cochrane Database of Systematic Reviews via The Cochrane Library (1996 to November 2011); Cochrane Central Register of Controlled Trials via The Cochrane Library (1998 to November 2011); Database of Abstracts of Reviews of Effects via The Cochrane Library (1994 to November 2011); NHS Economic Evaluation Database via The Cochrane Library (1968 to November 2011); Health Technology Assessment Database via The Cochrane Library (1989 to November 2011); and the Science Citation Index via Web of Science (1900 to October 2011). Electronic databases were searched March-November 2011.
REVIEW METHODS
The systematic review selected studies that assessed the clinical effectiveness and cost-effectiveness of CMR to establish the role of CMR in viability assessment compared with other imaging techniques: stress echocardiography, single-photon emission computed tomography (SPECT) and positron emission tomography (PET). Studies had to have an appropriate reference standard and contain accuracy data or sufficient details so that accuracy data could be calculated. Data were extracted by two reviewers and discrepancies resolved by discussion. Quality of studies was assessed using the QUADAS II tool (University of Bristol, Bristol, UK). A rigorous diagnostic accuracy systematic review assessed clinical and cost-effectiveness of CMR in viability assessment. A health economic model estimated costs and quality-adjusted life-years (QALYs) accrued by diagnostic pathways for identifying patients with viable myocardium in ischaemic cardiomyopathy with a view to revascularisation. The pathways involved CMR, stress echocardiography, SPECT, PET alone or in combination. Strategies of no testing and revascularisation were included to determine the most cost-effective strategy.
RESULTS
Twenty-four studies met the inclusion criteria. All were prospective. Participant numbers ranged from 8 to 52. The mean left ventricular ejection fraction in studies reporting this outcome was 24-62%. CMR approaches included stress CMR and late gadolinium-enhanced cardiovascular magnetic resonance imaging (CE CMR). Recovery following revascularisation was the reference standard. Twelve studies assessed diagnostic accuracy of stress CMR and 14 studies assessed CE CMR. A bivariate regression model was used to calculate the sensitivity and specificity of CMR. Summary sensitivity and specificity for stress CMR was 82.2% [95% confidence interval (CI) 73.2% to 88.7%] and 87.1% (95% CI 80.4% to 91.7%) and for CE CMR was 95.5% (95% CI 94.1% to 96.7%) and 53% (95% CI 40.4% to 65.2%) respectively. The sensitivity and specificity of PET, SPECT and stress echocardiography were calculated using data from 10 studies and systematic reviews. The sensitivity of PET was 94.7% (95% CI 90.3% to 97.2%), of SPECT was 85.1% (95% CI 78.1% to 90.2%) and of stress echocardiography was 77.6% (95% CI 70.7% to 83.3%). The specificity of PET was 68.8% (95% CI 50% to 82.9%), of SPECT was 62.1% (95% CI 52.7% to 70.7%) and of stress echocardiography was 69.6% (95% CI 62.4% to 75.9%). All currently used diagnostic strategies were cost-effective compared with no testing at current National Institute for Health and Care Excellence thresholds. If the annual mortality rates for non-viable patients were assumed to be higher for revascularised patients, then testing with CE CMR was most cost-effective at a threshold of £20,000/QALY. The proportion of model runs in which each strategy was most cost-effective, at a threshold of £20,000/QALY, was 40% for CE CMR, 42% for PET and 16.5% for revascularising everyone. The expected value of perfect information at £20,000/QALY was £620 per patient. If all patients (viable or not) gained benefit from revascularisation, then it was most cost-effective to revascularise all patients.
LIMITATIONS
Definitions and techniques assessing viability were highly variable, making data extraction and comparisons difficult. Lack of evidence meant assumptions were made in the model leading to uncertainty; differing scenarios were generated around key assumptions.
CONCLUSIONS
All the diagnostic pathways are a cost-effective use of NHS resources. Given the uncertainty in the mortality rates, the cost-effectiveness analysis was performed using a set of scenarios. The cost-effectiveness analyses suggest that CE CMR and revascularising everyone were the optimal strategies. Future research should look at implementation costs for this type of imaging service, provide guidance on consistent reporting of diagnostic testing data for viability assessment, and focus on the impact of revascularisation or best medical therapy in this group of high-risk patients.
FUNDING
The National Institute of Health Technology Assessment programme.
Topics: Cost-Benefit Analysis; Databases, Bibliographic; Echocardiography; Female; Humans; Magnetic Resonance Imaging; Male; Markov Chains; Middle Aged; Models, Economic; Myocardial Ischemia; Positron-Emission Tomography; Quality-Adjusted Life Years; State Medicine; Tomography, Emission-Computed, Single-Photon; United Kingdom
PubMed: 25265259
DOI: 10.3310/hta18590 -
The Cochrane Database of Systematic... Jan 2017Pulmonary embolism is a leading cause of pregnancy-related death. An accurate diagnosis in pregnant patients is crucial to prevent untreated pulmonary embolism as well... (Review)
Review
BACKGROUND
Pulmonary embolism is a leading cause of pregnancy-related death. An accurate diagnosis in pregnant patients is crucial to prevent untreated pulmonary embolism as well as unnecessary anticoagulant treatment and future preventive measures. Applied imaging techniques might perform differently in these younger patients with less comorbidity and altered physiology, who largely have been excluded from diagnostic studies.
OBJECTIVES
To determine the diagnostic accuracy of computed tomography pulmonary angiography (CTPA), lung scintigraphy and magnetic resonance angiography (MRA) for the diagnosis of pulmonary embolism during pregnancy.
SEARCH METHODS
We searched MEDLINE and Embase until July 2015. We used included studies as seeds in citations searches and in 'find similar' functions and searched reference lists. We approached experts in the field to help us identify non-indexed studies.
SELECTION CRITERIA
We included consecutive series of pregnant patients suspected of pulmonary embolism who had undergone one of the index tests (computed tomography (CT) pulmonary angiography, lung scintigraphy or MRA) and clinical follow-up or pulmonary angiography as a reference test.
DATA COLLECTION AND ANALYSIS
Two review authors performed data extraction and quality assessment. We contacted investigators of potentially eligible studies to obtain missing information. In the primary analysis, we regarded inconclusive index test results as a negative reference test, and treatment for pulmonary embolism after an inconclusive index test as a positive reference test.
MAIN RESULTS
We included 11 studies (four CTPA, five lung scintigraphy, two both) with a total of 695 CTPA and 665 lung scintigraphy results. Lung scintigraphy was applied by different techniques. No MRA studies matched our inclusion criteria.Overall, risk of bias and concerns regarding applicability were high in all studies as judged in light of the review research question, as was heterogeneity in study methods. We did not undertake meta-analysis. All studies used clinical follow-up as a reference standard, none in a manner that enabled reliable identification of false positives. Sensitivity and negative predictive value were therefore the only valid test accuracy measures.The median negative predictive value for CTPA was 100% (range 96% to 100%). Median sensitivity was 83% (range 0% to 100%).The median negative predictive value for lung scintigraphy was 100% (range 99% to 100%). Median sensitivity was 100% (range 0% to 100%).The median frequency of inconclusive results was 5.9% (range 0.9% to 36%) for CTPA and 4.0% (range 0% to 23%) for lung scintigraphy. The overall median prevalence of pulmonary embolism was 3.3% (range 0.0% to 8.7%).
AUTHORS' CONCLUSIONS
Both CTPA and lung scintigraphy seem appropriate for exclusion of pulmonary embolism during pregnancy. However, the quality of the evidence mandates cautious adoption of this conclusion. Important limitations included poor reference standards, necessary assumptions in the analysis regarding inconclusive test results and the inherent inability of included studies to identify false positives. It is unclear which test has the highest accuracy. There is a need for direct comparisons between diagnostic methods, including MR, in prospective randomized diagnostic studies.
Topics: Angiography; Female; Humans; Magnetic Resonance Angiography; Positron-Emission Tomography; Pregnancy; Pregnancy Complications, Hematologic; Pulmonary Embolism; Radionuclide Imaging; Sensitivity and Specificity; Tomography, X-Ray Computed
PubMed: 28124411
DOI: 10.1002/14651858.CD011053.pub2 -
Autoimmunity Reviews Mar 2021Positron emission tomography (PET) is a nuclear imaging modality that relies on visualization of molecular targets in tissues, which is nowadays combined with a... (Review)
Review
Positron emission tomography (PET) is a nuclear imaging modality that relies on visualization of molecular targets in tissues, which is nowadays combined with a structural imaging modality such as computed tomography (CT) or Magnetic Resonance Imaging (MRI) and referred to as hybrid PET imaging. This technique allows to image specific immunological targets in rheumatoid arthritis (RA). Moreover, quantification of the PET signal enables highly sensitive monitoring of therapeutic effects on the molecular target. PET may also aid in stratification of the immuno-phenotype at baseline in order to develop personalized therapy. In this systematic review we will provide an overview of novel PET tracers, investigated in the context of RA, either pre-clinically, or clinically, that specifically visualize immune cells or stromal cells, as well as other factors and processes that contribute to pathology. The potential of these tracers in RA diagnosis, disease monitoring, and prediction of treatment outcome will be discussed. In addition, novel PET tracers established within the field of oncology that may be of use in RA will also be reviewed in order to expand the future opportunities of PET imaging in RA.
Topics: Arthritis, Rheumatoid; Humans; Magnetic Resonance Imaging; Positron-Emission Tomography; Tomography, X-Ray Computed
PubMed: 33476822
DOI: 10.1016/j.autrev.2021.102764 -
Neurosurgical Review Jul 2023While magnetic resonance imaging (MRI) is the current standard imaging method for diagnosing and localizing corticotropinomas in Cushing disease, it can fail to detect... (Review)
Review
While magnetic resonance imaging (MRI) is the current standard imaging method for diagnosing and localizing corticotropinomas in Cushing disease, it can fail to detect adenomas in up to 40% of cases. Recently, positron emission tomography (PET) has shown promise as a diagnostic tool to detect pituitary adenomas in Cushing disease. We perform a scoping review to characterize the uses of PET in diagnosing Cushing disease, with a focus on describing the types of PET investigated and defining PET-positive disease. A scoping review was conducted following the PRISMA-ScR guidelines. Thirty-one studies fulfilled our inclusion criteria, consisting of 10 prospective studies, 8 retrospective studies, 11 case reports, and 2 illustrative cases with a total of 262 patients identified. The most commonly utilized PET modalities in prospective/retrospective studies were FDG PET (n = 5), MET PET (n = 5), 68 Ga-DOTATATE PET (n = 2), 13N-ammonia PET (n = 2), and 68 Ga-DOTA-CRH PET (n = 2). MRI positivity ranged from 13 to 100%, while PET positivity ranged from 36 to 100%. In MRI-negative disease, PET positivity ranged from 0 to 100%. Five studies reported the sensitivity and specificity of PET, which ranged from 36 to 100% and 50 to 100%, respectively. PET shows promise in detecting corticotropinomas in Cushing disease, including MRI-negative disease. MET PET has been highly investigated and has demonstrated excellent sensitivity and specificity. However, preliminary studies with FET PET and 68 Ga-DOTA-CRH PET show promise for achieving high sensitivity and specificity and warrant further investigation.
Topics: Humans; Pituitary ACTH Hypersecretion; Nitrogen Radioisotopes; Prospective Studies; Retrospective Studies; Positron-Emission Tomography
PubMed: 37393399
DOI: 10.1007/s10143-023-02077-2